Sie sind auf Seite 1von 38

pg220 7/29/05 8:36 AM Page 1

Level
Table of Contents
Introduction to Level Controls . . . . . . . . . . . . . . . . . . . . . . .221 Float/Level Switches pgs 224-235
Introduction to Level Applications . . . . . . . . . . . . . . . .222-223
Series L4 Flotect® Float Switch . . . . . . . . . . . . . . . . . . . . . .224
Series L6 Flotect® Liquid Level Switch . . . . . . . . . . . . . . . .225
Model L8 Flotect® Liquid Level Switch . . . . . . . . . . . . . . . .226
Series L10 Flotect® Mini-Size Level Switch . . . . . . . . . . . . .227
Series CFS Cable Float Switch . . . . . . . . . . . . . . . . . . . . . .228
Series FSW Free-Floating Level Switch . . . . . . . . . . . . . . .228
Model F7-MLK Multi-Level Switch Kit . . . . . . . . . . . . . . . . .229
Model F7-MLK2 Multi-Level Switch Kit . . . . . . . . . . . . . . . .229
Series F7 Level Switches - Vertical . . . . . . . . . . . . . . . . . . .230
Series F7 Level Switches - Horizontal/Specialty . . . . . . . . .231
Level

Series F7-MM Miniature Multi-Station Level Switch . . . . . .232


Series F7-MQ Quick-Ship Multi-Station Level Switch . . . .233
Series F7-MS Multi-Station Level Switch . . . . . . . . . . . . . .234
Model OLS Optical Level Switch . . . . . . . . . . . . . . . . . . . . .235
Series 123 Cast Iron Chamber - Water Level Control . . . . .236 Sensors/Level Controls pgs 236-239
Series 102 Flanged Chamber Type Level Control . . . . . . . .236
Series 500 Insertion Type Level Control . . . . . . . . . . . . . . .237
Series 75 Torque Tube Type Level Control . . . . . . . . . . . . .237
Series 201 Side Mounted-Chamber Type
Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
Series 391 Side Mounted-Chamber Type
Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238
Series B-190 Liquid Level Switches - Controls . . . . . . . . . .239
Series GS Gap Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239
Model CLS1 Capacitance Level Switch . . . . . . . . . . . . . . .240
Series RFC RF Capacitance Level Switch . . . . . . . . . . . . .240
Series RF Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
Model DPL110 Dual Point Level Switch . . . . . . . . . . . . . . .241
Series LLC Conductivity Controller . . . . . . . . . . . . . . . . . . .242
Model DBLM Mini-Bin Dry Bulk Level Monitor . . . . . . . . . .243
Explosion-Proof Ultra MagTM Level Switches . . . . . . . .244-245
Series PLS Paddle Level Switch . . . . . . . . . . . . . . . . . . . . .246
S-DTM & SliquidTM Liquid Level Switches . . . . . . . . . . . . . . .247 Level Transmitters pgs 248-252
Series CLT Continuous Level Transmitter . . . . . . . . . . . . . .248
Model CRF Continuous Level Transmitter . . . . . . . . . . . . . .249
Series PLT Piezoresistive Level Transmitter . . . . . . . . . . . .249
Series UT Ultrasonic Level Transmitter . . . . . . . . . . . . . . . .250
Series SLT Submersible Level Transmitter . . . . . . . . . . . . .250
Series SBLT Submersible Level Transmitter . . . . . . . . . . . .251
Series SPT Submersible Pressure Transmitter . . . . . . . . . .251
Series PBLT Submersible Level Transmitter . . . . . . . . . . . .252
Series A-900 & A-901 1/4 DIN Control Enclosures . . . . . . .252
Series MPC Pump Controller . . . . . . . . . . . . . . . . . . . . . . .253
Series PCP Relay/Controller/Power Supply . . . . . . . . . . . .254
Series MVR Mini View-Rite Level Indicator . . . . . . . . . . . . .255
Series VR View-Rite Level Indicator . . . . . . . . . . . . . . . . . .256
Series TLI Tank Level Indicator . . . . . . . . . . . . . . . . . . . . . .257
Series PS Proximity Sensors . . . . . . . . . . . . . . . . . . . . . . . .257

