Control Switches
CG, CH and CHR type up to 25 A
Kraus & Naimer
The development of the Blue Line rotary switch, contactor and motor
starter product ranges is based on more than hundred years
experience by Kraus & Naimer in the design and manufacture of
electrical switchgear. Kraus & Naimer pioneered the introduction of
the cam operated rotary switch and continues to be recognized as
the world leader in that product field.
BLUE LINE
Blue Line products are protected by numerous patents through-
out the industrial world. They are built to national and international
standards and designed to withstand adverse temperatures and
climates.
Blue Line products are accepted and universally recognized for their
quality and workmanship. They are supported by a worldwide sales
and service organization.
WORLDWIDE SYMBOL
FOR QUALITY SWITCHGEAR
Disconnectors and Main Switches acc. to IEC 60947-3 see Catalog 500
Contents Page
Construction Data 4
Dimensions and
Nominal Ratings 5
How to order 6, 7
Types of Mounting
Panel Mounting 26-29
Base Mounting 30, 31
Handles 34
Dimensions
Panel Mounting 40-43
Base Mounting 44, 45
Overall Switch Lengths 45, 46
Cam switches of the CG, CH and CHR-series are designed to install the switches closely, side by side, or to mount them
for universal application and may ideally be used for control directly at the cable trays. The contact terminal numbers are
switches, instrumentation switches and motor control switches. easy to read, even if the switch is installed.
Different contact designs, contact materials and terminals
allow the use as well as in electronic circuitry and in aggressi- The captive plus-minus screws of the CH and CHR-series
ve environments in accordance with IEC 60947-3, EN 60947- are located about 90° apart from the terminal direction. This
3, VDE 0660 part 107, UL and cUL (cUR). allows for connecting wires without any interference with the
terminal screws.
The stage is the basis for all switches and can be supplied
with a maximum of 2 contacts. All switches of this series are For connection with ring type terminals the CHR-series were
supplied with open terminals which are accessible while the designed. The switches are supplied with large open termi-
switch is installed. The terminals are protected against accidental nals. This allows for connection without removing the screws.
finger contact according to EN 50274, VDE 0660 part 514 and
BGV A3. Captive plus-minus terminal screws and integrated
screwdriver guides facilitate wiring. Due to the particular
arrangement of the terminals of the CG switches, it is possible
4
Nominal Ratings
Switch Size Type According to IEC 60947-3, EN 60947-3, VDE 0660 part 107
Operational Thermal Motor Rating
Voltage1 Current 3 x 380 V-440 V
Ue Iu/Ith AC-23A AC-3
V A kW kW
S00 30
1.18˝sq
CG4 440 10 3 2,2
CG4-1 440 10 3 2,2
CGD4-1 440 5 - -
CG6 690 20 7,5 5,5
CH6 690 20 7,5 5,5
CHR6 690 20 7,5 5,5
S0 48
1.89˝sq
< back to table of contents >
S1 64
2.52˝sq
CH10B 690 20 7,5 5,5
CH16B 690 25 11 7,5
CHR10B 690 20 7,5 5,5
CHR16B 690 25 11 7,5
The type of switch required may be The code numbers for standard switches Types of mounting are shown on pages
easily selected by referring to the table shown on pages 8-25 indicate the switch 26-31. Catalog 101 describes enclosu-
on page 5 which shows the thermal function, escutcheon plate, handle and res and optional extras.
current, power rating and dimensions any optional extras.
of each switch. For further technical Specify the mounting code to indicate
details, refer to pages 36-38. Variations Additional coding to modify type and required mounting.
of contacts and terminals are shown color of handle and escutcheon plate is
below. explained below.
CH10 A202-600 VE
Type of Switch
Example: Coding for switch type CH10 with latching mechanism size S1 is CH10B.
Modification of Switches
The part number for switch function and options may be modified in cases where items are required other than standard. The
modification may involve the escutcheon plate inscription, color combination of escutcheon plate and handle, type of escutcheon
plate and handle or the optional extra.
1
Technical data on request. 2Connection Diagrams on request.
6
How to order
Modification of Switches
The standard switch consists of a transparent escutcheon plate with brushed aluminum backing and black inscription. The
escutcheon plate frame is black as well as the handle. Page 6 shows further color combinations of escutcheon plate and handle
which are available. The appropriate dash number must be substituted in the switch function coding to specify other color
combinations as required.
Example: The complete coding for switch type CG8 with a 3 pole ON/OFF switch function, black handle and black escutcheon
plate frame with brushed aluminum backing and black inscription which reads 0-1 is as follows: CH10 A202-600 E.
The following is a list of special programs for escutcheon plate and handle combinations. They may be obtained by specifying
any one of the following two (2) digit dash numbers as a part of the overall dash number. It is still necessary to prefix these two
digit numbers with the first digit which represents the color combination desired.
