On August 24, 2012, we were informed by Henkel Loctite of their plans to revise the formula of their 401,
406, 454, and 495 products. This reformulation is an enhancement that will increase the upper temperature
resistance of these products from 180°F to 250°F. Shipments of the new formulation should begin in late
Q1, 2012. All product labels will be clearly marked to identify packages containing the new formulation.

Henkel Loctite has stated that the overall composition of these products has changed by less than 1%, and
that all other aspects of performance, application, and physical properties should remain unchanged.

This will also not affect MSDSs, product part numbers, Loctite material specifications, QC testing,
Certificates of Analysis, shipping and transportation classifications, shelf life, or storage conditions. The
only document that will be changed is the Technical Data Sheets, which are included with this notification.

We don’t expect this to have any impact on your business or your interaction with Ellsworth. As always, we
just want to make sure that you are kept up to date on any changes we are made aware of. For more details,
please see the attached letter from Henkel Loctite.

Our Engineered Sales Representatives and Customer Service Representatives are available to help with any
questions you may have. Please call 1-800-888-0698 to get in touch with your local representative.

We apologize for any inconvenience this may cause and will work with you in any way necessary to facilitate a
smooth transition that will meet your current needs.

Sincerely,

Jake Bauer
Quality Manager
Ellsworth Adhesives Specialty Chemical Distribution

W129 N10825 Washington Drive Germantown, WI 53022


Phone: (262) 253-8600 | Fax: (262) 253-8619 | Toll Free: (800) 888-0698
COMPLETELY ENGINEERED SYSTEMS FROM MATERIAL SPECIFICATIONS TO APPLICATION METHODS
Technical Data Sheet

LOCTITE® 401™
(TDS for new formulation of Loctite® 401™) February-2012

PRODUCT DESCRIPTION below shows the fixture time achieved on different materials
LOCTITE® 401™ provides the following product at 22 °C / 50 % relative humidity. This is defined as the time to
characteristics: develop a shear strength of 0.1 N/mm².
Fixture Time, seconds:
Technology Cyanoacrylate
Steel <5
Chemical Type Ethyl cyanoacrylate
Aluminum <5
Appearance (uncured) Transparent, colorless to straw Neoprene <5
colored liquidLMS Rubber, nitrile <5
Components One part - requires no mixing ABS <5
Viscosity Low PVC <5
Cure Humidity Polycarbonate 5 to 10
Application Bonding Phenolic <5
Key Substrates Metals , Plastics and Elastomers Wood (balsa) <5
Wood (oak) 15 to 30
Wood (pine) 15 to 20
This Technical Data Sheet is valid for LOCTITE® 401™ Chipboard <5
manufactured from the dates outlined in the Fabric 10 to 20
"Manufacturing Date Reference" section. Leather 15 to 30
Paper <5
LOCTITE® 401™ is designed for the assembly of difficult-
to-bond materials which require uniform stress distribution and
strong tension and/or shear strength. The product provides Cure Speed vs. Bond Gap
rapid bonding of a wide range of materials, including metals, The rate of cure will depend on the bondline gap. Thin bond
lines result in high cure speeds, increasing the bond gap will
plastics and elastomers. LOCTITE® 401™ is also suited for
decrease the rate of cure.
bonding porous materials such as wood, paper, leather and
fabric.
Cure Speed vs. Humidity
NSF International The rate of cure will depend on the ambient relative humidity.
Registered to NSF Category P1 for use as a sealant where Higher relative humidity levels result in more rapid speed of
there is no possibilty of food contact in and around food cure.
processing areas. Note: This is a regional approval. Please
contact your local Technical Service Center for more
information and clarification. Cure Speed vs. Activator
Where cure speed is unacceptably long due to large gaps,
applying activator to the surface will improve cure speed.
TYPICAL PROPERTIES OF UNCURED MATERIAL However, this can reduce ultimate strength of the bond and
Specific Gravity @ 25 °C 1.1 therefore testing is recommended to confirm effect.
Flash Point - See MSDS

Viscosity, Cone & Plate, mPa·s (cP):


Temperature: 25 °C, Shear Rate: 3,000 s-1 70 to 110LMS
Viscosity, Brookfield - LVF, 25 °C, mPa·s (cP):
Spindle 1, speed 30 rpm 100 to 120

TYPICAL CURING PERFORMANCE


Under normal conditions, the atmospheric moisture initiates the
curing process. Although full functional strength is developed
in a relatively short time, curing continues for at least 24 hours
before full chemical/solvent resistance is developed.

