Sie sind auf Seite 1von 4

Messgeräte Sonstige Daten

Spectrometer
Probes

spectro::lyser™
i::scan

spectro::lyser™ UV monitors depending on the application an individual


Ionselective
Probes

selection of: NO3 -N, COD, BOD, TOC, DOC, UV254, NO2 -N, BTX,
fingerprints and spectral alarms, temperature and pressure 44
spectro::lyser™ UV-Vis monitors depending on the application an
individual selection of TSS, turbidity, NO3 -N, COD, BOD, TOC, DOC,
Physical Probes

UV254, color, BTX, O3, H2S, AOC, fingerprints and spectral alarms,

181,5
temperature and pressure

∙∙ s::can plug & measure


∙∙ measuring principle: UV-Vis spectrometry over the total
Terminals

0,5 - 15
range (220-720 nm or 220-390 nm)
547

∙∙ multiparameter probe with adjustable open path length


∙∙ ideal for surface water, ground water, drinking water and
waste water
∙∙ long term stable and maintenance free in operation
Software

∙∙ factory precalibrated, local multi-point calibration possible


∙∙ automatic cleaning with compressed air
∙∙ mounting and measurement directly in the media (InSitu)
Configuration

or in a flow cell (monitoring station)


System

∙∙ operation via s::can terminals & s::can software


∙∙ cleaning integrated, easy mounting without clogging
~86

∙∙ recomended by and complient with public authorities and


international agencies such as Chinese EPA, US EPA and
Monitoring
Stations

CPCB

recommended accessories
part number article name
Spare Parts &
Accessories

A-500-s Inserts for optical pathlength 0.5 mm, stainless steel


A-001-s Inserts for optical pathlength 1 mm, stainless steel
A-002-s Inserts for optical pathlength 2 mm, stainless steel
A-005-s Inserts for optical pathlength 5 mm, stainless steel
A-015-s Inserts for optical pathlength 15 mm, stainless steel
B-32-xxx s::can compressor
B-44 cleaning valve
Services &
Solutions

B-44-2
B-61-1 cleaning agent
C-210-spectro 10 m extension cable for s::can™ spectrometer probes
D-315-xxx con::cube
F-110-spectro carrier s::can™ spectrometer probe
F-120-spectro carrier s::can™ spectrometer probe
F-48-spectro s::can spectrometer flow-cell (by-pass setup), PVC © s::can Messtechnik GmbH
S-11-xx-moni moni::tool Software

1
technical specification
measuring principle UV-Vis spectrometry 220 - 720 nm cable length 7.5 m fixed cable (-075) or
UV spectrometry 220 - 390 nm 1 m fixed cable (-010)

Spectrometer
measuring principle detail xenon flash lamp, 256 photo diodes cable type TNPU jacket

Probes
automatic compensation instrument two beam measurement, complete housing material stainless steel 1.4404
spectrum weight (min.) 3,4 kg (incl. cable)
automatic compensation cross turbidity / solids / organic dimensions (diameter x length) 44 x 612 mm / 698 mm
sensitivities substances operating temperature 0 ... 45 °C
precalibrated ex-works all parameters storage temperature -10 ... 50 °C
accuracy standard solution (>1 mg/l) NO3 -N: +/- 2% +1/OPL[mg/l]* operating pressure 0 ... 3 bar
COD-KHP: +/-2% +10/OPL[mg/l]* high pressure specification 10 bar

i::scan
(* OPL … optical pathlength in mm)
explosion proof specification ATEX according to EN60079-0
access to raw signals access to spectral information (optional)
reference standard distilled water installation / mounting submersed or in a flow cell
onboard memory 656 KB flow velocity 9.843 ft/sec (max.)
integrated temperature sensor -10 ... 50 °C mechanical stability 30 Nm
resolution temperature sensor 0.1 °C ingress protection class IP68

Ionselective
integrated pressure sensor (optional) 0 ... 1,2/2/11 bar automatic cleaning media: compressed air

Probes
resolution pressure sensor 1:1000 of measuring range permissible pressure: 4 ... 6 bar
integration via con::nect air volume: 7 ... 20 l per cleaning
con::cube duration: 1 ... 5 sec. per cleaning
power supply 11 … 15 VDC cleaning interval: every 1st to 10th
power consumption (typical) 4.2 W measuring interval
power consumption (max.) 20 W delay: 10 … 30 sec.

Physical Probes
interface to s::can terminals MIL connector (IP67), RS485 conformity - EMC EN 61326-1, EN 61326-2-3
interface to third party terminals con::nect incl. gateway modbusRTU conformity - safety EN 61010-1
extended warranty (optional) 3 years

Terminals
Software
Configuration
System
Monitoring
Stations
Spare Parts &
Accessories
Services &
Solutions

© s::can Messtechnik GmbH

2
© s::can Messtechnik GmbH

3
Spectrometer i::scan Ionselective Physical Probes Terminals Software System Monitoring Spare Parts & Services &
Probes Probes Configuration Stations Accessories Solutions
municipal WWTP influent & sewer
typical concentration ranges for this application

Spectrometer
TSS NO3 -N COD CODf BOD UV254 UV254f H2S part number
[mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [Abs/m] [Abs/m] [mg/l]

Probes
spectro::lyser™ UV-Vis min. 0 0 0 0 0 0 Sp1‑002‑p0‑sEX-010 / -075
(TSS, NO3 -N, COD, BOD, max. 3000 40 3750 2000 1250 750 (incl. Global Calibration i3)
UV254, UV254f)
spectro::lyser™ UV-Vis min. 0 0 0 0 0 0 Sp1‑002‑p0‑sNO-010 / -075
(TSS, NO3 -N, COD, CODf, max. 3000 40 3750 1250 1250 750 (incl. Global Calibration i1)
UV254, UV254f)
spectro::lyser™ UV-Vis min. 0 0 0 0 0 0 Sp1‑002‑p0‑sNO-010 / -075

i::scan
(TSS, NO3 -N, COD, H2S, max. 3000 40 3750 1250 750 25 (incl. Global Calibration i5)
UV254, UV254f)

diary WWTP influent


typical concentration ranges for this application
TSS NO3 -N COD CODf UV254 UV254f part number

Ionselective
[mg/l] [mg/l] [mg/l] [mg/l] [Abs/m] [Abs/m]

Probes
spectro::lyser™ UV-Vis min. 100 0 200 100 0 0 Sp1‑001‑p0‑sNO-010 / -075
(TSS, NO3 -N, COD, CODf, max. 3000 80 12500 5000 2500 1500 (incl. Global Calibration m1)
UV254, UV254f)

paper mill WWTP influent

Physical Probes
typical concentration ranges for this application
TSS COD CODf UV254 UV254f part number
[mg/l] [mg/l] [mg/l] [Abs/m] [Abs/m]
spectro::lyser™ UV-Vis min. 0 875 875 0 0 Sp1‑002‑p0‑sNO-010 / -075
(TSS, COD, CODf, UV254, max. 2500 5000 4250 1250 750 (incl. Global Calibration p1)
UV254f)

brewery WWTP influent

Terminals
typical concentration ranges for this application
TSS COD UV254 UV254f part number
[mg/l] [mg/l] [Abs/m] [Abs/m]
spectro::lyser™ UV-Vis min. 0 500 0 0 Sp1‑002‑p0‑sNO-010 / -075
(TSS, COD, UV254, UV254f) max. 5000 45000 1250 750 (incl. Global Calibration b1)

Software
Configuration
System
Monitoring
Stations
Spare Parts &
Accessories
Services &
Solutions

© s::can Messtechnik GmbH