CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Column Base Fasteners Near Two Edges Based on ACI 318-02
ANALYSIS
NUMBER OF GOVERNING FASTENERS n = 2
MAX TENSION ON GOV'G FASTENERS Nu = Mu/s - Pu/2 = 0 k
SHEAR FORCE ON GOV'G FASTENERS Vu = Vu, total / 2 = 2.5 k
2
EFFECTIVE AREA OF ONE FASTENER Ase = 0.142 in
2
BEARING AREA OF ONE HEAD Ab = 0.467 in , ( or determined from manufactures's catalogs.)
CHECK THE GOVERNING FASTENERS TENSILE STRENGTH :
where : f = 0.9
CHECK CONCRETE BREAKOUT STRENGTH OF GOVERNING FASTENERS :
fff
N ==+ A N yyyyy
A No
1 2 3N
AN
( 9h ef2 ) 1
æö
ç÷0.7
èø
0.3c min
1.5h ef 3 (24 '
f ch
where : f = 0.75
y4 term is 1.0 for location where concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH :
cmin > 0.4hef [Satisfactory]
Since the fasteners are located far from a free edge of concrete, c>0.4hef ,this type of failure mode is not applicable.
DETERMINE DESIGN TENSILE STRENGTH OF GOVERNING FASTENERS :
N n = min ( N s , N cb , N pn )
ffff = 10.363 K
ff
V s = n0.6 Ase f ut = 9.202 k > Vu [Satisfactory]
where : f = 0.9
CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD : (Cont'd)
fff
V cp ==+k cp
AN
yyy
2 3N b
A No
k cp
A N æö0.7
( 9hef2 ) ç÷
èø
0.3c min
1.5h ef 3 ( 24 '
f c hef1.5 )
= 20.166 k > Nu [Satisfactory]
where : f = 0.75
y3 term is 1.0 for location where concrete cracking is likely to occur.
kcp = 2.0 for hef > 2.5 in.
DETERMINE DESIGN TENSILE STRENGTH OF GOVERNING FASTENERS :
V n = min ( V s , V cb , V cp )
ffff = 2.693 K
Nu V
+= u 0.93 < 1.2 [Satisfactory]
ffN n Vn