Beruflich Dokumente
Kultur Dokumente
2
CR, CRI, CRN
1
1. Product introduction
Product introduction
This data booklet deals with Grundfos CR, CRI and Pump
CRN pumps.
The CR pump is a non-self-priming, vertical multistage
centrifugal pump. The pumps are available with a
Grundfos standard motor.
The pump consists of a base and a pump head. The
chamber stack and the outer sleeve are secured
between the pump head and the base by means of
staybolts. The base has suction and discharge ports
on the same level (in-line).
All pumps are equipped with a maintenance-free
mechanical shaft seal of the cartridge type.
GR5357 - GR3395
Grundfos CR pumps come with various pump sizes Base
and various numbers of stages to provide the flow and Base plate
the pressure required.
CR pumps are suitable for a variety of applications
from pumping of potable water to pumping of Fig. 2 CR pump
chemicals. The pumps are therefore used in a wide
variety of pumping systems where the performance CR pump with ANSI/NSF 61 listing is available. See
and material of the pump meet specific demands. UL file MH26400 or contact Grundfos.
The CR pumps consist of two main components: the
Motor
motor and the pump unit. The motor on a CR pump is a
heavy-duty Grundfos specified motor. Grundfos standard motors - ML and Baldor®
The pump unit consists of optimized hydraulics, motors
various types of connections, an outer sleeve, a top CR, CRI and CRN pumps are fitted with a Grundfos
and various other parts. specified motor. The motors are all heavy-duty 2-pole,
CR pumps are available in various material versions NEMA C-face motors.
according to the pumped liquid.
3
1 CR, CRI, CRN
RU C RUUS below, the motor must not be fully loaded due to the
risk of overheating.
Overheating may result from excessive ambient
* 1-10 Hp ML motors are premium efficiency as standard.
temperatures or the low density and consequently low
Optional motors cooling effect of the air at high altitudes. In such cases,
The Grundfos standard range of motors covers a wide it may be necessary to use a motor with a higher rated
variety of application demands. However, for special output (P2).
applications or operating conditions, custom-built
P2
motor solutions can be provided.
[%]
For special applications or operating conditions, 2
100
Grundfos offers custom-built motors such as:
90
• explosion proof motors 1
80
• motors with anti-condensation heating unit 70
• low-noise motors 60
Pos. Description
Terminal box positions 1 NEMA energy efficient motors
As standard the terminal box is mounted on the suction 2 NEMA premium-efficiency motors
side of the pump. Example: From fig. 4 it appears that P2 must be
reduced to 88 % when a pump with a NEMA premium-
efficiency ML motor is installed 15,584 ft (4750 m)
above sea level. At an ambient temperature of 167 °F
(75 °C), P2 of a standard-efficiency motor must be
reduced to 74 % of rated output.
TM02 18 05 2001
4
CR, CRI, CRN
2
2. Applications
Applications
Application CR, CRI CRN
Water supply
Filtration and transfer at waterworks
Distribution from waterworks
Pressure boosting in mains
Pressure boosting in high-rise buildings, hotels, etc.
Pressure boosting for industrial water supply
Industry
Recommended version.
Alternative version.
★ CRT, CRTE version available. For further information about CRT, CRTE pumps, see Pumped liquids on page 13 or related CRT, CRTE product
guide.
5
3 CR, CRI, CRN
3. Performance range
Performance range
H H
[m] [ft]
300 1000 60 Hz
CR 120
800 CRN 120
200 CR 150
600 CRN 150
400
100
300
80 CR 1 CR 5 CR 15 CR 32 CR 64
CRI 1 CRI 5 CRI 15 CRN 32 CRN 64
60 200 CRN 1 CRN 5 CRN 15
50 CR 1s CR 3 CR 10 CR 20 CR 45 CR 90
40 CRI 1s CRI 3 CRI 10 CRI 20 CRN 45 CRN 90
CRN 1s CRN 3 CRN 10 CRN 20
30 100
80
20
60
40
10
30
20
1 2 4 6 8 10 20 40 60 80 100 200 400 600 800
Q [US GPM]
1 2 3 4 5 6 7 8 10 20 30 40 50 60 80 100 Q [m³/h]
Eff
[%]
80
60
40
20
6
CR, CRI, CRN
4
4. Product range
Product range
Range CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20
Nominal flow rate [US gpm] 4.5 8.5 15 30 55 95 110
Temperature range [°F] -4 to +250
Temperature range [°F]
-40 to +356
- on request
Max. working pressure [psi] ★ 362 362 362 362 362 362 362
Max. working pressure [psi]
- 725 725 725 725 725 725
- on request
Max. pump efficiency [%] 35 49 59 67 70 72 72
CR pumps
CR: Flow range [US gpm] 0.5 - 5.7 1 - 12.8 1.5 - 23.8 3-45 5.5 - 70 9.5 - 125 11-155
CR: Max. pump pressure (H [ft]) 760 790 790 780 820 800 700
CR: Motor power [Hp] .33 - 2 .33 - 3 .33 - 5 .75 - 7.5 .75 - 15 2-25 3-25
Version
CR:
● ● ● ● ● ● ●
Cast iron and stainless steel AISI 304
CRI:
● ● ● ● ● ● ●
Stainless steel AISI 304
CRN:
● ● ● ● ● ● ●
Stainless steel AISI 316
CRT, CRTE:
- See CRT, CRTE product guide -
Titanium
CR pipe connection
Oval flange (NPT) 1" 1" 1" 1.25" 2" 2" 2"
Oval flange (NPT) - on request 1.25" 1.25" 1.25" 1" 1.5" - -
ANSI flange size 1.25" 1.25" 1.25" 1.25" 2" 2" 2"
ANSI flange size - on request - - - - - - -
ANSI flange class 250 lb. 250 lb. 250 lb. 250 lb. 250 lb. 250 lb. 250 lb.
CRI pipe connection
Oval flange (NPT) 1" 1" 1" 1.25" 2" 2" 2"
Oval flange (NPT) - on request 1.25" 1.25" 1.25" 1" 1.5" - -
ANSI flange size 1.25" 1.25" 1.25" 1.25" 2" 2" 2"
ANSI flange class 300 lb. 300 lb. 300 lb. 300 lb. 300 lb. 300 lb. 300 lb.
1", 1", 1", 1", 1.5", 1.5", 1.5"
Clamp coupling (NPT) - on request
1.25" 1.25" 1.25" 1.25" 2" 2" 2"
Union (NPT ext. Thread) - on request 2" 2" 2" 2" - - -
CRN pipe connection
PJE (Victaulic) 1.25" 1.25" 1.25" 1.25" 2" 2" 2"
PJE (Victaulic) - on request - - - - - - -
ANSI flange size 1.25" 1.25" 1.25" 1.25" 2" 2" 2"
ANSI flange size - on request - - - - - - -
ANSI flange class 300 lb. 300 lb. 300 lb. 300 lb. 300 lb. 300 lb. 300 lb.
1", 1", 1", 1", 1.5", 1.5", 1.5",
Clamp coupling (NPT) - on request
1.25" 1.25" 1.25" 1.25" 2" 2" 2"
Union (NPT ext. Thread) - on request 2" 2" 2" 2" - - -
CRT pipe connection
PJE coupling (Vitaulic) - 1.25" 1.25" 1.25" 2" 2" -
ANSI flange size - on request - - - - 2" 2" -
● Available.
★ See section 7. Operating conditions on page 13 for specific working pressures.
7
4 CR, CRI, CRN
Product range
● Available.
★ See section 7. Operating conditions on page 13 for specific working pressures.
1)
CRN 32 to CRN 90 with HQQE shaft seal: -40 °F to +250 °F.
2) CR, CRN 120 and 150 with 75 or 100 Hp motors with HBQE shaft seal: 0 °F to +250 °F.
