Sie sind auf Seite 1von 1

SIMATIC se_bed\ 18.10.

2014 16:15:58
SIMATIC 300(1)\CPU 314IFM\...\FC2 - <offline>

FC2 - <offline>
""
Name: Familie:
Autor: Version: 0.1
Bausteinversion: 2
Zeitstempel Code: 18.10.2014 16:14:12
Interface: 18.10.2014 15:32:17
Längen (Baustein / Code / Daten): 00204 00090 00006

Name Datentyp Adresse Kommentar


IN 0.0
_DINT DInt 0.0 Double word in integer format
OUT 0.0
_INT Int 4.0 Word in integer format
FAULT Bool 6.0 Fault
IN_OUT 0.0
TEMP 0.0
Temp_DINT DWord 0.0 Caching DINT in local variables
Temp_INT Word 4.0 Caching INT in local variables
RETURN 0.0
RET_VAL 0.0

Baustein: FC2 DINT > INT

Netzwerk: 1 Reset Fault

CLR
= #FAULT #FAULT -- Fault

Netzwerk: 2 Check admissibility, where appropriate, issue error

L #_DINT #_DINT -- Double word in integer format


L L#32767
>D
JC FLT
L #_DINT #_DINT -- Double word in integer format
L L#-32768
<D
JC FLT
JU M001
FLT: = #FAULT #FAULT -- Fault
L 0
T #_INT #_INT -- Word in integer format
BEU

Netzwerk: 3 For admissibility convert DINT to INT

M001: L #_DINT #_DINT -- Double word in integer format


T #Temp_DINT #Temp_DINT -- Caching DINT in local variables
L LW 2
T #Temp_INT #Temp_INT -- Caching INT in local variables
A L 0.7
= L 4.7
L #Temp_INT #Temp_INT -- Caching INT in local variables
T #_INT #_INT -- Word in integer format

Seite 1 von 1