8.1 Introduction ........................................................................................................................... 2
8.2 The basic idea and generation of quasi‐constant voltage ..................................................... 2
8.3 Operation of a DC generator under load ............................................................................... 5
8.4 Different types of DC machines ............................................................................................. 8
8.4.1 Generators and motors ................................................................................................................. 8
8.4.2 Independent, shunt, PM and series excitation motors ................................................................ 12
8.5 Universal motors ................................................................................................................. 14
8.6 DC electric drives ................................................................................................................. 16
8.7 Historical notes .................................................................................................................... 20
8.8 Bibliography ......................................................................................................................... 20
8.9 Proposed exercises .............................................................................................................. 21
8.1 Introduction
Electric machines traditionally considered to be composed by the transformers and the
rotating machines.
This is justified by the fact that the transformers have a lot of physical similarities with
rotating machines: both are based on magnetic circuits made of ferromagnetic materials in which
variable flux is produced, so that EMFs are generated by Faraday’s law action.
Nevertheless, because of the reduced usage DC machines have today, the topic is dealt with
in a particularly simplified way.
This winding, called for reasons that will be presently clear, field winding, during the
machine operation is connected to a DC source and therefore is traversed by a DC current.
To analyse what happens in the machine the field winding currents can be imagined to be
flowing according to the signs indicated in fig. 8.1, i.e. they exit the page surface when a small
dot is reported in the conductors, and enter it when a cross is reported (to understand the rationale
beyond this graphical code the reader is suggested to revert to chapter 7) .
By effect of these currents, a magnetic field is created, whose force lines that flow in the
stator, traverse the small air gap, enter the rotor, traverse it then returns to the stator as
qualitatively indicated in figure 8.1.
In basic analyses of DC machines, and in this book also, the field H produced in the air-gap,
and therefore the corresponding flux density B, can be considered to be uniform. B will be
proportional to the current If circulating in the field winding
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.3
stator
S
rotor
pole tip
pole
core
S B N N B B N
air-gap S
The two machines represented in figure 8.1 differ from each-other from their pole-pairs: the
machine at the left has one pole pair, while the one at the right has two; machines can have even
more pole pairs. In all cases, all the windings are connected in series, and are thus traversed by
the same current. The analysis of the machine behaviour that will be presently propose is based
on the interaction rotor-conductors and flux density produced by the stator, and is therefore
applicable to either types of machine. Some differences between the two will be later be
discussed.
The rotor of a DC machine contains conductors at its periphery, as represented in fig. 8.2.
These conductors are inserted into the slots, that are spaces from which iron has been moved,
and are able to keep the conductors mechanically tightly connected to the basic iron structure of
the rotor.
In the electric machines terminology, the armature is the part of the machine in which an
EMF is induced by the Faraday’s law. Therefore in a DC machine the armature is the rotor. In
other machines (such as the synchronous machine, as will be seen in a further chapter) is located
in the stator.
8.4 Chapter 8: DC machines and universal motors
brush
(to get voltage
and current)
5 E5
5’
4’ E
E5’
4 E4 E4’
B
S 3 3’ N E3’
E3
2 2’
E2 E2’
1 1’ E1’
here dots indicate E1
here dots indicate field current
induced electric direction
field direction
Fig. 8:2. Generation of EMFs in the rotor, and total EMF collected by the brushes.
Each conductor moves in the uniform flux density distribution B, and has a local speed v,
whose amplitude is R (R being the rotor’s radius), but whose direction is different from one
conductor to another. On each conductor, an electric field will be generated (see sect. 7.2):
Ec v B
that will produce a potential difference on the conductor:
ec (t ) vBl vBˆ sin(t c ) (8.1)
This varies sinusoidally with time, and the angle c is specific for each conductor. The
connections of the rotor’s conductors are such that the voltage appearing on the two conductive
elements represented in black, called brushes, that are virtually connected to the two conductors
present in the direction orthogonal to the uniform field direction is the sum of the voltages
generated on half the conductors, as shown in the right part of the figure 8.2.
As far as the rotor rotates, the brushes become connected to different conductors, so that the
total voltage E reported in the right part of figure 8.2, and corresponding to the instantaneous sum
the voltages generated on half conductors (the left half or the right one can be equivalently
considered) maintains roughly always the same amplitude.
