Beruflich Dokumente
Kultur Dokumente
2. Intended use/es:
Self-supporting double skin metal faced insulating sandwich panels.
Roofs and roof cladding,
External walls and wall cladding,
Walls (including partitions) and ceilings within the building envelope.
3. Manufacturer:
Trimo d.o.o., Prijateljeva cesta 12, 8210 Trebnje, Slovenia.
5. System/s of AVCP:
System 1 (reaction to fire)
System 3 (other properties)
Certificate of constancy of performance issued by NB 1404-ZAG Ljubljana, No. 1404 - CPR - 2446.
Notified body/ies:
1404 – ZAG Ljubljana
1/5
7. Declared performance for Trimoterm Perform R, type FTV, FTV H, FTV HL, SNV, SNV 3L
MASS
TYPE
THICKNESS REFERENCE
FTV FTV H, FTV HL SNV SNV 3L
50 14,0 14,2 - -
60 15,0 15,2 16,3 15,4
80 17,0 17,2 18,3 17,4
100 19,0 19,2 20,3 19,4
120 21,0 21,2 22,3 21,4
133 22,3 22,5 - -
kg/m2
150 24,0 24,2 25,3 24,4
172 26,2 26,4 27,6 26,7
200 29,0 29,2 30,3 29,4
220 31,0 31,2 - -
240 33,0 33,2 - -
250 34,0 34,2 - -
MECHANICAL RESISTANCE
REDUCED COMPRESSIVE
SHEAR
SHEAR LONG TERM STRENGTH TENSILE
THICKNESS MODULUS REFERENCE
STRENGTH SHEAR (CORE) STRENGTH
(CORE)
STRENGTH
50 0,060 0,050 3,30
60 0,060 0,050 3,30
80 0,057 0,050 3,30
100 0,053 0,040 3,30
120 0,050 0,040 3,30
133 0,050 0,040 3,30
0,06 0,07 MPa EN 14509
150 0,050 0,040 3,30
172 0,050 0,040 3,30
200 0,050 0,040 3,30
220 0,050 0,040 3,30
240 0,050 0,040 3,30
250 0,050 0,040 3,30
THERMAL TRANSMITTANCE
THICKNESS FTV, FTV H, FTV HL SNV, SNV 3L REFERENCE
50 0,74 -
60 0,63 0,64
80 0,48 0,49
100 0,39 0,39
120 0,33 0,33
133 0,30 -
W/m2K EN 14509
150 0,26 0,27
172 0,23 0,23
200 0,20 0,20
220 0,19 -
240 0,17 -
250 0,16 -
FIRE RESISTANCE
WALL CEILING ROOF
THICKNESS REFERENCE
FTV FTV H, FTV HL FTV SNV SNV SNV 3L
50 NPD NPD NPD - - -
60 NPD EI20 NPD REI30 REI30 NPD
80 EI60 EI60 NPD REI30 REI30 NPD
100 EI120 EI120 EI120 REI120 REI120 REI30
120 EI120 EI120 EI120 REI120 REI120 REI30
133 EI120 EI120 EI120 - - -
EN 14509
150 EI180 EI180 EI120 REI120 REI120 REI30
172 EI180 EI240 EI120 REI120 REI120 REI30
200 EI180 EI240 EI120 REI120 REI120 REI30
220 EI180 EI240 EI120 - - -
240 EI180 EI240 EI120 - - -
250 EI180 EI240 EI120 - - -
WATER PERMEABILITY
WALL ROOF
THICKNESS REFERENCE
FTV, FTV H, FTV HL SNV, SNV 3L
All Class A (1200 Pa) Class B (900 Pa) EN 14509
AIR PERMEABILITY
WALL ROOF
THICKNESS REFERENCE
FTV FTV H, FTV HL SNV, SNV 3L
All n = 3,0: C= 0,0000000011 n = 0,8055: C= 0,008996 n= 1,00: C= 0,00019 EN 14509
8. The performance of the product identified above is in conformity with the set of declared
performance/s.
This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under
the sole responsibility of the manufacturer identified above.
Silvo Štih
Quality Assurance & HSE
Trebnje, 24.03.2017