Sie sind auf Seite 1von 7

Hidro DIRECTIONAL

Pnevmo
Tehnika SOLENOID-OPERATED VALVE
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com .. RS 06 .. .. / ..
www.hpt-bg.com
C1
P1_
C1_
C4_
P2
P1_
C2_
C3_
P2
8 C4

)
C2 C3

P[bar]
6

P1_
C1 P1 P2
4
P1_
C2
P2_
C4
2
C2 C3 P2_
C3

0 10 20 30
Q[l/min]

43
TECHNICAL DATA
Nominal pressure bar 200
Nominal flow rate L/min 30
Voltage of operating solenoid VDC 12;24
Port threads G3/8”or G1/2”
All performances and calibration are carried out
by using hydraulic oil with viscosity approx. 46
cSt at 50 °C .Temperature range: -20 °C...+80 °C.
Filtration absolute: 25µm
C1 C4 Tightening torque for solenoid - 25 N.m

On this side it is possible manufacturing of


mounting openings for valve VBD-R-38 type(see
page 5.4).
Performed on clients order only.
P1 P2 C1 C4

P1 P2

It is possible to make blocks with up to 4


directional control valves.A block with 2 valves is
shown.
Tightening torque for detail position 1 - 20+3 N.m
C2 C3 C1
C4

C1
C4

C1
C4

P1 P2

ORDERING CODE 2 RS 06 V 38/12


Nomber of sections: 2,3,4
Operating voltage V:12,24
One section: Omit
With openings for mounting VBD-R-38: V
Without openings for mounting
Type Port threads:38,12
VBD-R-38 (see page 5.4): Omit

Page 1.1
Hidro DIRECTIONAL
Pnevmo
Tehnika SOLENOID-OPERATED VALVE
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com RM 06 ..
www.hpt-bg.com

C2 C3
C1
C4

C1
C2 C3 C4

P1 P2

P1_
C1_
C4_
P2
P1_
C2_
C3_
P2
8

)
P[bar]
6

4 P1_
C1;P1_
C2
C1 C4 P2_
C4;P2_
C3
2

0 10 20 30
Q[l/min]
C1 C4

TECHNICAL DATA
Nominal pressure bar 200
Nominal flow rate L/min 40
Voltage of operating solenoid VDC 12;24

All performances and calibration are carried out


by using hydraulic oil with viscosity
Approx. 46 cSt at 50 °C .
P1 Temperature range: -20 °C...+80°C
Filtration absolute: 25µm
P2 Tightening torque for solenoid - 25 N.m

ORDERING CODE RM 06 /12

Type Operating voltage V:12,24

Page 1.2
Hidro DIRECTIONAL
Pnevmo
Tehnika SOLENOID-OPERATED VALVE
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com RS 10 ..
www.hpt-bg.com

C1

C2 C3 C4
C3
P1 P2
C2
10

)
P[bar]
P1_
C1_
C4_
P2
8 P1_
C2_
C3_
P2

6 P1_
C1;P1_
C2
P2_
C4;P2_
C3
4

0 20 40 60
Q[l/min]

C4
TECHNICAL DATA
C1 Nominal pressure bar 200
Nominal flow rate L/min 50
Voltage of operating solenoid VDC 12;24

All performances and calibration are carried out


by using hydraulic oil with viscosity
P1 Approx. 46 cSt at 50 °C
P2 Temperature range: -20°C...+80°C.
Filtration absolute: 25µm
Tightening torque for solenoid - 30 N.m

It is possible to make block swith up to 4


directional control valves.
A block with 2 valves is shown.
Tightening torque for detail position 1 - 20+3 N.m
C2 C3 C1
C4

C1
C4

C1
C4

P1 P2

ORDERING CODE
2 RS 10/12
Nomber of sections: 2,3,4
Operating voltage V:12,24
One section: Omit

Type

Page 1.3
Hidro HYDRAULIC DIRECTIONAL VALVE
Pnevmo
Tehnika WITH AUTOMATIC SWITCHING
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com 4/2 RHA 06/20
www.hpt-bg.com

A B

P T

16
P

)
P[bar]
À,B_
T
A B
12

8 P_
A,B

T 4

0 10 20 30 40
Q[l/min]

TECHNICAL DATA
Working pressure Pw bar 50…210
Flow rate L/min 3…40
Pressure adjustment of relief Pw+10%Pw
valves position 1

Working fluid - mineral oil with viscosity


from 10 to 400 cSt at 50 °C .
Temperature range: -20°C...+80°C.
Filtration absolute: 25µm .
Initial switching of directional control valve
- by push pins position 2 .
Mounting plate-
acc. To ISO 4401-AB-03-4A(CETOP3)
Tightening torque of connecting screws on the
mounting plate - 8.5 N.m

Page 1.4
Hidro HYDRAULIC DIRECTIONAL VALVE
Pnevmo
Tehnika WITH AUTOMATIC SWITCHING
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com 4/2 RHA 10/20
www.hpt-bg.com

A B

P T

P 16

A B

)
P[bar]
12 À,B_
T

8 P_
A,B
T T
4

0 20 40 60 80
Q[l/min]

TECHNICAL DATA
Working pressure Pw bar 50…210
Flow rate L/min 3…80
Pressure adjustment of relief Pw+10%Pw
valves position 1

Working fluid - mineral oil with viscosity from


10 to 400 cSt at 50 °C .
Temperature range: -20°C...+80°C.
Filtration absolute: 25µm .
Initial switching of directional control valve
- by push pins position 2 .
Mounting plate-
acc. To ISO 4401-AB-05-4A(CETOP5)
Tightening torque of connecting screws on the
mounting plate - 14 N.m

Page 1.5
Hidro HYDRAULIC DIRECTIONAL VALVE
Pnevmo
Tehnika WITH AUTOMATIC SWITCHING
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com 4/2 RHA 06/20A
www.hpt-bg.com

A TP T B

A B
T 32

)
P[bar]
B_
T
24
A_
T
P_
B
16 P_
A

0 20 40 60 80
Q[l/min]

TECHNICAL DATA
Working pressure bar 30…210
Flow rate L/min 3…40

Working fluid - mineral oil with viscosity from


10 to 400 cSt at 50 °C .
Temperature range: -20°C...+80°C.
Filtration absolute: 25µm .
Mounting plate
acc. To ISO 4401-AB-03-4A(CETOP3)
Tightening torque of connecting screws on the
mounting plate - 8.5 N.m

Page 1.6
Hidro HYDRAULIC DIRECTIONAL VALVE
Pnevmo
Tehnika WITH AUTOMATIC SWITCHING
3,Vojeli St., Kazanlak, Bulgaria
Tel.: +359 431/ 62 228
Fax : +359 431/ 62 019
e-mail : info@hpt-bg.com 4/2 RHA 10/20A
www.hpt-bg.com

A TP T B

P
A B
16

)
P[bar]
À,B_
T
T T 12

8 P_
A,B

0 20 40 60 80
Q[l/min]

TECHNICAL DATA
Working pressure bar 30…210
Flow rate L/min 3…80

Working fluid - mineral oil with viscosity from 10


to 400 cSt at 50 °C .
Temperature range: -20°C...+80°C.
Filtration absolute: 25µm .
Mounting plate-
acc. To ISO 4401-AB-05-4A(CETOP5)
Tightening torque of connecting screws on the
mounting plate - 14 N.m

Page 1.7