220 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg221 7/29/05 8:36 AM Page 1

Introduction to Level Controls


Most of the devices featured in this section use the magnetic attraction or repulsion system of operation. This rugged electro-me-
chanical design has proven itself for more than 50 years and millions of heavy duty applications. The electro-mechanical system con-
sists of an attractor of magnetic material, usually 430 SS, or a magnet inside the control and a movable magnet outside the device.
As the attractor moves in or out of the magnetic field the magnet moves toward or away from the attractor. The magnet is attached
to one or more snap action or mercury switches. As the magnet moves it pivots and operates the switch assembly to either make or
break one or more electrical contacts. This switch action performs the task of operating equipment, alarms, shutdowns, and/or re-
ports such functions to a computer or central location. Controls featuring this magnet operated system can be used at temperatures
up to 800°F (425°C) and pressures up to 1750 psig (121 bar). Liquid level controls are available to handle fluids from water to more
aggressive liquids requiring all 316 SS construction. Dry bulk controls can handle materials from carbon black to soybean flour. Elec-
trical contacts of SPST, SPDT, or DPDT configuration are provided to accommodate applications from 12 amperes AC, 10 amperes
DC, to milliampere requirements of high technology low current, low voltage intrinsically safe or “dry” circuits. General purpose,
weatherproof or explosion-proof enclosures protect the electrical switch assemblies from the environment.
Dwyer Dry Bulk or Liquid Level controls are designed to perform two functions.

Level
A. To maintain a level. This task is usually completed by using a control with a wide deadband, or two fixed deadband controls and a
holding relay. Thus when the level of a liquid or dry bulk material reaches a pre-determined high (or low) point a pump is shut off or
turned on. This cycle is repeated continuously such as in a sump, tank, lubrication equipment, bin or other pressurized or non-pres-
sured vessel.
B. To monitor a safe level or detect a not-to-exceed level - that is to act as an alarm, or shut down, or both. This can be either high or
low functions or both. This is accomplished by using a control with a fixed deadband. There are a great variety of controls suitable
for this purpose.
There are basically 8 determining factors when selecting a control for a specific function.
1. Pressure 8. Method of attachment
2. Temperature A. External pipe mounted
3. Specific gravity or bulk density 1. threaded
4. Fixed or adjustable deadband 2. socket weld
5. Electrical requirement 3. flanged
6. Enclosure type B. Side mounted
A. General purpose 1. threaded
B. Weatherproof 2. flanged
C. Explosion-proof C. Top mounted
7. Media compatibility with wetted parts 1. flanged
2. threaded

If the control is to be externally mounted, can the chamber be a welded type such as for use with clean non-corrosive liquids or should
it be flanged so that the unit can be inspected and/or easily maintained? Welded chamber benefits are that they are usually less ex-
pensive than flanged controls and can be used with higher pressure and temperature. The disadvantage is that the unit cannot be
disassembled for cleaning or inspection. Flanged units can be disassembled but are more expensive and have lower pressure and tem-
perature capability.
Controls for top mounted service are generally capable of performing a greater variety of functions such as operating 1, 2 or 3 pumps,
providing high and low alarm or combining functions such as operating a pump and providing both high and low alarms in one unit.
Consult the factory or your nearest sales office if you cannot determine the best control for your application based on the informa-
tion in the technical guide.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 221
pg222 7/29/05 8:37 AM Page 1

Series MPC
Pump Fill Pipe
Mercoid pump®
Controller L4 High Limit
controller with Float
Switch
level transmitter
control pumps Indicator Lamps
in wastewater
lift stations. Inlet
Outlet L4
Control Float
Low
Panel Switch
Limit
Series PBLT
Level Transmitter