3)
CR 5" flange is not manufactured to ANSI specification. Gasket contact surface is approximately 0.25". CR 6" ANSI flange adapter is manufactured
to ANSI B16.5 specification.
8
CR, CRI, CRN
5
5. Identification
Identification
Type key Example A -G -A -E -H QQ E
A Basic version
Example CR 32 (s) -4 -2 -A -G -G -E - HQQE
D Carbon-graphite filled PTFE (bearings)
Type range:
CR, CRI, CRN G Wetted parts AISI 316
3
Nominal flow rate [m /h] GI All parts stainless steel, wetted parts AISI 316
High-pressure pump with high speed MLE H Cemented tungsten carbide, embedded (hybrid)
HS
motor Q Silicon carbide
I Different pressure rating U Cemented tungsten carbide
J Pump with different max speed X Other ceramics
K Pump with low NPSH E EPDM
M Magnetic drive F FXM
N Fitted with sensor K FFKM
P Undersize motor V FKM
R Horizontal version with bearing bracket
1)
SF High pressure pump If a pump incorporates more than two pump versions, the code for
the pump version is X.
Over size motor X also indicates special pump versions not listed above.
T
(two flange sizes bigger)
X Special version
Pipe connection
9
6 CR, CRI, CRN
6. Construction
Construction
1
1
3 3
10
2 10
4 6
7 4
5 6
5
7
9 8
9
8
12
11
3 Shaft Stainless steel AISI 3161) 2 Pump head cover Stainless steel CF 8M 4)
AISI 4312)
AISI 3165)
4 Impeller Stainless steel AISI 304 3 Shaft Stainless steel AISI 3296)
5 Chamber Stainless steel AISI 304 AISI 4317)
6 Outer sleeve Stainless steel AISI 304
8 Base Stainless steel CF 8M 4)
O-ring for outer
7 EPDM or FKM 9 Neck ring PTFE
sleeve
8 Base Cast iron A 48-30 B 10 Shaft seal Cartridge type
9 Neck ring PTFE 11 Base plate Cast iron3) A 48-30 B
10 Shaft seal Cartridge type Bearing rings Silicon carbide
Bearing rings Silicon carbide Rubber parts EPDM or FKM
Rubber parts EPDM or FKM
CRI
12 FGJ flange Cast iron A 48-30 B 4 Impeller Stainless steel AISI 304
1) CR 1s, 1, 3, 5 5 Chamber Stainless steel AISI 304
2) 6 Outer sleeve Stainless steel AISI 304
CR 10, 15, 20
3) Stainless steel available on request. 7 O-ring for outer sleeve EPDM or FKM
4)
CF 8M is cast equivalent of AISI 316 stainless steel. 12 FGJ flange ring Ductile iron3) A 65-45-12
5)
CRI/CRN 1s, 1, 3, 5 Oval flange Stainless steel AISI 316
6)
CRN 10, 15, 20
7) CRN
CRI 10, 15, 20
4 Impeller Stainless steel AISI 316
5 Chamber Stainless steel AISI 316
6 Outer sleeve Stainless steel AISI 316
7 O-ring for outer sleeve EPDM or FKM
12 FGJ flange ring Ductile iron3) A 65-45-12
10
CR, CRI, CRN
6
CR 32, 45, 64 and 90 CRN 32, 45, 64 and 90
Construction
TM01 2150 1298
1)
Stainless steel available on request.
11
6 CR, CRI, CRN
GrA3732 - GrA3735
GrA3731
Sectional drawing Sectional drawing
12
CR, CRI, CRN
7
7. Operating conditions
Operating conditions
Pumped liquids List of pumped liquids
CR, CRI, CRN pumps are designed to pump thin, non- A number of typical liquids are listed on the following
explosive liquids, not containing solid particles or pages.
fibers. The liquid must not chemically attack the pump Other pump versions may be applicable, but those
materials. When pumping liquids with a density and/or stated in the list are considered to be the best choices.
viscosity higher than that of water, oversized motors The table is intended as a general guide only, and
must be used, if required. cannot replace actual testing of the pumped liquids
Whether a pump is suitable for a particular liquid and pump materials under specific working conditions.
depends on a number of factors of which the most The list should, however, be applied with some caution
important are the chloride content, pH value, as factors such as the following may affect the
temperature and content of chemicals, oils, etc. chemical resistance of a specific pump version:
Please note that aggressive liquids (e.g. sea water and • concentration of the pumped liquid
some acids) may attack or dissolve the protective • liquid temperature
oxide film of the stainless steel and thus cause • pressure.
corrosion. The CR, CRI, CRN pump types are suitable
Safety precautions must be made when pumping
for the following liquids:
dangerous liquids.
CR, CRI
Notes
• Non-corrosive liquids.
For liquid transfer, circulation and pressure boosting of D Often with additives.
cold or hot clean water. Density and/or viscosity differ from that of water.
E Allow for this when calculating motor output and pump
CRN performance.
• Industrial liquids. Pump selection depends on many factors.
F
Contact Grundfos.
In systems where all parts in contact with the liquid
H Risk of crystallization/precipitation in shaft seal
must be made of high-grade stainless steel.
1 The pumped liquid highly inflammable.
CRT
2 The pumped liquid is combustible.
• Saline liquids
• hypochlorites 3 Insoluble in water.
13
7 CR, CRI, CRN
Operating conditions
CR CRN
Liquid concentration,
Pumped liquid Note 1s, 1, 3, 5, 32, 45, 64, 90, 1s, 1, 3, 5, 32, 45, 64, 90,
liquid temperature
10, 15, 20 120, 150 10, 15, 20 120, 150
14
CR, CRI, CRN
7
Operating conditions
CR CRN
Liquid concentration,
Pumped liquid Note
liquid temperature 1s, 1, 3, 5, 32, 45, 64, 90, 1s, 1, 3, 5, 32, 45, 64, 90,
10, 15, 20 120, 150 10, 15, 20 120, 150
Sodium chloride (as coolant) NaCl D, E 30 %, < 41 °F, pH > 8 HQQE HQQE
Swimming pool water (low chloride) Max 5 ppm free chlorine (Cl2) HQQE HQQE/HBQE
15
7 CR, CRI, CRN
16
CR, CRI, CRN
7
Operating range of the shaft seal
Operating conditions
Shaft Max. temp. range
Description
seal [°F]
The operating range of the shaft seal depends on
O-ring (cartridge) (balanced seal),
operating pressure, pump type, type of shaft seal and HQQE
SiC/SiC, EPDM
-40 °F to +248 °F
liquid temperature. The following curves apply to clean O-ring (cartridge) (balanced seal),
HBQE +32 °F to +248 °F
water and water with anti-freeze liquids. For selecting Carbon/SiC, EPDM
the right shaft seal, see Pumped liquids on page 13. O-ring (cartridge) (balanced seal),
HBQV +32 °F to +194 °F
Carbon/SiC, FKM
CR 1s - CR 20 HQQV
O-ring (cartridge) (balanced seal),
-4 °F to +194 °F
SiC/SiC, FKM
p p O-ring (cartridge) (balanced seal),
HUBE +32 °F to +248 °F
[bar] [psi] TC/carbon, EPDM
400 O-ring (cartridge) (balanced seal),
25 HUBV
TC/carbon, FKM
+32 °F to +194 °F
20 300
HQQE
HQQE
HQQE
15 200
HQQV Note: TC= tungsten carbide
10 See section Lists of variants - on request on page 77,
100
5 in case of extreme temperatures:
0 0
-40 0 40 80 120 160 200 240 t [°F ]
p p
[bar] [psi]
400
25
20 300
HQQE
HQQV
HQQE
HQQE/V HQQE
15 200
10 HBQE/V HBQE
100
5
TM06 0051 4713
0 0
-80 -40 0 40 80 120 160 200 240 t [°F]
17
7 CR, CRI, CRN
18
CR, CRI, CRN
8
8. Selection and sizing
280
950
-10 CRN 32 950 then select a CR pump which is operating at a duty
900 -10-2 2-pole, 60 Hz 900
260 850 -9 850 point corresponding with the best efficiency of the
800 -9-2 800
240
220
750 -8 750 pump.
