HF-Selectalume II for TL-D

lamps
HF-S 236 TL-D II 220-240V 50/60Hz

HF-Selectalume II TL-D is the most cost-effective, reliable and


outstanding solution for fluorescent lamps. These ballasts are part of
an overall high-efficiency lighting system that may help you or your
customers to achieve any international or local energy code you need
to comply with. HF-Selectalume II TL-D ballasts are the ideal choice
for a broad range of new construction and retrofit applications within
the commercial sector, including general surface mounting or office
lighting, parking garages, warehouses, waterproof and other
applications.

Product data

• General Characteristics Max ballast on 28 x


MCB(16A type B)
Application code II
Crestfactor 1.7 -
Rated Lamptype TL-D
Hum and Noise level < 30 dB(A)
Rated Number of 2 piece
Lamps
Rated Ballast-Lamp 36 • Wiring Characteristics
Power
Cable-Cap output- 200 (max) pF
Line Voltage 220-240 V
wires mutual
Line Frequency 50/60 Hz
Conn.type input WAGO 744 connector
Housing L 280x30x28
terminals
Energy Efficiency A2 BAT
Conn.type output WAGO 744 connector [Suitable for
Index
terminals manual wiring]
Lifetime 90% 50000 hr
Max. cable length 0.75 m
surv.@Tcaselife
Hot Wires
Striplength 8.0-9.0 mm
• Operating Characteristics Dual fixture Master/ Possible, lamp wires 2m max. length
Slave [Master/Slave operation possible]
Automatic restart Yes
Wcs Input terminals 0.50-1.50 mm2
Preheat time 1.6 s
Wcs Output termi- 0.50-1.50 mm2
Operating frequency 45 kHz
nals
*
Cable-Cap hot out- 200 (max) pF
Mains voltage safety 198-264V -10%/+10%
wires-earth
(AC)
Cable-Cap cold out- 200 (max) pF
Mains voltage 202-254V -8%/+6%
wires-earth
performance (AC)
Inrush current Peak 18 (max) A
Inrush current Width 0.35 ms • System Chars on driver level
Earth leakage current 0.5 (max) mA
Rated Lamp Power 36
Power losses gear 4.6 W
on TL-D
Ballast Lumen Factor 1.01 -
System Power on TL- 71.2
PowerFactor 100% 0.98 -
D
output power
Lamp Power on TL- 66.6
Overvoltage protec- 48 hr
D
tion 320Vac
Power Loss on TL-D 4.6
Overvoltage protec- 2 hr
tion 350Vac
HF-Selectalume II for TL-D lamps

• Temperature Characteristics • Approval & Application Chars


F-marking Yes EMI 9kHz .. 30 MHz EN 55015
T-case life 75 C Vibrations IEC 68-2-6 Fc
T-case maximum 75 (max) C Bumps IEC 68-2-29 Eb (10G/16ms)
T-ambient -20 (min), 55 (max) C Approval marks CE / CCC / ENEC / VDE-EMV
T-storage -40 (min), 80 (max) C CE marking Yes
ENEC certificate Yes
C-Tick certificate Yes
• Emergency Characteristics
CCC certificate Yes
Bal Lm Fac Emer- 0.7 - PSB certification Yes
gency operation TISI marking Yes
Light output after 5 50% of EBLF SIRIM approval Yes
sec CB Certificate Yes
Light output after 60 100% of EBLF
sec
• Product Data
Normal operating 220-240 V
voltage (DC) Order code 913713032466
Batt volt guaranteed 186-275 V Full product code 913713032466
ignition Full product name HF-S 236 TL-D II 220-240V 50/60Hz
Batt volt guaranteed 176-275 V Order product name HF-S 236 TL-D II 220-240V 50/60Hz
operation Pieces per pack 1
Packing configuration 12
Packs per outerbox 12
• Product Dimensions
Bar code on pack - 8711500999313
Length A1 280 mm EAN1
Fixing Hole Distance 265 mm Bar code on 8727900905533
Length A2 outerbox - EAN3
Width B1 30 mm Logistic code(s) - 913713032466
Height C1 28 mm 12NC
Fixing Hole Diameter 4.2 mm Net weight per piece 0.193 kg
D1

Dimensional drawing

HF-S 236 TL-D II 220-240V 50/60Hz


Product A1 (Norm) A2 (Norm) B1 (Norm) C1 (Norm) D1 (Norm)

HF-S 236 TL-D II 220-240V 280 265 30 28 4.2


50/60Hz

1
2
HF-S II 3
13 4
BALLAST
12 ~ 5
11 ~ 6

2 Lamps

2015, August 29
data subject to change
HF-Selectalume II for TL-D lamps

Photometric data

Ballast type

HF-S 236 TL-D II 220-220V 50/60Hz

© 2015 Koninklijke Philips N.V. (Royal Philips)


All rights reserved.

Specifications are subject to change without notice. Trademarks are the property of
Koninklijke Philips N.V. (Royal Philips) or their respective owners.

www.philips.com/lighting 2015, August 29


data subject to change