Cure Speed vs. Substrate


The rate of cure will depend on the substrate used. The table
TDS LOCTITE® 401™, February-2012

TYPICAL PERFORMANCE OF CURED MATERIAL Heat Aging


Adhesive Properties Aged at temperature indicated and tested @ 22 °C
125 60 °C
Cured for 10 seconds @ 22 °C

% Initial Strength @ 22 °C
Tensile Strength, ISO 6922:
Buna-N N/mm² ≥6.9LMS 100
(psi) (≥1,000)
100 °C
75
Cured for 72 hours @ 22 °C 80 °C
Tensile Strength, ISO 6922:
Buna-N N/mm² 13.7 50
120 °C
(psi) (1,900)
25
Lap Shear Strength, ISO 4587:
Steel (grit blasted) N/mm² 20
(psi) (2,900) 0
Aluminum (etched) N/mm² 12.4 0 250 500 750 1000
(psi) (1,800) Exposure Time, hours
Zinc dichromate N/mm² 2.5
(psi) (360) Chemical/Solvent Resistance
ABS * N/mm² 7.5 Aged under conditions indicated and tested @ 22 °C
* (psi) (1,090) % of initial strength
PVC * N/mm² 10
Environment °C 100 h 500 h 1000 h
* (psi) (1,450)
Phenolic * N/mm² 12.6 Motor oil 40 115 85 85
* (psi) (1,820) Unleaded gasoline 22 85 90 95
Polycarbonate * N/mm² 9.6 Water 22 75 80 75
* (psi) (1,400)
Water/glycol 22 85 75 65
Nitrile * N/mm² 1.2
* (psi) (170) Ethanol 22 100 110 130
Neoprene * N/mm² 1.1 Isopropanol 22 115 100 120
* (psi) (160)
98% RH 40 80 65 65
Block Shear Strength, ISO 13445:
Polycarbonate N/mm² 11 Chemical/Solvent Resistance
(psi) (1,600) Aged under conditions indicated and tested @ 22°C.
ABS * N/mm² 23 Lap Shear Strength, ISO 4587, Polycarbonate
* (psi) (3,340)
PVC N/mm² 2.6
(psi) (380) % of initial strength
Phenolic * N/mm² 21.3 Environment °C 100 h 500 h 1000 h
* (psi) (3,090)
Air 22 110 120 115
* substrate failure 98% RH 40 110 120 105

GENERAL INFORMATION
TYPICAL ENVIRONMENTAL RESISTANCE This product is not recommended for use in pure oxygen
Cured for 1 week @ 22 °C and/or oxygen rich systems and should not be selected as
Lap Shear Strength, ISO 4587: a sealant for chlorine or other strong oxidizing materials.
Steel (grit blasted)
For safe handling information on this product, consult the
Material Safety Data Sheet (MSDS).
Hot Strength
Tested at temperature
140
Directions for use:
120
% Strength @ 22 °C

1. Bond areas should be clean and free from grease. Clean


100 all surfaces with a Loctite® cleaning solvent and allow to
80 dry.
2. To improve bonding on low energy plastic surfaces,
60
Loctite® Primer may be applied to the bond area. Avoid
40 applying excess Primer. Allow the Primer to dry.
3. LOCTITE® Activator may be used if necessary. Apply it to
20
one bond surface (do not apply activator to the primed
0 surface where Primer is also used). Allow the Activator to
-40 -20 0 20 40 60 80 100 120 140
Temperature, °C

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
TDS LOCTITE® 401™, February-2012

dry. Manufacturing Date Reference


4. Apply adhesive to one of the bond surfaces (do not apply This Technical Data Sheet is valid for LOCTITE® 401™
the adhesive to the activated surface). Do not use items manufactured from the dates below:
like tissue or a brush to spread the adhesive. Assemble
the parts within a few seconds. The parts should be Made in: First manufacturing date:
accurately located, as the short fixture time leaves little EU November 2011
opportunity for adjustment. China Pending
5. LOCTITE® Activator can be used to cure fillets of product India Pending
outside the bond area. Spray or drop the activator on the U.S.A. Pending
excess product. The manufacturing date can be determined from the batch
6. Bonds should be held fixed or clamped until adhesive has code on the pack. For assistance please contact your local
fixtured. Technical Service Center or Customer Service Representative.
7. Product should be allowed to develop full strength before
subjecting to any service loads (typically 24 to 72 hours
after assembly, depending on bond gap, materials and Note
ambient conditions). The data contained herein are furnished for information only
and are believed to be reliable. We cannot assume
responsibility for the results obtained by others over whose
Storage
methods we have no control. It is the user's responsibility to
Store product in the unopened container in a dry location.
determine suitability for the user's purpose of any production
Storage information may be indicated on the product container
methods mentioned herein and to adopt such precautions as
labeling.
may be advisable for the protection of property and of persons
Optimal Storage: 2 °C to 8 °C. Storage below 2 °C or
against any hazards that may be involved in the handling and
greater than 8 °C can adversely affect product properties.
use thereof. In light of the foregoing, Henkel Corporation
Material removed from containers may be contaminated during
specifically disclaims all warranties expressed or implied,
use. Do not return product to the original container. Henkel
including warranties of merchantability or fitness for a
Corporation cannot assume responsibility for product which
particular purpose, arising from sale or use of Henkel
has been contaminated or stored under conditions other than
Corporation’s products. Henkel Corporation specifically
those previously indicated. If additional information is required,
disclaims any liability for consequential or incidental
please contact your local Technical Service Center or
damages of any kind, including lost profits. The discussion
Customer Service Representative.
herein of various processes or compositions is not to be
interpreted as representation that they are free from
Loctite Material SpecificationLMS domination of patents owned by others or as a license under
LMS dated December-22, 2011. Test reports for each batch any Henkel Corporation patents that may cover such
are available for the indicated properties. LMS test reports processes or compositions. We recommend that each
include selected QC test parameters considered appropriate to prospective user test his proposed application before repetitive
specifications for customer use. Additionally, comprehensive use, using this data as a guide. This product may be covered
controls are in place to assure product quality and by one or more United States or foreign patents or patent
consistency. Special customer specification requirements may applications.
be coordinated through Henkel Quality.
Trademark usage
Conversions Except as otherwise noted, all trademarks in this document
(°C x 1.8) + 32 = °F
are trademarks of Henkel Corporation in the U.S. and
kV/mm x 25.4 = V/mil
mm / 25.4 = inches elsewhere. ® denotes a trademark registered in the U.S.
µm / 25.4 = mil Patent and Trademark Office.
N x 0.225 = lb
N/mm x 5.71 = lb/in
N/mm² x 145 = psi Reference 2.5
MPa x 145 = psi
N·m x 8.851 = lb·in
N·m x 0.738 = lb·ft
N·mm x 0.142 = oz·in
mPa·s = cP

