Sie sind auf Seite 1von 11

This document is the property of Wärtsilä Moss AS and shall be treated as confidential.

Information from this description shall not be shown nor given to any 3rd party without
written acceptance by Wärtsilä Moss AS.

WÄRTSILÄ MOSS AS
EXHAUST GAS SCRUBBING SYSTEM (EGC)
EGC System - Alarm List

5 20.6.2017 Revised VL
4 24.5.2016 Revised GH
3 27.3.2016 Revised VL
2 15.6.2015 Revised HNF
1 20.4.2015 Revised GH
0 8.1.2015 For approval AN
For approval
Rev. Date Description Approved by
Client / Client ref: Project no./ Order no:
RCCL SP01954
Hull No:

Ship Name
Oasis of the Seas
Document title: Document Name.:
EGC System - Alarm List SP01954_EGC_Alarm_List

Rev.
5
ALARM DESCRIPTION
EXHAUST CLEANING SYSTEM
Critical Non Critical GROUP DESCRIPTION OF ACTION REV
A 1. All automatic valves to shut down position
x Alarm/Instantaneous Stop 2. Stop all motors
All scrubbers 3. Audible and visual alarm
B 1. All Automatic Valves To Shut Down Position
x Alarm/Instantaneous Stop 2. Stop Of All Motors
Individual Scrubber 3. Audible And Visual Alarm
C 1. All automatic valves related to venturi to shut down position
x Alarm/Instantaneous Stop 2. Audible and visual alarm
Individual Venturi
D 1. Open bypass valves for related scrubber
x Alarm/System Cool Down 2. Normal system cool down for related scrubber
Individual Scrubber 3. Audible and visual alarm
E 1. Open bypass valves for related venturi
x Alarm/System Cool Down 2. Normal system cool down for related venturi
Individual Venturi 3. Audible and visual alarm
F 1. Stop Failed Pump
x Alarm/Start Backup Pump 2. Start Backup Pump
3. Audible and visual alarm
G 1. Close Automatic Valves, Sludge System
x Alarm/Shut Down Sludge System 2. Stop Sludge Pumps
3. Audible and visual alarm
H 1. Close Automatic Valves, Alkali System
x Alarm/Shut Down Alkali System 2. Stop Alkali Pumps
3. Audible and visual alarm
I 1. Audible and visual alarm
x Alarm

SAFETY 1. All Automatic Valves To Shut Down Position


x* Alarm 2. Stop Of All Motors
3. Audible And Visual Alarm

* If for some reason the PLC is down. This alarm will only be indicated on the "Safety Shutdown System" in the Scrubber Cabinet (SC1)

* X/OL = Alarm Active In OL


* X/CL = Alarm Active In CL

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - CONTROL SYSTEM
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Main Control Panel Power Supply Redundancy Failure I
2 Main Control Panel Switch X100 Fiber Ring Failure I
3 Main Control Panel Switch X100 Copper Ring Failure I
4 Main Control Panel Switch X200 Fiber Ring Failure I
5 Main Control Panel Switch X200 Copper Ring Failure I
6 Main Control Panel Switch X100 Common Alarm I
7 Main Control Panel Switch X200 Common Alarm I
8 Redundancy Failure PLC Main Control Panel +MCP1S I
9 NS1 Switch X100 Fiber Ring Failure I
10 NS1 Switch X100 Copper Ring Failure I
11 NS1 Switch X200 Fiber Ring Failure I
12 NS1 Switch X200 Copper Ring Failure I
13 NS1 Switch X100 Common Alarm I
14 NS1 Switch X200 Common Alarm I
15 NS2 Switch X100 Fiber Ring Failure I
16 NS2 Switch X100 Copper Ring Failure I
17 NS2 Switch X200 Fiber Ring Failure I
18 NS2 Switch X200 Copper Ring Failure I
19 NS2 Switch X100 Common Alarm I
20 NS2 Switch X200 Common Alarm I
21 Main Control Panel +MCP1S Touch Screen Communication Failure I
22 TSP1 Touch Screen Communication Failure I
23 Data Logger Communication Failure I
24 Main Control Panel +MCP1S I/O Communication Failure - Shutdown A
25 Gas Analyser System +CEMS1S Communication Failure I
26 Sea Water Monitoring Module +SWMM1S Communication Failure I
27 Wash Water Monitoring Module +WWMM1S Communication Failure I
28 Effluent Monitoring Module +EMM1S Communication Failure I
29 Process Water Monitoring Module +PWMM1S Communication Failure I
30 Alkali Feed Module +AFM1S Communication Failure I
31 Residence Tank +RET1S Communication Failure - Shutdown OL A/OL
32 Process Tank +PRT1S Communication Failure - Shutdown CL A/CL
33 Wash Water Pump 1 +WWP1S Communication Failure I
34 Wash Water Pump 2 +WWP2S Communication Failure I
35 +BOTU1S WT-511 Communication Failure I
36 +BOTU1S WT-512 Communication Failure I
37 Scrubber 1 +SC1S Communication Failure - Shutdown A
38 Sea Water Pump P-101 +SWP1S Communication Failure I
39 Sea Water Pump P-102 +SWP2S Communication Failure I
40 Sea Water Pump P-103 +SWP3S Communication Failure I
41 Sea Water Cooling Pump P-107 +SWCP1S Communication Failure I
42 Make Up Water Pump P-108 +TRP2S Communication Failure I
43 Sealing Air Fan +SAF1S Communication Failure I
44 Deplume Air Fan +DAF1S Communication Failure I
45 Effluent Transfer Pump P-606 +TRP1S Communication Failure I
46 GPS Communication Failure I
47 Communication To Ship System Lost I

