Sie sind auf Seite 1von 6

Used values:

Main bar diameter = 16mm


Stirrup diameter = 12mm
Concrete cover = 40 mm
f’c = 28 MPa
fy= 414 MPa
β= 0.85
φ=0.9
Second to fourth floor - ALONG row 4-1:

POSITIVE MOMENT NEGATIVE MOMENT

Mu pos 112.1980693 kN-m Mu neg 86.65695369 kN-m


REMARKS design as singly-reinforced REMARKS design as singly-reinforced

SINGLY-REINFORCED BEAM DESIGN SINGLY-REINFORCED BEAM DESIGN

Rn 4.3136513 MPa Rn 3.3316783 MPa

ρ 0.0115872 ρ 0.0087069

ρmin 0.0033816 ρmin 0.0033816

use ρ 0.0115872 use ρ 0.0087069

As 984.91188 mm2 As 740.0854 mm2

n 5 n 4

n per layer 3 n per layer 4

Clear spacing 49 mm Clear spacing 27.333 mm

REMARKS: Using the Singly Reinforced Beam Analysis, use 5- 16mm diameter rebars
with beam dimensions of 250 mm x 400 mm.
POSITIVE & NEGATIVE MOMENT

Mu 41.41282925 kN-m
REMARKS design as singly-reinforced

SINGLY-REINFORCED BEAM DESIGN

Rn 1.264195031 MPa

ρ 0.003139328

ρmin 0.003381643

use ρmin 0.003381643

As 1389.385799 mm2

n 7

n per layer 4

Clear spacing 27.33333333 mm

REMARKS: Using the Singly Reinforced Beam Analysis, . Use 7- 16mm diameter rebars
with beam dimensions of 250 mm x 400 mm.

Second to fourth floor - ALONG Row 4-2:


POSITIVE MOMENT BEAM 1 POSITIVE MOMENT BEAM 2

Mu pos 141.6349183 kN-m Mu neg 252.5263026kN-m


REMARKS design as singly-reinforced REMARKS design as singly-reinforced

SINGLY-REINFORCED BEAM DESIGN SINGLY-REINFORCED BEAM DESIGN

Rn 5.4454025 MPa Rn 9.7088159 MPa

ρ 0.0151492 ρ 0.0328194

ρmin 0.0033816 ρmin 0.0033816

use ρ 0.0151492 use ρ 0.0328194

As 1287.6823 mm2 As 2789.6518 mm2

n 7 n 14

n per layer 4 n per layer 4

Clear spacing 27.333 mm Clear spacing 27.333 mm

REMARKS: Using the Singly Reinforced Beam Analysis, . Use 7- 16mm diameter rebars
with beam dimensions of 250 mm x 400 mm.
REMARKS: Using the Singly Reinforced Beam Analysis, . Use 14- 16mm diameter
rebars with beam dimensions of 250 mm x 400 mm.

Second to fourth floor - ALONG Row 5-1:


POSITIVE MOMENT NEGATIVE MOMENT

Mu pos 112.1980693 kN-m Mu neg 125.5049109kN-m


REMARKS design as singly-reinforced REMARKS design as singly-reinforced

SINGLY-REINFORCED BEAM DESIGN SINGLY-REINFORCED BEAM DESIGN

Rn 3.4466115 MPa Rn 4.8252561 MPa

ρ 0.0090352 ρ 0.0131619

ρmin 0.0033816 ρmin 0.0033816

use ρ 0.0090352 use ρ 0.0131619

As 767.98855 mm2 As 1118.7638 mm2

n 4 n 6

n per layer 4 n per layer 3

Clear spacing 27.333 mm Clear spacing 49 mm

REMARKS: Using the Singly Reinforced Beam Analysis, . Use 6- 16mm diameter rebars
with beam dimensions of 250 mm x 400 mm.

Second to fourth floor - ALONG Row 5-2:


POSITIVE MOMENT
Mu pos 626.96kN-m
REMARKS design as singly-reinforced
SINGLY-REINFORCED BEAM DESIGN
Rn 6.825614562 MPa
ρ 0.019947871
ρmin 0.003381643
use ρ 0.019947871
As 3770.147704 mm2
n 19
n per layer 6
Clear spacing 30 mm
REMARKS: Using the Singly Reinforced Beam Analysis, . Use 19- 16mm diameter
rebars with beam dimensions of 350 mm x 600 mm.

Second to fourth floor - ALONG Row 5-3:


POSITIVE MOMENT

Mu pos 194.800736 𝑘𝑁-m


REMARKS design as singly-reinforced
R
SINGLY-REINFORCED BEAM DESIGN

Rn 6.24121867 MPa

ρ 0.017845078

ρmin 0.003381643

use ρ 0.017845078

As 1820.197931 mm2

n 10

n per layer 5

Clear spacing 29 mm

REMARKS: Using the Singly Reinforced Beam Analysis, . Use 10- 16mm diameter
rebars with beam dimensions of 300 mm x 400 mm.