Special programs for escutcheon plate and handle combinations
-000 = without escutcheon plate, without handle - .09 = with P-handle
- .01 = without escutcheon plate - .10 = escutcheon plate frame and fixation ring only
- .02 = without handle (if using switches with single hole mounting: - .16)
- .03 = with square escutcheon plate without lettering - .11 = without escutcheon plate, but with handle
- .04 = with rectangular escutcheon plate without lettering bearing plate
- .05 = with square escutcheon plate without lettering and - .12 = with yellow escutcheon plate backing and
without handle red handle
- .06 = with rectangular escutcheon plate without lettering - .14 = with B-handle
and without handle - .16 = escutcheon plate frame and fixation ring only
- .07 = standard escutcheon plate, without lettering if using switches with single hole mounting
on rectangular section - .17 = standard escutcheon plate and rectangular add-on
- .08 = with F-handle escutcheon plate if using switches with single
hole mounting FT2
< back to table of contents >
Example: The complete coding for switch type CH10 with a 3 pole ON/OFF switch function with black face plate frame, square
face plate without lettering, brushed aluminum plate backing and black handle reads as follows: CH10 A202-603 E.
Switch Size
CG, CH and CHR switches are available in sizes S00, S0 and S1. These size codes indicate the dimension of the mounting, the
escutcheon plate and the handle, as well as the size of optional devices and enclosures. Page 5 lists these sizes and the
various switch types they include.
CH16
300 60
240 120 R K S
210
180
150 A
For technical reasons, it may not be possible to
EXTRAS
OPTIONAL
MOUNTING
H x x x
x x x x
A x x x
DATE
FIRM
:
:
SIGNED
:
7
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
ON/OFF Switches with 60° Switching
1 pole I I I I A200-600 1
2 pole I I I I A201-600 1
3 pole I I I I A202-600 2
3 pole with red handle I I I I A202-626 2
4 pole
F070
I I I I A203-600 2
4 pole 1 pole preclose 6° 1 I I I I WAA653 2
5 pole I I I I WAA341 3
6 pole I I I I A342-600 3
7 pole I I I I A343-600 4
8 pole I I I I A344-600 4
8 pole 2 pole preclose 6° 1 I I I I WAA654 4
9 pole I I I WAA345 5
10 pole I I I A346-600 5
11 pole I I K WAA347 6
12 pole I I K A348-600 6
1 pole I I I I A200-620 1
2 pole I I I I A201-620 1
3 pole I I I I A202-620 2
4 pole I I I I A203-620 2
F088
I I I I
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
ON/OFF Switches with 90° Switching
F062
I I I I WAA208 2
F206
2
3 pole for foot operation A WAA386 2
1 pole I WAA100 1
2 pole I WAA101 1
3 pole I WAA102 2 1-4 pole
4 pole F169 I WAA103 2
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram 2
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Double-throw Switches without „OFF“ 60° Switching
1 pole I I I I A220-600 1
2 pole I I I I A221-600 2
3 pole I I I I A222-600 3
4 pole F072 I I I I A223-600 4
4 pole 1 pole preclose 6° 1 I I I I WAA673 4 1-4 pole 4 pole 1 pole preclose 6°
5 pole I I I A369-600 5
6 pole I I I A370-600 6
7 pole I I I A371-600 7
8 pole I I I A372-600 8
8 pole 2 pole preclose 6° 1 I I I WAA972 8 5 pole
9 pole I I WAA373 9
10 pole I I WAA374 10
11 pole I I WAA375 11
12 pole I I WAA376 12
6 and 7 pole
8 and 9 pole
10 and 11 pole
12 pole
1 pole I I I I A720-600 1
2 pole I I I I A721-600 2 1-4 pole
3 pole I I I I A722-600 3
4 pole F072 I I I I A723-600 4
4 pole 1 pole preclose 6° 1 I I I I WAA973 4 4 pole 1 pole
preclose 6°
1 pole I WAA120 1
2 pole I WAA121 2 1-4 pole
3 pole I WAA122 3
4 pole F026 I WAA123 4
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram 2
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Double-throw Switches with Center „OFF“ 60° Switching
1 pole I I I I A210-600 1
2 pole I I I I A211-600 2
3 pole I I I I A212-600 3
4 pole F071 I I I I A213-600 4
4 pole 1 pole preclose 6° 1 I I I I WAA913 4
5 pole I I I A361-600 5
6 pole I I I A362-600 6
7 pole I I I WAA363 7
8 pole I I K WAA364 8 1-4 pole
8 pole 2 pole preclose 6° 1 I I K WAA664 8
1 pole I I I I A210-620 1
2 pole I I I I A211-620 2
3 pole I I I I A212-620 3 4 pole 1 pole preclose 6°
4 pole F090 I I I I A213-620 4
4 pole 1 pole preclose 6° 1 I I I I WAA913 4
5 pole I I I A361-620 5
6 pole I I I A362-620 6
7 pole I I K WAA363 7 5 pole
8 pole I I K WAA364 8
8 pole 2 pole preclose 6° 1 I I K WAA664 8
< back to table of contents >
1 pole I I I I A210-621 1
2 pole I I I I A211-621 2 6 and 7 pole
3 pole
F085
I I I I A212-621 3
1 pole I I I I A210-622 1
2 pole I I I I A211-622 2
3 pole I I I I A212-622 3 8 pole
F085-PRL
1 pole I I I I A210-623 1
2 pole I I I I A211-623 2
3 pole
F260
I I I I A212-623 3
8 pole 2 pole preclose 6°
1 pole I I I I A210-624 1
2 pole I I I I A211-624 2
3 pole I I I I A212-624 3
4 pole F732 I I I I A213-624 4
4 pole 1 pole preclose 6° 1 I I I I WAA913 4
1 pole I I I I A218-600 1
2 pole I I I I A219-600 2
3 pole I I I I WAA299 3
4 pole 1 pole preclose 6° 1 F057 I I I I WAA294 4
1-4 pole
1 pole I I I I A218-620 1
2 pole I I I I A219-620 2
3 pole I I I I WAA299 3
4 pole 1 pole preclose 6° 1 F064 I I I I WAA294 4
1 pole I I I I A710-600 1
2 pole I I I I A711-600 2 1-4 pole
3 pole I I I I A712-600 3
4 pole F071 I I I I A713-600 4
4 pole 1 pole preclose 6° 1 I I I I WAA963 4 4 pole 1 pole
preclose 6°
F025
1
For use in a three phase four-wire system with switched neutral. 2Connection diagrams for CHR switches on request.