-8-2
700 700
350
-4
350 240
800 -9-2 800
Duty
-4-2
100
300 300
220
750 -8 750 point
-3 -8-2
80 700 700
250 -3-2 250
200 650 -7 650
60 200 -2 200
-7-2
-2-1 600 600
150 -2-2 150 180
40 -6
550 550
100 -1 100
160 -6-2
20 -1-1 500 500
50 50
140 -5
450 450
0 0 0 -5-2
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM] 120 400 400
-4
350 350
100 -4-2
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
P2 P2 Eff 300 300
[kW] [hp] [%] -3
80
4 Eff P2 1/1 80 250 -3-2 250
1 40
1 20
100 -1 100
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
20
50
-1-1
50 Best
H NPSH H
[m] [ft] [ft] 0 0 0 efficiency
30 30 0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
8
20 20
4 0 5 10 15 20 25 30 35 40 45 Q [m³/h]
10 NPSHR 10 P2 P2 Eff
[kW] [hp] [%]
0 0 0 4 Eff P2 1/1 80
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM] 3 P2 2/3 60
2
2 40
1
2. Sizing data 8
30
20
30
20
4
10 NPSHR 10
account.
Fig. 10 Example of a CR pump’s duty point
• Required flow and pressure at the point of use.
• Pressure loss as a result of height differences As the pump is sized on the basis of the highest
(Hgeo). possible flow, it is important to always have the duty
• Friction loss in the pipework (H f). point to the right of the optimum efficiency point (see
It may be necessary to account for pressure loss in fig. 11, range with check mark). This must be
connection with long pipes, bends or valves, etc. considered in order to keep efficiency high when the
• Best efficiency at the estimated duty point. flow drops.
• NPSH value. eff Optimum point
For calculation of the NPSH value, see Minimum
TM02 8579 0504
US GPM
Fig. 11 Best efficiency
19
8 CR, CRI, CRN
drive (VFD) are used in applications characterized by a The approximated formulas apply on condition that the
variable flow. Consequently, it is not possible to select system characteristic remains unchanged for nn and
a pump that is constantly operating at optimum nx and that it is based on the formula H = k x Q2,
efficiency. where k is a constant.
The power equation implies that the pump efficiency is
In order to achieve optimum operating economy, the
unchanged at the two speeds. In practice this is not
pump should be selected on the basis of the following quite correct.
criteria:
Finally, it is worth noting that the efficiencies of the
• The max. required duty point should be as close as frequency converter and the motor must be taken into
possible to the QH curve of the pump. account if a precise calculation of the power saving
• The required duty point should be positioned so that resulting from a reduction of the pump speed is
P2 is close to the max. point of the 100 % curve. wanted.
Between the min. and max. performance curves, H Q n
n n
pumps with a VFD have an infinite number of -------- = ------
Q n
x x
performance curves each representing a specific
Hn
speed. Therefore it may not be possible to select a
H
n n n 2
duty point close to the 100 % curve. nn ------- = ------
Hx Hx n x
nx
H
[ft]
Max. curve
Q
Eta
Eta Qx Qn
n
------- ª 1
x
Min. curve
TM02 7572 4803
0
0 Q [US GPM] Q
P Qx Qn
Fig. 12 Min. and max. performance curves
In situations where it is not possible to select a duty Pn n n 3
Pn ------- = ------
point close to the 100 % curve the affinity equations to Px n x
the right can be used. The head (H), the flow (Q) and
Legend
Hn Rated head in feet
Hx Current head in feet
Qn Rated flow in US gpm
Qx Current flow in US gpm
nn Rated motor speed in min-1 (n n = 3500 min-1)
nx Current motor speed in min-1
n Rated efficiency in %
x Current efficiency in %
20
CR, CRI, CRN
8
WinCAPS and WebCAPS 6. Inlet pressure and operating pressure
21
8 CR, CRI, CRN
H = Pb - NPSHR - Hf - Hv - Hs
Selection and sizing
tm Hv
(°F) (Ft)
370 413
360 328
340 259
Hf
320 203
300 148
131
280 115
H 98
Pb 270
NPSHR 82
250 66
230 49
Hv 39
212 33
26
194
20
176 16
13
158 10
140 6.6
4.9
122
3.3
104 2.6
2.0
TM02 7729 3903
86 1.3
0.9
68
0.7
50
0.3
32
22
CR, CRI, CRN
8
How to read the curve charts
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
Qmin
at a temperature of 68 °F (20 °C).
[%]
3. The curves apply to a kinematic viscosity of = 1 30
mm2/s (1 cSt).
20
4. Due to the risk of overheating, the pumps should
not be used at a flow below the minimum flow rate. 10
5. The QH curves apply to actual speed with the motor 0
TM02 7538 3703
23
9 Performance curves CR, CRI, CRN
Performance curves
9. Performance curves
CR, CRI, CRN 1s
H H H
[m] [ft] [ft]
750 -27
CR 1s 750
220 CRI 1s
700 -25 700
CRN 1s
200 650 650
-23 60 Hz, 2-pole
600 600
180 -21
550 550
160 -19
500 500
-17
140
450 450
-15
120 400 400
-13
350 350
100 -12
300 -11 300
-10
80
250 -9 250
-8
60 200 -7 200
-6
150 150
-5
40
-4
100 100
-3
20 -2
50 50
0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
0.00 0.00 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
H NPSH H
[m] [ft] [ft]
15 15
4
10 10
NPSHR
TM02 5741 1303
2
5 5
0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
24
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRI, CRN 1
H H H
[m] [ft] [ft]
800
CR 1 800
240 -27
750
CRI 1 750
-25
220 CRN 1
700 700
2-pole, 60 Hz
-23
200 650 650
-21
600 600
180
140
450 450
-15
60 200 -7 200
-6
150 -5 150
40
-4
100 100
-3
20 -2
50 50
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 12Q [US GPM]
0.00 0.00 0
0 1 2 3 4 5 6 7 8 9 10 11 12Q [US GPM]
H NPSH H
[m] [ft] [ft]
10 10
2
5 5
TM02 4083 4713
NPSHR
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 12Q [US GPM]
25
9 Performance curves CR, CRI, CRN
Performance curves
600 600
180 -19
550 550
160 -17
500 500
140 -15
450 450
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.15 P2 60
0.10
0.10 Eff 40
0.05
0.05 20
0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
H NPSH H
[m] [ft] [ft]
10 10
2 NPSHR
TM02 4084 4713
5 5
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
26
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRI, CRN 5
H H H
[m] [ft] [ft]
800
CR 5 800
240
750
-24
CRI 5 750
220 CRN 5
700 -22 700
2-pole, 60 Hz
200 650 -20 650
600 600
180
-18
550 550
160 -16
500 500
-15
140 -14
450 450
-13
120 400 400
-12
150 -5 150
40 -4
100 -3 100
20 -2
50 50
0 0 0
0 5 10 15 20 25 30 35 40 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.3 P2 60
