Sie sind auf Seite 1von 14

SONOLINE G20

US

Configuration
Peripheral
Peripheral Configuration

© Siemens AG 2004
The reproduction, transmission or use
of this document or its contents is not
permitted without express written
Siemens Medical
Ultrasound
ejt DivisionSolutions
authority. Offenders will be liable for
damages. All rights, including rights
created by patent grant or registration
of a utility model or design, are
reserved.

Print No.: US06-202.843.01.01.02 English


Replaces: US06-101.841.01.01.02 Doc. Gen. Date: 10.05
n.a.

Part No.: n.a.


sd
2 Revision / Disclaimer
1Revision / Disclaimer

Copyright
Copyright © 2004 by Siemens Corporation. All rights reserved. No part of this publication
may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into
any language or computer language, in any form or by any means, electronic, mechanical,
magnetic, optical, chemical, manual, or otherwise, without the prior written permission of
Siemens Corporation. Siemens Corporation reserves the right to change its products and
services at any time. In addition, this manual is subject to change without notice. Siemens
Corporation welcomes customer input on corrections and suggestions for improvements
to this manual.Although Siemens Corporation has attempted to ensure accuracy through-
out this manual, Siemens Corporation assumes no liability for any errors or omissions, nor
for any damages resulting from the application or use of this information.
Trademarks
ACUSON, Sequoia, Cypress, AEGIS, Aspen, 128XP, XP, AcuNav, CV70, SONOLINE,
Adara, Antares, G20, G40, G50, G60S, Omnia and KinetDx are trademarks of Siemens
Corporation registered in the U.S. Patent and Trademark Office. CWS3000, DS3000,
WS3000, and WebPro are trademarks of Siemens Corporation.
Windows XP, 2000 and NT are registered trademarks of Microsoft Corporation. Internet
Explorer is a trademark of Microsoft Corporation. Netscape and Netscape Navigator are
registered trademarks of Netscape Communications Corporation. Java and the JavaScript
name are registered trademarks of Sun Microsystems, Inc. Adobe Acrobat is a registered
trademark of Adobe Systems, Inc.
Other products and brand names are trademarks of their respective owners.
Disclaimer
The service of equipment described herein is to be performed by qualified personnel who
are employed by Siemens or one of its affiliates or who are otherwise authorized by Sie-
mens or one of its affiliates to provide such services.
Assemblers and other persons who are not employed by or otherwise directly affiliated
with or authorized by Siemens or one of its affiliates are directed to contact one of the
local offices of Siemens or one of its affiliates before attempting installation or service pro-
cedures.
License Agreement
All computer programs copyright 1990-2004 by Siemens Corporation or its suppliers. Pro-
grams are licensed under the following agreement:
Siemens or its suppliers retain(s) ownership of and title to any computer program supplied
with the equipment and to the trade secrets embodied in such computer programs. Sub-
ject to the Buyer’s acceptance and fulfillment of the obligations in this paragraph, Siemens
grants the Buyer a personal, non-transferable, perpetual, non-exclusive license to use any
computer program supplied with the Equipment that is necessary to operate the Equip-
ment solely on the medium in which such program is delivered for the purpose of operat-
ing the equipment in accordance with the instructions set forth in the operator’s manuals
supplied with the Equipment and for no other purpose whatsoever. Buyer may not
reverse-assemble, reverse-compile or otherwise reverse-engineer such computer pro-
grams nor may Buyer make a copy of such program or apply any techniques to derive the
trade secrets embodied therein. In the event of a failure by Buyer to comply with the terms

SONOLINE G20 US06-202.843.01.01.02 Page 2 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Revision / Disclaimer 3

of this license, the license granted by this paragraph shall terminate. Further, because
unauthorized use of such computer programs will leave Siemens without an adequate
remedy at law, Buyer agrees that injunctive or other equitable relief will be appropriate to
restrain such use, threatened or actual. Buyer further agrees that (i) any of Siemens"s
suppliers of software is a direct and intended beneficiary of this end-user sublicense and
may enforce it directly against Buyer with respect to software supplied by such supplier,
and (ii) No supplier of Siemens shall be liable to buyer for any general, special, direct, indi-
rect, consequential, incidental or other damages arising out of the sublicense of the com-
puter programs supplied with the equipment.

