Then the precast reinforced member are shipped to the place where they are to be used here they are
hoisted set into their final places and assembled to from a complete structure.
3.what is module?
A unit of size in dimensional co-ordination for standardization od building materials and components .
BASIC Module is M=10cm=100mm.
The way new procedure for integrating the size of building materials and components so that may be
simplified as per basic module. M=10cm. It is the technique of the dimensioning system.
It is sum of acceptable positive and negative discrepancies of actual dimensions from the
theoretical one.
2-unit
1.what is dimensions of prefab components?
1.flooring and roofing scheme
2.Beam
3.columns
4.walls
5.staircase
6.lintels
7.sunshades/chajja projections
stressing.
3.What is loading?
When there is adhesion of create to the formwork some forces are development when is is not
really estimated it is assumed.
Qa=300kg/m².
Where,
Z≤h/2- is smallest distance b/w centre of gravity and edge of component. C1-
This slabs are tray shaped pre-cast floor panels. These are of two types a,narrow trays b,wide trays.8.
what is roofs?
Like convention roof, prefabricated slab roofs are also made. The structures supporting all covering
the area is known as over roof.
2,insulation
3,decorating.
3-UNIT
The prefabricates which have only one material are called homogenous prefabrication. The homogenous
unit may be hollow, solid,ribbed.
A prefabricate with more than one material is called a composite prefabricates. Also classified 1,soild
section 2, cored section 3,ribbed section.
There are difficulties and problem if the joints of various elements are not proper. It joints not
strong then the failure will occur in the structure.
Various structural elements are made in the plant or prefabricated when this element in their site
there may be joint deformation to take it workout deformation.
2. what is the rules are followed to decide the overall nominal degree of precision
of a prefabricates
1,from only one dimension is critical the degree of precision corresponding to the dimension of the
component.
2, when more than one dimension of the component are allowed tolerance or allowance.
5 2,concrete moulds-4-6
6.what the limiting value of allowances are calculated for the following formula.
Φ1=+b(l+0.66/l+b), Φ2=-2(l+0.6/l+b),
Φ3=+-5l/l+b, Φ4=+-5(l+0.6/l+b).
5-UNIT
1.What is collaspse
Assumption,stress strain curves, code condition.
The progressive collapse is not structural failure which is initialted or started by localized structural
damage and subsequently continuously develop as chain reaction into a failure that involves a major
portion of the structural system.
Progressive collapse is a situation were a local failure of a primary structural component leads to be
collapse of adjoining member which term leads to additional collapse.
5.what is the design load for considering abnormal effect such as what
Earthquake, cyclones.