Sie sind auf Seite 1von 6

SJ300 SERIES APPLICATION SAMPLE

APPLICATION : GEAR PUMP


CUSTOMER : COMPANY V MODEL:SJ300-300HFE
KEY OF ADOPTING SJ300:
- S L V(HIGH TORQUE AT LOW FREQUENCY AND WIDE RANGE OF
CONTINUOUS TORQUE 100% WITHOUT ENCODER FEEDBACK)
- QUICK SPEED RESPONSE
- TORQUE LIMIT 50 TO 75% FOR PROTECTION OF MACHINE
SYSTEM COMPOSITION
VARIABLE FLOW RATE FROM CONSTANT-FLOW PUMPS

IN GEAR PUMP

MOTOR

IN
INVERTER

OUT
OUT

ENERGY SAVING HYDRAULIC ASSEMBLY FOR PRODUCING VARIABLE


FLOW RATES FROM SPEED-CONTROLLED CONSTANT-FLOW PUMPS
IN THE COMBINATION J300 INVERTER + INDUCTION MOTOR + GEAR
PUMP.

APPLICATION EXAMPLE
PLASTICS INJECTION BOULDING MACHINE WITH HYDRAULIC
GEAR PUMP.
DATA
ON KEY POINTS OF FUNCTION SETTING FUNCTION DEFAULT FINAL
SETTING SETTING
1. HIGH TORQUE AND WIDE RANGE OF AO44 00(V C) 03(S L V)
CONTINUOUS TORQUE 100%
TORQUE (1ST
CONTROL)
CONTINUOUS TORQUE
(%)
100

6 50 (HZ)
(60)

2. QUICK SPEED RESPONSE H005 1.59 5.16


SPEED
2-1 UNDER SHOOT & OVER SHOOT
LOAD RESPONSE
(%)
100
AFTER
t 1ST MOTOR
0 CONSTANT AUTOTUNING
H034 0.08 0.2
SPEED J

△N2
N
△N1
t

△N1 (△N2) X100 ≦ 5 (%)


N

FREQUENCY
(HZ)
50
10 t
0
SPEED

200ms 400ms
2-2 QUICK ACCELERATION &
DECELERATION WITH LOAD

DATA
NO KEY POINTS OF FUNCTION SETTING FUNCTION DEFAULT FINAL
SETTING SETTING
3. TORQUE LIMIT 50 TO 75% b041 150 75

TORQUE ∫
TORQUE LIMIT
LEVEL 1 50
SETTING
FORWARD
-DRIVING
AT
4 QUADRANT
MODE

0
225 900 1500 1800 SPEED
(r/m)

Das könnte Ihnen auch gefallen