The three-phase commercial inverter High efficiency at all output levels Highlights of the improved design –
offers more flexibility and control to Flat efficiency curves ensure high first time shown at Intersolar 2014
installers who have large installations efficiency at all output levels ensuring − − True three-phase bridge topology for
with varying aspects or orientations. consistent and stable performance DC/AC output converter
across the entire input voltage and − − Transformerless topology
The dual input section containing two, output power range. − − Each inverter is set on specific grid
independent Maximum Power Point codes which can be selected in the
Tracking (MPPT), allows optimal energy This device has an efficiency rating of field
harvesting from two sub-arrays oriented up to 98.2%. − − Detachable wiring box to allow an
in different directions. easy installation
The very wide input voltage range − − Wide input range
The TRIO features a high speed makes the inverter suitable for − − ‘Electrolyte-free’ power converter to
and precise MPPT algorithm for real installations with reduced string size. further increase the life expectancy
power tracking and improved energy and long term reliability
harvesting. In addition to its new look, this inverter
has new features including a special
built-in heat sink compartment and front
panel display system. The unit is free
of electrolytic capacitors, leading to a
longer product lifetime.
ABB string inverters
Additional highlights
−− Integrated string combiner with −− Capability to connect external
different options of configuration sensors for monitoring environmental
which include DC and AC disconnect conditions
switch in compliance with −− Availability of auxiliary DC output
international standards voltage (24V, 300mA)
− − Natural convection cooling for
maximum reliability
− − Outdoor enclosure for unrestricted
use under any environmental
conditions
IN1A(+)
MPPT 1 Inverter
IN1B(+) (DC/DC) Bulk caps (DC/AC)
+
IN1C(+)
IN1D(+)
*IN1E(+) -S2X version
Line Grid parallel
IN1 IN1 filter relay
IN1A(-)
IN1B(-) L1 L1 L1, S
IN1C(-) L2 L2 L2, S
-
IN1D(-)
L3 L3 L3, S
*IN1E(-)
Current N N,S
reading N
IN2A(+) PE PE
OVP MPPT 2
IN2B(+) monitoring + (DC/DC)
IN2C(+)
IN2D(+)
*IN2E(+)
IN2 IN2
IN2A(-)
IN2B(-)
IN2C(-)
-
IN2D(-)
*IN2E(-)
Current
reading
OVP
monitoring
DC/DC DC/AC
DSP DSP
-S2X version contr. contr.
Current reading
µP
OVP monitoring
Control circuit
PMU_RS485
+ T/R
PT 100
- T/R 1
GND
PT 1000
4...20mA / 0...10V adj PC_RS485
4...20mA / 0...10V adj + T/R
2
AN 1 Alarm
AN 2 N.C
IN mode N.O
C
Wiring box circuit
1 INVERTER
2 WIRING BOX
99
98
97
Efficiency [%]
96
95
93
500 Vdc
92
620 Vdc
91 800 Vdc
90
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%