Nominal Pipe Size (Header) 300 NB

Outside Diameter (Dh) 323.8 mm


Select Schdule

● Standard Extra Strong Double Extra Strong

5s 10s 20s 30s 40s 60s 80s


Th
100s 120s 140s ● 160s 33.32
Inside Diameter (Dhi)
257.16
Weight / M 238.69

NA - Not Availble

Nominal Pipe Size (Branch) 25 NB


Outside Diameter (Db) 33.4 mm
Select Schdule 160

Tb 6.35
Inside Diameter (Dbi) 20.70
Weight / M 4.24
mm
mm
Kg

mm
mm
Kg
Branch Re-inforcement Calculation ASME B31.1 104.3.1
TITLE
SUBJECT
Header: Branch:
Outside Diameter, Dh = 323.80 Outside Diameter, Db = 33.40
Provided Thickness, th = 33.32 Provided Thickness, tb = 6.35
Design Pressure, P (Kg/cm2) = 121.00 Design Pressure, P (Kg/cm2) = 121.00
Design Temperature, Th (oC) = 474.00 Design Temperature, Th (oC) = 474.00
Material of Construction SA 335 P22 Material of Construction SA 335 P22
Allowance, A = 1.00 Allowance, A = 1.00
Allowable stress, SE (Kg/cm2) = 972.7100176 Allowable stress, SE (Kg/cm2) = 972.7100176

Angle between axes of branch & run B, deg = 90

Required Reinforcement Area


A7= (tmh-A)*d1(2-SinB) tmh= P.Dh/(2.(SE+Py))+A tmb= P.Db/(2.(SE+Py))+A
= 20.185 mm = 2.983 mm
A7= 397.128 mm2
Hole dia., d1= [Db-2.(Tb-c)]/SinB
= 22.700 mm

Excess Thickness in Run Pipe Wall


A1= (2d2-d1)(th-tmh) d2= (tb-A)+(th-A)+d1/2 or d1
A1= 989.598 mm2 = 49.020 or 22.700 (which ever is greater)
= 49.020 mm

Excess Thickness in Branch Pipe Wall


A2= 2.L4.(Tb-tmb)/SinB L4= 2.5.(Th-A) or 2.5.(Tb-A)+tr
A2= 90.067 mm2 = 80.800 or 13.375 (which ever is less)
= 13.375 mm

A3 & A4 Area Provided by Welds and Attachments (Not Included).

AReq= Additional replacement area required = A7-A1-A2

AReq= -682.537 mm2

Using Pipe of min thickness 0.000 mm

A Pad of minimum width 0.00 mm is required.