Description
The 127 couples, 40mm × 40mm size single stage module is made of selected high performance ingots to
achieve superior cooling performance and greater delta T up to 70°C Designed for superior cooling and
heating. If higher operational temperature is required, please specify. We can design and manufacture custom
made modules according to your requirements. Please contact us for further information. Minimums do apply.
Features Application
● High effective cooling and efficiency. ● Food and beverage service refrigerator
● No moving parts, no noise, and solid-state ● Portable cooler box for cars
● Compact structure, small in size, light in weight ● Liquid cooling
● Environmental friendly, RoHS compliant ● Temperature stabilizer
● Precise temperature control ● Photonic and medical systems
● Exceptionally reliable in quality, high performance
Suffix Sealant
Positive lead wire (Red)
34.6±0.1
NS No sealing
40±0.1
TEC1-12706
Performance Curves at Th=27 ºC Performance Curves at Th=50 ºC
65 70
Imax = 6.1 A Imax = 6.1 A
60
52 I=5A I=5A
I=4A I=4A
50
I=3A I=3A
Qc / W
39 I=2A I=2A
40
Qc / W
I=1A I=1A
26
30
20
13
10
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
DT / °C DT / °C
Standard Performance Graph Qc= f(DT)
18 18
15 15
Voltage / V
12 12
Voltage / V
9 9
Imax = 6.1 A
Imax = 6.1 A
6 I=5A
6 I=5A
I=4A
I=4A
I=3A
I=3A
3 3 I=2A
I=2A
I=1A
I=1A
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
DT / °C DT / °C
Standard Performance Graph V= f(∆T)
65 70
o o
DT = 0 C DT = 0 C
o o
DT = 10 C 60 DT = 10 C
o
52 o
DT = 20 C DT = 20 C
o o
DT = 30 C DT = 30 C
o
50 o
DT = 40 C DT = 40 C
o o
DT = 50 C
Qc / W
39 DT = 50 C
Qc / W
o
DT = 60 C
40 o
DT = 60 C
o
DT = 70 C
26 30
20
13
10
0 0
0 2 4 6 8 10 12 14 16 2 4 6 8 10 12 14 16
Voltage / V Voltage / V
Standard Performance Graph Qc= f(V)
o
4 o
4 DT=30 C
DT=30 C o
o DT=20 C
DT=20 C o
DT=10 C
o DT=10 C
C. O. P
C. O. P
3 o 3 o
DT=0 C
DT=0 C
2 2
1 1
0 0
0 3 6 9 12 15 0 3 6 9 12 15
Voltage / V Voltage / V
Standard Performance Graph COP = f(V) of ∆T ranged from 0 to 30 ˚C
0.6 0.7
o
DT=70 C
0.5 DT=60 C
o 0.6 o
DT=60 C
o o
DT=50 C DT=50 C
o 0.5 o
0.4 DT=40 C DT=40 C
C. O. P
C. O. P
0.4
0.3
0.3
0.2
0.2
0.1 0.1
0.0 0.0
4 6 8 10 12 14 16 18 4 6 8 10 12 14 16 18
Voltage / V Voltage / V
Standard Performance Graph COP = f(V) of ∆T ranged from 40 to 60/70 ˚C
Remark: The coefficient of performance (COP) is the cooling power Qc/Input power (V × I).
Operation Cautions
● Cold side of the module applied on the object being cooled