SUMMER FANS

CFM of fan at
Volume of the Required air
Length Height (Avg) Cross section Actual CFM required static
Width (ft) house (Cubic ft of speed Resultant
(ft) (ft) of the house of the house pressure (0.08
air to be handled) (ft/min)
IN.WG)
Fans
351 45.93 10.33 166534.3719 474.4569 400 189782.76 22250 8.52956225

AIR EXCHANGE RATE


CFM of fan
at required
Total (Cubic ft of Air exchange
static
fans in air to be Total CFM of fans rate of a
pressure
use handled) minute
(0.08
IN.WG)

Time 8.5296 22250 166534.372 189782.76 0.8775


Calculate number of fans and air inlet required in a poultry house
Length Width Height (Avg) Crossection Volume Required Air Speed

If Measurements are in Feet:


Wall Centre Avg.
Avg.
Meter Feet Meter Feet height height Height M² Ft² M³ Ft³ Ft / Min M/Sec
Height (M)
(Ft) (Ft) (Ft)

100 328 14 45.93 7.2 12 9.8 2.97 41.60 447.82 4159.45 146884 400 2.03
Air inlet required:
Total air inlet area
Total CFM of fans installed Standard for 6" cool pads 45˚ x 45˚ or 30˚ x 30˚ Air inlet area / side (M)
(M)

CFM of each
No. Of
fans
fan at 0.08 Total CFM
INWG
400 CFM / 1 Ft² of the Fans CFM 41 21
8 22200 177600
To Calculate number of fans required on day to day basis: (After brooding period)
CFM required /
Total Birds Avg.Wt (Kg) CFM of installed fan No of fans required
Kg

28000 0.45 6 25000 3.024


use
Avaiable Fan
Number
CFM @ .08
of fans Total air inlet
INWG static
required
pressure

CFM Numbers

22250 8 41.6
Calculate number of fans based on building and equipment
If Measurements are in Meters:
Avaiable
Fan CFM @
Required Air
Length Width Height (Avg) Crossection Volume .08 INWG
Speed
static
pressure

Wall Centre Avg. Avg.


Meter Feet Meter Feet height height Height Height M² Ft² M³ Ft³ Ft / Min M/Sec CFM
(M) (M) (M) (Ft)

100 328 14 46 2.2 3.8 3 9.76 41.65 448.31 4165 147080 492 2.5 23800
If Measurements are in Feet:
100 328 14 46 7.2 12 9.8 2.97 41.60 447.82 4159.45 146884 500 2.54 23800
Number
of fans
required

Numbers

9
Number of fans based on Density
Avaiable
Standard
If Measurements are in Meters: Required Air
Fan CFM @
Density
.08 INWG Total meat
Speed CFM /
static
Meat Kg of
pressure
Length Width Height (Avg) Meat
Area
Volume
Wall Centre Avg. Avg. (M²
(M³ or Feet³)
Meter Feet Meter Feet height height Height Height or Feet²) Ft / Min M/Sec CFM Kg / M²) Kg
(M) (M) (M) (Ft)

100 328 14 46 2 4 3 10 1400 4200 394 2.0

If Measurements are in Feet: 23800 30 42000 5

100 328 14 46 6.5 13 9.75 2.97 15065 146884 400 2.03


Number
CFM for
of fans
Total Meat
required

210000 9
Air inlet required: (Cool Pad Area)
Total air Air inlet
Standard for 6" cool pads
Total CFM of fans installed inlet area area / side
45˚ x 45˚ or 30˚ x 30˚
(M) (M)

No. Of CFM of each fan at


fans 0.08 INWG Total CFM

400 CFM / 1 Ft² of the Fans CFM 44 22


8 23800 190400
Side Wall Air Inlets

Size of House Size of inlet Standard CFM


N⁰ of CFM of installed CFM of Total inlet area Number of
from 15 Feet²
Fans fan 50% Fans (feet²) inlets
Length Width Length Width Area inlet
(Feet) (Feet) (Inches) (Inches) (Feet²)

328 46 44 8 2.4 9 23800 95200 10000 142.8 58

Remarks
1. 48 Inch fans CFM is 23800
2. In general 15 feet² area is required to have 10000 CFM
3
Remarks

Static pressure will


be 0.08 INWG
To Calculate number of fans required on day to day basis: (After brooding period)

CFM required / CFM of installed


Total Birds Avg.Wt (Kg) No of fans required
Kg fan

28000 0.45 6 25000 3.024


r brooding period)

No of fans required

3.024
Production Number = (Liveability % x Avg Weight / F.C.R x Catching Age ) x

S.no Description Value Remarks Change values in

1 Liveability % 95 (Total Birds Placed - Mortality) / 100 Mortality %

2 Avg Weight 1 Total Live weight / Number of Birds Total live weight

3 F.C.R 1.60 Total Feed consumed / Total live Weight Total feed consumed

4 Catching Age 30 Catching age

5 Production Number 198.15


R x Catching Age ) x 100

Change values in Red color

5 Liveability 26030

26030 Number of birds placed 27400

41600 Avg weight 1

30