Sie sind auf Seite 1von 1

MANUFACTURER OF WORLD CLASS DIRECT TENSION INDICATORS

1413 ROCKINGHAM RD. BELLOWS FALLS, VT 05101


TELEPHONE: 1-802-460-3100 FAX: 1-802-460-3104
PABT-012 REV. AO NADCAP CERT NO. 122996
VALID THROUGH JANUARY 31, 2010

CERTIFICATION OF TESTING
DIRECT TENSION INDICATOR WASHERS PER ASTM-F959-07 PAGE 1 OF 1

FOR CUSTOMER: PURCHASE ORDER#: INVOICE #:

TEST NUMBER: 07 - 09 - 2151 COMPRESSION LOAD IN POUNDS AT .015" GAP


* ACCEPTABLE COMPRESSION LOAD RANGE FOR THIS PRODUCT IS 80000 - 96000 POUNDS. *
DATE OF TEST: 07/06/09
90880 1) 11) 89890 20) 91540
PART NUMBER: ABT - 1184PL REV. AM 92690 2) 12) 90490 21) 92610
93220 3) 13) 91420 22) 92230
SIZE AND TYPE: 1-1/8" A490 PLAIN FINISH DTIS 93700 4) 14) 91590 23) 91580
92490 5) 15) 92750 24) 92740
LOT NUMBER: ABT1184PL09F - RD7 91750 6) 16) 91630 25) 92340
91390 7) 17) 91140 26) 91260
STEEL HEAT NUMBER: 0152354 92510 8) 18) 91900 27) 91410
90370 9) 19) 91710 28) 91560
DATE OF MANUFACTURE: 06/16/09 90770 10) 29) 90430
TESTING RESULTS RELATE ONLY TO THE ITEMS TESTED
SAMPLE SIZE PER ASTM F1470 - DETECTION
THIS DOCUMENT CERTIFIES THAT A SAMPLE OF THE ABOVE DESIGNATED PRODUCTION LOT OF DIRECT TENSION INDICATOR WASHERS
WAS TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM-F959-07 - STANDARD SPECIFICATION FOR COMPRESSIBLE-WASHER-TYPE
DIRECT TENSION INDICATORS FOR USE WITH STRUCTURAL FASTENERS AND FOUND TO CONFORM TO THAT SPECIFICATION.

CERTIFICATION TESTING WAS PERFORMED IN THE QUALITY ASSURANCE LABORATORY OF APPLIED BOLTING TECHNOLOGY PRODUCTS, INC.,
USING METHODS AND TEST EQUIPMENT DESIGNED PER THE REQUIREMENTS OF ASTM-F606-07 AND CALIBRATED WITH TRACEABILITY TO THE
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY.

GAUGE NUMBER: G - 026 UNCERTAINTY FACTOR - 25.17 LBS/F


CERTIFIED PER 07/06/09
CALIBRATION DATE: 04/09 HEADMARKING DATE
DIRECTOR
DIRECTOR- -QUALITY
QUALITYASSURANCE
ASSURANCE
APPLIED
APPLIEDBOLTING
BOLTINGTECHNOLOGY
TECHNOLOGY
NEXT DUE DATE: 07/09
THIS DOCUMENT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN PERMISSION OF THIS LABORATORY.
THE RECORDING OF FALSE, FICTITIOUS OR FRAUDULENT STATEMENTS OR ENTRIES ON THIS CERTIFICATE MAY BE PUNISHED AS A FELONY UNDER FEDERAL LAW.

MANUFACTURED IN THE USA WITH AMERICAN MADE STEEL CHECKED


(PER REQUIREMENTS OF ASTM F959)
APPLIED BOLTING DIRECT TENSION INDICATOR PRODUCTS ARE MANUFACTURED AND TESTED IN MERCURY FREE ENVIRONMENTS.