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - SYSTEM COMMON
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Instrument Air Pressure PS-801S Low Low - Shutdown PALL-801 A 5,5 bar
2 Instrument Air Pressure PS-811S Low Low - Shutdown PALL-811 A
3 Emergency Stop - Shutdown A
4 Safety Shutdown Alarm SC-200 - Shutdown (DK18) A
5 Scrubber Design Load Exceeded (2x85%MCR) I
6 Water Leakage A

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - WATER MONITORING
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Scrubbing Water Monitoring System Communication Failure I
2 Scrubbing Water Monitoring System 15N06/10 Water Flow Alarm I
3 Scrubbing Water Monitoring System 15N06/10 I/O Fault Alarm I
4 Scrubbing Water Monitoring System In Local Mode I
5 Scrubbing Water Monitoring System 15N06/10 PAH Sensor Fault Alarm I
6 Scrubbing Water Monitoring System 15N06/10 Turbidity Sensor Fault Alarm I
7 Scrubbing Water Monitoring System 15N06/10 pH Sensor Fault Alarm I
8 Scrubbing Water Monitoring System 15N06/10 Temperature Sensor Fault Alarm I
9 Wash Water Monitoring System Communication Failure I
10 Wash Water Monitoring System 15N06/20 Water Flow Alarm Alarm I
11 Wash Water Monitoring System 15N06/20 I/O Fault Alarm I
12 Wash Water Monitoring System In Local Mode I
13 Wash Water Monitoring System 15N06/20 PAH Sensor Fault Alarm I
14 Wash Water Monitoring System 15N06/20 Turbidity Sensor Fault Alarm I
15 Wash Water Monitoring System 15N06/20 pH Sensor Fault Alarm I
16 Wash Water Monitoring System 15N06/20 Temperature Sensor Fault Alarm I
17 Effluent Water Monitoring System Communication Failure I
18 Effluent Water Monitoring System 15N06/21 Water Flow Alarm Alarm I
19 Effluent Water Monitoring System 15N06/21 I/O Fault Alarm I
20 Effluent Water Monitoring System In Local Mode I
21 Effluent Water Monitoring System 15N06/21 PAH Sensor Fault Alarm I
22 Effluent Water Monitoring System 15N06/21 Turbidity Sensor Fault Alarm I
23 Effluent Water Monitoring System 15N06/21 pH Sensor Fault Alarm I
24 Effluent Water Monitoring System 15N06/21 Temperature Sensor Fault Alarm I
25 Process Water Monitoring System Communication Failure I
26 Process Water Monitoring System Water Flow Alarm I
27 Process Water Monitoring System 15N06/40 I/O Fault Alarm I
28 Process Water Monitoring System In Local Mode I
29 Process Water Monitoring System 15N06/40 Density Sensor Fault Alarm I
30 Process Water Monitoring System 15N06/40 pH Sensor Fault Alarm I
31 High Turbidity Differential I 25 FNU
32 High PAH Differential I 50 ppb
33 Low Wash Water pH To Sea I 2,7 pH
34 CL Effluent monitoring system, low pH I 6,5 pH
35 CL Effluent monitoring system, high PAH I 400 ppb
36 CL Effluent monitoring system, high Turbidity I 25 FNU
37 High Process Water Density I 1100
38 High High Process Water Density I 1120
39 Low Process Water pH I 5,5
40 Low Low Process Water pH I 5