11
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram 1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Double-throw Switches with Spring Return to Center
1 pole I I P P A214-620 1
2 pole I P P A215-620 2 1-3 pole
3 pole
F034
I P P A216-620 3
1 pole I I I I A320-621 1
2 pole I I I I A321-621 2 1-3 pole
3 pole
F341
I I I A322-621 3
1 pole I I I I A310-620 1
2 pole I I I I A312-620 2
3 pole I I I I WAA314 3
F098 3 pole
1 pole I I I I A311-620 2
2 pole I I I I WAA313 3
3 pole I I I WAA315 5
F040 3 pole
1 3
1 pole 2 Gang I I I I WAA330 1
2 pole Series switching I I I I WAA331 2 L1
N
R
O A B
3 pole Switching sequence: I I I I WAA332 3 2 6 5 7
0, A, B, A+B F001 1 pole 2 pole
1 pole I I I I WAA330 1
2 pole I I I I WAA331 2
3 pole I I I I WAA332 3
F040 3 pole
F040
1
Connection diagrams for CHR switches on request.
12
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch.
Function Code Stages Connection Diagram
Plate CG4- CG6- CH11 CH10B-
CGD4-1 CHR6 CH12 CHR16B
Dimensions p. 46
Coding Switches/Binary Code
0-7 I I A540-600 2
360° rotation
F322
0 - 7 complement I I WAA541 2
360° rotation
F322
0 - 7 + complement I I WAA542 3
360° rotation
F322
< back to table of contents >
0-9 I I A550-600 2
F007
0 - 9 complement I I WAA551 2
F007
0 - 9 + complement I I WAA552 4
F007
0 - 11 I I WAA543 2
360° rotation
F009
0 - 11 + complement I I WAA545 4
360° rotation
F009
13
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Multi-step Switches without „OFF“
3 pole
4 and 5 pole
6 pole
4-6 pole
3 pole
F010
F011
F012
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Multi-step Switches without „OFF“ with electrically isolated contacts
F076
1 pole
2 pole I I I I A750-600 3
2 pole
F077
1 pole
2 pole I I I I A751-600 4
< back to table of contents >
2 pole
1 pole I I I I A241-620 2
2 pole I I I I A261-620 3
3 pole I I I A281-620 5 3 pole
4 pole F115 I I I WAA481 6
5 pole I I I WAA487 8
1 pole I I I I A241-621 2
2 pole I I I I A261-621 3 4 pole
F289
5 pole
1
Connection diagrams for CHR switches on request.
15
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Multi-step Switches with „OFF“
1 pole I I I I A242-620 2
2 pole I I I I WAA262 4 1-4 pole
3 pole I I I WAA282 6
4 pole F041 I I I WAA482 8
1 pole I I I I A243-620 3
2 pole I I I WAA263 5 1-3 pole
3 pole F042
I I I WAA283 8
1 pole I I I I A244-620 3
2 pole I I I WAA264 6 1-3 pole
3 pole F043
I I WAA284 9
1 pole I I I I WAA245 4
2 pole I I I WAA265 7 1 pole 2 pole
F044
F006
1 pole I I I I WAA246 4
F045
F007
1 pole I I I WAA247 5
F046
F008
1 pole I I I WAA248 5
F047
1 pole I I WAA249 6
1 pole 360° rotation I WAA649 6
F048
1
Connection diagrams for CHR switches on request.