Submersible Pumps
Drain
Lift stations are used to transmit wastewater to the treatment facility.
Wastewater is transmitted by gravity feed so it has to be continually Reliable float switches monitor and control liquid
elevated to provide height to generate the flow. Lift stations are pits level.
located at points in the wastewater system to collect the wastewater
that usually have two submersible pumps. Wastewater in the lift sta- The W.E. Anderson® L4 float switch provides a simple, reliable
Level

tion is pumped out to a higher level from where it can flow on to the means for monitoring and controlling the level of a liquid in a
next lift station or to the treatment facility. The Mercoid® Series MPC large tank. In this holding tank application, the lower L4 indi-
pump controller is used with the Series PBLT level transmitter to con- cates to the operator that a tank fill cycle is required; the L4 can
trol the level in the lift station. The PBLT is a level transmitter that is also control the necessary valve or pump to provide an auto-
submersed in the tank and sends a linear output of the height of waste- matic fill cycle. When the level of the liquid reaches the upper
water above it. The MPC takes the height input and controls the pumps L4, the switch activates another indicator lamp or terminates
according to how it has been programmed. For a lift station, the pri- the automatic fill cycle. The L4 float switch in optional stainless
mary pump comes on when the tank hits a high level and turns off steel is recommended for level control of corrosive liquids,
when the level decreases to the set low level. The second pump is used while the lower cost standard brass L4 serves well in most
if the first pump cannot drain the station and comes on at a set higher water and oil applications.
level above pump 1. High and low level alarms, submersible pump seal
failure indication, pump over temperature protection, and pump alter-
ation all are built into the MPC.

Supply

Grain
Series PLS hopper level
Paddle controlled
Level Switch
Silo by Series
PLS Paddle
Level
Switch.
Series PLS
Paddle
Receiving Bin Level Switch Series PLS
Paddle
Transpor ter Level Switch

Proximity® Series PLS is used to indicate level sta-


tus in pneumatic conveying systems. Discharge

Pneumatic conveying systems use air to transport powder


and dry bulk solids through conveying lines. The air is pres-
surized by positive pressure or vacuum to move the product The supply of grain pneumatically conveyed to this dispensing
through the lines into and out of silos, transporters, and hopper is controlled by two Proximity® Series PLS paddle level
receivers. Typical applications have high and low level indica- switches. When the grain level falls to the low limit switch, the
tion in the storage bins to control the flow of product in or out. supply is turned on until the hopper fills to the level of the high
The PLS is perfect for level use in these storage bins. It has limit switch which turns off the supply. Since grain dust is explo-
a rotating paddle that is inserted into the bin. As the product sive, the explosion-proof Series PLS provides the required safe-
level builds up in the bin it stops the paddle from rotating and ty protection. The PLS is a paddle level switch and is not affect-
triggers the level output. The PLS is great for this application ed by the varying pressure in the hopper due to the cycling of
as it not affected by pressure changes in the bin. the pneumatic conveying system.

222 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg223 7/29/05 8:37 AM Page 1

Introduction to Mercoid, Anderson,


Proximity and Dwyer Level Controls
For Reliable Liquid or Dry Bulk Level Monitoring and Control
These typical applications may suggest ideas for solving your control problems:
In all systems it is essential that adequate liquid or dry bulk material exists in a pipeline or tank. Mercoid, Anderson, Proximity or
Dwyer switches provide the control and monitor function automatically, reliably and at moderate cost. These controls are widely used
in power generating stations, petroleum and chemical processing, pumping stations, air conditioning, heating, hot/cold water supply,
liquid or dry bulk transfer, water treatment, sumps and a great variety of industrial applications. The diagrams below suggest but a
few of the many applications that protect your motors, pumps, engines and processors.

Level
Mercoid displacer type
level controls, ideal for
controlling industrial
sump pumps.