More precisely the amplitude slightly fluctuates, since it is always equal to the vertical distance connecting
the upper and lower points of the polygon shown in the right part of figure 8.2.
Considering all the conductors, and neglecting the small fluctuation of the voltage around its
average value therefore it is:
E k vBˆ1
or, considering the proportionality of v with and B̂ with If: and with the total flux produced
by the winding coil:
E k (8.2)
with
Lf I f (8.3)
and k is a dimensionless constant.
The actual connection of the brushes to the rotor is not, indeed, made directly on the rotor
conductors, but indeed these conductors are linked to a commutator, that contains conductive
segments separated by small layers of insulating material, as depicted in fig, 8.3. The conductive
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.5
elements are connected to the active conductor in the rotor periphery, creating a situation that
reproduce the principle scheme of fig. 8.2.
The collector is mounted on the machine shaft, the conductive sectors connected with the
rotor active conductors, and rotates with the rotor; the brushes do not rotate, are pressed using
suitable springs against the commutator. The brushes are constituted by a material based on
carbon, that is much softer than copper in such a way that the sliding between them and
commutator causes some wearing of the brushes instead of the commutator, This causes the need
of periodically substituting the brushes, but reduces dramatically wearing the commutator, much
more expensive to substitute.
brush
conductive
sector
insulating
material
shaft
Fig. 8.3. The basic construction of the machine commutator and its brushes.
In a reference integral with the rotor, the flux produced by the stator poles rotates, and
therefore the rotor of the machine must be laminated. the stator, instead, is subject (except for the
tips) to constant flux and does not need to be laminated. However it often happens that
manufacturers laminate all parts of their DC machines, just because if facilitates the machine
assembly or simply because eases the manufacturing process as a whole.
Ia
If If Ra Ia
+
DC + Ef +
Load Rf E U Rl
source
-
field coil
a) b)
U=E-RaIa
E
c)
Ia
Fig. 8.4. The DC generator with its field coil, their equivalent circuit and U-I characteristic
Ia sign chosen to better describe generator operation.
From the equivalent circuit of the machine also the U-I characteristic can be easily
determined, that has ideally the shape shown in fig. 8.4 c). Indeed, in case of real machines, the
non linear behaviour of the iron that constitutes stator and rotor makes the actual characteristic to
be non linear, but this is beyond the scope of this book. For small armature currents the actual
machine characteristic can be assumed to be linear.
The current flowing in the machine armature (i.e. in the rotor) will flow in the active
conductors in the rotor periphery shown in fig. 8.2.
This will produce on the rotor conductors following forces generated according to Lorentz’s
law:
F I B l
where I has as amplitude the current Ia and direction that of conductors, and l is the length of the
active conductors.
These forces will have tangential components Ft whose amplitudes will depend on their
position (fig. 8.5):
5 F
Ft
4 B
FFt
3 B
2 2’
1 1’
Fig. 8.5. Forces on the rotor conductors and their contributions Ft to torque
The set of all these forces will create globally a torque that will be proportional to the current
i and the stator flux :
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.7
T k I a (8.4)
It would be easy to demonstrate that the constant k of equation (8.4) is exactly the same that
appears in eq. (8.2). Assuming this the two equations can be multiplied to each other obtaining:
T k E / ( k ) I a
T EI a (8.5)
Eq. (8.8) is very important, since it states the basic electromechanical conversion in the DC
machine: the power inserted in the system as mechanical power T is converted into electrical
form, generating the power EIa.
To summarise, the DC machine operation can be analysed using the following equations:
E k
(8.6)
T k I a
and the equation of the electric circuit:
U=E-RaIa. (8.7)
Example 1
A DC generator runs at n=1000 RPM, supplying 200 V to an electric load. If the flux per
pole is 25 mWb, the constant k equals 90 and the armature copper losses are
300 W, calculate:
a) the electromotive force E
b) the armature current Ia
c) the armature resistance
d) the electric power Pe provided to the load
e) the torque T required to move the generator
f) the efficiency, neglecting the field losses
Ra Ia
+
+
Rl U
E -
field coil
Ia
Ra Ia If
+ T,
Main DC
U + U + + Ef
DC field E Rf
source source
-
P=T
Consider the machine to be initially still. Its connection to the sources makes a flux density B
to be created inside the machine, and an armature current to flow in the rotor active conductors.
