IN GEAR PUMP
MOTOR
IN
INVERTER
OUT
OUT
APPLICATION EXAMPLE
PLASTICS INJECTION BOULDING MACHINE WITH HYDRAULIC
GEAR PUMP.
DATA
ON KEY POINTS OF FUNCTION SETTING FUNCTION DEFAULT FINAL
SETTING SETTING
1. HIGH TORQUE AND WIDE RANGE OF AO44 00(V C) 03(S L V)
CONTINUOUS TORQUE 100%
TORQUE (1ST
CONTROL)
CONTINUOUS TORQUE
(%)
100
6 50 (HZ)
(60)
△N2
N
△N1
t
FREQUENCY
(HZ)
50
10 t
0
SPEED
200ms 400ms
2-2 QUICK ACCELERATION &
DECELERATION WITH LOAD
DATA
NO KEY POINTS OF FUNCTION SETTING FUNCTION DEFAULT FINAL
SETTING SETTING
3. TORQUE LIMIT 50 TO 75% b041 150 75
TORQUE ∫
TORQUE LIMIT
LEVEL 1 50
SETTING
FORWARD
-DRIVING
AT
4 QUADRANT
MODE
0
225 900 1500 1800 SPEED
(r/m)