Industrial sumps and other underground tanks are ideal applications for top mounted
Mercoid displacer type level controls. Easily installed, these controls use porcelain dis-
placers that do not float on the surface of liquids but are suspended on a coil spring and Proximity explosion proof Ultra-MagTM dry level switches provide highly reliable
cable. As the liquid in the tank reaches the level of the upper displacers their weight de- powder and bulk solids level monitoring capability with either the suspended (“S”)
creases by an amount equal to the liquid displaced allowing the spring to move the or flange (“F”) mounted models.
cable upward, actuating the switch and the pump is turned on. As the liquid level falls
below the upper displacers they move only a small amount, staying within the switch A magnetic coupling completely seals the switch(es) in the housing from the product
deadband until the liquid level falls to the center of the bottom displacer. At this point the and environment, assuring high reliability and enhanced safety. Alarm capability is de-
switch is deactivated stopping the pump. The pump will remain deactivated until the picted above. Side-mounted flange models are applicable for all bin levels. Top-of-the-
water level rises to the upper displacers, repeating the cycle. The displacers are not af- bin suspension mounted models for high and intermediate point level provide improved
fected by turbulence, pressure or chemicals and are excellent for tanks with viscous or sensitivity (in materials with bulk densities as low as 5 pounds per cubic foot), and en-
dirty liquids. The level differential is easily adjusted by repositioning of the displacers on hanced vertical adjustment capability compared to flange mounted models. Conve-
the 316SS cable. nient external adjustment screws simplify field setup. Material problems associated with
flange mounted models are solved by using suspended models. Elastomeric di-
aphragms are typically used in products such as fly ash, plastics, grain, powders,
foundry sand, cement, aggregate, coal metal chips and glass. For pneumatic (pressure)
applications, use of porous filter fabric diaphragms eliminates venting requirements due
to inherent ability to breathe. Many different diaphragm materials are available to fill the
wide variety of needs in the industrial market.

Switches control water level and tank pressure.

A hydro-pneumatic tank with a deep well pump maintains desired pressure in a water
system. The pump, however, delivers entrained air along with makeup water, requiring
periodic tank venting to prevent excess pressure buildup. As both water level and tank
pressure must be maintained, one side of the W.E. Anderson Duotect® pressure switch
is interlocked with the Anderson L-4 float switch via the control box. When tank pres-
sure falls below the preset system pressure due to water drawdown, the Duotect® Mercoid model 123 level controls provide high and low alarm on large deaerator
switch starts the pump and transfers control to the float switch. When the preset water tank.
level is reached, the float switch turns pump off. If entrained air has increased the pres-
sure beyond the limit set in the other side of the Duotect® pressure switch, after a time Liquid level in external piping equals level in tank. When level rises to high limit, float in
delay covering several normal cycles, the switch will open the solenoid valve and vent upper model 123 is lifted, actuating switch to sound high level alarm. When level drops
the tank down to proper pressure. to low limit, lower model 123 sounds low level alarm.

Important Note
The control hook-ups and sketches, and other application information shown in business. Neither Dwyer Instruments, Inc., nor the Mercoid, W.E. Anderson or
this catalog are generalized and abbreviated to present the basic application idea Proximity Divisions, shall be liable for loss, damage, or expense directly or in-
only. directly arising from the use of any product described herein. In no event shall
We believe this application information to be reliable, but it is intended for use any of these Companies be liable for direct, indirect, special, or consequential
by persons, at their own discretion, having technical skill and knowledge of the damages.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 223
pg224 7/29/05 8:37 AM Page 1

Series
L4 Float Switch
Magnetically Operated Switch, Leak Proof Body, Explosion-Proof ®
®

SWITCH BODY OF EXPLOSION PROOF


BRASS OR 316 HOUSING WITH 3/4
FLOAT OF 316 STAINLESS FLOAT ARM CONDUIT CONNECTION
AND BLOCK DEFLECTION STAINLESS STEEL
STEEL (STANDARD) STOP
316 STAINLESS 16 GA. LEADS,
STEELOR BRASS 1-1/2 NPT 6 [152.4] LONG
HINGE
PIN 2-1/2
1-5/8 [63.5] 3-11/32
[41.28] LOCK [84.93]
NUT MAGNET KEEPER
HEX FLOAT 3-15/16
CONNECTION 430 STAINLESS
STEEL [100.01]
5 6 5-31/32
[127] [152.4] [151.61]
8-5/32
19-5/32 [207.17]
[486.57]