The two interact and Lorentz’s forces are generated:
F I B l
that globally produce a torque T that will make the rotor start rotating:
T k I a
When the rotor rotates, an EMF is produced in the active conductors according to Faraday’s
law for sliding conductors:
E k vBˆ
1
that can also be expressed in more convenient terms using the (8.2):
E k (8.2)
As per the operation as a generator, the electric power EIa is converted into the mechanical
power T:
EIa=T (8.8)
The general equations of the DC machine (8.6) are therefore still valid. Also the circuit
equation (8.7) is valid, but is more conveniently written using the load sign convention:
U E Ra I a (load sign convention)
It can be concluded that the machine equations are exactly the same in generator and motor
operation, although they are usually written in a slightly different way in the two cases, as
summarised by the following fundamental DC machine equations RESULT box.
Not evidenced in the box there is also another convention: in the generator convention the reference signs for
the mechanical quantities are such that positive values of T and imply mechanical power entering or
exiting the machine in the cases of generator and load convention respectively.
When generator convention is used positive values of U, Ia imply power going from the
mechanical system into the electric one; when a load convention is used they imply
opposite power flows. Therefore generator convention is commonly used for generators
and load convention for motors.
Example 2
A 240 V DC machine with independent excitation has an armature resistance Ra= 0.2
. If the armature current is 20 A, calculate the electromotive force:
a) for generator operation
b) for motor operation.
8.10 Chapter 8: DC machines and universal motors
a) E=U+RaIa=240+0.220=244 V
b) E=U-RaIa=240-0.220=236 V
From the previous equations a torque-speed relationship for the machine is easily found, that
is of big importance for evaluating the mechanical behaviour of the machine. Consider the
equations written with the load convention. Substituting the first of them into the third yields:
U k Ra I a
and
I a U k (8.9)
Then, substituting the torque equation::
T
U k Ra
k
T k (U k ) A B (8.10)
Therefore both the armature current and generated torque are linearly decreasing curves as a
function of the angular speed , as reported graphically in fig. 8.7.
To evaluate the start-up transient of a DC machine consider the arrangement shown in the
right part of figure 8.7 in which we consider the switch S1 to be held constantly closed, in such a
way that the resistor Rs does not influence the system behaviour.
Imagine that at a given time the switch S , initially open, is closed. Let the machine and its
mechanical load have a combined moment of inertia J, and the load torque be of the type:
Tl=a+b2 .
The transient that will be activated is governed by the mechanical equation:
T Tl J
The rotor will thus accelerate from 0 to the final speed . In theory the final speed will be
reached in an infinite time, but the system will reach the vicinity of that point in a more
reasonable time, e.g. a few seconds.
At the beginning of this starting transient, torque and absorbed currents will be at their
maximums T0 and I0, respectively. the current I0 can be thought to be as a short circuit current (cf.
section 3.4.2 ), since at the very starting of the machine the two terminals of the DC source are
connected to each other and share the same potential.
Indeed often the machines cannot withstand currents as high values as I0 even for the small
period needed for acceleration, without damage. For these machines the starting operation must
be made at a reduced voltage, e.g. interposing the resistor Rs between the DC source and the
motor, just for the first part of the starting transient. In this case, in the first part of the transient
switch S1 will be held open, current and torques will have reduced values, up to the instant t*,
which corresponds to speed *, in which it is closed and the machine is fed at full voltage.
In some cases, the process is more staged: the resistor interposed is progressively reduced in value, as far as
the machine speed increases and with it also increases also the EMF E.
Some small motors, however, are designed to be started without the interposition of the
starting resistor, thus simplifying the starting process and eliminating the energy losses in the
starting resistor:
Today, large motors are more and more frequently started without starting resistor, and
without making the motor absorb the current I0, feeding they at starting with a reduced voltage:
this will be discussed in sect. 8.6.
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.11
I0 T,I S1 Ia
S
T0 Main Rs
DC
Ia source
S1 Ia
Ra S
T Tl()
Rs
+ U +
E
0
Fig. 8.7: Current-speed and torque-speed characteristics, and of starting
of an independently excited DC motor (1).
