Sie sind auf Seite 1von 6

7PJ15 – Trip Relay

High Speed Tripping


s
7PJ15 - TRIP Relays Nominal Burdens

OPERATE COIL BURDEN (W)


Rated voltage V DC 10 contacts 20 contacts
125 ~ 130 ~ 170
240 ~ 170 ~ 170

RESET COIL BURDEN (W)


Rated voltage V DC 10 contacts 20 contacts
125 < 50 ~ 70
240 ~ 70 ~ 130

Contact Ratings

Make and carry 1250 VA AC or 1250 W DC within limits of


continuously 660 V and 5 A

Make and carry for 3 s 7500 VA AC or 7500 W DC within limits of


250 V and 30 A

Break 1250 VA AC or 100 W (resistive) DC or


50 W (inductive) DC within limits of 250 V
and 5 A

Description Environmental Test

7PJ1524 High Speed Trip relay is a multi-contact attracted


Temperature
armature relays designed to IEC 60255-1.
IEC 60068-2-1/ IEC 60068-2-2
- High speed, high burden, positive action, instantaneous
cutoff. Operating -10°C to +55°C
- Supervising Trip Relay Coil Storage -25°C to +70°C
- 7PJ1524 trip relay allows to use the Trip Circuit
Supervision relay (7PJ13) to monitor and supervise the
Humidity
integrity of trip circuit with coil supervision terminal.
IEC 60068-2-30/IEC 60068-2-78
- Supplied in draw-out type case.
- Robust design for a long, reliable service life. Damp heat test, Cyclic 6 days at 250C to 400C and 93% relative
humidity
High burden, Trip Relay Series Maximum Altitude of Up to 2000 m
High burden relays with immunity to capacitance discharge Operation
currents. These relays are suitable for applications where
they are located remotely from the initiation signal.

Mechanical Test
Technical Data
Test Reference Requirement
Technical Data Overview
Vibration IEC60255-21-1 Response Class I
Operating time 10 ms at rated voltage Shock and Bump IEC60255-21-2 Shock response and
withstand Class I,
Reset time < 20 ms at rated voltage VN Bump Class I

Rated voltage VN 125 V, 240 V DC Seismic test IEC60255-21-3 Class I

Degree of protection IEC60529 IP50 – Front


Operating range 50% to 120% of rated voltage
IP20 – Rear
Contacts Hand reset and Electrical reset IP40 – Side

Flag Hand reset Electrical Endurance IEC 60255-1 10,000 operations


at the rate of 600
All operate and reset coils are short time rated well in excess operations per hour at
of the operating time of their cut-off contacts. 250 V AC, 5 A
(Ref: Std IEC 61810-1)

2
Product Safety Test Ordering Information – 7PJ15

Test Standard The following are the high speed trip relay variants, high
• Clearances and Creepage Distances Test IEC60255-27
burden with contact type (Hand Reset + Electrical Reset) and
hand reset flag.
• IP Rating Test
• Impulse Voltage Test MLFB Ordering Code Rated Contacts Configurations
• AC or DC Dielectric Voltage Voltage
• Insulation Resistance
7PJ1524-1JC60-1AF0 125 V DC 10 Contact (8NO+2NC)
• Protective Bonding Continuity
• Flammability of insulating materials, 7PJ1524-1JC60-1AH0 240 V DC 10 Contact (8NO+2NC)
components and fire enclosures
7PJ1524-1GE60-1AF0 125 V DC 10 Contact (6NO+4NC)
• Single-fault Condition

• Mechanical resistance to shock and impact IEC61010-1 7PJ1524-1GE60-1AH0 240 V DC 10 Contact (6NO+4NC)

• Protection against electric shock 7PJ1524-1GA60-1AF0 125 V DC 6 Contact (6NO)


• Protection against the spread of fire
7PJ1524-1GA60-1AH0 240 V DC 6 Contact (6NO)
• Equipment temperature limits and resistance
to heat
7PJ1524-1FB60-1AF0 125 V DC 6 Contact (5NO+1NC)

7PJ1524-1FB60-1AH0 240 V DC 6 Contact (5NO+1NC)

7PJ1524-1EC60-1AF0 125V DC 6 Contact (4NO+2NC)


Electrical Tests
7PJ1524-1EC60-1AH0 240 V DC 6 Contact (4NO+2NC)

7PJ1524-1UC80-1CF0 125 V DC 20 Contact (18NO+2NC)


Test Standard
7PJ1524-1UC80-1CH0 240 V DC 20 Contact (18NO+2NC)
Insulation Resistance IEC 60255-27#
500 V DC, >100M Ohms 7PJ1524-1SE80-1CF0 125 V DC 20 Contact (16NO+4NC)
Between all terminals & earth
Between coil terminals & contacts 7PJ1524-1SE80-1CH0 240 V DC 20 Contact (16NO+4NC)

Impulse Voltage Withstand IEC 60255-27#


5.0 kV, 1.2/50 μs, 0.5J
Between all terminals & earth
Between coil terminals & contacts

High Voltage (Dielectric) IEC 60255-27#


2 kV, 50 Hz@1min (2.2 kV for 1 s)
Between all terminals & earth
Between coil terminals & contacts
1 kV AC RMS for 1 min
across normally open contacts

Thermal Withstand IEC 60255-6


Continuous 1.2 VN

Thermal withstand for 10 s IEC60255-6


1.30 VN

Functional IEC 60255-1

Maximum Allowable IEC 60255-6


Temperature Max. temperature limit +1000C

AC Ripple on DC supply IEC 61000-4-17


Withstand 15% AC ripple on DC

Power Frequency Magnetic IEC 61000-4-8 Level 4,


Field Immunity 30 A/m applied continuously
300 A/m applied for 3 s

Switching Rate 600 Operations per hour

Immunity to capacitance ENA TS 48-4


discharge Issue 4 2010, Table 1*

# NOTE: All aspect of IEC 60255-5 have been covered under IEC 60255-27.
* NOTE: 10 Contacts-240 V DC and 20 Contacts-125 V, 240 V DC product
variants is not part of the ENA TS 48-4.

3
Dimensional Drawings

E2 Casing

Front view with front cover Side view with front cover attached Terminal numbering from rear

E4 Casing

Front view with front cover Side view with front cover attached Terminal numbering from rear


E2 Panel Cut-Out E4 Panel Cut-Out

4
Wiring Diagrams

10 / 6 Contacts Wiring Diagram

20 Contacts Wiring Diagram

5
Siemens Limited Siemens Limited
Energy Management Energy Management
Energy Automation Energy Automation Works
Plot No. 6A, Sector 18 Plot No. L-6, Verna Industrial Area
Maruti Industrial Area Huda Panaji - Margao Road,
Gurgaon - 122015, India Verna - 403722, Goa
Phone: +91 124 3836000, 3837362 Phone: +91 832 3993000
Fax: +91 124 3836261 Fax:+91 832 6723299
Email: energyautomation.marketing.in@siemens.com

C53000-X7040-C005-4
EM-EA-7PJ1524-004

For any technical queries, please contact our customer support center
Siemens Limited
Energy Automation Works
Plot No. L-6, Verna Industrial Area
Panaji - Margao Road,
Verna - 403722, Goa
India
Phone: +91 832 6723151
+91 832 6723165
Fax: +91 832 6723299
E-mail: EAsupport.in@siemens.com
Subject to change without notice, Printed in India.

Das könnte Ihnen auch gefallen