Beruflich Dokumente
Kultur Dokumente
HYDRAULIC PERFORMANCE
15
Jockey Pump
PVM/PVMI/PVMX 5 Cap: 5M3/Hr; Head: 14Bar
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
PUMP DIMENSIONS
MOTOR Net
DIMENSION [mm] Weight DIMENSION [mm] Net Weight [kg]
PUMP
[kg]
TYPE
P2 DIN Flange DIN Victaulic DIN Flange DIN
D1 D2 D3 D1 D2 D3 Victaulic
Flange Flange
[HP] [KW] H1 H2 H1 H2 H1 H2
PVM 5-2 0,5 0,37 279 474 141 115 — 23,3 257 452 282 477 141 115 — 19,2 20,1
PVM 5-3 0,75 0,55 306 501 141 115 — 24,2 284 479 309 504 141 115 — 20,3 21,2
PVM 5-4 0,75 0,55 333 528 141 115 — 24,8 311 506 336 531 141 115 — 20,8 21,8
PVM 5-5 1,0 0,75 366 601 141 115 — 27,4 344 579 369 604 141 115 — 23,4 24,3
PVM 5-6 1,5 1,1 393 628 141 115 — 29,1 371 606 396 631 141 115 — 25,1 26,0
PVM 5-7 1,5 1,1 420 655 141 115 — 29,6 398 633 423 658 141 115 — 25,6 26,5
PVM 5-8 1,5 1,1 447 682 141 115 — 30,1 425 660 450 685 141 115 — 26,1 27,1
PVM 5-9 2,0 1,5 490 781 177 141 — 39,3 468 759 493 784 177 141 — 35,4 36,4
PVM 5-10 2,0 1,5 517 808 177 141 — 39,9 495 786 520 811 177 141 — 36,0 36,9
PVM 5-11 3,0 2,2 544 835 177 141 — 43,2 522 813 547 838 177 141 — 39,3 40,3
PVM 5-12 3,0 2,2 571 862 177 141 — 43,7 549 840 574 865 177 141 — 39,9 40,8
PVM 5-13 3,0 2,2 598 889 177 141 — 44,2 576 867 601 892 177 141 — 40,4 41,4
PVM 5-14 3,0 2,2 625 916 177 141 — 44,8 603 894 628 919 177 141 — 41,0 41,9
PVM 5-15 3,0 2,2 652 943 177 141 — 45,2 630 921 655 946 177 141 — 41,5 42,5
PVM 5-16 3,0 2,2 679 970 177 141 — 45,8 657 948 682 973 177 141 — 42,1 43,0
PVM 5-18 4,0 3,0 737 1053 197 147 — 54,3 715 1031 740 1056 197 147 — 50,3 51,3
PVM 5-20 4,0 3,0 791 1107 197 147 — 55,5 769 1085 794 1110 197 147 — 51,6 52,5
PVM 5-22 5,5 4,0 845 1171 220 161 — 59,8 823 1149 848 1174 220 161 — 55,8 56,8
PVM 5-24 5,5 4,0 899 1225 220 161 — 60,8 877 1203 902 1228 220 161 — 56,9 57,8
PVM 5-26 5,5 4,0 953 1279 220 161 — 62,7 931 1257 956 1282 220 161 — 58,0 58,9
PVM 5-29 5,5 4,0 1034 1360 220 161 — 64,6 1012 1338 1037 1363 220 161 — 59,7 60,6
PVM 5-32 7,5 5,5 1145 1507 235 197 300 90,1 1123 1485 1148 1510 235 197 300 84,9 85,8
PVM 5-36 7,5 5,5 1253 1615 235 197 300 92,6 1231 1593 1256 1618 235 197 300 87,1 88,1
14
Project:
Customer:
(QJLQHHU
3XPS0DQXIDFWXUHU
Contents:
'DWD6KHHWV
'LPHQVLRQDO'DWD
:LULQJ6FKHPDWLFV
)LHOG&RQQHFWLRQV
