analyzed od Chemicals
Chloroform 99.8%
Trahydrofuran 99.9%,
n-hexane
Hydrochloric acid
Heptadecanoate
MSTFA
Glycerin
Mono-olein
Di-olein
Triolein
Ricinolein
Tricaprin 99%
Oleate
Palmitate
Linoleate
Stearate
Linolinate
Acetonitrile
Acetone
Commercial TAG
standard
Tocopherol analysis HPLC Hplc system consisting of a high pressure pump, a Alfa,beta,gama and sigma
(ISO 9936) sample injection device, column thermostat adjusted tocopherol and tocotrienol
to 25oC(optional), afluorescence detector with the standard(a blend of wheat germ
excitation waveleght set at 295nm and emission
and soya bean oil may be used
waveleght at 330nm, and a recording monitor
instead)
A UV detector may be used but it is not
recommended If tocotrienol std is not
available(palm oil may be used)
HPLC analytical column(two type are possible)
250mm x 4mm, packed with microparticulate diol Tetrahydrofuran,filtered through
having a mean particle size of about 5micrometer an hplc nylon filter (0.45microM)
OR
250 x 4.6mm, packed with microparticulate silica n-heptane filtered through an
having mean diameter of about 5micometer
hplc nylon filter (0.45microM)
Uv spectrometer capable of absolute measurement
HPLC mobile phase(solvent that
oof absorbance at precisely define wavelength,with
a 10mm path cell. has been approved to reach
chromatographic resolution of
Rotary evaporator peaks.(relative retention time of
tocopherol and tocotrienol)
Graduated cylinder, of 1000ml capacity
Methanol
Volumetric pipettes, of 5ml, 10ml and 20ml
capacities
Analytical balance
Standard Test Inductively- Spectrometer—Either a sequential or simultaneous Base Oil, U.S.P. white oil, or a
Method for Coupled Plasma spectrometer is suitable, if equipped with a quartz lubricating base oil that is free of
Determination of Atomic Emission ICP torch and r-f generator to form and sustain the analytes, with a viscosity of about
Additive Elements in ICP-OES plasma. 4 cSt at 100°C.
Lubricating Oils by
Inductively Coupled Analytical Balance, capable of weighing to 0.001 g Internal Standard, (Required)—An
Plasma Atomic or 0.0001 g, capacity of 150 g. oil-soluble internal standard
Emission element is required. The following
Spectrometry (This Peristaltic Pump, (Recommended)—A peristaltic internal standards were
test method covers pump is strongly recommended to provide a successfully used in the
the quantitative constant flow of solution. interlaboratory study on precision:
determination of Ag, Be, Cd, Co (most common),
barium, boron, The pumping speed must be in the range 0.5 to 3 La, Mn, Pb, Y.
calcium, mL/min.
copper, magnesium, Organometallic Standards—Multi-
phosphorus, sulfur The pump tubing must be able to withstand at least element standards, containing
and zinc in unused 6 h exposure to the dilution solvent. Fluoroelastomer known concentrations
lubricating oils and copolymer tubing is recommended. (approximately 0.1 mass %)
additive) of each element, can be prepared
Solvent Dispenser, (Optional)—A solvent dispenser from the individual metal
calibrated to deliver the required weight of diluent Concentrates.
can be advantageous. Ensure that solvent drip does
not affect accuracy. Dilution Solvent—Mixed xylenes,
o-xylene, and kerosene
Specimen Solution Containers, 30 to 120 mL, glass
or polyolefin vials or bottles, with screw caps.