STUF-200H

HANDHELD ULTRASONIC FLOWMETER


- Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Features and Benefits:


• Hi g h acc ur ac y, ± 1 % o f ve lo c it y
• NI ST S ta nd ar d
• No n -i n tr us i ve, cl a mp -o n
in s ta lla tio n , ea s y a nd fa st. No p ip e
d is t ur b a nc e, no p r e ss ur e d r o p , no
mo v i n g p ar t s
• Li g ht we i g ht ( 1 .2 lb s/5 3 8 g fo r t he
ha nd se t) . Co mp ac t d e si g n
• B i- d ir e ct io na l, wi d e r a n ge,
-5 2 f t/ s ~ 5 2 ft / s ( -1 6 m/ s ~ 1 6 m/ s)
• W id e p ip e si ze r a n g e, 1 " ~ 2 4 0 "
( DN2 5 ~ D N6 ,0 0 0 m m)
• S ui tab l e fo r al l co m mo n l y us ed
p ip e ma ter ia ls a nd liq u i d s.
• Re c har ge ab le b a t ter y f o r 1 0 ho u r s
o f o p er at io n.
• B ui lt - i n d a ta lo g ger .
• T o taliz er fo r n et, p o s it i ve a nd
ne g at i ve f lo w
• Sel f - e xp l a na to r y u ser i n ter fa ce.
Ver y e a s y to o p er a te.
• Op t io nal S t u fM a na ger T M P C so ft war e fo r d a ta d o wn lo ad a nd r e al - ti me d a ta d i sp la y.
• Si g n al q ua li t y tr a c k i n g and s el f - ad j u st i n g c ap ab ili ti e s a u to mat ic al l y ma t ch tr a n sd uc er
to p ip e ma ter ial
• Ca n al so b e d ep lo ye d a s a r e mo te RT U fo r lo n g - ter m f lo w mo ni to r i n g ap p lic at io n
• I d eal fo r flo w s ur ve y, H V AC, f lo wme t er ver i fi c atio n a nd a ll o t her ap p l i cat io ns wh e r e
b o t h ac c ur ac y a nd p o r ta b ili t y a r e e s se n ti al .

T he ST U F -2 0 0 H Ha n d he ld U ltr aso n ic B es id e s, t h e u niq u e c la mp -o n f i xt u r e