16
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Voltmeter Switches without „OFF“
F792
I I I I A023-620 2
F793
F795
2 pole I I S S WAA002 1
360° rotation
F170-PRL
F775
I I S S A004-620 2
F776
I I S S A004-621 2
F408-PRL
I I I I A004-622 2
F777
I I I I A004-623 2
F409-PRL
I I I I A004-624 2
F778
I I S S WAA011 2
F212-PRL
1
Connection diagrams for CHR switches on request.
17
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Voltmeter Switches with „OFF“
F779
I I S S WAA005 2
F780
I I S S WAA005 2
F411-PRL
I I I I WAA005 2
F412-PRL
I I I I WAA005 2
I I S S A007-620 3
F783
I I S S A007-621 3
F414-PRL
I I I I A007-622 3
F784
I I I I A007-623 3
F415-PRL
I I I I A007-624 3
F785
I I S S WAA008 4
F787
I I S S WAA008 4
F418-PRL
I I I I WAA008 4
F788
1
Connection diagrams for CHR switches on request.
18
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Voltmeter Switches with „OFF“
F790
I I S S WAA010 3
F419-PRL
I I I I WAA010 3
F791
Ammeter Switches
I I I I
< back to table of contents >
F208
I I S S WAA046 1
F340-PRL
F181-PRL
I I S S A017-620 3
F719
I I S S A048-620 3
F066
I I I I A048-621 3
F186
I I I I A048-622 3
F318-PRL
I I S S A048-623 3
F172-PRL
1
Connection diagrams for CHR switches on request.
19
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Ammeter Switches
F172-PRL
I I S S A021-620 2
F066
F327-PRL
2 pole I I I I WAA037 3
2 current transformers
F064
I I S S WAA037 3
F320-PRL
2 pole I S S WAA019 5
3 current transformers
F181-PRL
I S S WAA019 5
F719
I I I A038-600 5
F059
I S S A038-620 5
F172-PRL
I I I A038-621 5
F318-PRL
2 pole I I I WAA039 6
4 current transformers
F060
I S S WAA039 6
F327-PRL
1
Connection diagrams for CHR switches on request.
20
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Volt-ammeter Switches
F077
F174-PRL
Control Switches
F022
F023
I I I I A178-620 1
F130
I I I I WAA177 2
F132
1
Connection diagrams for CHR switches on request.
21
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Control Switches
F132
F144-PRL
I I I I WAA179 2
F034
F143-PRL
1
Advise the indicator device, described in Catalog 101, page 9. 2incl. slip clutch
22
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Motor Reversing Switches
2 pole I I I I A400-600 2
F071
I I I I A400-620 2
F093
I I I I A400-621 2
F090
3 pole I I I I A401-600 3
F071
I I I I A401-620 3
F093
< back to table of contents >
I I I I A401-621 3
F090
F034
2 speed I I I I WAA451 3
2 winding
0-A-B s or d
F073
I I I I WAA451 3
F094
3 speed I I I WAA457 6
2 winding
0-Ad-B s -A ss
F109
I I I WAA457 6
F115
1
Connection diagrams for CHR switches on request.
23
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Motor Control Switches
F073
I I I I A440-620 4
F094
I I I I A441-620 4
I I I A442-620 6
F113
I I I WAA444 5
F094
I I WAA468 102
F317
1
Connection diagrams for CHR switches on request. 2incl. slip clutch
24
Switch Function and Configuration CG, CH, CHR Switches
Type/Handle
Escutch. CG8
Function Code Stages Connection Diagram1
Plate CG4- CG6- CH10- CH10B-
CGD4-1 CHR6 CHR16 CHR16B
Dimensions p. 46
Star-delta Switches
OFF-star-delta I I I I A410-600 4
F080
I I I I A410-620 4
F315
Reversing I I I WAA413 5
F112
F080
contactors
F061
F119 Split-phase
I I I I A425-620 2 START FLD
F130
F117
1
Connection diagrams for CHR switches on request.
25
Mounting CG, CH, CHR Switches
Panel mounting
EF
Two hole panel mounting, EF-V
Protection IP 66/67/69k
26
Mounting CG, CH, CHR Switches
CG4-
Two Hole Panel Mounting or Mosaic Mounting Code CHR6
Mosaic mounting
27
Mounting CG, CH, CHR Switches
CG8- CH10B-
Two or Four Hole Panel Mounting Code CHR16 CHR16B
28
Mounting CG, CH, CHR Switches
FS2 16/22
With square escutcheon plate, FS2-V 16/22
Protection IP 66/67/69k FT2 22
FT2-V 22
FT4 22/30
FT4-V 22/30
29
Mounting CG, CH, CHR Switches
Base mounting
30
Mounting CG, CH, CHR Switches
CG4- CG8-
Base Mounting Code CGD4-1 CHR16
Base mounting
31
Escutcheon Plates
Square and rectangular escutcheon plates are available for each size of switch. The
escutcheon plate consists of a frame and a faceplate having the switch positions
which is than embossed with hot-foil backing. The escutcheon plate frame is an
essential part of the switch and serves as a bearing surface for the handle. If the
switch is to be mounted without an escutcheon plate we would recommend for size S1
the handle bearing plate T100-04.