E The analysis performed here was based on a linear model of the machine.
knee
This is correct only as an approximation, since due to the non-linear
behaviour of stator and rotor iron, actual machines significantly deviate
saturated part
from linearity, when saturation occurs. The main deviation from linearity
in the relationship between the field current If and the generated EMF, as
linear part indicated in the figure aside.
In real machines, however, the actual excitation operating point is held in
If the linear zone, or at most at the knee, since going further would increase
excitation losses without increasing the EMF.
Example 3
A DC motor with independent excitation is supplied with 240 V, the flux per pole being
30 mWb and the armature resistance 0.5 . If the motor develops a torque T=45 Nm
and the constant k= 85, calculate:
T 45
Ia 17.65 A
k 85 0.03
E U Ra I a 240 0.25 17.65 231.2 V
E 231.2
= 90.66 rad/s 865.7 RPM
k 85 0.03
Pm T 4080 W
Pel U I a 4235 W
Pm
= 0.963
Pel
1
It will be soon shown that approximately the same curves apply also in the cases of shunt and PNM- excited
machines.
8.12 Chapter 8: DC machines and universal motors
field coil
a) b) c)
Ia=If RTh
+
DC DC + ETh
source source
Uf e)
-
d)
Fig. 8.8. Some options for excitation of DC machines:
a) independent (or separate); b) shunt; c) permanent magnet; d) series.
In figure a) the excitation is independent (or separate,) as discussed in the previous section.
In figure b) the supply to the field coil is the same source that feeds the armature. This is
called shunt excitation. In case the DC source is ideal, i.e. with zero internal resistance, this
solution is perfectly equivalent to the one of independent excitation.
In case of a non-zero inner (or Thevenin) resistance of the DC, a (often minor) difference comes from the fact
that when the machine absorbs a very high current Ia, the voltage Uf feeding the field coil If is significantly
lower than ETh. thus, with shunt excitation a high armature current tends to reduce the field current.
Therefore, except for minor differences, the voltage-current and torque-current characte-
ristics are the same as reported in the previous section for the case of independent excitation.
In figure c) the field is not created by an actual coil, but by the insertion of permanent
magnets in the stator circuit. Their effect is, as discussed in chapter 7 , to create a fixed field flux
, exactly in the same way as if a fixed current flowed in an excitation coil. Therefore PM
excitation is equivalent to independent excitation, and as the latter it is nearly equivalent to shunt
excitation.
Some important, though obvious, differences about these types of excitations are:
independent excitation requires an independent DC source; it allows easy modification of If,
acting on the value of the voltage applied to the field coil;
shunt excitation is cheaper than independent excitation, since does not require an external
energy source; modification of If is possible inserting in series with the coil an additional
resistance, so that at equal voltage applied to the series the total resistance is increased and If
reduces;
PM excitation allows easy and robust machine construction, but does not allow flux
modifications. It is typically used in small DC motors.
Finally, in figure c), the field winding is connected in series with the machine armature.
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.13
The voltage-current and torque-current characteristics are easily determined combining the
machine equations (8.8) and the excitation equation Lf I f Lf I a .
If the symbol Lm is used to indicate the product kLf, it therefore will be:
E k kLf I a Lm I a
T k I a kLf I a I a Lm I a
2
and:
U E Ra I a kL f I a Ra I a ( L fa Ra ) I a
Thus
U2
T Lm
Lm Ra 2
The resulting shape, drawn considering Um=const, is summarised in fig. 8.9. Starting from
the value T0=LmU2/Ra2 at standstill, degreases continuously as increases, always being positive.
At large speeds the term Ra in the denominator can be neglected and the curve decreases
proportional to 1/2.
The stand-still current I0 (and the standstill torque T0) is normally too high and can cause
damage to the machine. Therefore, the machine is started at a reduced voltage, and the reduction
is obtained at low speeds by interposition of a starting resistor Rs, that is then bypassed when the
current has become acceptable, in correspondence to the speed * (the curve of I0 when S1 is
open is not reported in the current plot just to avoid too many curves on the same plot).
S1
T,I S
Ia=If
I0 Rs
DC
source
T0
1/2
Fig. 8.9: Current-speed and torque-speed characteristics, and of starting of a
series-excited DC motor.