Eff
0.2 0.2 40
0.1 0.1 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 Q [US GPM]
H NPSH H
[m] [ft] [ft]
15 15
4
10 10
TM02 4085 4713
2 NPSHR
5 5
0 0 0
0 5 10 15 20 25 30 35 40 Q [US GPM]
27
9 Performance curves CR, CRI, CRN
Performance curves
550 550
160
500 -10 500
140
450 -9 450
350 -7 350
100
300 -6 300
80 -5
250 250
200 -4 200
60
150 -3 150
40
100 -2 100
20 -1
50 50
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.8 80
P2
0.6 Eff 60
0.4
0.4 40
0.2
0.2 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
15 15
4
10 10
TM02 7221 4713
2
5 NPSHR 5
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
28
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRI, CRN 15
H H H
[m] [ft] [ft]
800
-12 CR 15 800
240
750
CRI 15 750
220 CRN 15
700 700
-10 2-pole, 60 Hz
200 650 650
600 -9 600
180
550 550
-8
160
500 500
-7
140
450 450
400 -6 400
120
350 -5 350
100
300 300
-4
80
250 250
-3
60 200 200
150 -2 150
40
100 100
-1
20
50 50
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
2.0 Eff 80
1.5 P2 60
1.0
1.0 40
0.5
0.5 20
0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
H NPSH H
[m] [ft] [ft]
6 20 20
15 15
4
10 10
TM02 7222 4713
2
5 NPSHR 5
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
29
9 Performance curves CR, CRI, CRN
Performance curves
600 600
180
-8
550 550
160
500 -7 500
140
450 450
-6
120 400 400
350 -5 350
100
300 300
-4
80
250 250
-3
60 200 200
150 -2 150
40
100 100
-1
20
50 50
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 80
3 Eff 60
2
P2
2 40
1
1 20
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
H NPSH H
[m] [ft] [ft]
30 30
8
20 20
TM02 7223 4713
4
10 10
NPSHR
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
30
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRN 32
H H H
[m] [ft] [ft]
300
1000 -11-2 CR 32 1000
950
-10 CRN 32 950
280
900 -10-2 2-pole, 60 Hz 900
550 -6 550
160 -6-2
500 500
140 -5
450 450
-5-2
120 400 400
-4
350 350
100 -4-2
300 300
-3
80
250 -3-2 250
60 200 -2 200
-2-1
150 -2-2 150
40
100 -1 100
20 -1-1
50 50
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff P2 1/1 80
3 P2 2/3 60
2
2 40
1
1 20
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
H NPSH H
[m] [ft] [ft]
30 30
8
20 20
TM02 0039 4713
4
10 NPSHR 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
31
9 Performance curves CR, CRI, CRN
Performance curves
CR, CRN 45
H H H
[m] [ft] [ft]
950
-8-1
CR 45 950
280
900 CRN 45 900
-7
260 850 2-pole, 60 Hz 850
150 150
40 -1
100 -1-1 100
20
50 50
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
8 P2 1/1 80
Eff
6 P2 2/3 60
4
4 40
2
2 20
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
H NPSH H
[m] [ft] [ft]
30 30
8
20 20
TM02 0040 4713
4
10 NPSHR 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
32
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRN 64
H H H
[m] [ft] [ft]
CR 64
600 -5-2 600
180 CRN 64
550 -4 2-pole, 60 Hz 550
160
-4-1
500 500
140 -4-2
450 450
-3
120 400 400
-3-1
350 350
100 -3-2
300 300
-2
80
250 250
-2-1
60 200 200
-2-2
150 -1 150
40
20
50 50
0 0 0
0 40 80 120 160 200 240 280 320 360 400 Q [US GPM]
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
16 80
Eff
12 P2 1/1 60
8
8 P2 2/3 40
4
4 20
0 0 0
0 40 80 120 160 200 240 280 320 360 400 Q [US GPM]
H NPSH H
[m] [ft] [ft]
30 30
8
20 20
TM02 0041 4713
4
10 NPSHR 10
0 0 0
0 40 80 120 160 200 240 280 320 360 400 Q [US GPM]
33
9 Performance curves CR, CRI, CRN
Performance curves
CR, CRN 90
H H H
[m] [ft] [ft]
CR 90
600 600
180 CRN 90
-4-1
550
2-pole, 60 Hz 550
160 -4-2
500 500
140 -3
450 450
-3-1
120 400 400
-3-2
350 350
100
-2
300 300
80 -2-1
250 250
-2-2
60 200 200
150 -1 150
40
-1-1
100 100
20
50 50
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [US GPM]
4
10 NPSHR 10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [US GPM]
34
CR, CRI, CRN Performance curves
9
Performance curves
CR, CRN 120
H H
[m] [ft]
700
CR 120
5-1
200 650
CRN 120
5-2
2-pole, 60 Hz
600
180
4
550
4-1
160
500 4-2
140
450
-3
400 3-1
120
3-2
350
100
300 2
80 2-1
250
2-2
60 200
150 1
40
1-1
100
20
50
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [US GPM]
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [US GPM]
H H NPSH
[m] [ft] [ft]
160 40
QH 3500 rpm1n
40
120 30
30 QH 3500 rpm2/3
80 20
20
TM03 9192 0209
40 NPSH 10
10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [US GPM]
35
9 Performance curves CR, CRI, CRN
Performance curves
120 400
3-2
350
100 2
300
2-1
80
250
2-2
60 200
1
150
40
1-1
100
20
50
0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [US GPM]
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [US GPM]
H H NPSH
[m] [ft] [ft]
160 QH 3500 rpm1n 40
40
120 QH 3500 rpm2/3 30
30
80 20
20
TM03 9193 4213
NPSH
10 40 10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [US GPM]
36
CR, CRI, CRN Technical data
10
Technical data
10. Technical data
CR 1s
D2 D2
D1 D1
B2
B2
1 1/4"250 lb.R.F.
SUCTION AND
DISCHARGE
ø3 15/16"
B1
ø3 1/2"
B1
13/16"
4 x ø1/2"
13/16"
4 x ø1/2"
3 15/16" 3" 3 15/16" ø1 3/8"
5 11/16" 7 1/16" 5 9/16" 7 1/16"
6 5/16" 8 11/16" 9 7/8" 8 11/16"
37
10 Technical data CR, CRI, CRN
Technical data
CRI 1s
D2 D2
D1 D1
B2
B2
B1
3/4 x 1 1/16"
B1
ø4 1/8"
1"NPT (F)
ø3 1/2"
ø1 11/16"
DRAIN ø1/2"
DRAIN SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE
M10 x 40
ø5 1/2"
4 x 1/2"
13/16"
1 3/8"
3" 4 x ø1/2"
3 15/16" 7 1/16" 3 15/16" ø1 1/4"
5 15/16" ø3 3/8"
5 15/16" 8 5/16"
9 7/8" 7 1/16
8 5/16" 8 1/4"
38
CR, CRI, CRN Technical data
10
Technical data
CRN 1s
D2
D2
D1
D1
B2
B2
B1
3/4 x 1 1/16"
ø4 1/8"
ø3 1/2"
B1
DRAIN ø1/2"
1 1/4" Victaulic-type PLUG (G 1/2)
DRAIN SUCTION AND
PLUG (G 1/2) DISCHARGE
ø5 1/2"
TM03 1454 2205
3"
2"
1 3/8"
4 x ø1/2"
13/16"
39
10 Technical data CR, CRI, CRN
Technical data
CR 1
D2 D2
D1 D1
B2
B2
1 1/4"250 lb.R.F.
SUCTION AND
DISCHARGE
ø3 15/16"
B1
B1
ø3 1/2"
1"NPT (F) DRAIN
DRAIN SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE 3/4"x1"
7/8" M10 x 40
ø5 1/2"
TM03 1450 2205
4 x ø1/2"
13/16"
13/16"
4 x ø1/2"
3 15/16" 3" 3 15/16" ø1 3/8"
5 11/16" 7 1/16" 5 9/16" 7 1/16"
6 5/16" 8 11/16" 9 7/8" 8 11/16"
40
CR, CRI, CRN Technical data
10
Technical data
CRI 1
D2 D2
D1 D1
B2
B2
1 1/4"250 lb.R.F.
