Hardware Quality Standard for Huawei product use only

HUAWEI Technologies Co., LTD


Hardware Quality Standard
Direction for Use
1 Intention
This standard is used for control Huawei equipment’s hardware quality by customer. In order to easily to clear
hardware quality requirement between customer and Huawei Technologies Co., Ltd., to assure the
engineering quality accord with customer’s requirement and equipment running safety for long time.
2 Using confine
This standard use for customer inspect all the equipment hardware installation quality of Huawei .
3 Using general rules
The standard should be used with equipment installation manual, it can be used to check and control the
Huawei equipment’s hardware quality ,if it collide with customer’s requirement please according to the result
negotiated with customer.
4 The “remark” item please fill the quality problem and reason
5 This standard is explained by Huawei Technologies Co., Ltd.

installation of Rack(cabinet)
S/N Check content Check method OK NO Remark
The rack (cabinet) shall be placed according to Check
1 the engineering design document. installation
position
The rack (cabinet) shall be installed firmly. Check.
2 Inclosure made by customer should be installed
accord with customer’s requirement.
Configuration inclosure of cabinet shall be According to
installed correctly and firmly. without paint break hardware
3
off and distort. installation
manual.
4 All of the bolt shall be installed firmly. Look over.
5 Board can be plugged and pulled out easily. Look over.
Racks’s vertical according to the engineering Survey.
6
design document.
For the cabinets, the doors facing the main Survey.
7 corridors shall be aligned to the same straight
line.
The rack surfaces in a row should be completely Look over.
8
in a plane.

2008-01-14 For internal use only Page 1 of 4


Confidentiality
level: For internal
Hardware Quality Standard for Huawei product use only

Waterproof and anticorrosive Look over.

9 measures should be adopted for


outdoor equipment.
The labels of rack shall be placed neat and Look over.
10
clean.

installation of Signal cables


S/N Check content Check method OK NO Remark
The signal cable should be arranged according Look over.
1 to engineering design document. Convenient to
maintenance and expansion.
2 No damage or rupture in signal cable. Look over.
The plug of signal cable should be tidy Look over.
3 without damage, the plug connected correctly
and firmly.
Arrange the cables in an orderly and Look over.
good-looking way, the cables shall be bundled
4 with evenly distributed space and proper
tightness, cable arranged at cable trough can be
allowed without bundling.
Signal cables should be arranged straight or Look
flatly, neatly without crossing (cable are allowed over(crossing
5 to be crossed within 1m outside cabinet), there allowed within
is somewhat longer than necessary at the 1m outside rack)
bending point.
When the tail fiber cable is led out of the Look over.
6
cabinet, it should be protected.
No broken and bending in the surface of feeder Look over.
7 cable feeder cable should be fixed firmly and
dealed with waterproof before into room.
Cable’s label should be filled in correctly and Look over.
8
placed neatly and firmly.

installation of Terminals and antenna .etc


S/N Check content Check method OK NO Remark
The work station, alarm box and inverter .etc Look over.
equipments should be placed according to
1
engineering design document, the plug
connected properly and firmly.
WS outer case, UPS (or inverter) and other Look over.
2 equipment should connect to protection
grounding (PGND).

2008-01-14 For internal use only Page 2 of 4


Confidentiality
level: For internal
Hardware Quality Standard for Huawei product use only

Antennae shall be installed firmly according to Look over.


3
engineering design document.
Labels of WS and network management .etc Look over.
4
shall be placed neatly and firmly.

power and grounding


S/N Check content Check method OK NO Remark
Power equipment shall be installed according to Look over.
1
engineering design document.
Power cable and grounding cable arrangement Look over.
should accord with engineering design
2
document and easily to expansion or
maintenance.
The power cable or wire and grounding cable or Look over.
wire shall be made from an intact section of
3
copper core materials without any cut, no
broken in cable’s shuck.
Power cables and grounding cables shall be Look over.
4
connected correctly and firmly.
The radius of power cables, grounding cable Look over.
should be enough to assure equipment’s
5
power requirement according to engineering
design document.
The signal cable must be tired separately from Look over.
6
power cable.
Power cables and grounding cables Look over.
arrangement should be in straight running and
7
firm bundling. There is somewhat longer than
necessary at bending point.
The labels of power cable or grounding cable Look over.
8 shall be filled in correct and placed firmly and
neatly according with criterion.

installation of Environment of Equipment


S/N Check content Check method OK NO Remark
Condition of equipment room can assure Make sure by
1
equipments running safety for long time. customer.
Parameter of power in the equipment room can Make sure by
2
assure equipments running safety for long time. customer.
The cable distribution frame should be Make sure by
3 grounded firmly. The shielding layer of customer.
subscriber external cable must be grounded.
4 Protection grounding cable of DC or AC Make sure by

2008-01-14 For internal use only Page 3 of 4


Confidentiality
level: For internal
Hardware Quality Standard for Huawei product use only

power system should be connected firmly customer.


grounding mode for equipment room should be
selected jointed grounding.
The joint grounding resistance value Make sure by

should be satisfy the design customer.


5
requirements. Generally, it should be
less than 10 ohm,
The radius and power supply mode of PGND Make sure by
cable, GND cable of primary power and -48V customer.
power cable that connected to PDF or
6
distribution power box according to engineering
design document. They can assure equipment
running safely and expansion request.
PDF and primary power output current-limiting Make sure by
7
fuse must be as specified. customer.
Power cable arrange outside should avoid Look over.
8 impracticable into equipment room and should
be protected lightning.

others
S/N Check content Check method OK NO Remark
Equipment hardware installation inspection is Look over and
normal before power on. survey (board
tape ,power
1 voltage and
power exist
short circuit or
not).
No sundries inside rack, the spare articles left Look over.
2 after installation must be placed somewhere
neatly.
The signal cables for expansion shall be Look over.
bundled or connected at the oblgate position
3
inside cabinet, easy to expension or
maintenance in the future and avoid missing.
The connectors have not been used should be Look over.
4
protected with protection cap.
Another hardware installation quality:
5

2008-01-14 For internal use only Page 4 of 4