Series excited machines are used when the load might have sudden peaks of torque: in this
chase this machine slows down, and rises its torque by large amounts, thus overcoming the
difficulty.
It was widely used in the past onboard trains, mainly because of its high torque capability at
low speeds, even though starting of trains was made using the temporary insertion of series
resistances (such as the Rs if figure 8.9).
Today they are used as small motors, often sized to be able to start without Rs, and as the
Universal motor, that will be discussed in section 8.5.
8.14 Chapter 8: DC machines and universal motors
Example 4
A 300 V DC shunt motor absorbs 35 kW from the electric grid. The field and armature
resistances are respectively 120 and 0.15 . Calculate:
a) the line, armature and field current
b) the electromotive force
c) the efficiency
d) the motor speed, if the flux per pole is 30 mWb and the constant k equals 80
e) the torque developed
Pel 35000
I 116.7 A (line)
U 300
U 300
If 2.5 A (field)
R f 120
I a I I f 114.2 A (armature)
E U Ra I a 300 0.15 114.2 282.9 V
Pm E I a 32295 W
Pm 32295
= 0.923
Pel 35000
E 282.9
117.9 rad/s 1122 RPM
k 0.03 80
T Pm / 274 Nm (also k I a )
The reader can verify that losses (Pel-Pm) equal RaIa2+RfIf2.
Example 5
A 240 V DC series motor has an armature resistance Ra=0.4 and a field resistance
Rf=0.12 . If the motor runs at 900 RPM absorbing 30 A, calculate torque and
efficiency.
E U ( R f Ra ) I = 224.4 V
n
= 2 94.25 rad/s
60
Pm E I 6732 W
T Pm / 71.43 rad/s
Pm
= 0.935
UI
Ia=If
Ra Rf Ia
+
T,
DC + U +
U E
source
- P=T P=EIa
Fig. 8.10. Series-excited DC motor with indication of electric and mechanical reference signs.
Moreover, consider and the usual general equations of DC all motors (8,8):
E k
U E Ra I a
T k I a
In case of series excitation, being Lf I a the same equations become:
E Lm I a
U E Ra I a
T Lm I a
2
In case the actual polarity of the supply voltage is opposite to the reference signs reported in
fig. 8.10, it will be:
E<0 Ia<0 >0 T>0 P=EIa=T>0
This indicates that in case of reversal of the supply polarity, the machine continues to rotate
in the same direction, and the electric circuit will continue to transfer power to the mechanical
part of the machine.
Indeed it must be noted that all the equations that have been written in the previous section,
did not take into account the possibility of dynamical variation of the quantities, in particular of
the current Ia=If. In case the machine is connected to an AC source, instead, this current will
continuously change, and this will introduce significant changes in the machine behaviour, since
the machine has inner inductances and current flowing into inductors cause electromotive forces
to be generated:
dI
UL L .
dt
2
Sometimes they are also called AC commutator motors.
8.16 Chapter 8: DC machines and universal motors
The higher the frequency applied to the universal motor, the more its operation will be
different from the DC characteristics. For instance the torque-speed relationship of the same
machine operating at different frequency is qualitatively represented in fig. 8.11.
In a recent past, when electric trains were typically operated using commutator motors, very large AC
commutator motors were used: up to hundreds of kilowatts. To have the advantage of AC feeding (that
allowed used of transformers to feed the contact lines), and minimise the disadvantages connected to the
effect of machine inductances traversed with fast variable currents, a lot of railway contact lines were built
that operated at a frequency that is lower than the one typically used for stationary applications: 25 Hz in
some American states, 50/3=16+2/3 Hz in some European countries. In Europe there still exist thousands of
kilometres operated at 162/3 Hz, even though modern trains innerly convert electricity first in DC, and then
supply a power trains that typically are based on synchronous or induction motor drives.
T
Railway frequency:
DC 16,67Hz; 25 Hz
Railway Stationary frequency:
freq 50 Hz, 60 Hz
Stationary
freq
Fig. 8.11: Universal motor torque behaviour at different frequencies.
Small universal motors are today very frequently used in small domestic appliances, where
simple construction and high torque at small speeds are requested. therefore, typical application is
in drills, food mixers, saws, vacuum cleaners. Characteristic of these motors is a high noise and
small arcs in the commutator: both are mainly due to the continuous switching of current
between the armature conductors, commanded by the switching of brushes from a commutator
sector to another.
