Data sheet

__________________________________________________________________________________________________________________

BX-SOL
Loop Sirene
SecuriLine eXtended
The BX-SOL can be connected directly to the fire alarm line. The
volume can be set to either “Low” or “High” and the tone type is set
via the fire alarm control panel, even during ongoing operation,
depending on the event.

The siren is available in the colours red and white and corresponds
to environmental category type A pursuant to EN 54-3, suitable for
interior rooms..

The siren fulfils EN54-3 and EN54-17.

It meets the specifications of SecuriLine eXtended for operation on


the ring circuit of the Securiton fire detection system SecuriFire
and SecuriPro. Fig. 1 BX-SOL
This product is not yet released for SecuriPro!
__________________________________________________________________________________________________________________

Description X1 SecuriLine eXtended


The BX-SOL can be directly connected to the fire detector line Se-
curiLine eXtended of the fire alarm system SecuriFire Terminal Designation Description
1000/2000/3000 and SecuriPro. 1 L1 Data A
2 GND GND A
The Loop Siren BX-SOL is an addressable alarm unit for the 3 GND GND B
acoustic alarmin of a fire alarm in indoor applications 4 L2- Data B
The Loop Siren unit BX-SOL can be connected directly to the fire 5 SHLD Shield
alarm line, mixed with other participants such as manual call points 6 SHLD Shield
or automatic fire detectors.

The different tone type are defined via software DIP-switch


(SecuriFire: 4, SecuriPro: 3). DIP for the setting of the volume
Switch 1 (VOL): ON = High (default)
OFF = Low
The required volume „Low" or „High" is set either via software or
Switch 2 (FLASH) No function
via DIP switch. (SecuriFire via Software, the DIP-switch has no
function; SecuriPro: via DIP-switch).
Planning
The module includes a short-circuit isolator. In the event of wire Acoustic loop units must not be used in combination
breakage or short-circuit this functionality ensures that the fault is with controlling of fire extinguishing system!
localised and that operation of the ring circuit remains fully func-
tional.
Based on the current consumption, these conditions must be con-
Interface sidered:
View with cover removed The quantity of BX-SOL units that can be connected is dependent
on how many are combined with other loop technology devices, on
the cabling used (length and diameter) and the volume set for the
BX-SOL BX-SOL sirens.
L1
GND
SHLD

ON
As power is supplied exclusively over the loop circuit, a pure siren
1 2
loop has these restrictions:
VOL
FLASH

- 15 units BX-SOL when the volume is set to „High“


SHLD
SHLD
- 30 units BX-SOL when the volume is set to „Low“
L2
GND If other devices are connected on the same loop circuit, then the
GND
quantity of loop sirens must be adjusted accordingly. A precise
L1
power consumption calculation must be carried out.
For SecuriFire, a power calculation tool is available.
SHLD

GND
L2

Depending on the set volume, the current consumption can vary.


This has to be considered when making the loop length check and
also the power calculation.
Fig. 2

Securiton AG Alpenstrasse 20 3052 Zollikofen Schweiz T 800 999 en 1/2


Data sheet

Programming Installation
A SecuriFire software documentation in planned for programming 1. In order to remove the siren from the socket, press the
and planning. enclosed tool in the provided opening and draw the siren
from the socket..
Volume setting
The volume can be set individually per loop siren.

SecuriFire:
Selection of the volume High/Low via SecuriFire Studio.
The DIP-switch 1 has no function.

SecuriPro:
Selection of the volume High/Low via DIP-switch 1, see chapter In-
terface
Fig. 3: Opening the housing
Tone type setting
SecuriFire and SecuriPro: 2. Drill the mounting holes. Fix the socket on the mounting
The tone type can be set individually per loop siren via software. surface. Connect the wires to the terminal. Insert the si-
Furthermore, the tone type can be programmed depending of the ren in socket again.
type of event.
Rem. The tone “Swedish” is not available, when the siren is in the
mode “BA-SOL” on a SecuriLine (SecuriPro).

Synchronisation
A synchronisation for the loop sounder BX-SOL is carried out in
combination with SecuriFire, but not with SecuriPro.

Grooves for locating the cable entry holes


Fig 4: Drilling plan socket and closing the housing
Article numbers / spare parts
Brief description Article number CH Article number
BX-SOL-R (red) 239798 20-2100008-01-02
BX-SOL-W (white) 239780 20-2100008-02-02

Technical data
Operating voltage: 12 to 30 V DC
Power consumption: (all tone types)
Idle mode 500 µA
„Low“ volume 2,3 mA @ 24VDC
„High“ volume 4,7 mA @ 24VDC
Volume (all tone types) @ 24 V DC
„Low“ volume 89 dB +/- 3 dB @1m
„High“ volume 99 dB +/- 3 dB @1m
Tone types
DIN-tone (DIN 33404-3) 1200 ~ 500 Hz
Slow Whoop (EN 2575) 500 ~ 1200 Hz
Permanent tone (Pulse programmable) 990 Hz
“Swedish” tone (150ms on, 150ms off) 660 Hz
Protection class IP 21c
Ambient temperature - 10 °C to + 55 °C
Dimensions (D x H) 108 x 91 mm
Terminal (screw able) max. 2.5 mm2
Weight ca.230 g
Case material ABS
Case colour white / red similar RAL 9003 / similar RAL 3001
VdS Approval (EN 54-3, EN54-17) G210086
CPD-Certificate (EN 54-3, EN54-17) 0786-CPD-20986

2/2 T 800 999 en, 03.01.2011 Rd BX-SOL


First edition: 03.01.2011 Rd
The product specifications contained in this document are subject to change without notice.
© Copyright by Securiton