Content
1. Summarize..........................................................................................................................................3
1.1 System introduction................................................................................................................. 3
1.2 System Features....................................................................................................................... 3
2. Alarm System Operation.................................................................................................................... 4
2.1 Arming......................................................................................................................................4
2.2 Stay Arming ............................................................................................................................4
2.3 Disarming ............................................................................................................................... 4
2.4 Emergency Alarm.....................................................................................................................4
2.5 Alarm System Setup.................................................................................................................5
2.6 Summary of Indicators.............................................................................................................6
3. System Setting....................................................................................................................................7
3.1 Alarm Panel Initial Setup......................................................................................................... 7
3.2 Pre-record Voice Message........................................................................................................7
3.3 Add Remote Control:............................................................................................................... 7
3.4 Delete remote control:..............................................................................................................7
3.5 Add detector............................................................................................................................. 7
3.6 Delete detector..........................................................................................................................8
3.7 Add Wireless Strobe Siren, smart sockets and relay output.................................................... 8
3.7.1 Add wireless strobe siren.............................................................................................. 8
3.7.2 Add smart socket...........................................................................................................8
3.7.2 Add wireless relay output..............................................................................................8
3.8 Setting commands.................................................................................................................... 9
3.9. Query.....................................................................................................................................15
4. Remote Control of Panel..................................................................................................................18
4.1After receive the alarm system alert....................................................................................... 18
4.2 Remote Dialing In Operation:................................................................................................19
5. Types of alarm zone......................................................................................................................... 19
6. Fitting parameters:............................................................................................................................20
7. Installation of sensors.......................................................................................................................21
7.1 Guideline for Installing Door or Window Sensor..................................................................21
7.2 Guideline for Installing PIR Motion Sensor..........................................................................21
8. Troubleshooting................................................................................................................................22
3
1. Summarize
This alarm system with a digital clock screen, support 120 defense zones, for home/commercial
use. Apply a micro computer processing technic, built-in high quality real-human voice prompt chip
and accurately clock chip. Intelligent long distance home appliance control, stable and high
performance.
Can add: remote control, PIR sensor, door sensor, gas detector, smoke detector, emergency button
and etc.
Widely applied in factory, warehouse, account office, school, hospital, hotel, shop, residential area,
villa, chamber, farm, scenic region and etc., keep your property safety.
2.1 Arming
All detectors are activated, when the some events ( burglar, fire, gas leak, etc ) happened and
detected, , alarm system alarm right away.
1.By remote control: press the [ ] button once. 2.By panel keyboard: press the the [ ] button
once. screen shows appearing “BF”for one second.
Partial arming when people at home, only some of the selected sensors which in the outer range are
activated.
1.By remote control: press the [S] button once. 2.By panel keyboard: press the the [ ] button twice.
the screen appearing “LB”for one second.
2.3 Disarming
All sensors are deactivated and will not be respond to any events.(except the emergency zone).
1.By remote control: press the [ ] button once. 2.By panel keyboard: press the the [ ] button
Press the emergency button on the remote control or press the keyboard [ ] button any time, the
Remark:
If keyboard password is enabled, you need to enter password before other operations, the initial
password is 1234.
Alarm panel should be installed at a central location with best transmission to all the wireless
sensors and accessories. Keep the panel well away from large metal objects or household appliances
with high-frequency interference, and avoid barriers such as concrete walls with metal frame inside
and fire doors.
6
Stay arming icon Long lighting and display “LB” Panel is in Stay Arming status
for one second.
Disarming icon Long lighting and display “CF” Panel is in Disarming status
for one second.
Four digitals appearing tube Light off Panel is in power saving mode,
will light off after no operation
for 1 minutes
3. System Setting
Connect telephone line, extension line, siren and other cables if any according to above instruction,
power up the alarm panel. The system voice prompt "Welcome to use alarm system"and display
time on the screen, then turn the battery switch at the [ON] position for continuous charging.
Alarm panel will play a pre-recorded voice message after receiving the alarm call. To record
customized message:
Press # Key to enter the configuration mode→ press 19#→speak your message, the panel auto
record. Massage should be simple like: House be intruded, please help.
