Sie sind auf Seite 1von 3

LICENCE

for
AS/NZS 3760:2010/Amdt 2:2012 In-service safety inspection and testing of electrical equipment

Licensee: anhphuc.ckcn@gmail.com
Date: 26-Feb-2018

Licence Agreement

This is an agreement between the end user of the Product ("Licensee") and SAI Global Limited, Level 37, 680 George Street, Sydney NSW
2000 AUSTRALIA, ABN 67 050 611 642.

1. Definitions and Interpretations

Australian Standards means Australian Standards and includes Joint ISO/Australian Standards, Joint NZ/Australian Standards, current Draft
Australian Standards, and amendments to Australian Standards.

Concurrent Users means the maximum number of people able to access the Product at any one time, and is limited to the number of Licences
purchased.

ISO Standards means Standards published by the International Organization for Standardization (ISO), for which SAI Global is an authorised
distributor.

IEC Standards means Standards published by the International Electrotechnical Commission (IEC), for which SAI Global is an authorised
distributor.

Internal use means use of the Product within the Licensee’s organization.

Licence means the right to access and use the Product.

Licensee means the purchaser and user of the Product.

Product means Australian Standards, ISO Standards and IEC Standards ordered and purchased through the infostore, and downloaded as
electronic PDF files.

2. Product Availability

2.1. The Product is available via the World Wide Web through the use of a web browser. Documents are provided as PDF files, viewable through
the use of the latest version of Adobe Reader®.

3. Licence Agreement

3.1. By using the Product the Licensee agrees to be bound by the Licence Agreement for the Product.

3.2. The Licensee is granted a non-exclusive and non-assignable Licence to use the Product.

3.3. Licensees are permitted to use the Product the following extent:
To read the full licence agreement, simply click within the red box above and scroll through with your cursor
3.3.a. PDF (Personal Use) Format - Purchasers of personal user Licences for the PDF format of the publication may locally install and use the
publication on the number of individual computers corresponding to the Quantity specified in the SAI Global Infostore order. Licensees are
permitted to print once for Internal use limited to the Quantity specified in the SAI Global Infostore order only (excludes electronic pads of forms).
Licensees are permitted to store one electronic version of the publication for backup purposes.
For reproduction of the PDF (Personal Use) publication or portions thereof, and for which are outside the circumstances included in this
Learnmust
agreement, permission about LexConnect,
be sought AllSAI
in writing from Jurisdictions, Standards
Global, Copyright referenced in Australian legislation
Officer at copyright@saiglobal.com.

Know when
3.3.b. PDF (Copy/Paste) Format -aPurchasers
Standardof has changed
personal user Licences for the PDF(copy/paste) format of the publication may locally install and
use the publication on the number of individual computers corresponding to the Quantity specified in the SAI Global Infostore order. Licensees
are permitted to Visit ourforstore
print once touse
Internal find more
limited Publications
to the Quantity specified in the SAI Global Infostore order only (excludes electronic pads of
forms). Licensees are permitted to store one electronic version of the publication for backup purposes.
Licensees are permitted to copy and paste up to 50% of the content from the publication into their organisation's internal documents for internal
use only.
For reproduction of the PDF (Copy/Paste) publication or portions greater than 50%, or for which are outside the circumstances included in this
agreement, permission must be sought in writing from SAI Global, Copyright Officer at copyright@saiglobal.com.

3.3.c. PDF (Networkable) Format - Purchasers of network Licences for the PDF (Networkable) format of the Publication may install and use the
AS/NZS 3760:2010/Amd 2/December 2012

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND

Amendment No. 2
to
AS/NZS 3760:2010
In-service safety inspection and testing of electrical equipment

CORRECTION
Licensed to anhphuc.ckcn@gmail.com on 26-Feb-2018. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited.

The 2010 edition of AS/NZS 3760 is amended as follows; the amendments should be inserted in the appropriate
place.
SUMMARY: This amendment applies to the Foreword, Clauses 2.3.3.2 and 2.3.3.4, and Appendices E and F.
Published on 21 December 2012.
Approved for publication in New Zealand by the Minister of Energy and Resources on 29 November 2012 and by the
Standards Council of New Zealand on 30 November 2012. Approved for publication in Australia on behalf of the
Council of Standards Australia on 3 December 2012.

This amendment takes effect from the date of publication.


Get permission to copy from or network this publication www.saiglobal.com/licensing

Page 4

FOREWORD Insert a new 4 th paragraph as follows:

This Standard is not intended to demonstrate that equipment complies with the safety Standard
appropriate to the equipment.

Amendment No. 2, December 2012

Page 15

2.3.3.2 Replace the NOTE with the following:

NOTE – For equipment that contains single phase motors, or if an insulation test fails due to
the presence of internal components such as LEDs, the leakage current test is the preferred
option.

Amendment No. 2, December 2012

ISBN (Print) 978-1-86975-620-8


ISBN (PDF) 978-1-86975-621-5 COPYRIGHT © Standards New Zealand and Standards Australia
Page 17

2.3.3.4 Replace the first paragraph with the following:

RCDs shall be tested in accordance with Appendix H. The maximum tripping time shall not
exceed the values in Table 3.

RCDs which are permanently wired to terminals in equipment shall be tested using the RCD test
button only, observing the operating time which should be ‘without undue delay’. In case of doubt,
use an external timing circuit, capable of detecting the test current start and finish, to measure
disconnect time which shall be not more than 150 ms for a 30 mA RCD and 40 ms for a 10 mA
RCD. (The test button current is assumed to be 2 times the rated residual current.)
Licensed to anhphuc.ckcn@gmail.com on 26-Feb-2018. 1 user personal license only. Copying, copy/pasting, storage & distribution or use on network prohibited.

Amendment No. 2, December 2012

Page 17

2.3.3.4 Delete existing NOTE 2 and renumber existing NOTE 3 as NOTE 2.

Amendment No. 2, December 2012

Page 31
Get permission to copy from or network this publication www.saiglobal.com/licensing

E3.3 Replace ‘ 2.3.3.2 (b)’ with ‘E2.2 (b)’

Replace the NOTE with the following:

NOTE –
(1) Figure E5 shows the insulation resistance testing of an EPOD.
(2) For EPODs that feature an LED indicator connected between the active conductor and
earth, if the EPOD fails the insulation resistance test the integrity of the insulation should
be confirmed by the leakage current test.

Amendment No. 2, December 2012

Page 35

F3(b) NOTE

Replace ‘Figure F2’ with ‘Figure F3’.

F3(d) NOTE

Replace ‘Figure F3’ with ‘Figure F2’.

Amendment No. 2, December 2012

Page 41

H3.1 NOTE (6) To clarify that the assumed value of the test button current is twice the
rated residual current and not 200 times:

Replace ‘200 % x’ with ‘2 times the’.

Amendment No. 2, December 2012