SUCTION AND
DISCHARGE
ø3 15/16"
B1
B1
ø3 1/2"
1"NPT (F) DRAIN
DRAIN SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE 3/4"x1"
7/8" M10 x 40
ø5 1/2"
TM03 1450 2205
4 x ø1/2"
13/16"
13/16"
4 x ø1/2"
3 15/16" 3" 3 15/16" ø1 3/8"
5 11/16" 7 1/16" 5 9/16" 7 1/16"
6 5/16" 8 11/16" 9 7/8" 8 11/16"
41
10 Technical data CR, CRI, CRN
Technical data
CRN 1
D2 D2
D1 D1
B2
B2
B1
3/4 x 1 1/16"
B1
1 1/4" Victaulic-type
ø4 1/8"
ø3 1/2"
DRAIN SUCTION AND DRAIN ø1/2"
PLUG (G 1/2) DISCHARGE PLUG (G 1/2)
ø5 1/2"
4 x 1/2"
13/16"
1 3/8"
4 x ø1/2"
3 15/16" 7 1/16"
3 15/16" ø1 1/4"
5 15/16" 8 5/16" 5 15/16" ø3 3/8"
8 1/4" 9 7/8" 7 1/16
8 1/4"
42
CR, CRI, CRN Technical data
10
Technical data
CR 3
D2 D2
D1 D1
B2
B2
1 1/4"250 lb.R.F.
SUCTION AND
DISCHARGE
ø3 15/16"
B1
B1
ø3 1/2"
1"NPT (F) DRAIN
DRAIN SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE 3/4"x1"
7/8" M10 x 40
ø5 1/2"
TM03 1450 2205
4 x ø1/2"
13/16"
13/16"
4 x ø1/2"
3 15/16" 3" 3 15/16" ø1 3/8"
5 11/16" 7 1/16" 5 9/16" 7 1/16"
6 5/16" 8 11/16" 9 7/8" 8 11/16"
43
10 Technical data CR, CRI, CRN
Technical data
CRI 3
D2 D2
D1 D1
B2
B2
B1
3/4 x 1 1/16"
B1
ø4 1/8"
1"NPT (F)
ø3 1/2"
ø1 11/16"
DRAIN ø1/2"
DRAIN SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE
M10 x 40
ø5 1/2"
4 x 1/2"
13/16"
1 3/8"
3" 4 x ø1/2"
3 15/16" 7 1/16" 3 15/16" ø1 1/4"
5 15/16" ø3 3/8"
5 15/16" 8 5/16"
9 7/8" 7 1/16
8 5/16" 8 1/4"
44
CR, CRI, CRN Technical data
10
Technical data
CRN 3
D2 D2
D1 D1
B2
B2
B1
B1
ø4 1/8"
ø3 1/2"
DRAIN SUCTION AND DRAIN ø1/2"
PLUG (G 1/2) DISCHARGE PLUG (G 1/2)
ø5 1/2"
4 x 1/2"
3"
13/16"
1 3/8"
4 x ø1/2"
3 15/16" 7 1/16"
3 15/16" ø1 1/4"
5 15/16" 8 5/16"
5 15/16" ø3 3/8"
8 1/4" 9 7/8" 7 1/16
8 1/4"
45
10 Technical data CR, CRI, CRN
Technical data
CR 5
D2 D2
D1 D1
B2
B2
1 1/4"250 lb.R.F.
SUCTION AND
DISCHARGE
ø3 15/16"
B1
B1
ø3 1/2"
1 1/4"NPT (F) DRAIN
DRAIN SUCTION AND PLUG (G 1/2) 3/4"x1"
PLUG (G 1/2) DISCHARGE
7/8" M10 x 40
ø5 1/2"
TM03 1455 2205
4 x ø1/2"
13/16"
13/16"
4 x ø1/2"
3 15/16" 3" 3 15/16" ø1 3/8"
5 11/16" 7 1/16" 5 9/16" 7 1/16"
6 5/16" 8 11/16" 9 7/8" 8 11/16"
46
CR, CRI, CRN Technical data
10
Technical data
CRI 5
D2 D2
D1 D1
B2
B2
PRIMING G 1/2 PLUG PRIMING
G 1/2 PLUG PORT (G 1/2)
WITH 1/4"TAP PORT (G 1/2) WITH 1/4"TAP
FOR GAUGE/ FOR GAUGE/
SENSOR SENSOR
1 1/4"300 lb.R.F.
SUCTION AND
DISCHARGE
B1
3/4 x 1 1/16"
B1
ø4 1/8"
1 1/4"NPT (F)
ø3 1/2"
DRAIN
ø1 11/16"
ø5 1/2"
4 x 1/2"
1 3/8"
4 x ø1/2"
13/16"
3"
3 15/16" ø1 1/4"
3 15/16" 7 1/16" 5 15/16" ø3 3/8"
5 15/16" 8 5/16" 9 7/8" 7 1/16
8 5/16" 8 1/4"
47
10 Technical data CR, CRI, CRN
Technical data
CRN 5
D2
D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING G 1/2 PLUG PRIMING
WITH 1/4"TAP PORT (G 1/2) WITH 1/4"TAP PORT (G 1/2)
FOR GAUGE/ FOR GAUGE/
SENSOR SENSOR
1 1/4"300 lb.R.F.
SUCTION AND
DISCHARGE
B1
3/4 x 1 1/16"
B1
ø4 1/8"
1 1/4" Victaulic-type
ø3 1/2"
DRAIN DRAIN ø1/2"
SUCTION AND PLUG (G 1/2)
PLUG (G 1/2) DISCHARGE
ø5 1/2"
4 x 1/2"
3"
TM03 1454 2205
13/16"
1 3/8"
4 x ø1/2"
3 15/16" 7 1/16" 3 15/16" ø1 1/4"
5 15/16" 8 5/16" 5 15/16" ø3 3/8"
9 7/8" 7 1/16
8 1/4"
8 1/4"
48
CR, CRI, CRN Technical data
10
Technical data
CR 10
D2 D2
D1 D1
B2
B2
B1
ø2 9/16"
B1
SUCTION AND
DISCHARGE DRAIN
DRAIN PLUG (G 1/2) 3/4 x 7/8"
PLUG (G 1/2) 1 3/16" M10 x 40
ø6 1/2"
ø5"
4 x ø9/16"
3 1/2"
3 1/2"
49
10 Technical data CR, CRI, CRN
Technical data
CRI 10
D2 D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING
PRIMING WITH 1/4"TAP PORT (G 1/2)
G 1/2 PLUG
WITH 1/4"TAP PORT (G 1/2) FOR GAUGE/
FOR GAUGE/ SENSOR
SENSOR
2" ANSI 300 lb.
R.F.
B1
2" NPT DRAIN 3/4 x 7/8"
B1
ø6 1/2"
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
5 1/8" 3 15/16"
7 7/8" ø4 3/4"
7 7/8" 8 1/2"
11 7/8" 8 1/2"
10 1/8" 9 3/4"
9 3/4"
50
CR, CRI, CRN Technical data
10
Technical data
CRN 10
D2 D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING
G 1/2 PLUG PRIMING WITH 1/4"TAP PORT (G 1/2)
WITH 1/4"TAP PORT (G 1/2) FOR GAUGE/
FOR GAUGE/ SENSOR 2" ANSI 300 lb.
SENSOR
R.F.
