Specification

AFA Aluminium High-Speed Folding Door

Model
Aluminium high-speed folding door
Designation
AFA

Size of structural opening


Fitting to the wall:
Width (LB) max. 4490 (RAM 5000)
Height (LH) max. 4500 (RAM 4490)
Fitting between walls:
Width (LB) max. 5020 (RAM 5000)
Height (LH) max. 4850 (RAM 4490)
 width: _______________ mm
 height: _______________ mm

Number of door leaves


• Four-leaf
° Double-leaf

Folding arrangements
• 2:2
° 2:0
° 0:2

Opnening angle
90°

Clearances
At top and sides
• Headroom 350 mm
• Fitting to the wall, internal per side 255 mm
° Fitting to the wall, external (with cladding) per side 255 mm
° Fitting between walls, internal per side 265 mm
° Fitting between walls, external (with cladding) per side 265 mm

Speed
• Opening speed: approx. 0.5 m/s per side
• Closing speed: approx. 0.4 m/s per side

Wind pressure
Depending on the size up to approx. 40 km/h

Design
Cantilever construction with door leaves made of aluminium
extrusions (frame material group 3 = non thermally-insulating).
Butt joints screw-connected.
Side frame 60 x 140 mm
Overall thickness: 54 mm
Frame width: 224/112 mm
Seals
Glass rebate seals
Continuous pre-laid tape on the outside (sealed in the corners), glazing wedge on the inside.

Brush seal
At the top and bottom, replaceable

Seafety fatures
• 2 closing edge safety devices on the main closing edge
• Hollow chamber profiles (EPDM) as trap protection along the vertical closing edges
• One-way photocell for monitoring the traffic path

Horizontal rails
107 mm high

Base section
127 mm high

Hardware
Aluminium, 3-part hinges with plastic bushes, screwed on, 3 each on outside or inside.

Door leaf infills


• Acrylic double panels, clear, 18 mm
° Acrylic double-moulded units, 16 mm
° Polycarbonate/acrylic double panes, clear, 18 mm
° Polycarbonate single panes, clear, 6 mm
° Smooth aluminium panels (E6/EV1), PUR insulated, 24 mm

Wicket pass door


With safety contact, on request

Side door
Matching the design of the main door, on request

Surface
Fascia frame, door leaf frame, horizontal rails
• Stained/natural finish (E6/EV1)
° Powder-coated in Traffic White (based on RAL 9016)
° Powder-coated RAL to choice
• Frames and guide rail galvanized

Fitting
• Plug-and-screw fixing
• Welding
• Threaded bars

Operator FTA 400


Electromechanical, centrally positioned.
Emergency release in the event of a power failure or service operation via Bowden cable.
Motor and control unit pre-cabled, cable 7 m long.
Connecting voltage: 230 V
Fuses (characteristic K): 16 A
Protection category: IP 55
Earthing protection switch min. 0.5 A

Control unit B 500 F


Programmable frequency inverter control for a fluent door action and non-wear, precision-controlled
run-in at the limit stops.
Cable: 0.5 - 1.5 kW
Protection category: IP 54
Button ÒOPEN-STOP-CLOSEÓ
Emergency-OFF button
Main switch, mains isolator switch
Control cabinet: 400 x 500 x 210 mm

Impulse generators
See page 8

Important note
When choosing the site for installing the control unit, it is important to ensure that the control unit will not be
exposed to direct sunlight or other atmospheric influences.
Also on manual operation of the door (power failure), it must be possible to see the door from the control unit
to allow dead man’s control via the membrane keyboard.

• Standard ° Choice of/on request Please complete