CYME

Power Engineering Software and Solutions

Power Cable
Ampacity Rating

Calculate ampacity and temperature


rise of power cable installations
The CYMCAP software The CYMCAP software is The validation of the results
dedicated to performing obtained with the CYMCAP
is dedicated to the ampacity and temperature rise software provides increased
calculation of ampacity and calculations for power cable confidence when upgrading
temperature rise calculations installations. Determining the existing power cable installations
maximum current power cables and designing new ones,
for power cable installations. can sustain without deterioration thus maximizing the benefits
The accuracy of the of any of their electrical from the considerable capital
properties is important for the investment associated with
software provides increased design of electrical installations. them.
confidence when upgrading
It addresses steady-state and
power cable installations transient thermal cable rating
and designing new ones; as per the analytical techniques
maximizing the benefits described by Neher-McGrath and
the International Standards IEC
from the considerable capital 287© and IEC 853©.
investment associated This software was developed
with them. It also helps jointly by Ontario Hydro (Hydro
increase system reliability One), McMaster University
and CYME International, under
and supports the proper the auspices of the Canadian
utilization of the installed Electricity Association.
equipment.
Power Cable Analytical Capabilities
• Iterative techniques based on
• All types of sheath bonding
arrangements for flat and
triangular formations are
Neher-McGrath and IEC-287©
Ampacity methods
supported with explicit
modeling of minor section
• Full compliance with lengths, unequal cable

Rating North American practice


and compliance with IEC
spacing, etc.

standards IEC 60287©, IEC Transient Analysis


60228©, IEC 60853©, etc. The program includes a Transient
Simulate the thermal • Detailed graphical Thermal Analysis feature which
behavior of power cable representation of virtually includes the following:
any type of power cable. This Ampacity given time and
installations. functionality can be used to

temperature
modify existing cables data
and enrich the cable library • Temperature analysis given
with new ones. This includes time and ampacity
single-core, three-core, • Time to reach a given
belted, pipe-type, submarine,
temperature, given the
sheathed, and armored cables
ampacity
• Different cable installation • Ampacity and temperature
conditions such as directly
analysis as a function of time
buried, thermal backfill,
underground ducts or duct • User-defined load profiles per
banks circuit
• Pipe-type cables directly • Multiple cables per installation
buried or in thermal backfill • Circuits can be loaded
• Independent libraries and simultaneously or one at a
databases for cables, duct- time
banks, load curves, heat
sources and installations
• Modeling of cables in air on
riser poles, groups of cables in
air, moisture migration, nearby
heat sources and heat sinks,
etc.
• Different cable types within
one installation
• Non-isothermal earth surface
modeling Cables on Riser Poles

• Cyclic loading patterns as per


IEC-60853©, including soil
dry out
• Multiple cables per phase
with accurate modeling of the
sheath mutual inductances
which greatly influence
circulating current losses and
thus de-rates the ampacity of
cables Heat Source and Heat Sink

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
© 2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 028 EN All other trademarks are property
November 2014 of their respective owners.

Das könnte Ihnen auch gefallen