System can record 10 Seconds and then automatically exit; or press any key to Exit.
Press *, then # exit setup status.
Press # to enter the setting status→08+(001~120)+# to delete target zones remote control.
(08+***+# means delete remotes in all zones )
Example: #08001# means delete the 1st zone remote control.
Press # +10+Zone Number (001~120)+# to delete the detector (#+10+***+# means delete all
detectors)
Example: #10001# means delete the 001zones’s detector. Upon completion press # to exit the
configuration mode, press * and then # exit the configuration mode.
3.7 Add Wireless Strobe Siren, smart sockets and relay output
Press the strobe siren’s “set” key once to enter start code learning, then press the panel’s “disarm”
key, strobe siren beep once means learn success. (Strobe siren details, refer to strobe siren user
guide)
Press # +9+【9】+【0】# →Long press wireless relay output (intelligent socket) “set” key to enter
learning status→press # on panel→input 990#, smart socket light flash once means configure
9
success. (Please refer to smart socket user guide for details.) Press # to exit.
(Both 1-8 groups of smart socket and 9th group of reply output are intelligent socket. The 9th group
reply output will automatically switch ON/OFF when alarm. In the disarming status, will auto
switch off. 1-8 group of smart socket will not.)
3.8.2 Example: If you want to delete the first groups of phone number,
Delete alert calling phone Method 1: By keyboard
number Press # → then input 31# ,
Syntax: press * then # to exit.
Method 2: By phone
【3】+【1-9】+【#】
Call the panel→Input password→Input # →then input 31#.
3.8.4 the panel can be set to delay arming after 0-99 seconds. The system
Delay arming setting default is 00 seconds.
Example: user need to set delay arming after 60 Seconds.
Method 1: by keyboard
Syntax: Input #5160#, press * then # to exit.
【51】+ seconds【00-99】+【#】 Method 2: By call
press #5160# after input password
3.8.5 Set the time of delay upon alarm, it can be set to 0-99 seconds, the system
Delay alarming setting default is 00 seconds.
Syntax: Example: the user needs to set the delay alarming after 60 Seconds.
Method 1: keyboard
【52】+ seconds【00-99】+【#】
Press #5260#, press * then # to exit.
Method 2: call
press #5260# after input password
3.8.6 The siren time can be set from 0-20 minutes, Defaults to 1 minute。
Siren time setting Example:siren time is 5 minutes。
Syntax: Method 1: keyboard
Press # 5305#, press * then # to exit.
【53】+ minutes【00-20】+【#】
Method 2: call
press #5305# after input password.
3.8.7 The remote control and panel was defaults to control all the zones.
Define the control range of each Note:001 for #1 remote control, *** for panel
remote control/ Keyboard example: #01 remote control to control the defence zones #0-20.
Syntax: Method 1:
【54】+ remote control【001~120】 Press # to enter the setting status,then input 54001000020#
+ begin zone【001~120】 Example:panel to control the defence zone #00-50.
+ end zone【001~120】+【#】 Method 1:
Press key # to enter setting status, then press 54***000050#,
press * then # to exit.
Method 2:
Enter the telephone remote setting status,then press 54001000020# ,
then press 54***000050#.
3.8.8 1 to open the voice prompt,0 to close it,defaults to open。
voice prompt for panel and example:no voice prompt when arming/disarming by #01 remote control
remote control Method 1:keyboard
Press # 550010#, press * then # to exit.
Example:no voice prompt when arming/disarming by panel.
Method 1:keyboard
press # 55***0#, press * then press # to exit.
Syntax: Method 2:call
No voice prompt for remote control: input #550010# after input password.
【55】+ remote control【001~120】
No voice prompt for keyboard: input #55***0# after input password.
+【0/1】+【#】
11
3.8.12 Example:alarm clock at 07:30 and end at 07:32, available from Monday to
Add alarm clock Friday.
Syntax: Method 1:Keyboard
Press #57050730073212345#.
【57】+ groups【05~06】+ begin
Example:Secondly clock alarm at 13:40 and end at 13:45,
time【AAAA】+ end time【BBBB】
Available from Monday to Friday.