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
Technical Data Sheet

LOCTITE® 406™
(TDS for new formulation of Loctite® 406™) February-2012

PRODUCT DESCRIPTION PVC <5


LOCTITE® 406™ provides the following product Polycarbonate 10 to 20
characteristics: Phenolic <5
Technology Cyanoacrylate
Chemical Type Ethyl cyanoacrylate
Appearance (uncured) Transparent, colorless to straw Cure Speed vs. Bond Gap
colored liquidLMS The rate of cure will depend on the bondline gap. Thin bond
Components One part - requires no mixing lines result in high cure speeds, increasing the bond gap will
Viscosity Low decrease the rate of cure.
Cure Humidity
Application Bonding
Key Substrates Plastics and Rubbers Cure Speed vs. Humidity
The rate of cure will depend on the ambient relative
This Technical Data Sheet is valid for LOCTITE® 406™ humidity. The best results are achieved when the relative
humidity in the working environment is 40% to 60% at 22°C.
manufactured from the dates outlined in the
Lower humidity leads to slower cure. Higher humidity
"Manufacturing Date Reference" section. accelerates it, but may impair the final strength of the bond.
LOCTITE® 406™ is designed for bonding of plastics and
elastomeric materials where very fast fixturing is required. Cure Speed vs. Activator
Where cure speed is unacceptably long due to large gaps,
Commercial Item Description A-A-3097:
applying activator to the surface will improve cure speed.
LOCTITE® 406™ has been qualified to Commercial Item However, this can reduce ultimate strength of the bond and
Description A-A-3097. Note: This is a regional approval. therefore testing is recommended to confirm effect.
Please contact your local Technical Service Center for more
information and clarification.

TYPICAL PROPERTIES OF UNCURED MATERIAL


Specific Gravity @ 25 °C 1.1
Viscosity, Cone & Plate, mPa·s (cP):
Temperature: 25 °C, Shear Rate: 3,000 s-1 12 to 22LMS
Viscosity, Brookfield - LVF, 25 °C, mPa·s (cP):
Spindle 1, speed 30 rpm 15 to 25
Flash Point - See MSDS

TYPICAL CURING PERFORMANCE


Under normal conditions, the atmospheric moisture initiates the
curing process. Although full functional strength is developed
in a relatively short time, curing continues for at least 24 hours
before full chemical/solvent resistance is developed.

Cure Speed vs. Substrate


The rate of cure will depend on the substrate used. The table
below shows the fixture time achieved on different materials
at 22 °C / 50 % relative humidity. This is defined as the time to
develop a shear strength of 0.1 N/mm².
Fixture Time, seconds:
Steel (degreased) 20 to 45
Aluminum (etched) <5
Neoprene <5
Rubber, nitrile <5
ABS <5
TDS LOCTITE® 406™, February-2012

TYPICAL PERFORMANCE OF CURED MATERIAL Heat Aging


Adhesive Properties Aged at temperature indicated and tested @ 22 °C
After 24 hours @ 22 °C
125
Lap Shear Strength, ISO 4587: 60 °C

% Initial Strength @ 22 °C
Steel (grit blasted) N/mm² 15.5
(psi) (2,250) 100
Aluminum (etched) N/mm² 12
(psi) (1,740) 75 80 °C
Zinc dichromate N/mm² 14
(psi) (2,030)
50
ABS * N/mm² 8.8 100 °C
* (psi) (1,280)
120 °C
PVC * N/mm² 8.7 25
* (psi) (1,260)
Polycarbonate * N/mm² 9.1 0
* (psi) (1,320) 0 250 500 750 1000
Phenolic * N/mm² 11.3 Exposure Time, hours
* (psi) (1,640)
Neoprene * N/mm² 1 Chemical/Solvent Resistance
* (psi) (150) Aged under conditions indicated and tested @ 22 °C.
Nitrile * N/mm² 1.2 % of initial strength
* (psi) ()
Environment °C 100 h 500 h 1000 h
Block Shear Strength, ISO 13445: Motor oil 40 100 85 70
Polycarbonate N/mm² 13.1 Gasoline 22 90 100 95
(psi) (1,900)
ABS * N/mm² 23.7 Water 22 55 70 70
* (psi) (3,440) Water/glycol 22 85 75 80
PVC N/mm² 1.8 Ethanol 22 105 105 100
(psi) (260)
Isopropanol 22 120 110 120
Phenolic * N/mm² 13.8
* (psi) (2,000) 98% RH 40 50 60 45