Flo wme ter i s o ne o f t he mo st p o we r f ul d es i g n ma k es t he i n st al l atio n v er y
f lo wme ter s a va ilab le fo r liq u id si mp le a nd no sp ec ia l s k ill s o r to o ls
me a s ur e me n t. T he u ti liz atio n o f o ur r eq u ir ed . D u e to t he no n - i ntr u si v e
p r o p r iet ar y u ltr a so n ic si g na l p r o c es s i n g, na t ur e o f t he cl a mp -o n t ec h niq ue ,
tr a n si t -t i me mea s ur e me n t a nd si g n al th er e i s no p r e s s ur e d r o p , no mo vi n g
q ua li t y t r ac k i n g t ec h no l o gi e s a llo ws t he p ar t s, no lea k s a nd no c o nt a mi n at io n.
f lo wme ter to me a s ur e li q ui d flo w r a te
S he n ite c h o f fer s S t u fMa na g er T M P C
fr o m o ut sid e o f a p ip e r eli ab l y a nd
so ft war e to f ac il ita te t h e u s e o f a nd to
acc ur a te l y.
exp lo r e t he f u ll p o te n ti a l o f ST UF -
2 0 0 H flo wme ter . T hi s s o f t wa r e
T he ST U F -2 0 0 H flo wme ter is car e f ul l y
au to ma ti cal l y e s tab l i s he s t h e
d es i g ned so t hat it i s ve r y co mp ac t a nd
co n n ect io n b e t we e n t he f lo wme ter a nd
eas y to u se . Yo u ca n u se o n e ha nd to
yo ur P C. I t a l so a llo ws yo u to
ho l d a s we l l a s to o p er at e t he f lo wme ter
d o wn lo ad d at a fr o m t he f lo wme ter ’ s
ma i n u n it. T he u ser i n te r fa ce i s sel f -
d ata lo g ger to yo ur P C a nd co n ver t t he
exp la na to r y a nd ver y ea s y to fo l lo w.
d ata i nto s ta nd ar d sp r ea d s hee t.
Applications:
T he ST U F -2 0 0 H flo wme ter is id e al fo r flo w s ur v e ys a nd c lo s ed -p ip e ap p l ica tio n s wh er e
no n - i n va si v e mea s ur e me nt o f l iq uid s i s r eq u ir ed . B en e fi ted fr o m o ur ad v an ced d i gi tal
si g n al p r o ce s si n g tec h no lo g y, t h e ha nd he ld f lo wme ter wo r k s r eli ab l y i n b o t h cl ea n a nd
o p aq u e l iq uid f lo w. E xa mp le s o f ap p li ca tio n s i n c l ud e :
• W ater , i nc l ud i n g ho t wa ter , c hi lled wa ter , ci t y wa t er , sea wa ter , e tc.
• Se wa ge a nd d r a i na ge wa ter wi t h s mal l p a r t icl e q ua n ti t y.
• Oil , i n cl ud i n g cr ud e o i l, l ub r i cat i n g o il, d ie se l o il, f u el o il , e tc.
• C he mi c al s, i ncl ud i n g a l co ho l, a cid s, et c.
• So l v e nt s.
• B ev er a ge a nd fo o d p r o c es so r s.
• HV AC ho t a nd co o l wa t er ,
wa t er / g l yco l so l ut io n s.
• W ater a nd wa s te tr e at me nt .
• P o wer p l a nt s ( n uc le ar p o wer p la nt s, Carrying Case
th er ma l & h yd r o p o wer p la nt s) , h ea t
en er g y b o i ler f eed wa ter
• En er g y co n s u mp tio n s up er v i sio n a nd Handset
wa t er co n ser v at io n ma n ag e me n t
• Met al l ur g y a nd mi n i n g a p p lic at io ns
( e. g., a cid r eco ve r y) HS-type
Clamp Xducer
• Mar i n e o p er at io n a nd m ai nt e na nc e Fixture
• P ulp a nd p ap er Tape
• P ip eli n e l ea k d ete ct io n, in sp ect io n, Xduer
Ruler
RS232
tr ac k i n g a nd co l lec tio n Cable Cable
Charger
• En er g y me as ur e me n t a n d b ala n ci n g
• W ater d i str ib ut io n ne t wo r k
mo n ito r i n g

Specifications:

Linearity Better than 1%

Repeatability 0.5%

Accuracy ±1% of velocity reading or ±10mm/s, whichever is bigger

Response Time 0-999 seconds, user-configurable

Velocity -52ft/s ~ +52ft/s (-16m/s ~ +16m/s), bi-directional

Pipe Size 1" ~ 240" (DN25mm ~ DN6,000mm)

Pipe Material All metals, most plastics, lined pipe

Units English (U.S.) or metric

Totalizer Three 7-digit totalizers for totalizing net, positive and negative flows

Liquid Types Virtually all liquids (full pipe)

Liquid Temp 32˚ F ~ 176˚ F (0˚C ~ 8 0˚C) or 32˚ F ~ 312˚ F (0˚C ~ 155˚C), depending on
transducer type
Security Setup Modification Lockout. Access code needed for unlocking

Display 4x16 letters

Digital Interface OCT digital output, can be configured as frequency or pulse output
RS-232C: serial communication port with simplified flowmeter protocol
StufManager TM (optional): Windows PC software for data download and
real-time data acquisition
Transducers Refer to Optional Transducers section for more details

Transducer Cord Standard 2x15' (2x5m). Extension cable available upon request

Power Supply 3 AAA Ni-H built-in batteries. When fully recharged, it will last over 10
hours of operation
100V-240VAC for the charger
Data Logger Built-in data logger can store over 2,000 lines of data

Housing Material Aluminum alloy protective case. Suitable for normal and harsh environment

Case Size 7.9"x3.6"x1.3" (200mmx92mmx32mm)

Handset Weight 1.2 lbs (538g) with batteries

How does the STUF-200H flowmeter work?


T he ST U F -2 0 0 H flo wme ter is b a sed o n tr a n si t -
ti me mea s ur e me n t p r i n ci p le, a s s ho wn i n t he
fo llo wi n g f i g ur e.