+ Day【1-7】+【#】
Method 1:Keyboard
press #57061340134512345#, Press * then # to exit
Method 2:Call
1, then input #57050730073212345#, after password input.
2, Input #57061340134512345# after password input.
Method 2:Call
Input #131# after password input
3.8.25 Adjust volume of extra 99 levels adjusted of siren volume, 00 for no voice, 99 for max volume.
siren Defaults as max.
Syntax: Example: adjust the volume of siren to 50 level:
Method 1:Keyboard
【14】+【00-99】+【#】
press # 1450#
Method 2:Call
input #1450# after call connected
3.8.26 Remote control can’t disarm of panel in the arming status,but keypad
Anti-crack function can. 0 means turn off the function, 1 means turn on. The default value is
off.
Syntax:
Example: turn on the anti-crack function:
【15】+【0/1】+【#】 Method 1:Keyboard
press # 151#
Method 2:Call
input #151#
3.8.27 Co-channel interference Co-channel interference prompt means illegal remote control or
prompts transmitter keep press 15 seconds, panel has tP display and siren will
sound 5 seconds.
Syntax:
Example: turn on co-channel interference prompt:
【16】+【0/1】+【#】
Method 1:Keyboard
press # 161#
Method 2:Call
input #161#
3.8.28 Can’t operate the panel until input the password. Defaults password as
Keypad lock 1234. (super password 2099 can open the keypad lock whatever and
Syntax: whenever.)
Example: turn on keypad lock.
【17】+【0/1】+【#】
Method 1:keyboard
press # 171#
Method 2:Call
input #171#
3.8.29 The defaults rings number of telephone calling is 8 times. 00 for closed
Number of rings of telephone telephone remote control function, 08 is the max ring number.
Example: adjust the ring number to 6 times:
Syntax:
Method 1:Keyboard
【18】+【00-99】+【#】
press #1800#
Method 2:Call
then input #1800#
3.8.30 Panel with 9 Smart sockets, only 9th socket auto-works when alarming,
Smart socket 0/1 for on/off.
15
3.8.32 Restoring factory setting will delete all the record and return to factory
Total System Reset defaults, as well as remote control and detectors.
Syntax: (should be used with caution)
Method 1:
【989801】+【#】
press # to enter the setting status, then input 989801#, keep pressing # until
panel complete rebooting.
Not support telephone remote setting.
3.9. Query
Query of alert phone number To query the alarm panel currently saved to the first set to the Ninth
group voice alarm phone number.
Syntax: 3 +【1-9】+【#】 query key→input 31#, the panel display 13812345678 means alarm panel's
first group of alert phone number is 13812345678.
Password Query Used to query the current password of the alarm panel .
Press query key → press 50#, the alarm panel display password→Press # to
Syntax: 50 +【#】
clear the screen, press * then press # to exit
Query the time for delay arm Query delay time for arm (00-99) Seconds
Press query key→then press 51#, the alarm panel display delay arm time
Syntax:: 51 +【#】
Query delay time for alarming To query the alarm delay time (00-99) Seconds
Press query key →press 52#, the alarm panel display delay alarm time
Syntax:: 52+【#】
Query siren sounding time for To query the siren sounding time (00-20) minutes when the alarming.
Press query key→press press 53#, the alarm panel display siren souding
alarming
time
Syntax: 53+【#】
16
Query remote control or keyboard For query of specific remote control and keyboard assignments to zone
assignments to zone 001-120
Syntax: 54+【001-120】+【#】 Press query key→press 54001#, the alarm panel display 001-120, means
remote control 1 is controlling zones 001-120, press # clear screen, press
54002# for query remote control 2 and so on.
Query remote control or keyboard For query the setting of remote control 001-120 for the audible
audible confirmation confirmation to command.
Inquire the remote control siren Press query key→press 55001#, the alarm panel display ON means panel
sound will be sound when keyboard or remote send command
Syntax:55+【001-120】+【#】
Inquiry the system date and time Used to inquiry the system year, date and time
Example:press query key→press 56 # to inquiry the system time, on the
Syntax:56+【#】
screen displays 2014, after a tick shows 0308,one tick again then shows
1630,one tick again shows 6, which means the host current time is 16:30 on
Saturday, August 8, 2014.