Needless to say, universal motors must be always laminated in both stator and rotor.
In recent years, new devices called electronic converters have appeared that allow very
flexible and effective modification of the characteristic of supply, and allow much easier and
effective matching of machines to their supply system.
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.17
Therefore we can insert between the source and the machine of the converter so that the
voltage and current the machine sees are different from those at the interface with the DC source
(fig. 8.12a) This is normally done when a cheap DC source is available to feed the converter, e.g.
in a system in which the main source us an electrochemical battery3. In the majority of cases,
however an AC source is easily available. For powers larger than just a kilowatt this is typically a
three-phase source, as reported in fig. ## b.
Is Im
+ + T,
DC Electronic Um a)
Us
source converter
- -
Electric drive
Ia
+
Im
Uc
Uab + T,
Ic
AC - Electronic Ua
source
Um b) Ib
converter Uab
-
Ia
Electric Ub
drive
The general purpose of the electronic converter is to modify the parameters of the electricity
supply, ideally leaving the power unchanged. In case the main source is DC the following
equation will ideally apply:
P=UsIs=UmIm (8.11)
In case in which the source is three-phase AC, indicating with the symbols Ul and Il the RMS
value of the line-to-line voltages and line currents respectively, and with cos the power factor
(phase displacement between phase voltage and phase current) it will be:
P 3U l I l cos U m I m (8.12)
Obviously enough, it will not possible to realize the exact equivalence of input and output
power, because, to make voltage and current conversion some power loss would unavoidably
occur. For the purpose of basic analysis of electric drives, these losses can be initially neglected:
they are considered only at a later stage to evaluate global efficiencies. Therefore in this section
(8.11) or (8.12) will be assumed to be satisfied.
Actual electronic converters ca have very high efficiencies. It is not uncommon to have efficiencies4 of
around 97-98%:
A converter realising the basic equation (8.11) is called DC-DC converter or chopper. It
performs in a much same way as an ideal transformer: it is like the transformer, but operating in
DC.
3
This is for instance the case of some Italian submarines: submarines are indeed often fed by electrochemical
sources, because when submerged they cannot consume the oxygen combustion-based engines require.
4
The efficiency of a converter will be computed as the ratio of output and input power: =UmIm/(UsIs).
8.18 Chapter 8: DC machines and universal motors
The ratio between output and input voltage, and between input and output current:
=Um/Us=Is/Im
can be set by a control action on the inner operation of the converter, differently from the
transformer, in which this ratio is fixed because it equals the turns ratio.
A converter realising the basic equation (8.12) is called AC-DC converter or rectifier.
Rectifiers can be realised in different ways in practice. To obtain an effective drive, a
controlled rectifier is need, e.g. a system only is able to transfer power from an AC source to a
DC load in a controlled way.
So, again, the ration of input and output voltages and currents can be set by a control action
on the inner operation of the converter:
=Um/Ul =Is/Im
Some information of the inner structure and operation of electronic converters in general, and DC-DC
converters in particular, will be provided in part III of this book . i
A second electronic converter can be used to vary the voltage applied to the field coil, so that
the field current If=Uf/Rf is modified according to the needs. The arrangements in this case can be
of the type reported in fig. 8.13,
Im
If
DC/DC + DC-DC
DC converter Um converter a)
source
(1) - (2)
Im
If
Controlled + Controlled
AC rectitier Um rectitier b)
source
(1) - (2)
Fig. 8.13. Electric drives with controlled armature and field voltages:
a) starting from a DC source ; b) starting from an AC source.
It is important to evaluate the maximum torque and power performance of an electric drive
of the type shown in figure 8.13. this can be easily done considering the fundamental equations of
the DC motor (8.8):
E k
T k I a
U E R I
a a
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.19
considering that the machine will have maximum values of armature voltage and current Umax
and Imax, that cannot be overcome, and that in normal operation it can be assumed UE.
Consider the machine operation starting from standstill, with growing speed . In the
beginning the field flux is held equal to its maximum value. The armature voltage will be
approximately linearly growing with , because it is assumed to be approximately equal to the
machine EMF E (fig. 8.14). Correspondingly the maximum torque available will stay at the fixed
value T k I max . There is a speed, that is called base, at which the maximum voltage has
reached its maximum value Umax and cannot therefore further increase.
