Beruflich Dokumente
Kultur Dokumente
The NO CODING
technology
provides accurate
and fast blood
glucose monitoring
USER GUIDE
i ii
TM
iii iv
STARTED
GETTING
is about simplicity. You will notice this the first time you use it.
Intended Use, Important Safety Information ..................... i
Automatic: Bayer’s CONTOUR PLUS meter is designed with Precautions .......................................................................iii
No Coding™ technology, to automatically code itself every
Your Meter Features .......................................................... v
time you insert a test strip. It will also automatically mark a
control solution test. Your CONTOUR®PLUS Meter ............................................. 2
Enough Blood: The CONTOUR PLUS meter alerts you when Getting Ready to Test........................................................ 6
TESTING
a test strip is under-filled and allows you to add more blood. Getting the Blood Drop ................................................... 10
Your test strip is designed to easily "sip" the blood into the Testing Your Blood .......................................................... 10
sample tip. Do not drop blood directly on the flat surface of the Alternative Site Testing (AST) - Palm .............................. 14
test strip.
Control Solution Testing .................................................. 20
CAUTION: Your CONTOUR PLUS meter ONLY works with
CONTOUR PLUS test strips and CONTOUR PLUS control
solution.
TECHNICAL,
NOTE: CONTOUR PLUS blood glucose strip (FAD Glucose Caring for Your Meter and Cleaning Your Meter ............. 48
Dehydrogenase method) is abbreviated in this user guide Symptoms of High or Low Blood Glucose ..................... 49
as test strip. Specifications .................................................................. 50
Service Information ......................................................... 55
TM
Warranty .......................................................................... 56
v Supplies........................................................................... 58
STARTED
GETTING
STARTED
GETTING
TM
2 3
STARTED
GETTING
STARTED
GETTING
on your meter display. To view, with the meter off, press Top area on the display presenting date and time.
and hold ▲ or ▼. All display segments will appear
for 10 seconds. If you need more than 10 seconds to Pre-meal result marker.
check the display, press and hold ▲ or ▼ again.
Post-meal result marker.
Day/month format.
4 5
TESTING
TESTING
meter, CONTOUR PLUS test strips, and the the endcap off from
MICROLET 2 lancing device and MICROLET™ lancets. top to bottom.
You may also need CONTOUR PLUS control solution
to perform a quality control check.
2. Loosen the round
WARNING protective cap on a
• All parts of the kit are considered biohazardous lancet by rotating it
and can potentially transmit infectious diseases, ¼ turn, but do not
even after you have performed cleaning. See remove it. Always use
page 48. MICROLET lancets for
the best operation.
• Always wash and dry your hands well with soap
and water before and after testing, handling the
meter, lancing device, or test strips.
TM
6 7
TESTING
TESTING
TESTING
TESTING
10 11
TESTING
TESTING
NOTE: You can set your meter to use meal marker • If your blood sugar reading is under 50 mg/dL,
options. See Advanced Mode settings (L-2) on follow medical advice immediately.
pages 27 - 29. If you want to mark your result you will • If your blood sugar reading is over 250 mg/dL,
need to do it before removing the test strip. wash and dry your hands well and repeat the
test with a new strip. If you get a similar result,
6. Remove the test strip to call your health care professional as soon as
turn your meter off. Dispose possible.
Testing Your Blood
TM
12 13
TESTING
TESTING
conditions:
3. Select a puncture site
• If you think your blood sugar is low from a fleshy area on
• When blood sugar is changing rapidly (after a meal, the palm. Avoid veins,
insulin dose or exercise) moles, bones and
• If you are unable to feel symptoms of low blood tendons.
sugar (hypoglycaemic unawareness)
Alternative Site Testing (AST) - Palm
Testing
Getting a Blood Drop for Alternative Site
• If you get alternative site blood sugar results that do
not agree with how you feel
• During illness or times of stress 4. Press the clear
• If you will be driving a car or operating machinery endcap firmly against
the puncture site and
Alternative Site results may be different from fingertip then press the blue
results when glucose levels are changing rapidly (e.g., release button.
after a meal, after taking insulin, or during or after
exercise). Additionally, glucose levels may not rise as
high or fall as low as levels in the fingertip. As such,
fingertip results may identify hypoglycaemic levels
sooner than alternate site results.
5. Maintain steady
Alternative Site Testing is recommended only when it is more pressure until a small,
than 2 hours after a meal, diabetes medication or exercise. round blood drop
If you do not have a clear endcap to perform AST, contact forms.
Bayer Diabetes Care Customer Support in your Country.
14 15
TESTING
TESTING
Testing
Getting a Blood Drop for Alternative Site
of blood. The blood is pulled into the test strip through blood within that time, an
the tip. error code will be displayed.
Dispose of the used test
Do not test the blood sample from palm if you get:
strip as medical waste or as
• Smeared blood advised by your health care
• Clotted blood professional and start over
• Runny blood with a new strip.