Query the scheduled time for arm Used to query first to fourth set of scheduled time for arm and disarm.,
and disarm and 2 group doorbell setting time.
Syntax: 57+【01-06】+【#】 Press query key→press press 5701# to query the first of scheduled arm and
disarm, the alarm panel display "2200",after "Beep" once the panel display"
0700" and then display "12345" after Beep" once .
Means: the first group scheduled time to arm at 22 :00 pm and disarm at
07 : 00 am, this is valid for Monday, Tuesday, Wednesday, Thursday and
Friday of each week.
Query the zone number with For query the zone number be control by scheduled arm and disarm
scheduled arm and disarm Press query key→Press 5801# ,LCD display 000-120,means first scheduled
Syntax:58+【01-04】+【#】 arm and disarm tome will control 000-120zones,if display 10-20,means
control 010-020 zones
Query type wireless defense zone For query the zone types of wireless zones 001-120
and Siren sound or not Press query key→press 600001# to query the 1 zones defense zone.
1-8 represents one of the 8 zone type:
Syntax: 60+【001-120】+【#】 NORMAL 2.STAY ARM 3.INTELLIGENT 4.EMERGENCY 5.CLOSED
6.CHIME 7.WELCOME 8.HELP SENIOR
"OFF" means siren of panel produce no sound upon alarming while "ON" is
sounded.
Query remote operation on/off To query if the remote operation is allowed, it should show either ON or
OFF.
Syntax: 62+【#】
Query phone number for specific To query the phone number assigned to zone 001-120 for alert.
zone Example: Press alarm panel query key of your keyboard, then press 63001#
Syntax:63+【001-120】+【#】 for zone 1, the alarm panel display 123456 means these 6 group of phone
numbers are assigned to 01 zone.
Query the prompt voice volume To query the prompt voice volume,1 is the minimum,7 is maximum
17
Syntax:79+【#】
Query clock display energy saving Used to inquiry the host digital pipe display energy saving mode
mode ON/OFF ON/OFF
Syntax:84+【#】 ON means open, OFF means closed.
Query the build-in siren volume To query the build-in siren volume,0 is the mute,7 is maximum
Syntax:87+【#】
Query breathing light On/Off To query breathing light is ON or OFF
Syntax:88+【#】
Query for the setting of alarm For query whether the alarm will play audible confirmation upon
audible confirmation receipt of commands. It shows either ON or OFF.
Syntax:11+【#】
Query sound volume of wired siren Query for the volume level of wired siren, it shows between 00-99 ,00 is
the minimum,99 is maximum
Syntax:14+【#】
Query for the setting of enforced To query whether enforcing the disarm from keyboard upon alarming.
keyboard disarm It shows either ON or OFF.
Syntax: 15+【#】
Query of the setting of interference To query whether interference alert is set, it shows either ON or OFF.
alert
Syntax:16+【#】
Query keyboard password To query if the password protection feature is enabled, it shows either
protection ON or OFF.
Syntax::17+【#】
Query the host arming and Used to query the host arm and disarm records,the system will save the
disarming records recent 72 article arming and disarming recordings.
Syntax:9901+【#】 Press the "Query "key→press9901#→then press 8 to check the last record,
press 0 to check the next one.
The first show for the arm and disarm record 01 means first record
1st tick shows for date, for example: 0801 means August 1,
2nd a tick shows for time, for example: 1210 means 12 :10
3rd a tick shows for YC means remote, JP means keyboard, DS means
timing
4th YK means remote control, CF means disarm, BF means arm.
LSBF means at home arming
01 means No.1 remote, 120 means No.120 remote.
Note: if display DS, then show 01,02,03,04 which means the first group to
the fourth group timing.
Query the host alarm record Used to query the host alarm records,the system will save the recent 102
18
After Panel alerts, it will automatically dial the preset 1-6 group telephone number for three times
until connected.(the panel will dial the 7-8 group telephone number when the trigger detector in the
HELP SENIOR Defense Zone). When the user picks up the phone, a piece of pre-recorded voice
message will be played back immediately and let the receiver noted about the event. Upon receiving
the call, it can also control the alarm panel remotely via the phone (according to the command
below). User will not be asked for password upon connected and alarm will automatically hang up
call within receiving any instruction within 20 seconds.
