 Safety Precautions

DATA SHEET ► Safety Precautions is for using the product safely and correctly in order to prevent
Related Manual
Read this data sheet carefully prior to any operation, mounting, installation or start-up of
2. Performance Specifications

the accidents and danger, so please go by them. the product. Item Performance specification
LS Programmable Logic Controller ► The precautions explained here only apply to this module. For safety precautions Name ode Number of channel 2 channels
on the PLC system, refer to User‟s manual. XGB analog 10310000920 Type Voltage Current
Analog Input Option Board ► The precautions are divided into 2 sections, „Warning‟ and „Caution‟. Each of the
XGK/XGB Instruction & Programming 10310000754 DC 0 ~ 10V DC 4 ~ 20㎃
XG5000 10310000512 Analog (input resistance: DC 0 ~ 20㎃
meanings is represented as follows. XGB Hardware 10310000926 input Range 1㏁ or above) (input resistance: 250Ω)
Input range can be see at user program or I/O
If you violate instructions, it can cause death, fatal injury or a parameter per each channel-Note1)
XGB XBO-AD02A Warning considerable loss of property Revision History
Form 12 bit binary data
Date Version Updated Information
Unsigned 0 ~ 4000
2011.01 V1.0 First Edition
If you violate instructions, it can cause a slight injury or a slight Digital Signed -2000 ~ 2000
2011.05 V1.1 CI changed
Caution loss of products
output Range Precise
value
0 ~ 1000 (DC 0 ~10V)
400~2000 (DC 4~20㎃)
0 ~ 2000 (DC 0~20㎃)
Applicable version Percentile 0 ~ 1000
► The symbols which are indicated in the PLC and User‟s Manual mean as follows. For system configuration, the following version is necessary. 1/4000 (DC 4~20㎃: 1/3200)
This symbol means paying attention because of danger of injury, fire, Segment Version Max. resolution 5㎂ (DC0~20㎃)
2.5mV (DC 0 ~10V)
or malfunction XGB E type V1.1 or above 6.25㎂ (DC 4~20㎃)
► This symbol means paying attention because of danger of electric shock. XGB S type V1.1 or above Precision ±1.0% or less
Store this datasheet in a safe place so that you can take it out and read XGB SU type V1.0 or above Max. conversion speed 1ms/channel + scan time
it whenever necessary. Always forward it to the end user XG5000 V3.61 or above Absolute max. input DC +12V / -10V DC ±25㎃
Additional Average function Count average (2~64,000 times)
 Handling Precautions function Gain adjust Gain adjust (-40~40)
Non-insulation between analog input channels
► Don‟t drop or make impact. Insulation method Non-insulation between input terminal and PLC
► Don‟t detach PCB from case. It may cause problem. basic unit
► When wiring, let no foreign material go into the module. If it goes into the module, Input terminal 5-point terminal block
remove it. I/O points occupied Fixed type: 64 point
► Don‟t detach the module from slot while power is on 1EA(When using XBC-DR10E/DR14E “E” type)
Max. no. of installation 2EA (When using XBC-DR20E/DR30E “E” type)
2 EA(When using XBC-DxxxS/SU “S” type)
Supply power Internal DC5V
- When using LSIS equipment, thoroughly read this Warning Consumption current 50㎃
datasheet and associated manuals introduced in this Weight 20g
► Do not contact the terminals while the power is applied.
datasheet. Also pay careful attention to safety and handle Risk of electric shock and malfunction.
Remarks
the module properly. ► Protect the product from being gone into by foreign metallic matter.
Note1) Offset/gain value on the analog input range can be adjusted at XG5000 I/O
- Store this datasheet in a safe place so that you can take it Risk of fire, electric shock and malfunction.
parameter
out and read it whenever necessary. ► Risk of fire, electric shock and malfunction.
Risk of injury and fire by explosion and ignition.

