Sie sind auf Seite 1von 1

GENERAL

3,125 2,150 3,125


NOTES
A A 1. All dimensions
are in mm
B B
2. All drawings
inconjuction with
discrepancies to
C C
be reported to
D D the engineer
3. Class 25
concrete should
be used
4. MIX Ratios = or
1:1.5:3
5. Cement shall not
be less than
F F Ordinary
Portland cement
G G 32.5
200X200 COLUMN 200X200 COLUMN

6. Cover to
reinforcement
should not be
3,700 4,950 3,700 less than 25mm
Fabric Mesh Type A142 Fabric Mesh Type A142
7. Nominal
1000 Gauge Polythene DPM 1000 Gauge Polythene DPM
aggregate size to
300 mm well compacted hardcore 300 mm well compacted hardcore be used =20mm
50mm blinding 50mm blinding

Soil layer Soil layer

Depth determined on site Depth determined on site

concrete footing concrete footing

50 mm blinding 50 mm blinding

T12-100-B2 T12-100-B2

T12 -01 -200 B1 T12 -01 -200 B1


600 600

3Y8-C Tie links


2300

Double set of links A A


ROYALPRINCE CONSULTANTS
Y8-B CLIENT:
EDWIN IRUNGU
R8-C

4Y16@200mm spacing
FOUNDATIONS AND COLUMN
A A DETAILS
4Y16@200mm spacing
4Y12-A
SECTION
0 Cover on links = 20 mm

BUNGALOW CONSTRUCTION

LINK TYPES:
1 2 3 4

Single link, no Single link with Predominantly linksOnly clips around


clips or links ondiamond link for around middle middle bars.
middle bars. middle bars. bars.

Das könnte Ihnen auch gefallen