2. Complexity of the canal petals is insufficient. The ROTATION OF THE concerned instrument INSTRUMENT IN A CANAL Based on X-rays, must be set aside for a CURVE DURING A determine the working simpler treatment, or MAXIMUM OF 10 SECONDS length ( WL ) discarded once all of the AT 600 RPM. By superimposing the petals have been used. SMD¯ gauge and the X- Either a new instrument Method of using FKG RaCe; ray, look for the smallest or one with a sufficient Most continuous radius in the canal. Based number or petals must be rotation endodontic upon the obtained value, chosen to treat the canal systems currently the canal will be classified available on the market in one of the three are only adapted to the following "Crown-down" technique (this is in order to reduce Radius greater than 25 the risk of screwing on/ mm = Simple canal blocking / rupture).On the Radius between 11 mm contrary, the intrinsic and 25 mm = Medium qualities of the FKG RaCe canal instruments leave the Radius between 8 mm practitioner entirely free and 11 mm = Difficult to choose the technique canal to use for each treatment, in function with the 3. SMD" flange ---- morphology of each canal Depending upon the and the desired working chosen method of comfort. With this is treatment and the degree mind, FKG has put a of difficulty of the canal complete set of RaCe (simple, medium or instruments at the difficult), the SMD¯ practioner's disposal decrementation table will (generally 3 or 5 indicate the number of instruments suffice for the petals required for treatment of a canal). carrying out the Preparation treatment. 1st case: the After opening the SMD¯ flange has a pulpal chamber and sufficient number of localizing all of the canals petals and the treatment (for example, with the may be carried out 2nd help of FKG F-SEARCH case: instruments), the reaming manual recapitulation Use a motor/contra- of the canal may begin. with an FKG ERGOFLEX¯ angle ensemble with the After determining the (H type, NiTi) will allow possibility to adjust the working length and one to arrive at the end of working speed. Otherwise estimating the the obstacle. The have your apparatus morphology of the canal, sequence may then pick calibrated. Modern the straight coronal part up at the place where it motors offer more and of the canal (first third/till was interrupted. The more often the possibility first half, depending upon sequence will be to also adjust the working the case) will be splayed continued until the torque. This is an added as much as possible in desired ream is obtained. security against certain direction of the apex, with In most cases, complete kinds of manipulation the help of the FKG PRE- execution of the canal errors. However, since the RaCe. reaming will require no FKG RaCe¯ instruments Reaming more than 2 to 5 do not have the screwing instruments. Use of the on problem, a The working length SMD will ensure optimal conventional apparatus is which has been previously security throughout the perfectly adequate. determined will be sequence. transferred to the first 2. Apical pressure - FKG RaCe¯, which will be Using FKG RaCe in Extremely gentle conducted as quickly as Calcified or Very Narrow In order to give a possible to the desired Canals : better idea of the position by brief and very For these very recommended pressure, light pressure in a back difficult cases, FKG take into your hand an and forth movement. In recommends two RaCe FKG instrument, for every case, the ideal instruments, the no. 015 example RaCe.02 no 025 rotation speed is situated and 020 in taper 2%. (red ring), put the point between 300 and 600 Thanks to squared cross- into contact with a rpm. The work time for section, they offer smooth surface, and each instrument is not to increased resistance and foramen angle of exceed 5 to 10 seconds. allow one to successfully approximately 45° Never leave an instrument treat most difficult canals. between the contact in stationary rotation in a point and the instrument, curved canal but always Golden rule! Never force then press just until the give it a back and forth the way! instrument begins to movement. In the case The 7 keys to success bend. The force used for where progress is difficult, this operation the practitioner must not 1. Working speeds-300 corresponds to the ideal try to force the passage. A to 600 rpm apical pressure. 5, 2007
3. Noise - Overload very useful in narrow and
warning complex canals. A clacking of the instrument warns the 6. Working time practitioner that he or she 5 to 10 seconds per is using too much apical instrument FKG RaCe¯ pressure. Let the instruments are instrument work at its characterized by their own speed. optimum cutting efficiency. This quality 4. Movement - Brief and essentially allows one to quick back and forth shorten the working time movements and to therefore reduce Avoid all prolonged metal fatigue. stationary rotation in a curved canal. Sooner or 7. Metal fatigue - FKG - later, the phenomenon of SMD method metal fatigue will provoke Thanks to the SMD¯ the rupture of an FKG is the sole company instrument. to offer a method of controlling metal fatigue 5. Progression - Never that is at the same time force the way simple and efficient. After Avoid all forced having determined the passages. The safety tip level of complexity of the ensures perfect guiding canal to be treated, the and centering of the SMD¯ allows one to instrument in the canal. If simultaneously record the the instrument no longer "life" of the instrument as advances, do not insist. well as to save this Pull it out of the canal, information (even when recapitulate manually the instrument is mixed with the help of an up with other tools) until ERGOFLEX¯ H NiTi n°10, it is finally discarded. then pick up the mechanical work again with the last FKG RaCe¯ instrument used. The instruments FKG RaCe¯ n° 015 and 020 can be very