* substrate failure
Chemical/Solvent Resistance
Tensile Strength, ISO 6922: Aged under conditions indicated and tested @ 22°C.
Buna-N N/mm² 13 Lap Shear Strength, ISO 4587, Polycarbonate
(psi) (1,890)

After 10 seconds @ 22 °C % of initial strength


Tensile Strength, ISO 6922: Environment °C 100 h 500 h 1000 h
Buna-N N/mm² ≥6.9LMS Air 22 100 100 105
(psi) (≥1,000)
98% RH 40 85 90 85

TYPICAL ENVIRONMENTAL RESISTANCE GENERAL INFORMATION


Cured for 1 week @ 22 °C This product is not recommended for use in pure oxygen
Lap Shear Strength, ISO 4587: and/or oxygen rich systems and should not be selected as
Mild Steel (grit blasted) a sealant for chlorine or other strong oxidizing materials.

For safe handling information on this product, consult the


Hot Strength Material Safety Data Sheet (MSDS).
Tested at temperature
140

120
% Strength @ 22 °C

100

80

60

40

20

0
-40 -20 0 20 40 60 80 100 120 140
Temperature, °C

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
TDS LOCTITE® 406™, February-2012

Directions for use: Conversions


1. Bond areas should be clean and free from grease. Clean (°C x 1.8) + 32 = °F
kV/mm x 25.4 = V/mil
all surfaces with a Loctite® cleaning solvent and allow to
mm / 25.4 = inches
dry. µm / 25.4 = mil
2. To improve bonding on low energy plastic surfaces, N x 0.225 = lb
Loctite® Primer may be applied to the bond area. Avoid N/mm x 5.71 = lb/in
applying excess Primer. Allow the Primer to dry. N/mm² x 145 = psi
MPa x 145 = psi
3. LOCTITE® Activator may be used if necessary. Apply it to
N·m x 8.851 = lb·in
one bond surface (do not apply activator to the primed N·m x 0.738 = lb·ft
surface where Primer is also used). Allow the Activator to N·mm x 0.142 = oz·in
dry. mPa·s = cP
4. Apply adhesive to one of the bond surfaces (do not apply
the adhesive to the activated surface). Do not use items Manufacturing Date Reference
like tissue or a brush to spread the adhesive. Assemble This Technical Data Sheet is valid for LOCTITE® 406™
the parts within a few seconds. The parts should be
accurately located, as the short fixture time leaves little manufactured from the dates below:
opportunity for adjustment. Made in: First manufacturing date:
5. LOCTITE® Activator can be used to cure fillets of product EU November 2011
outside the bond area. Spray or drop the activator on the China Pending
excess product. India Pending
U.S.A. Pending
6. Bonds should be held fixed or clamped until adhesive has
fixtured. The manufacturing date can be determined from the batch
7. Product should be allowed to develop full strength before code on the pack. For assistance please contact your local
subjecting to any service loads (typically 24 to 72 hours Technical Service Center or Customer Service Representative.
after assembly, depending on bond gap, materials and
ambient conditions).
Note
Loctite Material Specification LMS The data contained herein are furnished for information only
LMS dated December-22, 2011. Test reports for each batch and are believed to be reliable. We cannot assume
are available for the indicated properties. LMS test reports responsibility for the results obtained by others over whose
include selected QC test parameters considered appropriate to methods we have no control. It is the user's responsibility to
specifications for customer use. Additionally, comprehensive determine suitability for the user's purpose of any production
controls are in place to assure product quality and methods mentioned herein and to adopt such precautions as
consistency. Special customer specification requirements may may be advisable for the protection of property and of persons
be coordinated through Henkel Quality. against any hazards that may be involved in the handling and
use thereof. In light of the foregoing, Henkel Corporation
specifically disclaims all warranties expressed or implied,
Storage including warranties of merchantability or fitness for a
Store product in the unopened container in a dry location. particular purpose, arising from sale or use of Henkel
Storage information may be indicated on the product container Corporation’s products. Henkel Corporation specifically
labeling. disclaims any liability for consequential or incidental
Optimal Storage: 2 °C to 8 °C. Storage below 2 °C or damages of any kind, including lost profits. The discussion
greater than 8 °C can adversely affect product properties. herein of various processes or compositions is not to be
Material removed from containers may be contaminated during interpreted as representation that they are free from
use. Do not return product to the original container. Henkel domination of patents owned by others or as a license under
Corporation cannot assume responsibility for product which any Henkel Corporation patents that may cover such
has been contaminated or stored under conditions other than processes or compositions. We recommend that each
those previously indicated. If additional information is required, prospective user test his proposed application before repetitive
please contact your local Technical Service Center or use, using this data as a guide. This product may be covered
Customer Service Representative. by one or more United States or foreign patents or patent
applications.

