DESIGN OF STILLING BASIN

Basic data:
Full reservoir level 364 m
Tail water level 360.2 m
Design Discharge = 25500 cumecs
Total length of spillway = 591.2 m

Calculation
U/s FRL 364
D/s TWL 360.2

The dicharge intensity q 43.13


Silt Factor 7
Scour Depth 8.52
Velocity 5.06
Ha=v2/2g 1.31

U/s TEL 365.31


D/s TEL 361.51
Head Loss 3.8
3.799668
dc = 5.735283
Hl/dc = 0.662565
d1/dc = 0.484581
d1 = 2.779211

y1 2.78
y1^2 7.724015
q^2 1860.422
2gy1^2 151.5452
v2/2g 12.27635
Ef1=y1+v2/2g 15.06
F1 2.97
y2 10.37

D1 = 2.78
D2 = 10.37

y2 10.37
y2^2 107.64
q^2 1860.42
2gy2^2 2111.90
v2/2g 0.88
Ef2=y2+v2/2g 11.26
F2 0.41

Elevation of the basin floor


According to the clause 4.3.2 of IS : 4997 - 1968 , the elevation of the floor
may be calculated by deducting the specific energy at section 2-2 from the
downstream total energy line.
(D/s TEL -Ef2) 350.25 m
(U/s TEL -Ef1) 350.25 m

Length of the concrete floor


From Fig. 8A of IS : 4994 - 1968, length of basin floor is
3 D2 31.12 m
say 31.20 m