Services, Wärtsilä Finland Oy
Engine section Engine type Ref. Date Issue Document No. Page
21 Starting air system W20 WFI–S 14-Nov-2012 01 2021T023 1(3)+1
Solution To prevent re-engaging the air starter when the bendix is still spinning a
timer can be installed. The timer will prevent unintentional re-engaging of
the air starter for 30 seconds after the previous start attempt. This ensures
that the air starter bendix have stopped rotating before another start attempt
is made.
WÄRTSILÄ® 20 engines manufactured from July 2011 and Auxpac 20
engines manufactured from January 2012 have the same function
integrated and are thus not covered by this letter.
Recommendation It is recommended that the solution with the timer as described above is
installed to prevent re-engagement damage on the flywheel gear rim. See
the instructions on the next page.
Wärtsilä Finland Oy P.O. Box 252 (Tarhaajantie 2) Telecop. +358 10 709 1847 Tel. +358 10 709 0000 Business ID 0773744-3
Services, Vaasa FIN-65101 Vaasa, Finland Telecop. +358 10 709 1380 Registered Office: Vaasa
Wärtsilä Finland Oy P.O. Box 50 (Stålarminkatu 45) Telecop. +358 10 709 3279 Tel. +358 10 709 0000
Services, Turku FIN-20811 Turku, Finland Telecop. +358 10 709 3410
Services, Wärtsilä Finland Oy Technical Bulletin
Issue Document No. Page
01 2021T023 2(3)+1
Instructions Fit the timer in the cabinet on the engine by drilling a hole and fastening it
with a screw and lock nut. The electrical connections are to be made
according to the attached wiring diagram.
Ordering Contact your closest Wärtsilä Services Network. When ordering, please
specify the engine serial number and part number.
START SOLENOID
MCM K321 CV321
RTFRO 2 x 1.5 mm²
3 1 Black 1.5 mm² 2
MCM-1-X35-1 Blue 1.5 mm² 2+
MCM-1-X35-2 2 2 1 1-
X_CV321
DIN 43650
SPEMOS
SPEMOS K321
7 PART OF CABLE C
70 3 1
98 X20 2
WECS
RM K321
RTFRO 2 x 1.5 mm²
3 2 2 1.5 mm²
R23 1 1.5 mm²
R24 2 1
DAAF021685 -