Trademark usage
Except as otherwise noted, all trademarks in this document
are trademarks of Henkel Corporation in the U.S. and
elsewhere. ® denotes a trademark registered in the U.S.
Patent and Trademark Office.

Reference 1.4

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
Technical Data Sheet

LOCTITE® 454™
(TDS for new formulation of Loctite® 454™) January-2012

PRODUCT DESCRIPTION Steel 30 to 60


LOCTITE® 454™ provides the following product Aluminum 2 to 10
characteristics: Neoprene 10 to 15
Rubber, nitrile <5
Technology Cyanoacrylate
ABS <5
Chemical Type Ethyl cyanoacrylate PVC 5 to 10
Appearance (uncured) Clear to slightly cloudy gelLMS Polycarbonate 10 to 15
Components One part - requires no mixing Phenolic <5
Viscosity High, thixotropic Wood (balsa) <5
Cure Humidity Wood (oak) 30 to 60
Application Bonding Wood (pine) 15 to 30
Key Substrates Metals, Plastics and Elastomers Chipboard 5 to 10
Fabric 10 to 20
Leather 5 to 15
This Technical Data Sheet is valid for LOCTITE® 454™ Paper 5 to 10
manufactured from the dates outlined in the
"Manufacturing Date Reference" section. Cure Speed vs. Bond Gap
The rate of cure will depend on the bondline gap. Thin bond
LOCTITE® 454™ is designed for the assembly of difficult- lines result in high cure speeds, increasing the bond gap will
to-bond materials which require uniform stress distribution and decrease the rate of cure.
strong tension and/or shear strength. The product provides
rapid bonding of a wide range of materials, including metals, Cure Speed vs. Humidity
The rate of cure will depend on the ambient relative
plastics and elastomers. The gel consistency prevents
humidity. The best results are achieved when the relative
adhesive flow even on vertical surfaces. LOCTITE® 454™ is humidity in the working environment is 40% to 60% at 22°C.
also suited for bonding porous materials such as wood, paper, Lower humidity leads to slower cure. Higher humidity
leather and fabric. accelerates it, but may impair the final strength of the bond.

NSF International Cure Speed vs. Activator


Registered to NSF Category P1 for use as a sealant where Where cure speed is unacceptably long due to large gaps,
there is no possibilty of food contact in and around food applying activator to the surface will improve cure speed.
processing areas. Note: This is a regional approval. Please However, this can reduce ultimate strength of the bond and
contact your local Technical Service Center for more therefore testing is recommended to confirm effect.
information and clarification.

TYPICAL PROPERTIES OF UNCURED MATERIAL


Specific Gravity @ 25 °C 1.1
Flash Point - See MSDS
Casson Viscosity, 25 °C, mPa·s (cP):
Cone and Plate Rheometer 150 to 450LMS
Viscosity, Brookfield - RVT, 25 °C, mPa·s (cP):
Spindle TC, speed 2.5 rpm, Helipath *100,000 to 300,000LMS
Spindle TC, speed 20 rpm, Helipath *18,000 to 40,000LMS
* Applies to material made in N. America
TYPICAL CURING PERFORMANCE
Under normal conditions, the atmospheric moisture initiates the
curing process. Although full functional strength is developed
in a relatively short time, curing continues for at least 24 hours
before full chemical/solvent resistance is developed.

Cure Speed vs. Substrate


The rate of cure will depend on the substrate used. The table
below shows the fixture time achieved on different materials
at 22 °C / 50 % relative humidity. This is defined as the time to
develop a shear strength of 0.1 N/mm².
Fixture Time, seconds:
TDS LOCTITE® 454™, January-2012

TYPICAL PERFORMANCE OF CURED MATERIAL Heat Aging


Adhesive Properties Aged at temperature indicated and tested @ 22 °C
125
Cured for 30 seconds @ 22 °C

% Initial Strength @ 22 °C
Tensile Strength, ISO 6922:
Buna-N N/mm² ≥6.0LMS 100 60 °C
(psi) (≥870)
80 °C
75

Cured for 72 hours @ 22 °C


Tensile Strength, ISO 6922: 50 100 °C
Buna-N N/mm² 15.1
(psi) (2,190) 25 120 °C
Lap Shear Strength, ISO 4587:
Steel (grit blasted) N/mm² 20.9 0
0 250 500 1000
(psi) (3,030) Exposure Time, hours
Aluminum (etched) N/mm² 17.1
(psi) (2,480)
Zinc dichromate N/mm² 11.5 Chemical/Solvent Resistance
(psi) (1,670) Aged under conditions indicated and tested @ 22 °C.
ABS * N/mm² 8.3 % of initial strength
* (psi) (1,200)
Environment °C 100 h 500 h 1000 h
PVC * N/mm² 7.1
* (psi) (1,030) Motor oil 40 105 85 80
Phenolic * N/mm² 12.3 Unleaded gasoline 22 95 120 125
* (psi) (1,780) Water 22 75 70 75
Polycarbonate N/mm² 7.7
(psi) (1,120) Water/glycol 22 90 85 85
Nitrile * N/mm² 1.3 Ethanol 22 120 125 120
* (psi) (190) Isopropanol 22 100 130 135
Neoprene * N/mm² 1.1 98% RH 40 70 55 55
* (psi) (160)