• Clear fluid mixed with the blood Please see Expected Test Result Values on page 13.
TM
16 17
TESTING
TESTING
TM
18 19
TESTING
TESTING
TM
20 21
8. Hold it in the drop until the meter beeps. If your control test result is out of range, do not
use your meter for blood glucose testing until you
resolve the issue. See “What You Should Do” on
TESTING
TESTING
page 45.
9. The meter will count down
for 5 seconds and the
control test result will
11. Remove the test strip
display on the meter.
and dispose of it as
medical waste or as
advised by your health
Control Solution Testing
TM
22 23
TM
24 25
along with the word . Mode and offers the same easy test procedure in either
This option controls whether the Basic or Advanced Mode.
you want to hear the beep
Reminder Settings
will help you track these HI
and LO results.
The LO setting will flash You have now completed
(default 72 mg/dL). To your CONTOUR®PLUS meter
change this setting, press set-up for Advanced Mode!
▲ or ▼ until you reach your
desired LO setting, and
then press M to set. (The
range of values for LO is
SETUP AND USE
TM
28 29
Post-meal = Marks a
test result that was taken The will then flash. This
after a meal. feature allows you to set a
reminder to remind you to
Diary = The diary marker can be used to mark run a post-meal test.
any result as being unique or different in some way, The reminder is available
and for which you may want to make notes in your only after setting a pre-meal
SETUP AND USE
TM
32 33
Result is marked as a
Pre-Meal
Press M pre-meal test. You can
Press ▲ or ▼ (Flashing) now set a reminder.
TM
34 35
TM
36 37
TM
38 39
TM
40 41
TECHNICAL,
pages 24 - 25 to reset the date or
Invalid date or
E10 time. If you continue to see
time.
this error, please contact Bayer
Diabetes Care Customer Support
in your Country.
TM
42 43
TECHNICAL,
displayed This may affect Contact Bayer Diabetes Care
in expected the way you see Customer Support in your
units of your results. Country.
measure
(mg/dL).
44 45
TECHNICAL,
bottom of the battery up.
TM
46 47
TECHNICAL,
should be handled as if capable of transmitting
infectious diseases. The user should follow the
recommendations for prevention of blood-borne
transmissible diseases in health care settings
as recommended for potentially infectious
48 human specimens. 49
CONTOUR®PLUS meter complies with the is designed for use with capillary and venous whole
electromagnetic requirements specified in ISO 15197: blood. Comparison to a laboratory method must be
2003. Electromagnetic emissions are low and unlikely done simultaneously with aliquots of the same sample.
to interfere with other nearby electronic equipment, nor NOTE: Glucose concentrations drop rapidly due to
are emissions from nearby electronic equipment likely glycolysis (approximately 5 - 7% per hour).8
to interfere with the CONTOUR PLUS system. Immunity
to electrostatic discharge meets the requirements of
IEC 61000-4-2: 2008. It is advisable to avoid use of
SERVICE & CARE
TECHNICAL,
if synthetic materials are present. The CONTOUR PLUS
meter has been tested for radio frequency interference
at the frequency range and test levels specified
by ISO 15197: 2003. To avoid radio frequency
50 51
Technical Information
irradiation
Table 2 – System accuracy results for glucose
Catalogue number Warning
concentration ≥ 75 mg/dL
Symbols Used
TECHNICAL,
be disposed of with waste electronic equipment. range
Contact your health care professional or local waste disposal *Acceptance criteria in ISO 15197: 2003 are that 95% of all
authority for medical waste disposal guidelines. differences in glucose values (i.e., between reference method
and meter) should be within 15 mg/dL for glucose values less than
TM
75 mg/dL, and within 20% for glucose values greater than or equal
52 to 75 mg/dL. 53
Service Information
131 1,98 1,5 1. Locate the serial
¯
number (A) and model
210 2,88 1,3 A number (B) on the back
of the meter.
333 4,86 1,5 –––––––––––––––––––––
¯
–––––––––––––––––––––
B 84708306
TECHNICAL,
3. Check the battery icon on the display.
(See page 46, Changing the Batteries.)
TM
54 55
Warranty
Warranty
TECHNICAL,
meter when used with any test strips other than
CONTOUR PLUS test strips, and therefore makes no
TM
56 57
References
7 CDC Clinical Reminder: Use of Fingerstick Devices
on More than One Person Poses Risk for Transmitting
Bloodborne Pathogens (2010). http://www.cdc.gov/
injectionsafety/Fingerstick-DevicesBGM.htm
8 Tietz Fundamentals of Clinical Chemistry, 5th Edition,
Edited by Burtis CA and Ashwood ER, W. B. Saunders Co.,
Philadelphia, PA, 2001, p. 444.
SERVICE & CARE
TECHNICAL,
TM
58 59
TM
60 61
0088