Sie sind auf Seite 1von 6

Client : GULF STEEL WORKS Date : 07/12/21 Sheet no

Project : GULF IND. GRATING FACTORY Dsgn By: AVB REV :

PGT Job no: Structure: SAND BLASTING SHED Chk By : HDM

INDEX

SR NO TABLE OF CONTENTS PG. NO.

1 INTRODUCTION 3

2 STANDARDS 3

3 DESIGN CRIERIA 3

4 DESIGN PHILOSOPHY 3

5 DESIGN CALCULATION 4

5.1 LOAD CALCULATION 5

5.2 STAAD INPUT

5.3 STAAD OUTPUT


Client : GULF STEEL WORKS Date : 07/12/21 Sheet no

Project : Gosi Office Park Dsgn By: REV : 0

PGT Job no: Chk By :

BASE PLATE & ANCHOR BOLT DESIGN CALCULATIONS AS PER AISC

Critical Reaction on base plate are (Refer STAAD output)


Node No. = 916
Load Case No. = 101
Vertical Load (FY, P) = 697.0 kN 156.7 kips
Horizontal Load (FX) = 37.0 kN 8.318 kips
Horizontal Load (FZ) = 28.0 kN 6.295 kips
Resultant Shear Force = 46.4 kN 10.43 kips
Maximum tensile force = T = 0.0 kN 0 kips

RCC Column/Pedestal Dimensions


Length l = 406 mm
Width b = 406 mm
Area of concrete support A2 = 164836 mm2 255.5 in2
Specified Comp. Strength of Conc. = f'c = 50 N/mm2 7.11 ksi
Ωc = 2.5

Grade of the base plate : A36


Specified minimum yield strength = 36.3 ksi
Specified minimum yield strength = 36.3 x 6.9
= 250.47 N/mm 2

Base Plate Dimensions


Length of the base plate N = 406 mm (along web) 15.98
Width of the base plate B = 406 mm (along flange 15.98
Thickness of the base plate t = 30 mm
Base plate area (l x b) A1 = 164836 mm2 255.5 in2

Structural Steel Column Size


bf = 280 mm 11.02 in
d = 280 mm 11.02 in

Check for Base Plate Size:


Provided Area of base plate = A1 = 255.496 in2
Provided Area of Pedestal = A2 = 255.496 in2
Required Area of base plate :
1. A1req. = (1/A2) . (P / 0.35 f'c)2 = 15.52 in2
2. A1req. = (P / 0.7 f'c) = 31.48566 in2

3. Aprov. = bf x d = 121.5202 in2

Base plate A1req. < Aprov, Hence OK.


Client : GULF STEEL WORKS Date : 07/12/21 Sheet no

Project : Gosi Office Park Dsgn By: REV : 0

PGT Job no: Chk By :

Check for Bearing Pressure :


Actual bearing pressure = fp = P/(B x N) = 0.613 ksi 4.229 N/mm2

Allowable bearing pressure on support = Fp = 0.35 f'c sqrt(A 2 / A1) <= 0.70 f'c

0.35 f'c sqrt(A2 / A1) = 2.489 ksi &


0.70 f'c = 4.977 ksi
Hence Fp = 2.4885 ksi 17.5 N/mm2
fp <= Fp, Hence Safe
Effective projection of base plate along column depth (web)
m = 70 mm 2.756 in
Effective projection of base plate along column width (Flange)
n = 91 mm 3.583 in
n' = 2.756 mm
q = 4 fp d bf / [(d + bf)2 Fp] <= 1.0 = 0.246
λ shall be lesser of 2 [1 - sqrt(1 - q)] / sqrt(q) & 1.0
2 [1 - sqrt(1 - q)] / sqrt(q) = 0.53152
Hence λ = 0.53152

λ . n' = λ . Sqrt(d.bf)/4 = 1.465 in 37.21 mm


c = max (m, n,λn') = 3.583 in 91 mm
Th. of base plate = tp = 2.c.sqrt(fp / Fy) = 0.931 in 24 mm
Provide base plate thickness as = 30 mm 1.181 in
Hence, OK
Design of Anchor bolts :
Bolt Grade : ASTM-A307, Fu = 60 ksi. (Refer AISC 13th Edition,

Use M 25 bolts
Capacity of bolt in
Tension (Tb) = 60.9 kN Ref Table J3.2, AISC 13th Edition

Shear (Vb) = 32.4 kN Ref Table J3.2, AISC 13th Edition

Nos. of bolt = 4
Tension per bolt (tb) = 0.0 kN tb/Tb = 0.00 <=1 Hence Safe
Shear per bolt (vb) = 11.6 kN vb/Vb = 0.36 <=1 Hence Safe
Resultant of Shear and Tesnion Ratio = 0.358 <= 1.2 Hence Safe
Since bolts are not in tension, provide minimum bolt length.
AS per AISC 13th Edition,
Min. Edge Distance = 32mm Ref. Table J3.4M
Max. Edge Distance = 12xt & Max 150mm Ref Cl. J3.5
Min. Spacing = 3 x bolt dia. i.e. 75mm Ref. Cl. J3.3
Max. Spacing = 300mm Ref Cl. J3.5
Permissible Shear Stress Fnv= 24 ksi (165 MPa) Ref Table J3.2
Permissible Tensile Stress Fnt = 45 ksi (310 Mpa) Ref Table J3.2
Client : GULF STEEL WORKS Date : 07/12/21 Sheet no

Project : Gosi Office Park Dsgn By: REV : 0

PGT Job no: Chk By :


DESIGN CHECK FOR THE
MEMBERS OF BUSINESS
CENTER CANOPY

Das könnte Ihnen auch gefallen