Block Shear Strength, ISO 13445: Chemical/Solvent Resistance


Polycarbonate N/mm² 9.6 Aged under conditions indicated and tested @ 22°C.
(psi) (1,390) Lap Shear Strength, ISO 4587, Polycarbonate
ABS N/mm² 23.3
(psi) (3,380)
PVC N/mm² 3.3 % of initial strength
(psi) (480) Environment °C 100 h 500 h 1000 h
Phenolic * N/mm² 6.7 Air 22 105 105 105
* (psi) (970)
98% RH 40 105 105 105
* substrate failure
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
TYPICAL ENVIRONMENTAL RESISTANCE and/or oxygen rich systems and should not be selected as
Cured for 1 week @ 22 °C a sealant for chlorine or other strong oxidizing materials.
Lap Shear Strength, ISO 4587: For safe handling information on this product, consult the
Steel (grit blasted) Material Safety Data Sheet (MSDS).

Hot Strength
Tested at temperature Directions for use:
140 1. Bond areas should be clean and free from grease. Clean
120
all surfaces with a Loctite® cleaning solvent and allow to
% Strength @ 22 °C

dry.
100 2. To improve bonding on low energy plastic surfaces,
80 Loctite® Primer may be applied to the bond area. Avoid
applying excess Primer. Allow the Primer to dry.
60
3. LOCTITE® Activator may be used if necessary. Apply it to
40 one bond surface (do not apply activator to the primed
20 surface where Primer is also used). Allow the Activator to
dry.
0
-40 -20 0 20 40 60 80 100 120 140
Temperature, °C

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
TDS LOCTITE® 454™, January-2012

4. Apply adhesive to one of the bond surfaces (do not apply Manufacturing Date Reference
the adhesive to the activated surface). Do not use items This Technical Data Sheet is valid for LOCTITE® 454™
like tissue or a brush to spread the adhesive. Assemble
manufactured from the dates below:
the parts within a few seconds. The parts should be
accurately located, as the short fixture time leaves little Made in: First manufacturing date:
opportunity for adjustment. EU December 2011
5. LOCTITE® Activator can be used to cure fillets of product China Pending
outside the bond area. Spray or drop the activator on the India Pending
excess product. U.S.A. Pending
6. Bonds should be held fixed or clamped until adhesive has The manufacturing date can be determined from the batch
fixtured. code on the pack. For assistance please contact your local
7. Product should be allowed to develop full strength before Technical Service Center or Customer Service Representative.
subjecting to any service loads (typically 24 to 72 hours
after assembly, depending on bond gap, materials and
ambient conditions). Note
The data contained herein are furnished for information only
Loctite Material SpecificationLMS and are believed to be reliable. We cannot assume
LMS dated December-22, 2011. Test reports for each batch responsibility for the results obtained by others over whose
are available for the indicated properties. LMS test reports methods we have no control. It is the user's responsibility to
include selected QC test parameters considered appropriate to determine suitability for the user's purpose of any production
specifications for customer use. Additionally, comprehensive methods mentioned herein and to adopt such precautions as
controls are in place to assure product quality and may be advisable for the protection of property and of persons
consistency. Special customer specification requirements may against any hazards that may be involved in the handling and
be coordinated through Henkel Quality. use thereof. In light of the foregoing, Henkel Corporation
specifically disclaims all warranties expressed or implied,
including warranties of merchantability or fitness for a
Storage particular purpose, arising from sale or use of Henkel
Store product in the unopened container in a dry location. Corporation’s products. Henkel Corporation specifically
Storage information may be indicated on the product container disclaims any liability for consequential or incidental
labeling. damages of any kind, including lost profits. The discussion
Optimal Storage: 2 °C to 8 °C. Storage below 2 °C or herein of various processes or compositions is not to be
greater than 8 °C can adversely affect product properties. interpreted as representation that they are free from
Material removed from containers may be contaminated during domination of patents owned by others or as a license under
use. Do not return product to the original container. Henkel any Henkel Corporation patents that may cover such
Corporation cannot assume responsibility for product which processes or compositions. We recommend that each
has been contaminated or stored under conditions other than prospective user test his proposed application before repetitive
those previously indicated. If additional information is required, use, using this data as a guide. This product may be covered
please contact your local Technical Service Center or by one or more United States or foreign patents or patent
Customer Service Representative. applications.