30° switching
F022 F141 F158 F703 F023 F137 F142 F159 F701 F704 F152 F709 F026 F035 F153 F169 F024 F143
F160 F221 F222 F224 F025 F034 F036 F037 F038 F039 F139 F144 F147 F149 F150 F151 F219 F258
F259 F273 F280 F329 F384 F708 F053 F161 F297 F298 F306 F307 F001 F040 F052 F229 F355 F018
F712 F002 F021 F033 F041 F055 F305 F319 F054 F003 F042 F138 F255 F299 F308 F353 F350 F351
f
1 OFF 1
2 2
3 3
F004 F014 F017 F020 F027 F028 F031 F032 F043 F049 F135 F156 F157 F162 F167 F168 F187 F189
F303 F304 F336 F337 F347 F348 F710 F713 F714 F734 F005 F044 F136 F140 F702 F006 F010 F045
F015 F050 F007 F011 F046 F008 F012 F047 F016 F051 F009 F013 F048 F748
45° switching
F747 F295 F742 F743 F215 F216 F738 F744 F746 F792 F793 F107 F109 F114 F115 F212 F213 F214
F217 F267 F289 F330 F375 F376 F383 F408 F409 F410 F411 F412 F413 F426 F427 F430 F729 F752
F775 F776 F777 F778 F779 F780 F781 F796 F797 F798 F105 F108 F112 F113 F117 F118 F293 F429
F739 F741 F419 F789 F790 F791 F794 F795 F110 F106 F116 F294 F317 F414 F415 F416 F417 F418
F782 F783 F784 F785 F786 F787 F788 F799 F111 F210 F211 F284 F285 F296 F322 F727 F740
32
Escutcheon Plates
60° switching
F070 F087 F088 F089 F133 F197 F198 F232 F243 F247 F263 F268 F310 F311 F323 F328 F352 F367
F379 F380 F470 F754 F072 F163 F164 F192 F193 F196 F230 F231 F234 F244 F257 F262 F264 F282
F288 F291 F313 F382 F441 F705 F721 F722 F750 F757 F758 F075 F076 F098 F220 F223 F356 F357
F377 F723 F071 F073 F080 F081 F085 F086 F090 F091 F092 F093 F094 F104 F194 F235 F237 F239
F240 F241 F249 F260 F269 F274 F281 F290 F292 F312 F314 F315 F316 F324 F331 F344 F354 F358
F359 F364 F370 F371 F373 F381 F385 F442 F444 F469 F732 F735 F759 F077 F100 F101 F102 F309
< back to table of contents >
F342 F343 F361 F362 F363 F365 F366 F078 F191 F325 F326 F720 F074 F082 F096 F097 F195 F724
F256 F079 F083 F084 F095 F099 F185 F190 F199 F233 F236 F238 F242 F283 F725 F730 F731 F736
F737
90° switching
f ON f 1
OFF 0
F056 F063 F068 F134 F201 F251 F252 F346 F456 F058 F065 F069 F177 F178 F182 F208 F253 F254
F340 F360 F378 F458 F443 F700 F743 F057 F061 F064 F067 F171 F181 F205 F207 F209 F320 F349
F437 F445 F715 F719 F059 F060 F062 F066 F170 F172 F173 F174 F175 F176 F179 F180 F186 F188
F202 F204 F206 F250 F265 F266 F286 F318 F327 F338 F339 F425 F716 F717 F718 F726 F733 F751
F755 F756
Miscellaneous
F119 F130 F122 F126 F125 F129 F225 F248 F246 F261 F341 F345 F287 F123 F127 F145 F146 F148
F706 F707 F245 F120 F124 F128 F131 F121 F132 F749 F990 F991 F801 F802 F803 F804
F805 F806 F807 F808 F809 F810 F811 F812 F813 F814 F815 F816 F817 F818 F819 F820 F821 F822
INTERRUPTEUR PRINCIPAL INTERRUTTORE GENERALE INTERRUPTOR PRINCIPAL
OUVERTURE EN POSITION 0 APRIRE SOLO CON MANIGLIA SU 0 ABRIR ARMARIO SOLO EN POS. ’’0’’
1 2 3
F823 F824 F825 F826 F827 F828 F829 F830 F831 F832 F833 F834 F835 F837 F838 F839 F840 F841
1
INTERRUPTEUR PRINCIPAL, OUVERTURE EN POSITION 0 2INTERRUTTORE GENERALE, APRIRE SOLO CON MANIGLIA SU 0
3
INTERRUPTOR PRINCIPAL, ABRIR ARMARIO SOLO EN POS. ’’0’’ 33
Handles
S00 S0, S1
S0 S1
S0 S1
34
International Standards and Approvals
CH6 CHR6
Mark or CH10 CHR10
Country Authority CG4-1 CH11 CH16 CHR11 CHR16
Standard CG4 CGD4-1
CG6 CG8 CH12 CH16B CHR12 CHR16B
CH10B CHR10B
1
USA Underwriters
Laboratories
2
3
6
Canada Canadian Standards
Association
CG4-1
C
3
Switzerland Schweizerischer
Elektrotechnischer + + + + + + + +
Verein
Denmark Danmarks Elektriske
Materiellkontrol + + + + + + + +
< back to table of contents >
Austria Österreichischer
Verband für + + + + + + + +
Elektrotechnik
Federal Verband Deutscher VDE 0660 4
Republic Elektrotechniker + + + + + + + +
of Germany
Great British Standards BS