1.General Specifications
 HEAD OFFICE Caution
LS tower, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do No Item Specification Standard
1026-6, Korea http://eng.lsis.biz ► Be sure to check the rated voltage and terminal arrangement for the Operating
module before wiring work. 1 temperature
0 ~ 55℃ -
Tel: 82-2-2034-4870 Fax: (82-2)2034-4648 e-mail: cshwang@lsis.biz
Risk of electric shock, fire and malfunction. Storage
2 temperature
-25 ~ 70℃ -
 LSIS(ME) FZE _ Dubai, U.A.E. ► Tighten the screw of terminal block with the specified torque range.
Operating
Tel: 971-4-886-5360 Fax: 971-4-886-5361 e-mail: jungyongl@lsis.biz If the terminal screw is loose, it can cause fire and electric shock. 3 5 ~ 95%RH, non-condensing -
humidity

.
► Use the PLC in an environment that meets the general Storage
4 5 ~ 95%RH, non-condensing -
 LSIS Tokyo Office _ Tokyo, Japan specifications contained in this datasheet. humidity
Risk of electrical shock, fire, erroneous operation and deterioration of the For discontinuous vibration - -
Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz
PLC. Frequency Acceleration Amplitude times
10≤f∠57 Hz - 0.075 mm
 LSIS Shanghai Office _ Shanghai, China ► Be sure that external load does not exceed the rating of output Vibration 57 ≤f≤150 Hz 9.8㎨ (1G) - 10 times in
module. 5 each
Tel: 86-21-5237-9977(609) Fax: 89-21-5237-7189 e-mail: liyong@lsis.com.cn resistance For continuous vibration IEC61131-2
direction
Risk of fire and erroneous operation. Frequency Acceleration Amplitude for
 LSIS Beijing Office _ Beijing, China ► Do not use the PLC in the environment of direct vibration 10≤f∠57 Hz - 0.035 mm X, Y, Z
Risk of electrical shock, fire and erroneous operation. 57≤f≤150 Hz 4.9㎨(0.5G) -
Tel: 86-10-5825-6027(666) Fax: 86-10-5825-6028 e-mail: xunmj@lsis.com.cn
 Max. impact acceleration : 147 ㎨ (15G)
► Do not disassemble, repair or modify the PLC. Shocks  Authorized time : 11㎳
6 IEC61131-2
 LSIS Guangzhou Office _ Guangzhou, China Risk of electrical shock, fire and erroneous operation resistance  Pulse wave : Sign half-wave pulse
Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 e-mail: chenxs@lsis.com.cn ► When disposing of PLC and battery, treat it as industrial waste. (Each 3 times in X,Y,Z directions)
Square wave AC: ±1,500V LSIS
Risk of poisonous pollution or explosion.
impulse noise DC: ±900V standard
 LSIS Chengdu Office _ Chengdu, China Electrostatic IEC61131-2
Tel: 86-20-8328-6754 Fax: 86-20-8326-6287 e-mail: comysb@lsis.biz Voltage: 4kV (Contact discharge)
discharge IEC61000-4-2
 Precautions for use Radiated
IEC61131-2
► Do not Install other places except PLC controlled place. Noise electromagnetic 80 ~ 1,000 MHz, 10 V/m
 LSIS Qingdao Office _ Qingdao, China 7 IEC61000-4-3
► Make sure that the FG terminal is grounded with class 3 grounding which is resistance field noise
Tel: 86-532-8501-6068 Fax: 86-532-8501-6057 e-mail: wangzy@lsis.com.cn Digital/analog
dedicated to the PLC. Otherwise, it can cause disorder or malfunction of PLC Power
input/output
Fast transient Segment supply IEC61131-2
 LSIS Europe B.V., Netherlands PLC Others PLC Others PLC Others /burst noise module
communication
IEC61000-4-4
Tel: +31 (0)20 654 1420 Fax: +31(0)20 654 1429 e-mail: junshickp@lsis.biz interface
Voltage 2 kV 1 kV
Ambient
A) Best B) Good C) Bad 8 No corrosive gas or dust -
conditions
► Connect expansion connector correctly when expansion module is needed. Operating
9 2000m or less -
height
► Do not detach PCB from the case of the module and do not modify the module.
Pollution
LS constantly endeavors to improve our products so that information in this ► Turn off power when attaching or detaching module. 10 2 or less -
degree
datasheet is subject to change without notice. ► Cellular phone or walkie-talkie should be farther than 30cm from the PLC. Cooling
11 Natural air cooling -
The date of issue: 2011. 5 ► Input signal and communication line should be farther than10cm from a high- type
10310001187 Ver 1.1 tension and a power line in order not to be affected by noise and magnetic field.

