Information Low Performance Mid Performance High Performance

General Run lengths No run length information. Current run length from Current run length from
provided data point. provided data point. Past
feed stock type and
temperature trends during
current run length.

Furnace Geometries No furnace information. Main furnace box width, Full schematics with all
depth, and height. furnace section widths,
depths, and heights.

Materials No material information. No material information. Furnace box refractory


material lists.
Fuel/Burners No fuel or burner Fuel gas and oxidant Fuel gas and oxidant
information. temperature, pressure, temperature, pressure,
composition and flow rates. composition and flow rates.
Furnace outlet exhaust Exhaust excess O2 reading.
temperature and pressure. Furnace outlet exhaust
temperature and pressure.
Exhaust excess O2 reading.
Tube skin temperature
readings.

Tube Coils Feeds H/C ratio and density (or H/C ratio, PIONA wt%s, Full component group
PIONA wt %s and density). molecular weight, density, analysis up to C9+, which is
and distillation curve. then grouped (e.g. C10-C12
Paraffins, C10-12 Aromatics,
C13+ Aromatics, etc).

Products Density and PIONA wt %s. Partial component analysis Full component analysis up
(with process and grouped heavier to C9+, which is then family
sampling point fractions. grouped (e.g. C10-C12
location Paraffins, C10-12 Aromatics,
provided) C13+ Aromatics, etc).

Conditions Inlet temperature and any Inlet temperature, pressure Inlet temperature, pressure
flow rate measurement. and mass flow rate and mass flow rate
Outlet temperature and measurement. Outlet measurement. Outlet
pressure. temperature and pressure. temperature and pressure.
Intermediate tube
temperatures.

Geometries Tube length, diameter, and Tube length, diameter, Tube length, diameter,
(information thickness. thickness and material type. thickness and material type.
provided for Additional information on
each differing any coatings or additional
tube section) inhibition treatments.
Layout No layout information. Layout direction, pitch, and Layout direction, pitch, and
number of passes. number of passes. Burner
location with respect to
tube bundles also provided.