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - SW SUPPLY SYSTEM
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 SW Pump P-101 Starter Fault F
2 SW Pump P-101 Starter Warning I
3 SW Pump P-102 Starter Fault F
4 SW Pump P-102 Starter Warning I
5 SW Pump P-103 Starter Fault F
6 SW Pump P-103 Starter Warning I
7 SW Pump P-107 Starter Fault I
8 SW Pump P-107 Starter Warning I
9 SW Pump P-108 Starter Fault I
10 SW Pump P-108 Starter Warning I
11 SW To Main Pumps Valve SV-150 Position Failure A
12 SW Cooling Valve CV-110 Position Failure I
13 SW Cooling Valve CV-111 Position Failure I
14 CW Low Temperature TT-190S TAL-190 I 15°C
15 SW Cooling Bypass Valve CV-101 Position Failure B/C
16 SW Inlet (Yard) Valve HV-150 Position Failure A
17 SW Pump SWP Power Difference I Power Diff > 10 %
18 Cooling Water Outlet Valve HV-171 Position Failure A/CL
19 Seawater Inlet Valve 7424V002 Position Failure A
20 Seawater Inlet Valve 7424V007 Position Failure A
21 Seawater Inlet Valve 7424V008 Position Failure A
22 Seawater Inlet Valve 7424V009 Position Failure A

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - WATER TREATMENT OPEN LOOP
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Residence Tank TK-601 High Level LAH-601 I 85%
2 Residence Tank TK-601 High High Level - Shutdown LAHH-601 A Level Switch
3 ResidenceTank TK-601 Vent Fan FN-601 Running Failure I
4 ResidenceTank TK-601 Vent Valve SV-613 position Failure I
5 Settling Tank TK-603 High High Level - Shutdown Sludge System LAHH-603 G\OL Level Switch
6 OverBoard Valve HV-706 Position Failure - Shutdown OL A/OL
7 OverBoard Valve HV-713 Position Failure - Shutdown OL A/OL
8 OverBoard Valve HV-714 Position Failure - Shutdown OL A/OL
9 OverBoard Valve HV-715 Position Failure - Shutdown OL A/OL
10 OverBoard Valve HV-716 Position Failure - Shutdown OL A/OL
11 Scrubber Drain Valve SV-601 Position Failure - Shutdown A
12 Residence Tank TK-601 Outlet Valve HV-611 Position Failure - Shutdown OL A/OL
13 Hydro Cyclone HC-501 Drain Valve SV-501 Position Failure I
14 Hydro Cyclone HC-501 Pump P-501 Fault I
15 Hydro Cyclone HC-501 Pump P-501 Warning I
16 Hydro Cyclone HC-501 Pump P-501 Low Load I
17 Hydro Cyclone HC-502 Drain Valve SV-502 Position Failure I
18 Hydro Cyclone HC-502 Pump P-502 Fault I
19 Hydro Cyclone HC-502 Pump P-502 Warning I
20 Hydro Cyclone HC-502 Pump P-502 Low Load I
21 Sludge Tank TK-603 High High Level LAHH-613 G\OL 80%