Rugged and reliable the Flotect® L4 Level switch operates auto- SPECIFICATIONS
matically to indicate tank level. Perfect for starting or stopping pumps, Service: Liquids compatible with wetted materials.
opening or closing valves, or actuate level alarm signals. A unique mag- Wetted Materials:
Float and Rod: 316 SS.
Level

netically actuated switching design gives superior performance. There Body: Brass or 316 SS standard.
are no bellows, springs, or seals to fail. Instead, the free-swinging float Magnet Keeper: 430 SS standard, 316 SS or Nickel optional.
attracts a magnet within the solid metal switch body, actuating a snap Temperature Limits: 4 to 275°F (-20 to 135°C) standard, MT high temper-
switch by means of a simple lever arm. Float arm hinge design limits ature option 400°F (205°C) [MT option not UL, CSA, ATEX, or SAA].
Pressure Limit: Brass body 1000 psig (69 bar), 316 SS body 2000 psig (138
the arm angle to prevent vertical hangup. bar). Standard float rated 100 psig (6.9 bar). For other floats see options.
Enclosure Rating: Weatherproof and Explosion-proof. Listed with UL and
CSA for Class I, Groups C and D; Class II, Groups E, F, and G.
FEATURES ATEX 0344 II 2 G EEx d IIB T6 -20°C≤Tamb≤75°C
• Leak proof body machined from bar stock EC-Type Certificate No.: KEMA 03 ATEX 2383
• Choice of floats dependent on maximum pressure and specific SAA: Exd II C T6 (T amb = 60°C). IP66 C1 I, Zone I. Also FM approved.
Switch Type: SPDT snap switch standard, DPDT snap switch optional.
gravity Electrical Rating: UL, FM, ATEX and SAA models: 10A @ 125/250 VAC (V~).
• Weatherproof, designed to meet NEMA 4 CSA models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @
• Explosion-proof (listings included in specifications) 30 VDC (V ). MV option: 1A @ 125 VAC (V~); 1A res., .5A ind. @
• Installs directly and easily into tank with a thredolet or flange (see 30 VDC (V ). MT option: 5A @ 125/250 VAC (V~). [MT and MV option not UL,
CSA, FM, ATEX or SAA].
application drawings) Electrical Connections: UL and CSA models: 16 AWG, 6˝ (152 mm) long.
• Electrical assembly can be easily replaced without removing the ATEX and SAA unit: terminal block.
unit from the installation so that the process does not have to be Process Connection: 1-1/2˝ male NPT standard, 2-1/2˝ male NPT required
shut down. for optional floats.
Mounting Orientation: Horizontal installation standard, optional vertical top
• Horizontal installation or optional top mount vertical installation mount.
Weight: 4 lb 9 oz (2.07 kg).
APPLICATIONS Dead Band: 3⁄4˝ (19 mm) for standard float.
Specific Gravity: 0.7 minimum with standard float. For other floats see
• Direct pump control for maintaining level options.
• Automatic tank dump operations Agency Approvals: UL, CSA, FM, CE and ATEX.
• Control levels or provide alarms in sumps, scrubber systems,
hydro-pneumatic tanks, low pressure boilers, and various waste
water/sewage treatment processes

MODELS
Model No. Description
APPLICATION DRAWINGS FOR FLOTECT® FLOAT SWITCHES
L4 Brass body, side wall mounting
L4SS 316SS* body, sidewall mounting
1-1/2 THREDOLET ANSI RF THREADED
REDUCING FLANGE *316SS body and float with 430SS magnet keeper (wetted part).
CUT HOLE 1-15/16 [49] DIA.