Britain Institution EN 60947 4 + + + + + + + +
35
Technical Data CG, CH, CHR Switches
CH6 CHR6
Selection Data
CG4 CG6 CH10 CHR10 CH16 CHR16
CG4-1 CG8 CH10B CHR10B CH16B CHR16B
Rated Insulation Voltage Ue IEC 60947-3, EN 60947-31
VDE 0660 part 1071 V
440 690 690 690 690 690
SEV max. V
400 690 – – – –
UL/Canada2 V
300 300 600 600 600 600
CEE 24 V
380 380 – – – –
min. voltage V on request
Power loss per contact at Iu W 0,4/0,7 0,8 1,4 1,4 2,3 2,3
Resistance to vibration on request
Resistance to shock min. 5 g, 30 ms
Min. Ambient Temperature of Stages -25 °C (valid only without optional extra)
Max. Ambient Temperature open at 100 % Iu/Ith 55 °C during 24 hours with peaks up to 60 °C
of Stages 5, 7 enclosed at 100 % Ithe 35 °C during 24 hours with peaks up to 40 °C
1
Valid for lines with grounded common neutral termination, overvoltage category III, pollution degree 3. Values for other supply systems on request. 2International Stan-
3 4 5
dards and Approvals, refer to page 35. Valid only for max. 4 simultaneously opening contacts. Valid for CG4 only. For electromagnetic optional extras see additional data
36 6 7
in Catalog 101. Values for switches with spring return on request. Storage temperature: -40 °C to 85 °C (in case of temperature below -5 °C no shock load permissible).
Technical Data CG, CH, CHR Switches
CH6 CHR6
Selection Data
CG4 CG6 CH10 CHR10 CH16 CHR16
CG4-1 CG8 CH10B CHR10B CH16B CHR16B
Rated Utilization Category IEC 60947-3, EN 60947-3
VDE 0660 part 107
AC-2 Slip ring motor starting, 3 phase 220 V-240 V
2,5 4 4 4 5,5 5,5
reversing and plugging, 3 pole 380 V-440 V kW
4,5 7,5 7,5 7,5 11 11
star-delta starting 500 V
– 10 10 10 15 15
(CG4-CHR10B) 660 V-690 V
– 10 10 10 13 13
Direct-on-line starting,
AC-3 3 phase 220 V-240 V
1,5 3 3 3 4 4
star-delta starting 3 pole 380 V-440 V kW
2,2 5,5 5,5 5,5 7,5 7,5
(CH16-CHR16B) 500 V
– 5,5 5,5 5,5 7,5 7,5
660 V-690 V
– 5,5 5,5 5,5 7,5 7,5
AC-4
Direct-on-line starting, 3 phase 220 V-240 V
0,37 0,55 0,55 0,55 1,5 1,5
reversing, plugging and 3 pole 380 V-440 V kW
0,55 1,5 1,5 1,5 3 3
inching 500 V
– 1,5 1,5 1,5 3 3
660 V-690 V
– 1,5 1,5 1,5 3 3
< back to table of contents >
AC-23A Frequent switching of 3 phase 220 V-240 V
1,8 3,7 3,7 3,7 5,5 5,5
motors or other high 3 pole 380 V-440 V kW
3 7,5 7,5 7,5 11 11
inductive loads 500 V
– 7,5 7,5 7,5 11 11
660 V-690 V
– 7,5 7,5 7,5 11 11
Ratings UL/Canada
Standard motor load 3 phase 110 V-120 V
0,75 1,5 1,5 1,5 2 2
DOL-Rating 3 pole 220 V-240 V HP
1 1 3 3 5 5
(similar AC-3) 440 V-600 V
– – 5 5 10 10
1 phase 110 V-120 V
0,33 0,5 0,5 0,5 1 1
2 pole 220 V-240 V HP
0,75 1 1 1 2 2
277 V
0,75 1 2 2 3 3
440 V-600 V
– – 2 2 5 5
1 phase 110 V-120 V
– 0,17 0,17 0,17 0,33 0,33
2 pole 220 V-240 V HP
– 0,5 0,5 0,5 0,75 0,75
277 V
– 0,5 0,6 0,6 1 1
440 V-600 V
– – 1,5 1,5 2 2
Flexible wire (sleeving in accordance with DIN 46228) mm2
2x1,5(1) 2x2,5(2,5) 2x2,5(2,5) 2x2,5(2,5)
Flexible AWG wires (without sleeve) AWG
2x16 2x14 2x12 2x12
37
Technical Data CG, CH, CHR Switches
Selection Data
CGD4-1 CH11 CHR11 CH12 CHR12
min. voltage V 14 14 14 6 6
North America A 5 6 6 6 6
Flexible wire (sleeving in accordance with DIN 46228) mm2 2x1,5(1) 2x2,5(2,5) 2x2,5(2,5)
Flexible AWG wires (without sleeve) AWG 2x16 2x12 2x12
Max. Ambient Temperature of Stages -25 °C (valid only without optional extra)
Max. Ambient Temperature open at 100 % Iu/Ith 55 °C during 24 hours with peaks up to 60 °C
of Stages 3, 6 enclosed at 100 % Ithe 35 °C during 24 hours with peaks up to 40 °C
1
Valid for lines with grounded common neutral termination, overvoltage category III, pollution degree 3. Values for other supply systems on request.