The machine speed can further increase over base, maintaining the armature voltage
constant. This can be done by reducing the flux : this is the field weakening region, that can
continue up to the point in which the maximum machine speed max is reached.
Note that this behaviour allow to exploit the maximum torque the machine is able to deliver
up to the point in which the machine has reached its maximum power; starting from that point the
machine is able to deliver its maximum power up to the maximum allowed.
flux torque
voltage power
a) b)
Obviously, the drive is able to make the machine deliver torque and power that are lower
than the limit values reported in fig. 8.14: it is just a matter of making the machine absorb
currents that are lower than Imax. Controlling the drawn current is easy done. Consider the
equation:
U E Ra I a k Ra I a
in which, at given flux , E varies slowly since its variation is connected with the mechanical
inertia of the machine rotor and its mechanical load.
Any variation in the applied armature voltage U, will therefore result in a corresponding
variation of the drawn current:
U E
Ia
Ra
and therefore of the torque produced:
T k I a
The usual rule for controlling the DC drive is to keep the flux at its maximum (function of
as indicated in figure 8.14) controlling the field current acting on the field electronic converter,
and to vary the armature current (and therefore torque) acting on the applied voltage through the
armature electronic converter.
8.20 Chapter 8: DC machines and universal motors
For further information on DC electric drives the reader is recommended to consult the book
[1].
8.8 Bibliography
[1] N. Mohan, T. M. Undeland, W. P. Robbins, Power Electronics, 3rd edition, John Wiley & sons, 2003.
M. Ceraolo - D. Poli: Fundamentals of Electrical Engineering 8.21
8.1. Calculate the voltage induced in the armature Nm, where is the angular speed of the motor.
of a DC machine running at 1500 RPM, if the flux
per pole is 30 mWb and the dimensionless 8.8. A 400-V DC shunt motor has field and
constant k equals 120. armature resistances of respectively 100 and 0.1
. If the motor absorbs 40 kW from the electric
8.2. The DC generator of the previous exercise has grid, calculate:
an armature resistance of 0.4 and supplies a a) the line, armature and field current
load of 12 . b) the electromotive force
Calculate: c) the efficiency
a) the armature current
b) the voltage applied to the load 8.9. The 400-V DC motor of the previous exercise
c) the electric power provided to the load is running at 1100 RPM and absorbing a line
d) the torque and the mechanical power required current of 80 A. Calculate the torque developed
to move the generator and the efficiency.
8.3. A separately excited four-pole DC generator 8.10. A 230-V DC shunt motor, with an armature
runs at 1500 RPM, supplying 240 V to a certain resistance of 0.4 and a field resistance of 200 ,
load. The flux per pole is 20 mWb and the absorbs 2.5 A in no-load operation. In another
constant k equals 85. The armature copper loss is loading condition, the same motor runs at 300
600 W and the total brush-contact drop is 2 V. RPM while absorbing 30 A. Calculate the no-load
Calculate: speed.
a) the electromotive force
b) the armature current 8.11. A 400-V DC series motor, with an armature
c) the armature resistance resistance of 0.3 and a field resistance of 0.15
d) the electric power provided to the load , absorbs 40 A. If the motor runs at 800 RPM,
e) the torque required to move the generator calculate the torque and the efficiency.
8.4. A 200-V separately excited DC machine has 8.12. A 230-V DC series motor, with a total
an armature resistance of 0.3 . If the armature circuit resistance of 0.45 , absorbs 40 A while
current is 24 A, calculate the electromotive force: running at 600 RPM. Calculate the speed when the
a) for generator operation motor absorbs 30 A and the torque in both
b) for motor operation. conditions. Compare 1/2, I1/I2, T1/T2.
8.5. A 250-V shunt generator provides 5 kW to a 8.13. A 230-V DC series motor, with a total
certain load. The armature and field resistances circuit resistance of 0.5 , absorbs 20 A while
are respectively 0.5 and 200 . Calculate the running at 800 RPM. Calculate the motor speed
armature and field currents, the electromotive when the torque is reduced by 30%.
force and the torque required to move the
generator, if it runs at 1200 RPM.