B1
2" Victaulic-type
DRAIN
B1
SUCTION AND
PLUG (G 1/2) 3/4 x 7/8"
DRAIN DISCHARGE
PLUG (G 1/2)
ø6 1/2"
1 1/16"
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
51
10 Technical data CR, CRI, CRN
Technical data
CR 15
D2
D2
D1
D1
B2
B2
B1
ø2 9/16"
B1
ø6 1/2"
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
5 1/8" 5 1/8"
5 1/8" 8 1/2"
8 1/2" 6 15/16"
7" 10 1/8"
10 1/8" 11 7/8"
7 7/8"
52
CR, CRI, CRN Technical data
10
Technical data
CRI 15
D2
D1
D2
D1
B2
B2
B1
DRAIN 3/4 x 7/8"
2" NPT PLUG (G 1/2)
B1
SUCTION AND
DRAIN DISCHARGE
ø6 1/2"
PLUG (G 1/2)
M12x80
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
53
10 Technical data CR, CRI, CRN
Technical data
CRN 15
D2 D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING
G 1/2 PLUG PRIMING WITH 1/4"TAP PORT (G 1/2)
WITH 1/4"TAP PORT (G 1/2) FOR GAUGE/
FOR GAUGE/ SENSOR 2" ANSI 300 lb.
SENSOR
R.F.
B1
2" Victaulic-type
DRAIN
B1
ø6 1/2"
1 1/16"
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
54
CR, CRI, CRN Technical data
10
Technical data
CR 20
D2 D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING PRIMING
PORT (G 1/2) G 1/2 PLUG
WITH 1/4"TAP WITH 1/4"TAP PORT (G 1/2)
FOR GAUGE/ FOR GAUGE/
SENSOR SENSOR 2" ANSI 250 lb.
R.F.
2" NPT
B1
SUCTION AND
B1
ø2 9/16"
DRAIN DISCHARGE DRAIN
PLUG (G 1/2) 1 3/16" PLUG (G 1/2) 3/4 x 7/8"
M10 x 40
ø6 1/2"
ø5"
4 x ø9/16"
3 1/2"
3 1/2"
TM03 1460 2205
13/16"
5 1/8" 5 1/8" 5 1/8" ø4 3/4" 4 x ø9/16"
7" 8 1/2" 6 15/16" 8 1/2"
7 7/8" 10 1/8" 11 7/8" 10 1/8"
55
10 Technical data CR, CRI, CRN
Technical data
CRI 20
D2
D2
D1
D1
B2
B2
B1
2" NPT
DRAIN
B1
SUCTION AND
PLUG (G 1/2) 3/4 x 7/8"
DRAIN DISCHARGE
PLUG (G 1/2)
M12x80
ø6 1/2"
ø5"
3 1/2"
4 x ø9/16"
3 1/2"
56
CR, CRI, CRN Technical data
10
Technical data
CRN 20
D2 D2
D1 D1
B2
B2
G 1/2 PLUG PRIMING
G 1/2 PLUG PRIMING PORT (G 1/2)
PORT (G 1/2) WITH 1/4"TAP
WITH 1/4"TAP FOR GAUGE/
FOR GAUGE/ SENSOR
SENSOR
2" ANSI 300 lb.
2" Victaulic-type R.F.
B1
B1
ø6 1/2"
ø5"
4 x ø9/16"
3 1/2"
3 1/2"
57
10 Technical data CR, CRI, CRN
Technical data
CR 32
1) Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
58
CR, CRI, CRN Technical data
10
Technical data
CRN 32
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
59
10 Technical data CR, CRI, CRN
Technical data
CR 45
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
60
CR, CRI, CRN Technical data
10
Technical data
CRN 45
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
61
10 Technical data CR, CRI, CRN
Technical data
CR 64
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
62
CR, CRI, CRN Technical data
10
Technical data
CRN 64
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
63
10 Technical data CR, CRI, CRN
Technical data
CR 90
4-5 STAGES
D1
4" ANSI
D2 250 LB R.F.
G 12
8X Ø 78
9
4X Ø 16
B2 5 78 7 78 10
3 15
1 34 16
11
13 11
16
1-3 STAGES
4" ANSI
G 1 2 PLUG PRIMING 125 LB R.F.
G 12
B1
WITH 1/4" PORT G 1 2
TAP FOR
SENSOR/ 8X Ø 34
GAUGE
9
4X Ø 16
6 18 7 12 9
1
5 2
1) Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
64
CR, CRI, CRN Technical data
10
Technical data
CRN 90
D1 4 STAGES
D2 4" ANSI
300 LB R.F.
G 12
8X Ø 78
B2 9
4X Ø 16
6 81 7 78 10
3 15
1 34 16
11
11
13 16
1-3 STAGES
4 " ANSI
G 1 2 PLUG PRIMING 150 LB R.F.
WITH 1/4" G 12
B1 PORT G 1 2
TAP FOR
SENSOR/ 8X Ø 34
GAUGE
9
4X Ø 16
6 81 7 21 9
1
5 2
10 5 11
16
11
15 13 16
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
65
10 Technical data CR, CRI, CRN
Technical data
CR 120
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
2) This is a 5" loose flange ring. When using a 5" mating flange, the gasket contact surface is reduced to approximately 0.25". A 4" loose flange ring is
available for 4" pipe work. This will provide a standard gasket contact surface. Also available is a 6" ANSI flange adapter manufactured to ANSI
B16.5 specifications.
3)
CR 120-5-1, 125 Hp, ODP motor only.
All dimensions in inches unless otherwise noted.
66
CR, CRI, CRN Technical data
10
Technical data
CRN 120
1-1 to 4-2 STAGES
5" FLANGE2)
1) Weights are based on pump with TEFC motor (see price list for individual weights).
2)
This is a 5" loose flange ring. When using a 5" mating flange, the gasket contact surface is reduced to approximately 0.25". A 4" loose flange ring is
available for 4" pipe work. This will provide a standard gasket contact surface. Also available is a 6" ANSI flange adapter manufactured to ANSI
B16.5 specifications.
3)
CRN 120-5-1, 125 Hp, ODP motor only.
All dimensions in inches unless otherwise noted.
67
10 Technical data CR, CRI, CRN
Technical data
CR 150
1 to 3 STAGES
5" FLANGE2)
4 to 5 STAGES
5" FLANGE2)
1) Weights are based on pump with TEFC motor (see price list for individual weights).
2)
This is a 5" loose flange ring. When using a 5" mating flange, the gasket contact surface is reduced to approximately 0.25". A 4" loose flange ring is
available for 4" pipe work. This will provide a standard gasket contact surface. Also available is a 6" ANSI flange adapter manufactured to ANSI
B16.5 specifications.
All dimensions in inches unless otherwise noted.
68
CR, CRI, CRN Technical data
10
Technical data
CRN 150
1 to 3 STAGES
5" FLANGE2)
4 to 5 STAGES
5" FLANGE2)
1)
Weights are based on pump with TEFC motor (see price list for individual weights).
2) This is a 5" loose flange ring. When using a 5" mating flange, the gasket contact surface is reduced to approximately 0.25". A 4" loose flange ring is
available for 4" pipe work. This will provide a standard gasket contact surface. Also available is a 6" ANSI flange adapter manufactured to ANSI
B16.5 specifications.
All dimensions in inches unless otherwise noted.