Conversions Trademark usage


(°C x 1.8) + 32 = °F
Except as otherwise noted, all trademarks in this document
kV/mm x 25.4 = V/mil
mm / 25.4 = inches are trademarks of Henkel Corporation in the U.S. and
µm / 25.4 = mil elsewhere. ® denotes a trademark registered in the U.S.
N x 0.225 = lb Patent and Trademark Office.
N/mm x 5.71 = lb/in
N/mm² x 145 = psi
MPa x 145 = psi Reference 2.6
N·m x 8.851 = lb·in
N·m x 0.738 = lb·ft
N·mm x 0.142 = oz·in
mPa·s = cP

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
Technical Data Sheet

LOCTITE® 495
(TDS for new formulation of Loctite® 495™) February-2012

PRODUCT DESCRIPTION Mild Steel (degreased) 5 to 10


LOCTITE® 495 provides the following product characteristics: Aluminum (degreased) <5
Technology Cyanoacrylate Neoprene <5
Rubber, nitrile <5
Chemical Type Ethyl cyanoacrylate
ABS <5
Appearance (uncured) Transparent, colorless to straw
PVC <5
colored liquidLMS
Polycarbonate 10 to 15
Components One part - requires no mixing Phenolic <5
Viscosity Low
Cure Humidity
Application Bonding
Key Substrates Plastics, Rubbers and Metals

Cure Speed vs. Bond Gap


This Technical Data Sheet is valid for LOCTITE® 495 The rate of cure will depend on the bondline gap. Thin bond
manufactured from the dates outlined in the lines result in high cure speeds, increasing the bond gap will
"Manufacturing Date Reference" section. decrease the rate of cure.

Cure Speed vs. Humidity


LOCTITE® 495 is a general purpose cyanoacrylate instant The rate of cure will depend on the ambient relative
adhesive. humidity. The best results are achieved when the relative
humidity in the working environment is 40% to 60% at 22°C.
Lower humidity leads to slower cure. Higher humidity
Commercial Item Description A-A-3097: accelerates it, but may impair the final strength of the bond.
LOCTITE® 495 has been qualified to Commercial Item
Description A-A-3097. Note: This is a regional approval. Cure Speed vs. Activator
Please contact your local Technical Service Center for more Where cure speed is unacceptably long due to large gaps,
information and clarification. applying activator to the surface will improve cure speed.
However, this can reduce ultimate strength of the bond and
therefore testing is recommended to confirm effect.

TYPICAL PROPERTIES OF UNCURED MATERIAL


TYPICAL PERFORMANCE OF CURED MATERIAL
Specific Gravity @ 25 °C 1.1
Adhesive Properties

Viscosity, Cone & Plate, mPa·s (cP): After 24 hours @ 22 °C


Temperature: 25 °C, Shear Rate: 3,000 s-1 20 to 45LMS Lap Shear Strength, ISO 4587:
Viscosity, Brookfield - LVF, 25 °C, mPa·s (cP): Steel (grit blasted) N/mm² 14.2
Spindle 1, speed 30 rpm 20 to 60 (psi) (2,060)
Aluminum (grit blasted) N/mm² 10.8
(psi) (1,570)
Zinc dichromate N/mm² 5.9
Flash Point - See MSDS (psi) (860)
ABS * N/mm² 7.9
* (psi) (1,150)
PVC * N/mm² 8.7
TYPICAL CURING PERFORMANCE * (psi) (1,260)
Under normal conditions, the atmospheric moisture initiates the Polycarbonate * N/mm² 8
curing process. Although full functional strength is developed * (psi) (1,160)
in a relatively short time, curing continues for at least 24 hours Phenolic N/mm² 9.9
before full chemical/solvent resistance is developed. (psi) (1,440)
Neoprene * N/mm² 1
* (psi) (145)
Cure Speed vs. Substrate Nitrile * N/mm² 1.3
The rate of cure will depend on the substrate used. The table * (psi) (190)
below shows the fixture time achieved on different materials
at 22 °C / 50 % relative humidity. This is defined as the time to
develop a shear strength of 0.1 N/mm².
Fixture Time, seconds:
TDS LOCTITE® 495, February-2012

Block Shear Strength, ISO 13445:


Polycarbonate N/mm² 8.4 Chemical/Solvent Resistance
(psi) (1,220) Aged under conditions indicated and tested @ 22 °C.
ABS * N/mm² 22.3 % of initial strength
* (psi) (3,230)
Environment °C 100 h 500 h 1000 h
PVC N/mm² 2.9
(psi) (420) Motor oil (MIL-L-46152) 40 120 130 95
Phenolic * N/mm² 16.0 Gasoline 22 100 120 105
* (psi) (2,320)
Isopropanol 22 110 110 120
* substrate failure
Ethanol 22 110 115 120
Tensile Strength, ISO 6922: 98% RH 40 80 65 55
Buna-N N/mm² 13.7 Water 22 85 75 70
(psi) (1,990)
Water/glycol 50/50 22 95 85 80

"T" Peel Strength, ISO 11339:


