Sie sind auf Seite 1von 2

REFERENCE CALCULATIONS OUTPUT

BASE PLATE AND BOLT DESIGN


REACTION FORCES
Critical Force & Moment for Trains 1 & 2
SACS Output Files
JOINT LC FX [kN] FY [kN] FZ [kN] Moment, M X [kNm] Moment, M Y [kNm] Moment, M Z [kNm]
1C 2041 509.755 3.451 54.074 -1.681 55.565 -0.64

Maximum reaction forces of 168.28 x 12.5 mm thick pipe is:


FZ = P = Axial Load = 54.074 kN = 12.16 kips 12.16 kips
SACS Output Files
FX = 509.755 kN = 114.59 kips 114.59 kips
Check Plate dimensions 340 mm x 377 mm
Fy = 36 ksi 36 ksi
Allowable bearing stress, F p = 0.7x (0.3Fy) 7.56 ksi
Req'd. Plate Area, A 1 = P/Fp = 12.16/7.56 1.61 in2

REFERENCE CALCULATIONS OUTPUT


Determination of plate dimensions B and C;

d = depth of section (outer pipe diameter) = 168.28 = 6.625 in


di =inner pipe diameter = 168.28 -(12.5*2)mm =143.275 mm 5.64 in
critical section used to determine the plate thickness = 0.8d =134.6 mm
AISC Design of
Column Base
Plates, John T.De
Wolf, pg 5,6

For checking thickness of plate, use the greater of m and n.

C= 14.80 in
B= 13.39 in
Actual Bearing Pressure, Fp = P/CB =12.16/14.8*13.39 0.06136 ksi
Determine m and n from figure above;
n= 2.23 in
m = 13.39 - (0.8 * 6.625)/2= 4.045 in
since m > n;
Plate Thickness, tp = m√ Fp/0.25Fy = 4.75√0.061/0.25*36 0.39 in
Plate thickness of 0.39 in = 9.91 mm is required
Provide 25 mm thick plate = 0.984 in 0.984 in
Plate 340 mm x 377 mm x 25 mm thick is adequate

REFERENCE CALCULATIONS OUTPUT


BOLTS
Check for Shear Capacity
Assume 4 No of A490X bolts, 25 mm dia = 1 in
Total Shear Force at Node W = 114.59 kips

AISC 9th Ed Table 1- Shear per bolt = 114.59/4 = 28.65 kips


D Allowable Shear per bolt = 31.40 kips
28.65 kips < 31.40 kips Bolt Shear Stress OK Shear OK

Check Bearing Capacity

AISC 9th Ed Edge distance, lv = 1 1/4 in use (45 mm)


(Table 1-F, 1-E) At fu = 65 ksi, coefficient is 78.0 kips/inch of thickness for 4 bolts.
Allowable load = (78.0 x 4 bolts) x 0.984 = 307.00 kips (1365.6 kN) 1365.60 kN
307.00 kips (1365.60 kN) > 449.801 kN OK

Check for Bolt Tensile Capacity


AISC Design of
Column Base
Bolt Tensile Capacity, Tu = 0.75φtFuAg
Plates, John T.De
Wolf, pg 5,6
where φt is the tensile resistance factor, equal to 0.75
Fu = is the specified minimum tensile strength = 65 ksi
Ag is the gross area = 3.142*12/4 = 0.79 in2
Tu = 0.75*0.75*65*0.79 28.72 kips

AISC 9th Ed, Table Allowable Tensile Load for Grade A490X Bolt = 54.00 ksi
1-A 28.72 ksi < 54.00 ksi OK

AISC-ASD 9th Ed From interaction Equation Table J3.3 of AISC Specification


Table J3.3 Ft = [(542- 1.82(fv)2]0.5
Table 1-D fv = 0.22fu = 0.22*65 = 14.30 ksi
Table J3.3 Ft = [(542- 1.82(14.30)2]0.5 = 50.40 ksi
B = 50.4*0.79 = 39.59 kips

Das könnte Ihnen auch gefallen