69
11 CR, CRI, CRN
ODP motors
(Open Drip Proof, constant speed)
ODP ODP ODP ODP full
ODP ODP voltage ODP service ODP starting
Hp Ph ODP frame motor insul. KVA load
S.F. [V] factor current current
eff. % class code current
70
CR, CRI, CRN
11
TEFC motors
Motor data
(Totally Enclosed Fan Cooled, constant speed)
Baldor motor Grundfos ML motors
Gr7848sh
GR 7845
Service factor
Voltage Motor eff. Insul. KVA Full load current Starting current Motor
Hp Ph Frame S.F. current
[V] [%] class code [A] [A] type
[A]
1 56C 1.35 115/230 55 B K 6.0/3.0 7.6/3.8 28/14 Baldor
1/3
3 56C 1.35 208-230/460 78.5 F L 1.12-1.1/0.55 1.5-1.45/0.75 7.1-7.7/3.9 ML
1 56C 1.6 115/230 62 B K 7.4/3.7 9.8/4.9 39/19.5 Baldor
1/2
3 56C 1.25 208-230/460 78.5 F K 1.64-1.55/0.78 2.0-1.9/0.95 9.7-10.1/5.1 ML
1 56C 1.25 115/230 66 B K 9.6/4.8 11.4/5.7 56/28 Baldor
3/4
3 56C 1.25 208-230/460 79 F K 2.4-2.3/1.2 2.9-2.75/1.4 14.2-15/7.8 ML
1 56C 1.25 115/230 66 B K 12/6.0 14.4/7.2 77/38.5 Baldor
1
3 56C 1.25 208-230/460 80 F J 3.25-3.35/1.68 4.0-3.9/1.95 19.2-21.8/10.9 ML
1 56C 1.3 115/208-230 71 B K 17/9.5-8.6 20.4/11.3-10.2 106/58.6-53 Baldor
1 1/2
3 56C 1.15 208-230/460 84 F M 4.7-4.6/2.3 5.2-5.1/2.55 33.8-36.8/18.4 ML
1 56C 1.15 115/208-230 74 F K 23/12.7-11.5 25.4/14.0-12.7 156/86-78 Baldor
2
3 56C 1.15 208-230/460 85.5 F G 5.7-5.4/2.7 6.55-6.1/3.05 46.2-48.6/24.3 ML
1 182TC 1.15 115/208-230 75 F H 29/16-14.5 31.8/18-15.9 170/94-85 Baldor
3
3 182TC 1.15 208-230/460 86.5 F M 8.35-7.50/3.75 9.10-8.15/4.10 86.8-78.0/39.0 ML
1 213TCZ 1.15 208-230 80 F J 24-22 27-25 188-170 Baldor
5
3 182TC 1.15 208-230/460 88.5 F L 14.1-13.1/7.29 16.2-15.0/8.4 207-193/107 ML
1 213TC 1.15 208-230 82 F F 33.8-31 38.5-35.5 244-220 Baldor
7 1/2
3 213TC 1.15 208-230/460 89.5 F N 19.5-18.1/9.09 22.4-20.8/10.4 289-267/135 ML
1 213TC 1.15 230 85.5 F F 40 46 284 Baldor
10
3 215TC 1.15 208-230/460 90.2 F K 26.5-24.6/12.4 29.0-27.0/13.6 261-243/123 ML
15 3 254TC 1.15 208-230/460 91 F J 37.5-34/17 41.0-37.5/18.6 369-338/168 ML
20 3 254TC 1.15 208-230/460 91 F K 50.5-46/23 55.5-50.5/25.5 450-410/207 ML
25 3 284TSC 1.15 230/460 91.7 F J 62.0-56/28 68.0-61.5/31.0 510-462/233 ML
30 3 286TSC 1.15 230/460 91.7 F H 74.0-67.0/33.5 81.5-73.5/37.0 595-537/271 ML
40 3 286TSC 1.15 230/460 91.7 F G 88/44 102/51 614/307 Baldor
50 3 326TSC 1.15 230/460 93 F G 110/55 128/64 746/393 Baldor
60 3 364TSC 1.15 230/460 93 F G 134/67 154/77 918/459 Baldor
75 3 365TSC 1.15 230/460 93 F G 166/83 188/94 1162/581 Baldor
100 3 405TSC 1.15 230/460 93.6 F G 216/108 246/123 1422/711 Baldor
71
12 CR, CRI, CRN
12. Accessories
Accessories
Pipework connections
For pipework connection, various sets of counter
flanges and couplings are available.
Adapter kit
6" flanges are available for CR, CRN 120 and 150
pumps. To use 6" flanges, two adapter kits must be
ordered per pump.
Number of
Pipe Product
Adapter kit Pump type flange kits
connection number
needed
6" RF
CR 120
250 lb. 2 96638184
CR 150
Ductile iron
TM04 0021 4807
6" RF
CRN 120
300 lb. 2 96638186
6 3/16” CRN 150
ANSI 316 SS
9 1/4”
CR 1s
TM02 5691 3802
CR 1
Threaded ANSI 250 lb. 1 1/4" NPT 91122260
CR 3
3-1/16" CR 5
3-7/8"
5-1/2"
3/4"
TM02 5692 3802
CR 10
CR 15 Threaded ANSI 250 lb. 2" NPT 335021
CR 20
4-3/16"
5"
6-1/2"
3/4" 7/8"
Threaded ANSI 125 lb. 2 1/2" NPT 559601
CR 32
3/4" 7/8"
TM02 5695 + 5696 3802
CR 45
5-11/16"
6" 6-5/8" Threaded ANSI 250 lb. 3" NPT 91121952
7-1/2" 8-1/4"
72
CR, CRI, CRN
12
Accessories
Pipework Product
Counter flange Pump type Description Pressure class
connection number
CR 64
CR 90
6-15/16"
Threaded ANSI 250 lb. 4" NPT 3600028
7-1/2" 7-7/8"
9" 10"
CR 120
CR 150
10.0” 11.0”
3/4"
TM02 5691 3802
CRI, CRN
Threaded ANSI 300 lb. 1 1/4" NPT 91129013
1s, 1, 3 and 5
3-1/16"
3-7/8"
5-1/2"
3/4"
TM02 5692 3802
CRI,
CRN Threaded ANSI 300 lb. 2" NPT 339919
4-3/16"
10, 15, 20
5"
6-1/2"
3/4" 7/8"
Threaded ANSI 150 lb. 2 1/2" NPT 91121951
CRN 32
3/4" 7/8"
TM02 5695 + 5696 3802
CRN 45
5-11/16"
6" 6-5/8" Threaded ANSI 300 lb. 3" NPT 91121954
7-1/2" 8-1/4"
73
12 CR, CRI, CRN
Accessories
Pipework Product
Counter flange Pump type Description Pressure class
connection number
CRN 64
CRN 90
6-15/16"
Threaded ANSI 300 lb. 4" NPT 91121955
7-1/2" 7-7/8"
9" 10"
CRN 120
CRN 150
10.0” 11.0”
EPDM 1 4013010
CRI, CRN
Threaded 1160 psi 1 1/4" NPT
1s, 1, 3 and 5
FKM 1 0ID00118
TM00 3808 1094
CRI, CRN
1s, 1, 3 and 5
1" NPT Klingersil 96480850
Oval
(stainless steel)
1 1/4" NPT Klingersil 96480851
EPDM 96480852
TM02 1145 0601
FKM 96480853
74
CR, CRI, CRN
12
Accessories
Pipework Product
Base connections Pump type Connection Rubber parts
connection number
EPDM 96480858
FKM 96480859
EPDM 96480854
1" NPT
FKM 96480855
CRI, CRN Clamp, threaded
CRI, CRN
10, 15 and 20
Oval (stainless
2" NPT Klingersil 96498839
steel)
EPDM 96511402
TM02 7238 2803
FKM 96511403
EPDM 96500271
1 1/2" NPT
FKM 96500272
EPDM 96500273
CRI, CRN Clamp, threaded
2" NPT
10, 15 and 20 pipe stub
FKM 96500274
TM02 7239 2803
EPDM 96508602
2" NPT
FKM 96508603
75
12 CR, CRI, CRN
class?
Commonly asked questions Pressure ratings are affected by:
• Material
What is the "pressure class"?
• sealing methods
• The pressure class is a pressure rating expressed
as a dimensionless number. • operating temperatures.
• Pressure class does not affect the pump working Are pump flanges compatible with mating flanges
pressure. of a different pressure class?
• The class rating charts in ANSI B16.5 give actual • The multiflange used on a CR 1s through 20 can be
pounds per square inch maximum allowable used on both 125 lb and 250 lb installations.
pressure at a given temperature. • The multiflange on a CRI/CRN 1s through 20 can be
• 150 lb, 150# or Class 150 are different ways to write used on both 150 lb and 300 lb installations.
the same pressure class. • All other mating flange classes must match the
pump flange class.