Chemical/Solvent Resistance
Steel (degreased) N/mm <0.5
Aged under conditions indicated and tested @ 22°C.
(lb/in) (<2.8)
Lap Shear Strength, ISO 4587, Polycarbonate
After 10 seconds @ 22 °C
Tensile Strength, ISO 6922:
Buna-N N/mm² ≥6.0LMS % of initial strength
(psi) (≥870) Environment °C 100 h 500 h 1000 h
Air 22 105 110 110
98% RH 40 120 125 110
TYPICAL ENVIRONMENTAL RESISTANCE
After 1 week @ 22 °C
Lap Shear Strength, ISO 4587:
Mild Steel (grit blasted) GENERAL INFORMATION
This product is not recommended for use in pure oxygen
Hot Strength and/or oxygen rich systems and should not be selected as
Tested at temperature a sealant for chlorine or other strong oxidizing materials.
150 For safe handling information on this product, consult the
Material Safety Data Sheet (MSDS).
% Strength @ 22 °C

125

100 Directions for use:


1. Bond areas should be clean and free from grease. Clean
75 all surfaces with a Loctite® cleaning solvent and allow to
dry.
50
2. To improve bonding on low energy plastic surfaces,
25 Loctite® Primer may be applied to the bond area. Avoid
applying excess Primer. Allow the Primer to dry.
0 3. LOCTITE® Activator may be used if necessary. Apply it to
-40 -20 0 20 40 60 80 100 120 140
Temperature, °C one bond surface (do not apply activator to the primed
surface where Primer is also used). Allow the Activator to
Heat Aging dry.
Aged at temperature indicated and tested @ 22 °C 4. Apply adhesive to one of the bond surfaces (do not apply
Block shear Strength, ISO 13445, the adhesive to the activated surface). Do not use items
Polycarbonate like tissue or a brush to spread the adhesive. Assemble
the parts within a few seconds. The parts should be
accurately located, as the short fixture time leaves little
125
60 °C opportunity for adjustment.
% Initial Strength @ 22 °C

80 °C 5. LOCTITE® Activator can be used to cure fillets of product


100
outside the bond area. Spray or drop the activator on the
excess product.
75 100 °C 6. Bonds should be held fixed or clamped until adhesive has
fixtured.
50 7. Product should be allowed to develop full strength before
subjecting to any service loads (typically 24 to 72 hours
120 °C
25 after assembly, depending on bond gap, materials and
ambient conditions).
0
0 250 500 750 1000
Exposure Time, hours

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial
TDS LOCTITE® 495, February-2012

Loctite Material SpecificationLMS Note


LMS dated January-03, 2012. Test reports for each batch are The data contained herein are furnished for information only
available for the indicated properties. LMS test reports include and are believed to be reliable. We cannot assume
selected QC test parameters considered appropriate to responsibility for the results obtained by others over whose
specifications for customer use. Additionally, comprehensive methods we have no control. It is the user's responsibility to
controls are in place to assure product quality and determine suitability for the user's purpose of any production
consistency. Special customer specification requirements may methods mentioned herein and to adopt such precautions as
be coordinated through Henkel Quality. may be advisable for the protection of property and of persons
against any hazards that may be involved in the handling and
Storage use thereof. In light of the foregoing, Henkel Corporation
Store product in the unopened container in a dry location. specifically disclaims all warranties expressed or implied,
Storage information may be indicated on the product container including warranties of merchantability or fitness for a
labeling. particular purpose, arising from sale or use of Henkel
Optimal Storage: 2 °C to 8 °C. Storage below 2 °C or Corporation’s products. Henkel Corporation specifically
greater than 8 °C can adversely affect product properties. disclaims any liability for consequential or incidental
Material removed from containers may be contaminated during damages of any kind, including lost profits. The discussion
use. Do not return product to the original container. Henkel herein of various processes or compositions is not to be
Corporation cannot assume responsibility for product which interpreted as representation that they are free from
has been contaminated or stored under conditions other than domination of patents owned by others or as a license under
those previously indicated. If additional information is required, any Henkel Corporation patents that may cover such
please contact your local Technical Service Center or processes or compositions. We recommend that each
Customer Service Representative. prospective user test his proposed application before repetitive
use, using this data as a guide. This product may be covered
Conversions
by one or more United States or foreign patents or patent
(°C x 1.8) + 32 = °F
applications.
kV/mm x 25.4 = V/mil
mm / 25.4 = inches Trademark usage
µm / 25.4 = mil Except as otherwise noted, all trademarks in this document
N x 0.225 = lb
N/mm x 5.71 = lb/in are trademarks of Henkel Corporation in the U.S. and
N/mm² x 145 = psi elsewhere. ® denotes a trademark registered in the U.S.
MPa x 145 = psi Patent and Trademark Office.
N·m x 8.851 = lb·in
N·m x 0.738 = lb·ft
N·mm x 0.142 = oz·in Reference 1.2
mPa·s = cP
Manufacturing Date Reference
This Technical Data Sheet is valid for LOCTITE® 495
manufactured from the dates below:
Made in: First manufacturing date:
EU Pending
China Pending
India Pending
U.S.A. Pending

The manufacturing date can be determined from the batch


code on the pack. For assistance please contact your local
Technical Service Center or Customer Service Representative.

Henkel Americas Henkel Europe Henkel Asia Pacific


+860.571.5100 +49.89.320800.1800 +86.21.2891.8863
For the most direct access to local sales and technical support visit: www.henkel.com/industrial

Das könnte Ihnen auch gefallen