1RWH7KHGUDZLQJVLQFOXGHGLQWKLVSDFNDJHDUHIRUFRQWUROOHUVFRYHUHGXQGHURXUVWDQGDUGRIIHULQJ
$FWXDO$6%8,/7GUDZLQJVPD\GLIIHUIURPZKDWLVVKRZQLQWKLVSDFNDJH
March 2015
Technical Data
Model JPY Jockey Pump Controller
C1
T3
T3
T2
T2
T1
T1
C2 P1
T5
T5
T4
T4
T6
T6
C3
OL1
6WDUWLQJ0HWKRGReduced Voltage
:\HGHOWDRSHQ
7\SLFDO9ROWDJH$SSOLHGDW6WDUW100%
Inrush Current: 33% of normal load current
6WDUWLQJ7RUTXH33%
Motor Type::\HGHOWD
1RRI&RQWDFWRUV2 at 58%, 1 at 33% of motor FLC
0LQDPSDFLW\RIPRWRUFRQGXFWRUVDW[RI)/&
March 2015 2
Technical Data
Model JPY Jockey Pump Controller
Wye-Delta
0DLQGLVFRQQHFWURWDU\W\SHGRRULQWHUORFNHG
Open Transition
7KHUPRPDJQHWLFPRWRUSURWHFWRU
)XVHOHVV0RWRU
:\HGHOWDRSHQWUDQVLWLRQFRQWDFWRUVHW
Starter
March 2015 3
Technical Data
Model JPY Jockey Pump Controller
1RWH2SWLRQVFKRVHQIURPWKLVSDJHDUHQRWHOHFWULFDOO\UHSUHVHQWHGRQWKHZLULQJVFKHPDWLFVLQWKLVVXEPLWWDOSDFNDJH
March 2015 4
Technical Data
Model JPY Jockey Pump Controller
iPD+2SHUDWRU,QWHUIDFH
3 2
4 7
HAND AUTO
5
8
March 2015 5
0 1 2 3 4 5 6 7 8
OL1
B FU1 DS B
D
F C
XTR1
C C
Main Disconnect
G
Y
ON
R
OFF
HAND G G AUTO
G DS C3 C2 C1
B E
D D
T1
T6
T4
T5
T3
T2
Underwriters
PT1
Laboratories Inc.
LISTED
ENCLOSED INDUSTRIAL CONTROL PANEL
No. AC-XXX
DANGER
Rating
E Label E
Standard Internal Layout
Ø 8 "[9] x4
3
Dimensions*
Maximum Motor Horsepower Enclosure Dimensions Door Dimensions Anchor Dimensions
2-¼" [58]
A
H H
L1 L2 L3 PT1
Pressure Sensor
B Type 0-50mV B
G
DS G
Green
White
Y
Black
Red
R
B W G R 5 S
RESET
J5
HAND G G AUTO
PsIn-
PsOut-
PsOut+
PsIn+
OL1
C 34 33 7 C
9 IN1 J9
J21
G
IN2
OUTPUT ON J8
J19
A1
A2
OUT1 "IPD+"
D A1 D
OUT2 F5
A2
24Vdc
FU1 J2 J3 J1
XTR1
24Vac 24Vac
H2 X1 3 A2 A1
3 1 22 8
H1 X2
1
E E
C1
13 14 10 A1 A2
C1
C3
13 14
F C1
11
C3
12
F
67 68 21 22 A1 A2
C2
C1 C2
55 56 13 21 22 14 A1 A2
C3
OL1
G G
C3 C2 C1
H H
T6 T4 T5 T1 T2 T3
G
T6 T4 T5 T1 T2 T3 - Drawing for information only.
I I
Manufacturer reserves the right to modify this drawing without notice.
P1 Contact manufacturer for "As Built" drawing.
0 1 2 3 4 5 6 7 8
2015 All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.
0 1 2 3 4 5 6 7 8
B B
3 Phase
Incoming Power
Bonding Ground
C C
L1 L2 L3
DS
C2 C1
D T6 T4 T5 T1 T2 T3
D
P1
E E
G G
I I
0 1 2 3 4 5 6 7 8
2015 All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.