Pressure
Pump Flange Size Material Mate with:
class
76
CR, CRI, CRN
13
13. Variants
Variants
Lists of variants - on request Shaft seals
Although the Grundfos CR, CRI, CRN product range
Variant Description
offers a number of pumps for different applications,
customers require specific pump solutions to satisfy Shaft seal with Shaft seals with FFKM or FXM o-ring material are
FFKM O-ring recommended for applications where the pumped
their needs. material liquid may damage the standard O-ring material.
Below please find the range of options available for Seal with flush, Recommended for applications involving
customizing the CR pumps to meet the customers' quench seal crystallizing, hardening or sticky liquids.
demands. Contact Grundfos for further information or Recommended for applications involving extremely
for requests other than the ones mentioned below. high temperatures.
No conventional mechanical shaft seal can
withstand liquid temperatures of up to 356 °F for
Cool-Top ® any length of time.
Motors shaft seal For that type of application, Grundfos' unique air-
system cooled shaft seal system is recommended.
Variant Description In order to ensure a low liquid temperature around
the standard shaft seal, the pump is fitted with a
For operation in hazardous atmospheres, special air-cooled shaft seal chamber.
Explosion proof
explosion-proof or dust-ignition-proof No separate cooling is required.
motors
motors may be required. Recommended for applications involving poisonous
Motors with anti- For operation in humid environments or explosive liquids.
condensation heating motors with built-in anti-condensation Protects the surrounding environment and the
unit heating may be required. Double shaft people working in the vicinity of the pump.
seal with Consists of two seals mounted in a "back-to-back"
Premium efficient Grundfos offers motors from 1 to 100 Hp pressure arrangement inside a separate pressure seal
motors with a Premium efficiency class. chamber chamber. As the pressure in the chamber is higher
If technically possible, Grundfos can fit the than the pump pressure, leakage is prevented. A
pump with a motor of a brand other than the dosing pump or a special pressure-intensifier
standard. This will normally increase the generates the seal chamber pressure.
Different motor brand Magnetically driven pumps for industrial
time of delivery. Alternatively, the pump can
be supplied without a motor (motor thrust applications.
rating must be checked). Key applications are industrial processes involving
CRN MAGdrive
Ambient temperatures above 104 °F or the handling of aggressive, environmental,
installation at altitudes of more than 3280 ft dangerous or volatile liquids, e.g. organic
Oversized motor compounds, solvents, etc.
above sea level require the use of an
oversized motor (i.e. derating).
Grundfos offers standard motors fitted with
4-pole motors
4-poles. Pumps
Variant Description
Connections and other variants For safety or height reasons, certain
applications, for instance on ships, require the
Horizontally
Variant Description pump to be mounted in the horizontal position.
mounted pump
For easy installation the pump is equipped
In addition to the wide range of standard with brackets that support motor and pump.
flange connections, a 232 psi DIN standard
Pipe connections clamping flange is available. Exposed to temperatures down to -40 °F,
Customized flanges are available Low-temperature coolant pumps may require neck-rings with a
according to specifications. pump to -40 °F different diameter in order to prevent impeller
drag.
TriClamp connections are of a hygienic
TriClamp connections design with a sanitary coupling for use in For high-pressure applications, a unique pump
the pharmaceutical and food industry. capable of generating up to 681 psi pressure
is available.
To substantially reduce the risk of corrosion The pump is equipped with a high-speed
Electropolished of the materials. High-speed pump
motor, type MLE. The direction of rotation is
pumps For use in the pharmaceutical/food up to 681 psi
the opposite of that of standard pumps, and
industry. the chamber stack is turned upside-down, as a
result of which the pumped liquid flows in the
opposite direction.
For high-pressure applications, a unique
High-pressure
double pump system capable of generating up
pump up to 696 psi
to 696 psi pressure is available.
Recommended for boiler-feed applications
Low-NPSH pump
where cavitation may occur due to poor inlet
(improved suction)
conditions.
Belt-driven pumps designed to operate in
Belt-driven pumps places with limited space or where no
electrical power is available.
Pumps for CRN pumps designed for applications
pharmaceutical and requiring the sterilization and CIP capability of
biotechnological pipes, valves and pumps. (CIP = Cleaning-In-
applications Place).
77
13 CR, CRI, CRN
78
CR, CRI, CRN
14
14. Submittal data
Submittal data
CR, CRI, CRN Company name:
Prepared by:
Vertical Multistage Centrifugal Pumps Phone number: (____)
Fax number: (____)
Quote number:
Client Information
Project title: Client name:
Reference number: Client number:
Client contact: Client phone number: (____)
Location Information
For: Unit:
Site: Service:
Address: City: State: Zip Code:
Application Information
Operating Conditions Pumped Fluid
Fluid type:
Pump Information
Model Information from Type Key and Codes: ----> (Example: CR 5-10 A-FGJ-A-E-HQQE )
Quantity Required:
Minimum required flow: NPSH required at duty point:
Motor Information
Hp: Phase: Voltage: Enclosure:
Additional Information
79
14 CR, CRI, CRN
80
CR, CRI, CRN
15
15. Quotation text
Quotation text
CR, CRI, CRN
Vertical, non-self-priming, multistage, in-line, centrifugal pump for installation in pipe systems and mounting on a
foundation.
The pump has the following characteristics:
– Impellers and intermediate chambers are made of AISI __________________ Stainless steel
– Pump head and base are made of __________________
– Power transmission is via cast iron split coupling.
– Pipework connections is via ___________________
– The motor is a ___________________ -phase AC motor
Technical
Rated flow: _______________________ gpm
Rated head: _______________________ Feet
Minimum liquid temperature: _______________________ °F
Maximum liquid temperature: _______________________ °F
Type of shaft seal: _______________________
Materials
Material, pump housing: _______________________
Material, shaft: AISI____________________ Stainless Steel
Material, impeller: AISI____________________ Stainless Steel
Material, sleeve: AISI____________________ Stainless Steel
Material, seal metal: AISI____________________ Stainless Steel
– seal face: _______________________
– seal face _______________________
– seal elastomer: _______________________
Installation
Maximum ambient temperature: _______________________ °F
Max. pressure at stated temp.: _______________________ PSI / °F
Standard, pipe connection: _______________________
Size, pipe connection: _______________________
Rated pressure, pipe connection: _______________________ PSI
Frame size for motor: _______________________ NEMA
Electrical data
Motor type: _______________________
Rated power (P2): _______________________ Hp
Frequency: _______________________ Hz
Rated voltage: _______________________ V
Rated current: _______________________ A
Service factor: _______________________
Starting current: _______________________ A
Rated speed: _______________________ RPM
Full load motor efficiency: _______________________ %
Insulation class: _______________________
Additional
Gross weight: _______________________ Lbs.
Shipping volume: _______________________
Model: _______________________
81
15 CR, CRI, CRN
82
CR, CRI, CRN
16
16. Further product information
Catalog
Literature
Service
83
16 CR, CRI, CRN
Further product information
Sizing 0 1
Replacement
CAD drawings
2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 220,000 Grundfos products
in more than 30 languages.
The program contains the same features and
functions as WebCAPS, but is an ideal solution if no
internet connection is available.
WinCAPS is available on DVD and updated once a
year.
84
CR, CRI, CRN
16
Grundfos GO
GET IT ON
Subject to alterations.
85
86
87
© Copyright Grundfos Holding A/S
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
L-CR-PG-001
98446676 0414
ECM: 1134614
Grundfos Canada
2941 Brighton Road
Oakville, Ontario L6H 6C9 Canada
Phone: +1-905-829-9533
Fax: +1-905-829-9512
www.grundfos.ca
Grundfos México
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L. Mexico
Phone: 011-52-81-8144 4000
Fax: 011-52-81-8144 4010
www.grundfos.mx