[1]: arming [2]: disarming
[3]: monitoring open [4]: monitoring closed
[5]: Speak open [6]: Speak closed
[7]: siren on [8]: siren off
[9]+[1-9]+[0/1]+# to control the intelligent socket Switch On/Off.([0/1]--0 means OFF,1 means
ON)
[*] key: exit and hang up, the system will not dial the next group number. If not press"*" or "2",
the system will continue to dial the next group number.
Remark: monitoring time for 20 seconds,if need to continue then press[3]or[5] key within 20
seconds
19
Dial into the alarm panel using telephone or cellular phone can carry out some operations remotely.
Upon the panel pick up your call and connected, follow instruction played to input password,
(default password is 1234), press the corresponding number on phone keypad for operation. Alarm
will automatically hang up call after invalid password failed for three times in succession.
welcome voice message will be played. While in arming status, system alarms.
HELP SENIOR Defense Zone: This type of zone is for elderly safety, no matter in what status, the
panel will alarm once sensor with this zone type is triggered. System automatically dial 7,8,9 groups
help senior number, once the phone picked up, it remind with voice of “someone need help”
System default zone types are:
6. Fitting parameters:
Input voltage: USB 5V
Standby currents:<25mA
Alarm current: <450mA
Wireless frequency : 433.92 MHz
Back-up battery:lithium battery 3.7V 500mAh
Alarm loudness:110dB ( External siren )
90dB ( Internal siren )
Detailed parameters: The alarm should be compatible with PT2262, PT2240 and EV1527. Using
PT2262 encoding, the resistance is recommended 1.5M-4.7M; using with EV1527 encoding, the
resistance is recommended 150K-470K.
21
7. Installation of sensors
A B
The surface for door sensor installation should be clean so door sensor can be attached to the door
and frame firmly with double faced adhesive.
1.Each kit door sensor include sensor (A as in diagram) and magnet (B as in diagram). B must be
the right hand side. (A and B, one on fixed door frame, another one on movable door.)
2. A and B must be in line,The distance between A and B not exceeding 1 cm.
3.Upon installed, door sensor should be tested by open the door and check if the indicator on door
sensor flashes for 1 second.
4.The indicator light lit for one second, means alarm. In case the door sensor is running out of
battery, the indicator should be kept lit as a low-voltage notification.
5.A, B can also be reinforced with screws, (A, bottom out, then screw in the bottom, buckle the
cover to the bottom, B can be directly fixed on the screw back.)
Before use, make sure the power switch of PIR motion sensors is at the ON position.
Installation height is about 2.2 meters above ground and the optimized detection angle for most
motion sensor is 90 degree. The sensor should face the detected area with this consideration for best
coverage. It is advised to install with the face of motion sensor perpendicular to the most probable
moving detection of people for the highest effective detection.
Installation:
Remove the supplied mounting bracket, keep the bracket is in line to the detector Bottom screw
holes, reinforce bracket with screws. Find the base and reinforce it with two screws in the wall.
Press the PIR
with bracket into the center hole of base. and then adjust the best angle of detecting. (This method is
suitable for engineering, installation)
Attention:
1. Within coverage of detection, there should be no any objects for obstruction.
2. There should be no two infrared detectors in the same as they will possibly intervene with each
other.
3.Avoid the detector facing window, cooling or warming machines, or other appliances that cause
the temperature changing sharply and thus cause false alarm.
4.Most infra-red detector needs about 5 minutes to heat up before READY for normal operation.
5.Regular PIR motion sensor is for indoor use unless the specification stated otherwise.Avoid to
face to air conditioner.
6.When intruder is detected, PIR will need few seconds to confirm, then transmitter the alarm signal
to avoid fault alarm and missed alarm.
7.Unless specifies otherwise, most infra-red detector are indoor use and not reliable to use outdoor.
8. Troubleshooting