3. Parts Name and Descriptions 4. Wiring 5. Internal memory 7. Dimension (㎜)


(1) Precautions for wiring (1) Analog/digital conversion data I/O area
(a) Don‟t let AC power line near to analog input module‟s external output signal line. Read/ Signal
Variable type Device Comment
With an enough distance kept away between, it will be free from surge or inductive Write direction
35.0mm _0x_ERR BIT U0x.00.0 Module Error
① Hook for fixation noise.
_0x_RDY BIT U0x.00.F Module Ready
(b) Cable shall be selected in due consideration of ambient temperature and allowable
_0x_AD0_ACT BIT U0x.01.0 CH0 Active
49.0mm
current. More than AWG22 (0.3㎟) is recommended.
_0x_AD1_ACT BIT U0x.01.1 CH1 Active
(c) Don‟t let the cable too close to hot device and material or in direct contact with oil for _0X_AD0_IDD BIT U0x.01.4 CH0 Disconnection flag Option →
long, which will cause damage or abnormal operation due to short-circuit. Read
② Terminal block _0X_AD1_IDD BIT U0x.01.5 CH1 Disconnection flag CPU
(d) Check the polarity when wiring the terminal. _0x_AD0_ERR BIT U0x.01.8 CH0 error
(e) Wiring with high-voltage line or power line may produce inductive hindrance causing _0x_AD1_ERR BIT U0x.01.9 CH1 error
10.3mm ③ Cover abnormal operation or defect. _0x_AD0_DATA WORD U0x.04 CH0 Output
(f) Enable the channel that you want to use _0x_AD1_DATA WORD U0x.05 CH1 Output

(2) Wiring example Remarks


④ Hook for fixation
Example of wiring with external device How to express U device
⑤ Connector for U0x.00.0
option board
⑥ Input XBO-AD02A Bit no.
connector (a) Current input
V0+ R Slot Word no.
*(a) *(b) Ex1) CH0 Output of the module at slot 9 -> U09.04
+ CH0 Ex2) CH0 disconnection flag of the module at slot 9 -> U09.01.4
No. Name Description I0+ R
①,④ Hook for fixation ▶ Hook for fixing the option board to basic unit 전류 입력 R
-
▶ Wiring terminal block to connect with external (2) Analog/digital operation parameter setting area
② Terminal block
device(Analog input) Memory address
③ Cover ▶ Option board cover Hex Dec
Description Read/Write Instruction
Connector for ▶ Connection connector for connecting the option
⑤ 0H 0 Enable channel
option board board to the basic unit (b) Voltage input 1H 1 Input range setting
▶ Wiring connector for connecting with the external V1+ R
⑥ Input connector 2H 2 Output data type setting
device + CH1
*(c) Input channel 0 count
I1+ R 3H 3 PUT
average value setting Read/Write
- R GET
Input channel 1 count
4H 4
averaging value setting
COM 9H 9 Input channel 0 gain weighting
AH 10 Input channel 1 gain weighting
DH 13 Setup error information Read GET

Remarks
*(a) In case of current input, connect V+ terminal and I+ terminal
*(b) Input resistance of current input circuit is 250 Ω (typ.)
*(c) Input resistance of voltage input circuit is 1 MΩ (min.)

6. Error code 8. Warranty


(1) It saves error code detected when setting (in case of setting by program) (1) Warranty period
(2) Setting error is canceled when setting goes in the normal range by re-setting LSIS provides an 18-month-warranty from the date of the production.
(3) When U0X.01.8~ U0X.01.9 (setting error flag) is on, check this area and fix the (2) Warranty conditions
corresponding setting to cancel the error For troubles within the warranty period, LSIS will replace the entire PLC or repair
(4) When using GET instruction, setting error address is as follows. the troubled parts free of charge except the following cases.
Error (a) The troubles caused by improper condition, environment or treatment except
Type Description Priority Remark
code the instructions of LSIS.
10# Input CH range setting error 1 (b) The troubles caused by external devices.
Setting 20# Input CH data type setting error 2 # means CH No. (c) The troubles caused by remodeling or repairing based on the user‟s own
error 30# Input CH count average setting error 3 Input ch0,1
discretion.
40# Input CH gain weighting setting error 4
(d) The troubles caused by improper usage of the product.
(5) When more than one error occurs, it saves error code having higher priority.
(e) The troubles caused by the reason which exceeded the expectation from
science and technology level when LSIS manufactured the product.
(f) The troubles caused by natural disaster.
(3) This warranty is limited to the PLC itself only. It is not valid for the whole system
which the PLC is attached to.