A t yp ica l t r a n si t -t i me f l o w mea s ur e me n t s ys te m
ut il iz es t wo tr a nsd u cer s ( A a nd B ) t ha t f u nc tio n
as b o t h ul tr a so n ic tr a n s mi t ter a nd r ec ei v er . T h e
tr a n sd ucer s ar e cla mp ed o n t he o u t sid e o f a clo s ed
p ip e a t a sp eci f ic d i st a n ce fr o m eac h o t her . T he
Z-method
f lo w me t er o p er ate s b y alt er na tel y tr a n s mi t ti n g
and r ec ei v i n g a co d ed b ur st o f so u nd e ner g y
b et we e n t he t wo tr a n sd u cer s a nd me a s ur i n g t he
tr a n si t t i me t ha t i t ta ke s fo r so u nd to tr a ve l
b et we e n t he t wo tr a n sd u cer s. T he d i f f er e nc e i n
th e t r a n si t t i me mea s ur e d is d ir ect l y a nd e xac tl y
r ela ted to t h e ve lo ci t y o f t he liq u id i n t he p ip e .

T he tr a nsd u cer s c a n b e mo u n ted i n t hr ee V-method


me t ho d s, Z - met ho d , V - me t ho d a nd W - me t ho d ,
d ep e nd i n g o n p ip e s ize . Z - me t ho d i s u sed fo r
lar ge p ip e. T he t wo tr a n sd uce r s ar e i n sta ll ed o n
o p p o si te s id e s o f t he p ip e. V - me t ho d i s u sed fo r
med i u m s ize p ip e. T he t wo tr a nsd u cer s ar e o n
th e sa me s id e, t h u s, t he so u nd t r a n s ver se s t he
f lo w t wi ce . W - me t ho d i s u s ua ll y u s ed fo r s ma ll
p ip e. T h e so u nd tr a n s ve r se s a cr o ss t he flo w fo ur W-method
ti me s.
Optional Transducers:
Type HS
Handheld small size transducer (magnetic with mounting rack and handle)
Dim 7.9”x1”x1” (200x25x25mm3), handle length 3.9” (100mm)
For pipe size: 1” ~ 4” (DN25 ~ DN100mm)
Temperature: 32˚ F ~ 176˚ F (0˚C ~ 8 0˚C)

Type S1HT
Small size, high temperature transducer
Pipe size: 1” ~ 4” (DN25 ~ DN100mm)
Temperature: 32 ˚ F ~ 312˚ F (0˚C ~ 155˚C)
Type HM
Medium size transducer (magnetic with mounting rack)
Dim 11”x1.6” x1.6” (280x40x40mm3) for each
Pipe size: 2” ~ 28” (DN50 ~ DN700mm)
Temperature: 32˚ F ~ 176˚ F (0˚C ~ 8 0˚C)

Type M1
Standard medium size transducer (magnetic with clamp-on fixture)
Dim 2.4”x1.8” x1.8” (60x45x45mm3)
Pipe size: 2” ~ 28” (DN50 ~ DN700mm)
Temperature: 32˚ F ~ 176˚ F (0˚C ~ 8 0˚C)
Type M1HT
Medium size, high temperature transducer
Pipe size: 2” ~ 28” (DN50 ~ DN700mm)
Temperature: 32 ˚ F ~ 312˚ F (0˚C ~ 155˚C)
Type L1
Large size transducer
Dim 3.1”x2.7” x2.2” (80x70x55mm3)
Pipe size: 11” ~ 240” (DN300 ~ DN6,000mm)
Temperature: 32˚ F ~ 176˚ F (0˚C ~ 8 0˚C)

Model Selection:
S T U F - 2 0 0 H - - -
HS – Handheld type for pipe 1” ~ 4” *
S1HT – High-temp type for pipe 1” ~ 4”*
HM – Mounting-rail type for pipe 2” – 28”
M1 – Standard type for pipe 2” – 28”
M1HT – High-temp type for pipe 2” ~ 28” PC Software RS232-USB Adapter
L1 – Standard type for pipe 11” – 240” 0 – No (Default) 0 – No (Default)
1 – Yes 1 – Yes
*Note:
For pipes smaller than 2” (DN50), and the pipe is metal or
copper, please inform us when place the order.

Example:
STUF-200H-HM1-1-1: handheld ultrasonic flowmeter with mounting-rail type transducer for pipes from 2” to
28”, PC software and 232-USB adapter.

SHENITECH, LLC
10-214 Tower Office Park, Woburn, MA 01801, USA
Tel. +1781 932 0900 or +1 888 738 0188, Fax +1 978 418 9170
Email: sales@shenitech.com, Website: www.shenitech.com