2
max. 300 V. 3For electromagnetic optional extras see additional data in Catalog 101. 4Values for lower voltages on request. 5Values for switches
38 6
with spring return on request. Storage temperature: -40 °C to 85 °C (in case of temperature below -5 °C no shock load permissible).
Tightening torque of screws
39
mm
Dimensions inch
E E
for E-V
CG4-CGD4-1
CH6/CHR6
E-V
for
CG6 CG4
CG4-1 CH6 CH10-
CH10B-
E-V CGD4-1
CG6 CG8 CHR6 CHR16
CHR16B
for
30 30 48 30 48 64
CG4-CGD4-1 A 1.18 1.18 1.89 1.18 1.89 2.52
CH6/CHR6 B 28 38 38 46 46 56
1.10 1.50 1.50 1.81 1.81 2.20
E 4 4 4 4 4 4
for C .16 .16 .16 .16 .16 .16
CG6 3,2 3,2 5 3,2 5 5
D1 .13 .13 .20 .13 .20 .20
8-11 8-11 8-19 8-19 8-19 10-22
D2 .31-.43 .31-.43 .31-.75 .31-.75 .31-.75 .39-.87
- - 36 - 36 48
E - - 1.42 - 1.42 1.89
EF-V A 30 30 48 30 48 64
1.18 1.18 1.89 1.18 1.89 2.52
for 28 38 38 46 46 56
CG4-CGD4-1 B 1.10 1.50 1.50 1.81 1.81 2.20
4 4 4 4 4 4
CH6/CHR6 C .16 .16 .16 .16 .16 .16
EF D1 3,2 3,2 5 3,2 5 5
.13 .13 .20 .13 .20 .20
for
8-11 8-11 15-19 8-11 15-19 19-22
CG6 D2 .31-.43 .31-.43 .59-.75 .31-.43 .59-.75 .75-.87
- - 36 - 36 48
E - - 1.42 - 1.42 1.89
1 1 - 1 - -
M .04 .04 - .04 - -
E22
for
CG
E22-V
for
CH/CHR
E22-V
for CH10-
CG CG8 CHR16
E22
for A
48 48
1.89 1.89
CH/CHR 38 46
B 1.50 1.81
4 4
C .16 .16
5 5
D1 .20 .20
30 30
E 1.17 1.17
1
see page 46
40
mm
Dimensions inch
EG
EGF
CH10-
CG8 CHR16
64 64
A 2.52 2.52
38 46
B 1.50 1.81
4 4
C .16 .16
5 5
D1 .20 .20
10-22 10-22
EG D2 .39-.87 .39-.87
19-22 19-22
EGF D2 .75-.87 .75-.87
48 48
E 1.89 1.89
6,7 6,7
M .26 .26
< back to table of contents >
E9 for for
E91 CG4-CGD4-1 CG6
CH6/CHR6
E92
CG4
CG4-1 CH6
CGD4-1 CG6 CHR6
28 38 46
E93 B 1.10 1.50 1.81
E94
CG4
CG4-1
CGD4-1
CG6
CH6
CHR6 E9 E91 E92 E93 E94
6 6,35 - - -
D .24 .25 - - -
12 12,8 - - -
F .47 .50 - - -
15,4 17,4 32,5 28,5 32,5
G .61 .69 1.28 1.12 1.28
4,7 5,5 - - -
K .19 .22 - - -
- - - 4 -
M - - - .16 -
1
see page 46
41
mm
Dimensions inch
EC ED22
ED
EC1
ED1
EC EC EC1
ED22 ED ED22 ED ED1
48 64 48 64 64
A 1.89 2.52 1.89 2.52 2.52
74 68 74 68 74
B 2.91 2.68 2.91 2.68 2.91
- 4 - 4 4
EC/EC1 C - .16 - .16 .16
4 4 4 4 4
ED/ED1/ED22 C .16 .16 .16 .16 .16
5 5 5 5 5
D1 .20 .20 .20 .20 .20
- 10-19 - 10-22 10-22
EC/EC1 D2 - .39-.75 - .39-.87 .39-.87
11-15 19-22 11-15 19-22 19-22
ED/ED1/ED22 D2 .43-.59 .75-.87 .43-.59 .75-.87 .75-.87
- 48 - 48 48
E - 1.89 - 1.89 1.89
30 - 30 - -
F 1.17 - 1.17 - -
1,5 - 1,5 - -
ED/ED1/ED22 M .06 - .06 - -
74,3 - 74,3 - 72,7
Fluchten L 1 2.93 - 2.93 - 2.86
74,3 - 74,3 - 72,7
2 2.93 - 2.93 - 2.86
94,3 - 94,3 - 92,7
3 3.71 - 3.71 - 3.65
94,3 104 94,3 114,5 -
4 3.71 4.10 3.71 4.51 -
