iPASOLINK SERIES
(Other Features)
Cross Connections

Page 2 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
CROSS-CONNECTION
Modem Modem Modem Modem
Slot 01 Slot 02 Slot 03 Slot 04 Slot 01 Slot 02 Slot 03 Slot 04

Main Board Main Board


16xE1 16xE1

Modem Modem Modem Modem


Slot 01 Slot 02 Slot 03 Slot 04
Slot 01 Slot 02 Slot 03 Slot 04

SNCP

Main Board Main Board


16xE1 16xE1

Modem 16xE1 Card

Page 3 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
CROSS-CONNECTION
Modem Modem 2 x STM-1 Modem Modem 2 x STM-1
Slot 01 Slot 02 Slot 03 Slot 04 Slot 01 Slot 02 Slot 03 Slot 04

63xE1

STM-1 Through mode STM-1 Channelized mode

Main Board Main Board


16xE1 16xE1

Modem Modem MSE Modem Modem 2 x STM-1


Slot 01 Slot 02 Slot 03 Slot 04 Slot 01 Slot 02 Slot 03 Slot 04

STM-1
SNCP Channelized
mode

Main Board Main Board


16xE1 16xE1

Modem MSE 2 x STM-1 Card

Page 4 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Alarm & Status

Page 5 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
ODU Alarm and Status
Indication Category Descriptions Severity
TXPWR ALM Alarm The TX PWR is lower than 3 dB. MJ
TX INPUT ALM Alarm The TX IF signal become out of range from MJ
-29 dBm ± 5 dB.
RXLEV ALM Alarm The reception level become lower than -72dBm ~ -94dBm level.(It depends on the MJ
modulation system and bit rates).

ODU CPU / Cable CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken or is not MJ
Alarm
Open connected.

Indicates the control status of the ODU TX power output. When the TX power is set
MUTE STATUS Status -
to Mute, Status is issued.
LO REF Alarm Loss of Ref LO signal of ODU. MN
TX SW Status Status Radio interface TX SW usage state in 1+1 HS Redundant configuration -

Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM, ODU SELF
ODU ALM Alarm MJ
CHECK ALM occurrence
Highest
Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU
ODU TOTAL ALM Alarm severity will be
CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.
displayed

ATPC Power Mode Status ATPC control signal fault (90sec) as well as MAX Power continuation 90sec -

ODU TYPE Indicate connected ODU type is not supported at iPASOLINK system, or ODU type
Alarm MJ
MISMATCH cannot use in provisioned modulation setting.
ODU PS ALM Alarm ALM in a case of Power supply interruption to ODU. MJ
ODUPS SET Status Status indication of the protection switch for ODU power supplies -
STATUS

Page 6 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Modem Alarm and Status
Indication Category Descriptions Severity
Unequipped (MODEM-A) Alarm Reserved and installed optional package is removed from optional slot. MJ
Type Mismatch(MODEM-A) Alarm The equipped type of interface is different from configured type. MJ
Communication FAIL(MODEM-A) Alarm Communication failure of equipment internal control communication. MJ
Module(MODEM-A) Alarm Equipment fault MJ
BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 Card. MJ
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 Card. MJ
RXSW STATUS Status Radio interface RX SW usage state in Redundant configuration -
LOSS OF FRAME Alarm Loss of Frame at radio side. MJ
FRAME ID Alarm Frame ID (route differentiation ID) MJ
HIBER ALM Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5) MJ
LOBER ALM Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9) MN
EARLY WARNING Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9) MN
MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, “Alarm” is issued. MJ
IF CABLE SHORT Alarm IF cable between IDU - ODU is in short condition. MJ
INPHASE. Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase -
condition. In this condition, hitless switch over is available.
L2SYNC LOSS Alarm Loss of frame synchronization of GFP frames on MODEM port. MJ
RDI Alarm RDI indication reception alarm on MODEM port MJ
UAE. Alarm UAE alarm. Indicates the occurrence of an Unavailable state. MN
TDM/AMR Range Mismatch Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or MJ
mismatch condition of selected RX AMR modulation range and TX AMR modulation range.
TX SW Reverse Request Status TXSW request signal receiving condition from the opposite station: -
TX SW Lock in Status Status TXSW Lockin state -
Unlocked Alarm Wireless synchronization status of the local side. MJ
MODEM PS OFF Status Indicate power off condition of power switch which is in front of MODEM-A card. -

Page 7 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
16E1 alarm and Status

Indication Category Descriptions Severity

Unequipped (16E1) Alarm Reserved and installed optional package is removed from optional slot. MJ

Type Mismatch(16E1) Alarm The equipped type of interface is different from configured type. MJ

Communication FAIL(16E1) Alarm Communication failure of equipment internal control communication. MJ

Module(16E1) Alarm Equipment fault MJ

BUS ERROR TX Alarm Data communication BUS failure condition in TX direction from STM-1 MJ
Card.
BUS ERROR RX Alarm Data communication BUS failure condition in RX direction from STM-1 MJ
Card.
E1 LOS Alarm No signal input on E1 port MJ

E1 AIS Status ALARM/Status category can change according to " AIS Received MJ / -
Condition Setting

Usage Error Alarm Unused E1 CH input signal detection. MN

E1 AIS Generated Status AIS generation condition on every E1 Channels. -

Page 8 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
GbE-A option card

Indication Category Descriptions Severity

Unequipped (GBE-A) Alarm Reserved and installed optional MJ


package is removed from optional slot.
Type Mismatch(GBE- Alarm The equipped type of interface is MJ
A) different from configured type.
Communication Alarm Communication failure of equipment MJ
FAIL(GBE-A) internal control communication.
Module(GBE-A) Alarm Equipment fault MJ

