Sie sind auf Seite 1von 1

pv fluid products

Specification sheet for:


6 3/4” 4:5 Lobe 7.0 Stage HS88 Group 0 PV675470-HS-0
PRELIMINARY ENGINEERING SPEC
Rotor Details FOR INFORMATION ONLY
Recommended Operating Range
Specification Sheet for:
Overall Length (in) 202.5 Flow Rate 300 gpm-600 gpm
Head Length (in) 6 3/4" 4:5 Lobe 7.0 Stage HS88 Group 0
6.00 No Load RPM 150-300
Head Diameter (in) 4.00 Displacement 0.5 revs/gal
Contour OD (in) Rotor Details 4.220 Max WorkingRecommended Operating Range
Pressure 1260 psi
Ecc (in) Overall Length (in) 202.5
0.354 Max Off-BTMFlow Rate
Pressure 300 gpm-600 gpm
101 psi
C to V (in) Head Length (in) 6.00
3.512 No Load RPM
Max Operating Torque 150-300
5571 ft-lbs
Head Diameter (in) 4.00 Displacement 0.5 revs/gal
Weight (lbs) Contour OD (in) 520.0
4.220 Torque Slope
Max Working Pressure 4.643
1260 psift-lbs/psi
Std Connection Ecc (in) 2 0.354
7/8" Reg Max Operating pressure = Max Working psi - Max Off-BTM psi
Max Off-BTM pressure 101 psi
C to V (in) 3.512 For maximum life do not exceed 1159
Max Operating Torque psi differential.
5571 ft-lbs
Weight (lbs) 520.0 Torque Slope 4.643 ft-lbs/psi
Std Connection 2 7/8" Reg Max Operating pressure = Max Working psi - Max Off-BTM psi
Stator Details Sizing and Fit Information
For maximum life do not exceed 1159 psi differential.
Overall Length (in) Stator Details 214.6 Vector Minor (in) 3.507
Tube OD (in)Overall Length (in) 6.75
214.6 Shop Fit @ 70°F Sizing & Fit Information
0.005 Compression
Tube ID (in) Tube OD (in) 6.75
5.50 TempVector Minor (in)
Correction Factor* 3.5073.5
Tube ID (in) 5.50 Shop Fit @ 70°F 0.005 Compression
Alternate OD (in) 7.00
Alternate OD (in) 7.00 Temp Correction Factor*
* Temp correction factor is the degrees (F) required3.5
to change the stator size
Std CutbacksStd Cutbacks
(in) (in) 8.00
8.00 by .001” on diameter.
* Temp correction factor is the degrees (F) required to change the stator size
Weight (lbs) Weight (lbs) 815
815 by .001" on diameter.

Theoretical performance with water at Operating Temperature


Theoretical peformance with water at Operating Temperature

350 6000

300
5000

250
4000

Torque (Ft-lbs)
200
RPM

3000
150

2000
100

1000
50

0 0
0 200 400 600 800 1000 1200 1400
Differen7al Pressure psi
y
Data is based on new rotor and stator
nominal dimensions. Performance RPM @ 300 gpm RPM @ 600 gpm Torque Max Diff
downhole may vary based on drilling
conditions and rotor/stator fit.
Performance curves for reference only. Data is based on new rotor and stator nominal dimensions. Performance downhole may vary based on
Operating over the specified limits may
result in damage to the power section
drilling conditions and rotor/stator fit. Operating over the specified limits may result in damage to the power section and/or connected components.
and/or connected components.
Information is subject to change.
©2015Copyright 2013 PV Fluid Products Ltd. All Rights Reserved.
PV Fluid Products Ltd. All rights reserved. For more information visit www.pvfluid.com Data current as of November 2016.
For more information visit www.pvfluid.com Data current as of 26-Sep-2016