• Title Change
• Chapter 1 – Performance Goals
– Service & Function
– Reliability Targets
– Updated Hazard Maps
• New Chapter on Tsunami Loads
• New Appendix on Fire Effects
• Complete Revision of Seismic Response History
Analysis Procedures
• New Seismic Site Class Coefficients
• New Cladding Wind Pressure Coefficients
1
10/30/2017
Chapter 1
Performance
Goals
2
10/30/2017
1.3.3 Functionality
• Risk category IV structures and systems designed to
provide reasonable probability of functionality given any
of the design level hazards (ice, flood, rain, seismic,
snow, tsunami, wind)
• Affects:
– Outdoor generators
– Radio communications towers
– Roof-mounted HVAC (if necessary for function)
3
10/30/2017
4
10/30/2017
Updated Hazard
Maps
10
5
10/30/2017
Wind Maps
• ASCE 7-10 • ASCE 7-16
11
Snow Maps
6
10/30/2017
Snow Maps
Chapter 6
Tsunami
7
10/30/2017
Scope
8
10/30/2017
Design Evaluations
• Design for:
– Hydrodynamic forces
– Buoyancy
– Waterborne debris impact
• Load Case 1
– Maximum inundation depth + buoyancy
• Load Case 2
– 2/3 Maximum inundation depth
– Maximum velocity
• Load Case 3
– Maximum inundation depth
– 1/3 maximum velocity
9
10/30/2017
Evaluation Approach
Chapter 12
Seismic
10
10/30/2017
Sa(T)
SDS
SD1/T
SD1
SD1TL/(T)2
0.2 1 TL T
2
3
2
3
Sa(T) SD1
SDS Sa(T)
SDS
SD1/T SD1/T
SD1
SD1TL/(T)2
SD1TL/(T)2
0.2 1 TL T 0.2 1 TL T
11
10/30/2017
• Exceptions
– Site Class E,
• Site Class “C” Fa is used
– Site Class D,
• ⁄ for values of T< 1.5Ts
• Cs factored by 1.5 for T>1.5TS
24
12
10/30/2017
Chapters 26-30
Wind
13
10/30/2017
27
2010 2016
14
10/30/2017
Appendix E
Fire Effects
Appendix
Fire Effects
15
10/30/2017
On-line
Hazard Tool
16
10/30/2017
Summary
Thank you!
17