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
LIST
EXHAUST CLEANING SYSTEM - WATER TREATMENT CLOSED LOOP
NO DESCRIPTION LABEL GROUP SETTING CHECKED COMMENT REV
Switch Trip or
1 Process Tank TK-602 High High Level - Shutdown CL LAHH-602 A/CL 99%
Transmitter above 99%
2 Process Tank TK-602 High Level LAH-602 I 85%
3 Process Tank TK-602 Low Level LAL-602 I 20%
4 Process Tank TK-602 Vent Fan FN-602 Running Failure I
5 Process Tank TK-602 Vent Valve SV-634 Position Failure I
6 Sludge Tank TK-605 High Level LAH-605 I
7 Process Tank TK-602 Outlet Valve HV-642 Position Failure - Shutdown CL A/CL
8 Process Tank TK-602 Outlet Valve SV-642 Position Failure - Shutdown A
9 BOTU 15N05/1 Non Critical I
10 BOTU 15N05/1 Critical I
11 BOTU 15N05/2 Non Critical I
12 BOTU 15N05/2 Critical I
13 Transfer Pump P-606 Fault Alarm I
14 Transfer Pump P-606 Warning Alarm I
15 Alkali Dosing Pump P-607 Failure Shutdown Alkali H
16 Alkali Dosing Pump P-608 Failure Shutdown Alkali H
17 Alkali Transfer Pump P-609 Failure Shutdown Alkali H
18 Scrubber Drain Valve SV-602 Position Failure - Shutdown A
19 Buffer Tank TK-604 Drain Valve Position Failure HV-633 I
20 High Process Water Density (part of Water Monitoring alarm list) AAH-100 I 1140
21 High High Process Water Density (part of Water Monitoring alarm list) AAHH-100 I 1150
22 PH Low Process Water (part of Water Monitoring alarm list) I 5,5
23 PH Low Low Process Water (part of Water Monitoring alarm list) I 5
24 Alkali Tank Outlet Valve SV-607 Position Failure Shutdown Alkali H
25 Alkali Tank 1 Quick Closing Valve QV-374 Position Failure H
26 Alkali Tank Quick Closing Valve SV-360 Position Failure Shutdown Alkali H
27 Alkali Tank TK-607P/S Quick Closing Valve SV-359 Position Failure Shutdown Alkali H
28 Alkali Tank 1 Hand Valve HV-361 Position Failure H
29 Alkali Tank 2 Hand Valve HV-362 Position Failure Shutdown Alkali H
30 Alkali Tank TK-607S Hand Valve HV-363 Position Failure Shutdown Alkali H
31 Alkali Tank TK-607P High Level LAH-607P I 90%
32 Alkali Tank TK-607P Low Level LAL-607P I 10%
33 Alkali Tank TK-607S High Level LAH-698 I 90%
34 Alkali Tank TK-607S Low Level LAL-698 I 10%
35 Alkali Tank TK-607P/S High Level LAH-699 H 10%
36 Alkali Tray High High Level LAHH-637 H
37 Alkali Not Available While Running Closed Loop I
38 Bleed-Off Control Valve CV-604 Position Failure I
39 Effluent Overboard Valve SV-605 Position Failure I
40 Effluent Overboard Valve HV-610 Position Failure I
41 Effluent To Residence Tank Valve SV-608 Position Failure I
42 Effluent To Storage Tank Valve SV-606 Position Failure I
43 Effluent To Buffer Tank Valve SV-604 Position Failure I
44 Effluent Holding Tank TK-606S High Level LAH-606 I 90%
45 Effluent Holding Tank TK-606S High High Level LAHH-606 I Level Switch
46 Effluent Holding Tank TK-606P High High Level LAHH-616 I Level Switch
47 Buffer Tank TK-604 High Level LAH-604 I 90%
48 Buffer Tank TK-604 High High Level LAHH-604 I Level Switch

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - EXHAUST GAS MONITORING SYSTEM
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Gas Monitoring Head 1 Common Fault I

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - SENSORS
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Flow To BufferTank Sensor FT-604S Failure I
2 Residence Tank Open Loop Level Sensor LT-601S Failure Shutdown OL A/OL
3 ProcessTank Closed Loop Level Sensor LT-602S Failure Shutdown CL A/CL
4 Cooler 1 Inlet Sensor TT-190S Failure I
5 TK-603 Level Sensor LT-613S Failure I
6 TK-604 Level Sensor LT-604S Failure I
7 TK-606 Level Sensor LT-606S Failure I
8 Alkali Tank 1 Level Sensor TK-607P Failure I
9 Alkali Overflow Tank Level Sensor LT-699S Failure I

