Sie sind auf Seite 1von 1

Calumen® II 1.2.

4
15 March 2013
Data base : SGG Benelux

Glazing design
First glazing Second glazing

Gas Air 12.00mm

Coating

First glass PLANILUX 8.00mm PLANILUX 8.00mm

Coating PLANITHERM LUX

Layer
Outdoor Indoor

Coating

Second glass

Coating

Manufacturing sizes

ss
la
Nominal thickness : 28.0 mm
Weight : 40.0 kg/m²

Luminous factors (ISO 9050 m1.5) :

Transmittance :
Outdoor reflectance :
78
13
%
%

in G
a
Indoor reflectance : 12 %

ob
Energy factors (ISO 9050 m1.5) :

Transmittance : 57 %

G
Outdoor reflectance : 14 %

-
Indoor reflectance : 15 %

in t Absorptance A1 :
Absorptance A2 :
20
8
%
%

Sa
Thermal transmission (EN673-2011)
Solar factor g :
Shading coefficient :

Ug :
0.65
0.75

- 0° related to vertical position

1.7 W/(m².K)

NGUYEN THANH TRINH Phone : +84.43.7474727


EUROWINDOW J.S.C Mobile : 0988.069.353
Sales Department Fax : +84.43.7474728
Ly Nam De, Ha Noi, Viet Nam trinhnt76@yahoo.com
+84.43.7474727 Ha Noi

CALUMEN® II is a simulation software to calculate key performance of glass such as light transmission, solar factor or thermal insulation coefficient. Computed values are indicative
and subject to change. They can not be used to guarantee performance of the products.

These values are calculated according to EN410-2011 and EN673-2011 standards. Tolerances are defined according to EN 1096-4 or ISO9050 standards. Nevertheless, user must
check the feasibility of the associated products, in particular in terms of thickness and colour.
Furthermore, it is his responsibility to check that the resulting combination of glazing meets regulatory requirements at national, local or regional level.

Calculation rules and functional output of Calumen II have been validated by TÜV Rheinland Quality Report 11923R-11-33705

Das könnte Ihnen auch gefallen