Siemens US06-202.843.01.01.02 Page 3 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
4 Table of Contents
1- 0Table of Contents

1 _______ Removing and Replacing Peripherals _______________________________ 5

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Remove and Replace the P93W Black and White Printer . . . . . . . . . . . . . . . . . . . . . 5
Remove and Replace the HS-MD3000 VCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

SONOLINE G20 US06-202.843.01.01.02 Page 4 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Removing and Replacing Peripherals 5
2-
Overview
1Removing and Replacing Peripherals

Remove and Replace the P93W Black and White Printer 0

Remove the P93W Black and White Printer

1. Power off the system, switch off the MAINS circuit breaker, and leave the power cord
connected to the wall outlet.
2. Disconnect the following cables from the printer: power cord, BNC cable, and the print-
er control cable.
3. Loosen the printer mounting bracket captive screw, slide the mounting bracket out from
the OEM shelf, and lift the printer mounting bracket and printer off the OEM shelf.

Re-install the P93W Black and White Printer

1. Turn the P93W printer upside down and remove the four plastic printer feet by unfas-
tening the screws.
2. Secure the mounting bracket on to the bottom of the P93W using four thumbscrews and
four spring washers.
- To mount the P93W printer with the front of the printer facing the left side of the G20
system, attach the mounting bracket as shown in Figure 1.

WARNING It is required to use the supplied thumb screws.


¹ Use of incorrect hardware can lead to a safety hazard,
such as electrical shock.

Siemens US06-202.843.01.01.02 Page 5 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
6 Removing and Replacing Peripherals

Fig. 1: Leftward Configuration


Pos. A Mounting bracket
Pos. B Thumbscrew and spring washer
Pos. C Plastic printer feet

- To mount the P93W printer with the front of the printer facing the right side of the G20
system, attach the mounting bracket as shown in Figure 2.

Fig. 2: Rightward Configuration


3. Place the P93W printer on its feet.

SONOLINE G20 US06-202.843.01.01.02 Page 6 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Removing and Replacing Peripherals 7

4. Connect the printer power cord between the printer and the accessory outlet of the sys-
tem.
- Connect the AC power cord to the AC inlet of the printer.
- Connect the other end of the cord to the OEM shelf AC outlet.

Fig. 3: OEM Shelf (viewed from the left side of the system)
Pos. A OEM AC power outlet
Pos. B OEM bracket mounting slots
Pos. C OEM shelf hole for routing cables to the I/O panel
Pos. D I/O panel

5. Route the BNC and remote cables down through the hole in OEM shelf and to the I/O
panel on the left side of the system.
6. Connect the BNC and remote cables between the printer and the I/O panel.

Fig. 4: BNC and Remote Cable Connections


Pos. A BNC cable connection
Pos. B Remote cable connection

Siemens US06-202.843.01.01.02 Page 7 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
8 Removing and Replacing Peripherals

7. Set the printer dip switch as follows: 1-on, 2-off, 3-off, 4-off, 5-off, and 6-off.

Fig. 5: Printer Dip Switch Configuration


8. Attach the assembled printer mounting bracket to the OEM shelf.
- Slide the two mounting bracket tabs into the mounting slots.

Fig. 6: Printer Mounting Bracket Tabs

CAUTION Be careful not to pinch or damage the cables.


¹ Check that the power cable is routed between the printer
and the back of the OEM shelf.

SONOLINE G20 US06-202.843.01.01.02 Page 8 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Removing and Replacing Peripherals 9

- For the leftward configuration of the printer, route the BNC and remote cables under
the printer.

Fig. 7: Thumbscrew (leftward configuration shown)


- Tighten the thumbscrew to secure the bracket to the OEM shelf.

Verify the Operation of the P93W Printer

1. Plug the system AC power cord to the wall outlet.


2. Connect an arbitrary transducer to the system.
3. Switch on the MAINS breaker and press the Standby button to power on the G20 sys-
tem.
4. Confirm that a 2D-image is displayed on the monitor.
5. Press the printer power switch to power on the printer.
6. Press the F6 key; the Preset Main Menu is displayed.
7. Select Customize Keys.
8. In the Print/Store Key selection click B/W Printer.
9. Click Save.
10. Press the Print key and confirm that the 2D-image on the monitor is printed correctly on
the P93W.

Remove and Replace the HS-MD3000 VCR 0

Remove the HS-MD3000 VCR

1. Power off the system, switch off the MAINS power circuit breaker, and leave the power
cord connected to the wall outlet.
2. Disconnect the following cables from the VCR: AC power cable, S-Video In cable,
S-Video Out cable.