SP01954_EGC_Alarm List_REV5.xlsx
Page 1 of 1
ALARM LIST
EXHAUST CLEANING SYSTEM - SCRUBBER SC-200
NO DESCRIPTION WARTSILA LABEL GROUP SETTING CHECKED COMMENT REV
1 Scrubbing Water Inlet Valve SV-200 Position Failure - Shutdown B
2 Scrubbing Water To Lower Wet Filter Valve SV-201 Position Failure I
3 Demister Flush Valve SV-202 Position Failure I
4 Scrubbing Water To Venturi VN-200 Valve SV-204 Position Failure - Shutdown VN-200 C
5 Scrubbing Water To Venturi VN-220 Valve SV-224 Position Failure - Shutdown VN-220 C
6 Scrubbing Water To Venturi VN-240 Valve SV-244 Position Failure - Shutdown VN-240 C
7 Venturi VN-200 TT-205S Inlet High High Temperature - Cooldown VN-200 TAH-205 E >=450°c
8 Venturi VN-200 PT-205S Inlet High Pressure PAH-205 I >=250 mmWG
9 Venturi VN-200 PT-205S Inlet High High Pressure - Shutdown VN-200 PAHH-205 C >=300 mmWG
10 Scrubber Inlet Temperature From Venturi 1 TT-206 High TAH-206 I >=65°C
11 Scrubber Inlet Temperature From Venturi 1 TT-206 High High Cooldown VN-200 TAHH-206 E >=80°C
12 Venturi VN-220 TT-225S Inlet High High Temperature - Cooldown VN-220 TAH-225 E >=450°c
13 Venturi VN-220 PT225S Inlet High Pressure PAH-225 I >=250 mmWG
14 Venturi VN-220 PT-225S Inlet High High Pressure - Shutdown VN-220 PAHH-225 C >=300 mmWG
15 Scrubber Inlet Temperature From Venturi 2 TT-226 High TAH-226 I >=65°C
16 Scrubber Inlet Temperature From Venturi 2 TT-226 High High Cooldown VN-220 TAHH-226 E >=80°C
17 Venturi VN-240 TT-245S Inlet High High Temperature - Cooldown VN-240 TAH-245 E >=450°c
18 Venturi VN-240 PT-245S Inlet High Pressure PAH-245 I >=250 mmWG
19 Venturi VN-240 PT-245S Inlet High High Pressure - Shutdown VN-240 PAHH-245 C >=300 mmWG
20 Scrubber Inlet Temperature From Venturi 3 TT-246 High TAH-246 I >=65°C
21 Scrubber Inlet Temperature From Venturi 3 TT-246 High High Cooldown VN-240 TAHH-246 E >=80°C
22 High High Sea Water Level LS201S - Shutdown LAHH-201 B
23 Low Scrubbing Water Supply Pressure PT-200S PAL-200 I <1,3 Bar
24 Low Low Scrubbing Water Supply Pressure PT-200S - Shutdown PALL-200 B <1,0 Bar
25 Scrubber Outlet High Temperature TT-207S TAH-207 I >=90°C
26 Scrubber Outlet High High Temperature TT-207S - Shutdown TAHH-207 B >=100°C
27 PW Temp TT-200S To SC-200 High Temp TAH-200 I >45°C
28 PW Temp TT-200S To SC-200 High High Temperature - Cooldown TAHH-200 D >50°C
29 Exhaust Gas Outlet High Temperature TAH-208 - <SP - 20°C
30 Exhaust Gas Outlet Low Temperature TAL-208 - >=SP + 20°C
31 PW Temp SC-200 Low Temp TAL-200 I <18°C
32 High SO2/CO2 Ratio AE-200 I >=4,3
33 Low Sealing Air Pressure PS-210S PAL-210 I
34 Deplume Steam Valve CV-205 Position Failure I
35 Deplume Inlet Valve SV-225 Position Failure I
36 Steam Cleaning Valve SV-208 Position Failure I
37 Exhaust Gas Bypass Damper SV-210 Position Failure C
38 Exhaust Gas Bypass Damper SV-230 Position Failure C
39 Exhaust Gas Bypass Damper SV-250 Position Failure C
40 Sealing Air Valve SV-214 Position Failure C
41 Sealing Air Valve SV-215 Position Failure C
42 Sealing Air Valve SV-234 Position Failure C
43 Sealing Air Valve SV-235 Position Failure C
44 Sealing Air Valve SV-254 Position Failure C
45 Sealing Air Valve SV-255 Position Failure C
46 Venturi VN-200 Inlet Temp TT-205 Sensor Failure - Shutdown VN-200 C
47 Venturi VN-220 Inlet Temp TT-225 Sensor Failure - Shutdown VN-220 C
48 Venturi VN-240 Inlet Temp TT-245 Sensor Failure - Shutdown VN-240 C
49 Venturi VN-200 Inlet Press. PT-205 Sensor Failure - Shutdown VN-200 C
50 Venturi VN-220 Inlet Press. PT-225 Sensor Failure - Shutdown VN-220 C
51 Venturi VN-240 Inlet Press. PT-245 Sensor Failure - Shutdown VN-240 C
52 Inlet Temp From VN-200 TT-206 Sensor Failure I
53 Inlet Temp From VN-220 TT-226 Sensor Failure I
54 Inlet Temp From VN-240 TT-246 Sensor Failure I
55 Outlet Temp TT-207 Sensor Failure - Shutdown B
56 Outlet Press PT-207 Sensor Failure I
57 Scrubbing Water Press PT-200 Sensor Failure - Shutdown B
58 Scrubbing Water Flow FT-200 Sensor Failure I
59 Water Temp TT-200 Sensor Failure D
60 Deplume Temp TT-208 Sensor Failure I <10°C or > 100 °C
61 Deplume Air Fan FN-200 Fault I
62 Deplume Air Fan FN-200 Warning I
63 Sealing Air Fan FN-202 Fault I
64 Sealing Air Fan FN-202 Warning I
65 Scrubber Drain Valve HV-206 Position Failure Shutdown B