1. Preliminaries (WL).

the number or remaining ONE USE = CONTINUOUS


2. Complexity of the canal petals is insufficient. The ROTATION OF THE
concerned instrument INSTRUMENT IN A CANAL
Based on X-rays, must be set aside for a CURVE DURING A
determine the working simpler treatment, or MAXIMUM OF 10 SECONDS
length ( WL ) discarded once all of the AT 600 RPM.
By superimposing the petals have been used.
SMD¯ gauge and the X- Either a new instrument Method of using FKG RaCe;
ray, look for the smallest or one with a sufficient Most continuous
radius in the canal. Based number or petals must be rotation endodontic
upon the obtained value, chosen to treat the canal systems currently
the canal will be classified available on the market
in one of the three are only adapted to the
following "Crown-down" technique
(this is in order to reduce
Radius greater than 25 the risk of screwing on/
mm = Simple canal blocking / rupture).On the
Radius between 11 mm contrary, the intrinsic
and 25 mm = Medium qualities of the FKG RaCe
canal instruments leave the
Radius between 8 mm practitioner entirely free
and 11 mm = Difficult to choose the technique
canal to use for each treatment,
in function with the
3. SMD" flange ---- morphology of each canal
Depending upon the and the desired working
chosen method of comfort. With this is
treatment and the degree mind, FKG has put a
of difficulty of the canal complete set of RaCe
(simple, medium or instruments at the
difficult), the SMD¯ practioner's disposal
decrementation table will (generally 3 or 5
indicate the number of instruments suffice for the
petals required for treatment of a canal).
carrying out the Preparation
treatment. 1st case: the After opening the
SMD¯ flange has a pulpal chamber and
sufficient number of localizing all of the canals
petals and the treatment (for example, with the
may be carried out 2nd help of FKG F-SEARCH
case:
instruments), the reaming manual recapitulation Use a motor/contra-
of the canal may begin. with an FKG ERGOFLEX¯ angle ensemble with the
After determining the (H type, NiTi) will allow possibility to adjust the
working length and one to arrive at the end of working speed. Otherwise
estimating the the obstacle. The have your apparatus
morphology of the canal, sequence may then pick calibrated. Modern
the straight coronal part up at the place where it motors offer more and
of the canal (first third/till was interrupted. The more often the possibility
first half, depending upon sequence will be to also adjust the working
the case) will be splayed continued until the torque. This is an added
as much as possible in desired ream is obtained. security against certain
direction of the apex, with In most cases, complete kinds of manipulation
the help of the FKG PRE- execution of the canal errors. However, since the
RaCe. reaming will require no FKG RaCe¯ instruments
Reaming more than 2 to 5 do not have the screwing
instruments. Use of the on problem, a
The working length
SMD will ensure optimal conventional apparatus is
which has been previously
security throughout the perfectly adequate.
determined will be
sequence.
transferred to the first 2. Apical pressure -
FKG RaCe¯, which will be
Using FKG RaCe in Extremely gentle
conducted as quickly as
Calcified or Very Narrow In order to give a
possible to the desired
Canals : better idea of the
position by brief and very
For these very recommended pressure,
light pressure in a back
difficult cases, FKG take into your hand an
and forth movement. In
recommends two RaCe FKG instrument, for
every case, the ideal
instruments, the no. 015 example RaCe.02 no 025
rotation speed is situated
and 020 in taper 2%. (red ring), put the point
between 300 and 600
Thanks to squared cross- into contact with a
rpm. The work time for
section, they offer smooth surface, and
each instrument is not to
increased resistance and foramen angle of
exceed 5 to 10 seconds.
allow one to successfully approximately 45°
Never leave an instrument
treat most difficult canals. between the contact
in stationary rotation in a
point and the instrument,
curved canal but always
Golden rule! Never force then press just until the
give it a back and forth
the way! instrument begins to
movement. In the case
The 7 keys to success bend. The force used for
where progress is difficult,
this operation
the practitioner must not 1. Working speeds-300
corresponds to the ideal
try to force the passage. A to 600 rpm apical pressure.
5, 2007

3. Noise - Overload very useful in narrow and


warning complex canals.
A clacking of the
instrument warns the 6. Working time
practitioner that he or she 5 to 10 seconds per
is using too much apical instrument FKG RaCe¯
pressure. Let the instruments are
instrument work at its characterized by their
own speed. optimum cutting
efficiency. This quality
4. Movement - Brief and essentially allows one to
quick back and forth shorten the working time
movements and to therefore reduce
Avoid all prolonged metal fatigue.
stationary rotation in a
curved canal. Sooner or 7. Metal fatigue - FKG -
later, the phenomenon of SMD method
metal fatigue will provoke Thanks to the SMD¯
the rupture of an FKG is the sole company
instrument. to offer a method of
controlling metal fatigue
5. Progression - Never that is at the same time
force the way simple and efficient. After
Avoid all forced having determined the
passages. The safety tip level of complexity of the
ensures perfect guiding canal to be treated, the
and centering of the SMD¯ allows one to
instrument in the canal. If simultaneously record the
the instrument no longer "life" of the instrument as
advances, do not insist. well as to save this
Pull it out of the canal, information (even when
recapitulate manually the instrument is mixed
with the help of an up with other tools) until
ERGOFLEX¯ H NiTi n°10, it is finally discarded.
then pick up the
mechanical work again
with the last FKG RaCe¯
instrument used. The
instruments FKG RaCe¯
n° 015 and 020 can be
very