ELEVATOR SYSTEM

CONTROL
FEATURES PURPOSE CONTROL PRINCIPAL
METHOD

1. The system which


manages automatically
oil pressure and flux,
caused by the change of - Freight and car
load. elevator
2. Minimization of - Parking building,
HYDRAULIC motive electric currents storage, hospital and
CONTROL by choosing invert and factory
realization of the - Low speed
decrease to 30% of (30,45,60M/Min)
power resources. Micom
3. Easy repair and exact
installation are
advantages.

1. Management by
Micro-computer
- Suitable for
2. Easy repair thanks to
passenger
making trouble place.
- Medium sized
3. Enlargement of
MICOM structure, such as
installation and machine
CONTROL medium and small
room by the minimized
sized building, hotel,
control box
department store, and
4. Realization of the
so on
energy-saving
technology to 50%

- Suitable for
1. Control method of passenger
frequency change - Medium and large
2. In speed reduction, sized structure, such
the decrease to 20% of as medium and small
WVF supply power sized building,
CONTROL 3. Comfortable and apartment, hotel,
silent department store, and
4. The load decrease to so on
50% of the power - Medium, and high
resources speed (60,90,105,120
M/Min)
│ Various Functional Characteristic │
 Stop on each floor
 Manual operation
 Operation to the designated floor (for private)
 Relief operation
 Installed the vocal guiding device
 Measuring
 Perception of the high temperature
 Manually operated by operator
 Control operation in earthquake
 Single automatic/riding together operation automatically
 Automatically parking
 Control operation in fire
 Operation by machine room
 Automatic leveling revision
 Standby status program on the particular floor
 Choosing the floor without stop
 Perception of the low temperature
 Power resource device without electric interruption
 Cancellation of the mischievous calling
 Simple observation
 Operated by the fire fighter
 Inputting the over a fixed number
Various Safe Devices In Elevator

 Circuit breaker:Circuit breaker Device which protects machine from excess current
 Door lock switch:Except for a case that the elevator reaches the expected floor, the door never opens.
 Wedge:Device, installed in the lower part of the car and which stops safely the car by catching guide rail
 Governor:In a case that the car speed goes beyond the safe speed, governor interrupts the motor’s power,
and operates the wedge by catching rope
 Magnetic brake:In a case of motor stop, magnetic brake stops the elevator through catching the braking
plate by the power of spring
 Outside door latch:Device to rescue the passenger inside the car, in interruption of electric power or
emergency
 Safety shoe:If there is something between gates, safety shoe checks the thing and reopens the gates.
 Buffer:If the car or count weight falls to the lowest floor, buffer safely stops them.
 Fascia plate:Device, to cease passengers from falling between the wall of lift wall and the car.
 Limit switches / upper and lower:Ceasing the car from operating above normal positions in highest and
lowest floors
 Final limits switches/ upper and lower:Dual safe device of the limit switches, finally ceasing the car
from operating above the normal position in the highest floor.
 Rope Brake:If the car operates in the state of opened gates or slides down without control or operates above
normal speed, the rope brake safely stops the car.
 Emergency exit:Device, which is installed in the upper part of the car and makes the passenger inside the
cage escape.
 Emergency light:The light automatically turned on, to brighten the inside of the car in interruption of electric
power.
 Inter-phone:Device, which can make the passenger call to the outside in emergency.
 Weighing device:Device, preventing the excessive passenger (freight) from boarding.