Reason : To communicate measures to prevent arcing from the transfer roller bushing (rear).
Details : If used in conditions where condensation occurs, there are cases where arcs can form from the
transfer roller bushing (rear) to the main drive assembly sheet metal, and in worst cases can cause
serious damage. This document will communicate service measures to prevent this from happening.
Service : An “Arc prevention cover” will be designated as a special service part. Attach this “Arc prevention
cover” in the main unit following the steps below.
<Reference>
• Symptoms where condensation has occurred
Totally black or totally white images.
• In environments where condensation occurs easily
When the main unit is cool (first thing in the morning in the winter) and peripherals have warmed
up, condensation occurs easily. If a kerosene or gas stove, or a heater in which steam occurs easily, is
being used at this time, the likelihood of condensation becomes higher.
-1/2-
6521-028
<Procedure>
1.Unplug the power supply and open the top of the main unit.
2.While pressing on the lead edge of the arc prevention cover Mylar with the fingers, attach it to cover
the transfer roller mount. Slip the tab of the arc prevention cover over the tab on the lower part of the
main unit at this time.
Service Parts :
Inter- P.C.
No. Description Part number Q’ty change- -- -- -- -- -- -- -- -- --
ability
1 Old 104
New Arc prevention cover FF5-2554-000 0→1
-2/2-