Sie sind auf Seite 1von 10

Temperatura seca

Altura sobre el nivel del mar

In-

Dif. Presion estatica ΔHs1-2 (mm col.


Medicion canal punto para curva H2O)

pto 1 0
pto 2 0.5
pto 3 0.8
pto 4 1
pto 5 1.5
pto 6 2

MEDICIONES DE CLIM

HORA DE PRESION BAROMETRICA


PUNTO MEDICION PERSIANA MEDICION mmHg Pb (M1)

PUNTO 1 560.7112096195
PUNTO 2 560.7112096195
PUNTO 3 560.7112096195
PUNTO 4 560.7112096195
PUNTO 5 560.7112096195
PUNTO 6 560.7112096195

DIA. 1 (mm)= 800 S1 ( �^3)


ECUACION EC 1. EC 2.
W PESO
ESPECIFICO
a coeficiente p/calculo
PTO. MEDICION PERSIANA 𝐾𝑔⁄�^3 del caudal

PUNTO 1 0.89636186 2.215796012


PUNTO 2 0.89636186 2.215796012
PUNTO 3 0.89636186 2.215796012
PUNTO 4 0.89636186 2.215796012
PUNTO 5 0.89636186 2.215796012
PUNTO 6 0.89636186 2.215796012
Ecuaciones

ω=0,462∗(𝑃𝑏/(273+𝑇𝑠)) ec.1

a=1/√(−0,805+ω/2𝑔(1/ 〖� 2 〗 ^2 −1/ 〖� 1 〗 ^2 ))
ec.2

q=𝑎√(𝐻1−𝐻2)
ec.3

Q=𝑞∗60 ec.4

v=√((𝑃𝑑2∗2(9,81))/ω)
ec.5

H𝑇=𝐻2+𝑃𝑑2
ec.6

N𝑣=(𝑞∗𝐻𝑇)/102
ec.7

N𝐴=(𝑈∗𝐼∗√3∗cosФ)/2
ec.8

η=𝑁𝑣/𝑁𝐴∗100% ec.9
Temperatura seca 16 °c
a sobre el nivel del mar 2500 m.s.n.m

In-put de los datos obtenidosen el canal de ventilacion

Presion dinamica Po 3-4 (mm col. H2O) HT presion total pto 4 (mm col.H2O)

2 162
4 156
6 144
8 126
12 86
20 8

MEDICIONES DE CLIMA MEDICIONES DE VENTILACION - CANAL


DIF. PRESION
TEMPERATURA. *C ESTATICA
PRESION
PRESION ESTATICA EN PUNTO (3- DINAMICA Pd (3-
4) mm Col. H2O
Δ= Ha 1-2 49 mm Col. H2O
T= (M2)
(M4)

16 160 0 2
16 152 0.5 4
16 138 0.8 6
16 118 1 8
16 74 1.5 12
16 -12 2 20

0.503 DIA 2 (mm) 500


EC. 3 EC. 4 EC. 5
q CAUDAL Q CAUDAL 60xq VELOCIDAD EN
PUNTO 5 (3-4)
�^3⁄𝑠 �^3⁄�𝑖� m/s Q CAUDAL PTO 5
(3-4) m3/s

0 0 6.61641616 1.2968175674
1.5668043858 94.0082631484 9.3570254678 1.8339769917
1.9818682028 118.9120921702 11.4599689531 2.2461539148
2.215796012 132.9477607197 13.23283232 2.5936351347
2.7137848017 162.8270881044 16.2068435179 3.1765413295
3.1336087716 188.0165262969 20.9229450131 4.1008972226
Universidad Pedagogica Y
TALLER DE VENTILACION Tecnologica de Colombia

Entregado a: MSc.Ing. Nancy Moreno Chacon

Andres Felipe Bocarejo Mejia


Entregado por: Sara Milena Salamanca Rojas
Mediciones electricas

Voltaje Factor de potencia


Intensidad I(M6)
U(M5) CosФ (M7)

131 6.6 0.83


120 6.6 0.83
129 6.7 0.83
129 6.6 0.83
130 6.7 0.83
131 10 0.9

FACTOR POTENCIA

VOLTAJE U INTENSIDAD I (M6)


(M5)
𝐶𝑜𝑠 𝜙 (𝑀7)

131 6.6 0.83


120 6.6 0.83
129 6.7 0.83
129 6.6 0.83
130 6.7 0.83
131 10 0.9

S2 ( �^3) 0.196
EC. 6 EC. 7 EC. 8 EC. 9
OBSERVACIONES VENTILAD
CAUDAL HT PRESION TOTAL Nv POTENCIA UTIL NA POTENCIA RENIMIENTO DEL
PROMEDIO PTO 4 mm Col. DEL VENTILADOR ABSORBIDA Kw VENTILADOR %
1-2-3 Y 4 H2O Kw

0.64840878 162 0 621.475418213 0


1.70039069 156 2.3962890606 569.2904594317 0.4209255611
2.11401106 144 2.7979315805 621.2597778874 0.4503641923
2.40471557 126 2.7371597795 611.9872438891 0.4472576523
2.94516307 86 2.2880930681 626.0757451579 0.3654658539
3.617253 8 0.245773237 1021.0439510619 0.0240707794
________________________
D M A
FECHA ANTERIOR
MANTENIMIENTO
FECHA ACTUAL
MANTENIMIENTO
OBSERVACIONES VENTILADOR:

_______________________________________________ FIRMA RESPONSABLE


PRESION NA
ESTATICA EN
HT PRESION TOTAL PUNTO (3-4) POTENCIA
q CAUDAL Q CAUDAL 60xq PTO 4 mm Col. H2O mm Col. ABSORBIDA
�^3⁄𝑠 �^3⁄�𝑖� Kw
H2O
0 0 162 160 621.475418
1.56680439 94.0082631484 156 152 569.290459
1.9818682 118.9120921702 144 138 621.259778
2.21579601 132.9477607197 126 118 611.987244
2.7137848 162.8270881044 86 74 626.075745
3.13360877 188.0165262969 8 -12 1021.04395

Curva caracteristica caudal vs Presion estatica


200

150
Presion Estatica

100

50

0
0 0.5 1 1.5 2 2.5 3 3.5

-50
q
Curva caracterisitica Caudal vs Presion total
180
160
140
120
100
HT

80
60
40
20
0
0 0.5 1 1.5 2 2.5 3 3.5
tica
q

Curva caracteristica caudal vs potecia absorbida


1200

1000

3 3.5 800

600
NA

400

200

0
0 0.5 1 1.5 2 2.5 3 3.5
q
Conclusiones

El laboratorio de ventilacion brinda las condiciones necesarias para complementar los conceptos teoricos y ayuda en la parte p
reconociendo los principios de los ductos de ventilacion.

Los resultados del laboratorio de ventilacion respecto a los datos del taller varian mucho, puede tratarse de fallas en los equipo
tambien debido a fugas en las mangueras que hacen que los resultados no correspondan a un valor logico para el calculo de lo
del ventilador.
La ventilacion forzada es indispensable para la seguridad de los trabajadores en las minas y por eso como ingenieros debemos
apropiado para nuestro uso. Es por esto que se hace indispensable trabajar con datos reales en el laboratorio.

Das könnte Ihnen auch gefallen