Sie sind auf Seite 1von 2

SCHEME OF EVALUATION

Electrical Machinery (ELE-2103)


Test-1 Dated 14-09-2015

Q1 D. >99.5 1M
Q2 B 1M
Q3 A.600 kVA 1M
Q4 B.30 leading or C. 30 Lagging 1M
Q5 D. Phase Correction 1M

Q6 𝑉 200
𝑅𝑐𝐿𝑉 = = = 𝟓𝟕𝟏. 𝟒𝟑
𝐼0 𝑐𝑜𝑠 𝜑0 0.7 × 0.5

𝑉 200
𝑋𝑚𝐿𝑉 = = = 𝟑𝟐𝟗. 𝟗𝟐
𝐼0 𝑆𝑖𝑛 𝜑0 0.7 × 0.866
1M

𝑃𝑠𝑐 80
𝑅2𝑒 = 2 = 2 = 𝟎. 𝟖
𝐼𝑠𝑐 10

𝑁1 2 200 2
𝑅1𝑒 = 𝑅𝑒𝐻𝑉 × ( ) = 0.8 × ( ) = 𝟎. 𝟐
𝑁2 400

2
𝑋2𝑒 = √𝑍𝑒𝐻𝑉 2
− 𝑋𝑒𝐻𝑉 = 𝟏. 𝟐𝟔𝟖

𝑁1 2 200 2 1M
𝑋1𝑒 = 𝑋𝑒𝐻𝑉 × ( ) = 1.268 × ( ) = 𝟎. 𝟑𝟏𝟕
𝑁2 400

𝑃𝑐
Q7 𝐿𝑜𝑎𝑑 𝑓𝑎𝑐𝑡𝑜𝑟 𝑓𝑜𝑟 𝑚𝑎𝑥𝑖𝑚𝑢𝑚 𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦, 𝑥𝑚 = √ = 𝟎. 𝟗𝟑𝟓𝟒
𝑃𝑐𝑢𝐹𝐿

𝑥𝑚 × 𝑆 × cos 𝜑 1M
𝑀𝑎𝑥 𝐸𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦 (%) = = 𝟗𝟔. 𝟑𝟗%
𝑥𝑚 × 𝑆 × cos 𝜑 + 2 𝑃𝑐

𝑅2𝑒 1M
𝐹𝑜𝑟 𝑧𝑒𝑟𝑜 𝑉. 𝑅, cos 𝜑 = cos {tan−1 } = 𝟎. 𝟖𝟒𝟓𝟕 𝒍𝒆𝒂𝒅
𝑋2𝑒

Department of Electrical & Electronics Engg. 1 of 2


Q8 𝐶𝑜𝑟𝑒 𝐿𝑜𝑠𝑠 𝑝𝑒𝑟 𝑑𝑎𝑦 (𝑘𝑊ℎ) = 70 × 24 = 𝟏𝟔𝟖𝟎 𝑾𝒉

𝐶𝑜𝑝𝑝𝑒𝑟 𝐿𝑜𝑠𝑠 (𝑘𝑊ℎ) = [(10 × 0.7142 ) + (6 × 0.52 ) + (6 × 0.92 ) + (10 × 1.05262 )] × 80


= 𝟏𝟎𝟗𝟑. 𝟔𝟏 𝒌𝑾𝒉 1M

𝑂𝑢𝑡𝑝𝑢𝑡 (𝑘𝑊ℎ) = (2 × 103 ) × 10 + (2 × 103 × 0.5) × 6 + (3.6 × 103 ) × 6 + (4 × 103 ) × 2


= 𝟓𝟓𝟔𝟎𝟎 𝑾𝒉

55600
𝐴𝑙𝑙 𝑑𝑎𝑦 𝐸𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑦 (%) = = 𝟗𝟓. 𝟐𝟒%
55600 + 1680 + 1093.61 1M

Q9 2M
𝑍𝐴 + 𝑍𝐵 (0.07 + 𝑗0.245)
𝐿𝑜𝑎𝑑 𝑘𝑉𝐴 = 𝑆𝐴 × = 1000 × 103 × = 𝟏𝟒𝟎𝟎 𝒌𝑽𝑨
𝑍𝐵 0.05 + 𝑗0.175

Q10 𝑃𝑐 Equation for the line is,


𝑓
𝑃𝑐 1M
= 10 + 0.25𝑓
800 𝑓
40
𝐴 = 10; 𝐵 = 0.25

406.25 𝐻𝑦𝑠𝑡𝑒𝑟𝑖𝑠𝑖𝑠 𝐿𝑜𝑠𝑠 @50𝐻𝑧 = 𝐴 × 𝑓 = 𝟓𝟎𝟎 𝑾


25
𝐸𝑑𝑑𝑦 𝑐𝑢𝑟𝑟𝑒𝑛𝑡 𝑙𝑜𝑠𝑠 @50𝐻𝑧 = 𝐵 × 𝑓 2 = 𝟔𝟐𝟓 𝑾 1M

25 40 f

Department of Electrical & Electronics Engg. 2 of 2