Sie sind auf Seite 1von 1

Test Certificate Page 1 of 1

Quality Assurance and Research Division Laboratory


Jl. Mayor Oking Jayaatmaja, Citeureup,
Bogor 16810, West Java - Indonesia
Tel. (+62 21) 86899902 Fax.(+62 21) 87941416

No. : 019-KAN/QARD/PCC/X/2017 Date : October 09, 2017

CEMENT TEST CERTIFICATE


Portland Composite Cement

Testing Method SNI 7064:2014 Test


Specifications Result
01/09/2017 - 30/09/2017
Physical Properties :
1 Air Content % 12 max. 8.0
2 Blaine m²/kg 280 min. 401
3 Autoclave
- Autoclave expansion % 0.80 max. 0.159
- Shrinkage % 0.20 max. -
4 Compressive Strength
- 3 Days kg/cm2 SNI 2049:2015 130 min. 185
- 7 Days kg/cm2 200 min. 251
- 28 Days kg/cm2 280 min. Curing
5 Time of Setting, Vicat Test,
- Initial Set minutes 45 min. 166
- Final Set minutes 375 max. 230
6 False set % 50 min. 75
Chemical Properties :
1 Silicon dioxide SiO2 % XRF 21.89
2 Aluminium dioxide Al2O3 % XRF 5.92
3 Ferric oxide Fe2O3 % XRF 2.77
4 Calcium oxide CaO % XRF 55.61
5 Magnesium oxide MgO % XRF 2.78
6 Sulfur trioxide SO3 % XRF 4.0 max. 1.78
7 Water-soluble Alkalies * Water-soluble % ASTM C 114 0.21
8 Ignition Loss LOI % SNI 2049:2015 7.59
9 Insoluble Residue IR % SNI 2049:2015 8.56
10 Freelime FCaO % ASTM STP 985 0.82
11 Tricalcium Aluminate* 3 CaO.Al2O3 % XRD 6.85

Remarks :
28 Days Compressive Strength, for the period August 01 - 31, 2017 is 344 Kg/cm2
Certified by,

This Laboratory is accredited by National Accreditation Body of Indonesia, KAN conforming SNI 19-17025-2000 with
registration no. LP-287-IDN. Prohibited to copy/duplicate and/or publish part of this report without permission from Quality
Assurance and Research Division Laboratory, PT Indocement Tunggal Prakarsa Tbk.

Laboratorium Penguji * unaccredited


LP - 287 - IDN

(31 - 02) 24102017.


1/1

http://itphofpenrp01.indocement.co.id/itp/erp/prd_qlt_qa_report_0126_0147_reporting_print.aspx?&doc_n... 10/24/2017