94,3 - - 127 -
5 3.71 - - 5.00 -
- - - 139,5 -
6 - - - 5.49 -
- - - 164,5 -
7 - - - 6.48 -
- - - 177 -
8 - - - 6.97 -
- - - - -
9 - - - - -
- - - - -
10 - - - - -
42
mm
Dimensions inch
KN1
KD1
KN2
48 48 64 64 64
A 1.89 1.89 A 2.52 2.52 2.52
38 46 38 46 56
B 1.50 1.81
B 1.50 1.81 2.20
4 4 4 4 4
C .16 .16
C .16 .16 .16
5 5 5 5 5
D1 .20 .20
D1 .20 .20 .20
8-15 8-15 10-22 10-22 10-22
D2 .31-.59 .31-.59
D2 .39-.87 .39-.87 .39-.87
< back to table of contents >
36 36 48 48 48
E 1.42 1.42
E 1.89 1.89 1.89
5,2 5,2 4,7 4,7 7
M .20 .20
M .19 .19 .28
1
see page 46
43
mm
Dimensions inch
Base Mounting
VE
VE-V
VF
VF-V
48 48 (64)
A2 1.89 1.89 (2.52)
38 46
B 1.50 1.81
10,5 10,5
C .41 .41
4,1 4,1
VF22 D1 .16 .16
VF22V D2 5 5
.20 .20
8-15 8-15
D3 .31-.59 .31-.59
36 36 (48)
E2 1.42 1.42 (1.89)
2,2 5,2
M .09 .20
2
Dimensions in ( ) for revertive mounting plate
VE1
CG4
CG4-1 CH10-
CGD4-1 CG8 CHR16
VE1E
30 48 48
A 1.18 1.89 1.89
28 38 46
B 1.10 1.50 1.81
- 10,5 10,5
C - .41 .41
- 5 5
D1 - .20 .20
- 8-15 8-15
D2 - .31-.59 .31-.59
VE1F
- 36 36
E - 1.42 1.42
35,5 48 48
F 1.40 1.89 1.89
60 60 60
G 2.36 2.36 2.36
12,5 20 20
M .49 .79 .79
1
see page 46
44
mm
Dimensions inch
VE2 VE21
for CG4-CGD4-1
1.77"
45
1.77"
45
61,2 S 17
2.41" .67"
35,5 S H
1.40"
VE3 VE21
for CG8-CHR16
1.77"
45
46 S 4,5
1.81" .18"
52,3 S 26,5
2.06" 1.04"
< back to table of contents >
VE4
A
.16"
4,1
46 S 4,5
1.81" .18"
Escutcheon plates for mounting E, EF, EG, EGF, KN1, KD1, KN2, EC, EC1, ED, ED1, VE, VE1, VF
Size A B C
30 39 5,5
S00 1.18 1.54 .22
48 59 6,7
S0 1.89 2.32 .26
64 78 7,4
S1 2.52 3.07 .29
45
mm
Dimensions inch
Additional Lengths
Quick connect terminations (plug 2,8 mm or 6,35 mm) for CH switches (page 6)
Length L
CH10 CHR10
CG4 CH11 CHR11
CG4-1 CH6 CH12 CHR12 CH10B
CHR10B
Stages CGD4-1
CG6 CG8 CHR6 CH16 CHR16 CH16B
CHR16B
46
< back to table of contents >
Notes:
The Range of “Blue Line” Switchgear
Technical literature covering the following products is available on request.
Catalog
Number
CL Switches 10 A-20 A
C, CA and CAD Switches 10 A-315 A and L Switches 350 A-2400 A
C, CA and CAD switches are designed for universal application. They are recommended for instrument, isolator,
double-throw and motor control. 100
L switches are designed for load and off-load applications. They are used to switch resistive or low inductive
loads.
We reserve the right to make technical and dimensional changes without prior notice.
48
SALES AND SERVICE ORGANIZATION
Great Britain
Kraus & Naimer Ltd.
115 London Road
NEWBURY/BERKSHIRE RG14 2AH
Tel: +44 1635 262626, Fax: 37807
sales-uk@krausnaimer.com
Contact us:
www.krausnaimer.com