BUS ERROR TX Alarm Data communication BUS failure MJ


condition in TX direction from STM-1
Card..
BUS ERROR RX Alarm Data communication BUS failure MJ
condition in RX direction from STM-1
Card..
SFP_Type Mismatch Alarm Mismatch between SFP on LCT and MJ
(ETH) installed SFP.
SFP Unequipped Alarm A SFP is removed. MJ
(ETH)
LAN LINK Alarm LINK of the LAN Port is disconnected. MJ
Speed & Duplex Status LAN Port setting (Speed&Duplex) -

Page 9 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Equipment Common alarm and Status-1
Indication Category Descriptions Severity
MODULE (Main Board) Alarm Equipment fault MJ
BUS ERROR Alarm Data communication BUS failure condition. MJ
Unequipped (PS) Alarm Installed Power Supply Module is removed from PS slot. MJ
Power Supply Alarm Alarm in case of power failure. MJ
FAN Fail Alarm FAN failure MJ

Unequipped (FAN) Alarm Installed FAN Module is removed from FAN slot. MJ
Unequipped (CLK2M) Alarm Installed CLK2M Module is removed from Main Card. MJ
Type Mismatch (CLK2M) Alarm The equipped type of interface is different from configured type. MJ
IDU CPU Alarm Alarm. IDU CPU Alarm MN
Memory Failure Alarm Detection of memory failure MJ
USB Failure Alarm USB memory failure indication MJ
Temperature Alarm The temperature is over the threshold MN
Maintenance Status Maintenance declaration. -
CLK FAIL Alarm Reference Clock Failed. MN
CLK Drift Alarm Reference Clock source Frequency drift condition MN
LTI Alarm Loss of all incoming timing source MJ
CLK Status Changed Status Reference clock change status -
(1) (Locked Ref1)
(2) (Locked Ref2)
(3) (Locked Ref3)
(4) Holdover
(5) Freerun
SSM FAIL Alarm Received Sync Status Message value is in unstable condition. MN
Quality Level Status Received quality level condition of each timing source. -
Squelch Status The condition of External CLK Output is in squelch condition. -

Page 10 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Equipment common Alarm and Status -2
Indication Category Descriptions Severity

EXT CLK Condition Status Condition level of External CLK output. -

EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN

EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN

EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN

EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJ
Item Name (Input-x) Status/ - or Severity
Item Name (Cluster-x) Alarm HKA Status Indication {Alarm, Normal} for every HKA input. selectable

Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -

E1 LOS Alarm No signal input on E1 port MJ


PDH – AIS
E1 AIS Status ALARM/Status category can change according to " AIS Received Condition Setting MJ / -

Usage Error Alarm Unused E1 CH input signal detection. MN

E1 AIS Generated Status AIS generation condition on every E1 Channels. -

ETH LOS Alarm LOS detection at Optical Ethernet port. MJ

ETH TF Alarm Transmit Fail detection at Optical Ethernet port. MJ

SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ

SFP Unequipped (ETH) Alarm A SFP is removed. MJ

LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

Speed & Duplex Status LAN Port setting (Speed&Duplex) -

ETH-OAM LOC Alarm MJ

ETH-OAM Mismerge Alarm Ether OAM Mismatch Detection notice. MN

ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN

ETH-OAM RDI Alarm Ether OAM RDI reception detection notice MJ

Page 11 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Equipment common Alarm and Status -2
Indication Category Descriptions Severity

EXT CLK Condition Status Condition level of External CLK output. -

EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN

EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input. MN

EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN

EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output. MJ
Item Name (Input-x) Status/ - or Severity
Item Name (Cluster-x) Alarm HKA Status Indication {Alarm, Normal} for every HKA input. selectable

Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -

E1 LOS Alarm No signal input on E1 port MJ


PDH – AIS
E1 AIS Status ALARM/Status category can change according to " AIS Received Condition Setting MJ / -

Usage Error Alarm Unused E1 CH input signal detection. MN

E1 AIS Generated Status AIS generation condition on every E1 Channels. -

ETH LOS Alarm LOS detection at Optical Ethernet port. MJ

ETH TF Alarm Transmit Fail detection at Optical Ethernet port. MJ

SFP_Type Mismatch (ETH) Alarm Mismatch between SFP on LCT and installed SFP. MJ

SFP Unequipped (ETH) Alarm A SFP is removed. MJ

LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

Speed & Duplex Status LAN Port setting (Speed&Duplex) -

ETH-OAM LOC Alarm MJ

ETH-OAM Mismerge Alarm Ether OAM Mismatch Detection notice. MN

ETH-OAM Unexpected Period Alarm Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice MN

ETH-OAM RDI Alarm Ether OAM RDI reception detection notice MJ

Page 12 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]
Equipment common Alarm and Status -3

Indication Category Descriptions Severity


RSTP New Root Bridge The notice in which new RootBridge was detected at the time of SpanningTree
Detect Status processing -
The notice in which a Topology change was detected at the time of SpanningTree
RSTP Topology Changed Status processing -
The notice which received a Bridge protocol Data Units different in classification
RSTP Protocol Migration Status of RSTP/STP at the time of SpanningTree processing -
RSTP Invalid BPDU
Received Status Invalid BPDU message at the time of SpanningTree processing -
Loss of a conditional signaling in which the LLF control signal should be received
LLF Message Timeout Status continuously from the opposite radio equipment.
LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes
LLF Status LINKDOWN. -
The
highest
Severity
will be
IDU TOTAL ALM Alarm IDU TOTAL ALM reported
The number of DynamicEntryDynamic Entry in L2Switch has reached the
Total FDB Full Status maximum number.

FDB Full Status FDB Full indication specified per VLAN basis.

Page 13 © NEC Corporation 2014 e.g. : [NEC Group Internal Use Only]