Siemens US06-202.843.01.01.02 Page 9 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
10 Removing and Replacing Peripherals

3. Remove the VCR mounting bracket assembly from the OEM shelf.
- Loosen the two captive screws that secure the VCR bracket to the OEM shelf.
- Slide the two VCR bracket tabs out from OEM shelf slots and lift the VCR bracket off
from the VCR.
- Lift the VCR off the G20 OEM shelf.

Re-install the HS-MD3000 VCR

Fig. 8: VCR Assembly (viewed from the rear)


Pos. A HS-MD300 viewed from the top
Pos. B HS-MD300 viewed from the bottom
Pos. C Mounting bracket
Pos. D VCR feet
Pos. E VCR foot screws

1. Turn the HS-MD3000 VCR upside down and remove the four plastic VCR feet by unfas-
tening the screws.
2. Secure the mounting bracket on to the bottom of the HS-MD3000 VCR using four
screws and spring washers remove from the VCR feet.

WARNING It is required to use the supplied thumb screws.


¹ Use of incorrect hardware can lead to a safety hazard,
such as electrical shock.

SONOLINE G20 US06-202.843.01.01.02 Page 10 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Removing and Replacing Peripherals 11

- To mount the HS-MD3000 VCR mounting bracket assembly with the front of the VCR
facing the left side of the G20 system, attach the mounting bracket as shown in Fig-
ure 9.

Fig. 9: Leftward Configuration


- To mount the HS-MD3000 VCR mounting bracket assembly with the front of the VCR
facing the right side of the G20 system, attach the mounting bracket as shown in Fig-
ure 10.

Fig. 10: Rightward Configuration


3. Place the HS-MD3000 VCR mounting bracket assembly on its feet.
4. Connect the VCR AC power cord between the VCR and the accessory outlet of the sys-
tem.
- Plug the AC power cord into the AC inlet of the VCR.
- Plug the other end of the cord into the OEM AC outlet.

Siemens US06-202.843.01.01.02 Page 11 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
12 Removing and Replacing Peripherals

Fig. 11: OEM Shelf (viewed from the left side of the system)
Pos. A OEM AC power outlet
Pos. B VCR bracket mounting slots
Pos. C OEM shelf hole for routing cables to the I/O panel
Pos. D I/O panel

5. Route the S-Video In and S-Video Out cables down through the hole in OEM shelf and
to the I/O panel on the left side of the system.
6. Connect the -Video In and S-Video Out cables between the VCR and the I/O panel.

SONOLINE G20 US06-202.843.01.01.02 Page 12 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.
Removing and Replacing Peripherals 13

Fig. 12: S-Video Cable Connections


Pos. A VCR S-Video In - I/Opanel Video Out
Pos. B VCR S-Video Out - I/Opanel Video In

7. Set the VCR Video and S-Video 75 ohm switches to on.


8. Attach the VCR assembled VCR mounting bracket to the OEM shelf.
- Slide the two mounting bracket tabs into the OEM shelf slots.

Fig. 13: VCR Mounting Bracket Tabs

Siemens US06-202.843.01.01.02 Page 13 of 14 SONOLINE G20


Medical Solutions USA, Inc. 10.05 sd
14 Removing and Replacing Peripherals

CAUTION Be careful not to pinch or damage the cables.


¹ Check that the power cable is routed between the VCR
and the back of the OEM shelf.

- For the leftward configuration of the VCR, route the S- Video In and S-Video Out ca-
bles under the VCR/top cover assembly.
- Tighten the thumbscrew to secure the VCR to the OEM shelf.

Verify the Operation of the HS-MD3000 VCR

1. Plug the system AC power cord to the wall outlet.


2. Connect an arbitrary transducer to the system.
3. Switch on the MAINS breaker and press the Standby button to power on the G20 sys-
tem.
4. Confirm that a 2D-image is displayed on the monitor.
5. Press the VCR power switch to power on the VCR.
6. Insert an S-Video tape into the VCR. Make sure the videotape is fully rewound.
7. Simultaneously press REC and PLAY on the VCR to record the displayed image.
8. Press STOP to stop the recording.
9. Press REW to rewind the videotape.
10. Press Video I/O key on the control panel, and then PLAY on the VCR to review the re-
corded image. Confirm that the recorded image can be reviewed without problems.

SONOLINE G20 US06-202.843.01.01.02 Page 14 of 14 Siemens


10.05 sd Medical Solutions USA, Inc.