Options for L4 Switches above — Add suffixes to model numbers


DPDT contacts, add suffix -D ...................................................................................
11-3/4 Gold Plated Contacts option for dry circuits, add suffix -MV
3/4 NPT [298.5]
(see electrical rating in specifications, no listings or approvals).....................................
High Temperature option rated 400°F (204°C), add suffix -MT
STANDARD INSTALLATION HORIZONTAL, FLANGE INSTALLATION (see electrical rating in specifications, no listings or approvals).....................................
Time Delay Relay option with 2 SPDT contacts, adjustable from 0-1
to 0-31 minutes. Add suffix -TRI (increasing flow) or
2-1/2 -TRD (decreasing flow) (no listings or approvals) ........................................................
CUT HOLE 3/4 NPT 316 SS Magnet Keeper option to replace standard 430 SS,
THREDOLET ANSI RF
2-7/8 [73] DIA. THREADED add suffix -316............................................................................................................
REDUCING ATEX approved construction, add suffix -AT ..............................................................
FLANGE SAA approved construction, add suffix -SAA .............................................................
Top Mounted option for vertical flange installation
(distance from flange face to centerline of float to be specified,
2-1/2 X 1-1/2 20˝ (508 mm) maximum), add suffix -TOP ...................................................................
FACE BUSHING Optional Floats (all 2-1/2˝ spherical):
304 SS rated 50 psig (3.5 bar) and 0.5 min. s.g., add suffix -50..................................
*FLANGE FACE TO CENTERLINE OF FLOAT 316 SS rated 150 psig (10.3 bar) and 0.7 min. s.g., add suffix -150............................
SPECIFIED BY CUSTOMER. NORMALLY 304 SS rated 300 psig (20.7 bar) and 0.7 min. s.g., add suffix -300............................
HORIZONTAL, 2-1/2 THREDOLET INSTALLATION SHOULD NOT EXCEED 20˝ [508 mm].
WITH OPTIONAL 2-1/2 [64] SPHERICAL FLOAT Consult factory for price and availability of fittings for L4 installation. Thredolets, bush-
VERTICAL, FLANGE INSTALLATION ings, and flanges are available in a variety of sizes and materials.

224 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg225 7/29/05 8:38 AM Page 1

Series
Liquid Level Switch
®
®

L6
Easy In-wall or External Installation, Up to 2000 psig (138 bar)
SPECIFICATIONS
MODEL L6 WITH EXTERNAL FLOAT CHAMBER Service: Liquids compatible with wetted materials.
1 FEMALE Wetted Materials:
NPT TYP 2 PLACES
3/4 MALE NPT
CONDUIT CONNECTION
Float: Solid polypropylene or 304 SS.
Lower Body: Brass or 303 SS.
3-5/64
[78.18]
Magnet: Ceramic.
Ø1-1/16
External Float Chamber (Tee): Matches lower body choice of
[26.99] brass or 303 SS.
1-9/64
[28.97]
Other: Lever Arm, Spring, Pin, etc.: 301 SS.
2 [50.80]
HEX 8-9/16 Temperature Limit: -4 to 220°F (-20 to 105°C) Standard, MT high
[217.49]
temperature option 400°F (205°C)(MT not UL, CSA or ATEX). ATEX compli-
ant AT option ambient temperature: -4 to 167°F (-20 to 75°C) process tem-
MODEL L6 WITH SPHERICAL FLOAT perature: -4 to 220°F (-20 to 105°C).
Pressure Limits: See chart below.
Enclosure Rating: Weatherproof and Explosion-proof. Listed with UL and
CSA for Class I, Groups A, B, C and D; Class II, Groups E, F, and G.

Level
(Group A on stainless steel body models only).ATEX 0344 II 2 G EEx
d IIC T6 Process Temp≤75°C. EC-Type Certificate No.: KEMA 04ATEX2128
Ø1 [25.40]
1 MALE NPT
3/4 MALE NPT
CONDUIT CONNECTION Switch Type: SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating: UL models: 5A @ 125/250 VAC (V~). CSA and ATEX
models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @ 30 VDC (V ). MV
3/4 Ø1-1/16
option: .1A @ 125 VAC (V~). MT option: 5A @125/250 VAC (V~). [MT option
1-3/4
[44.45]
[19.05] 6
[152.40]
[26.99]
not UL, CSA or ATEX].
Electrical Connections: UL models: 18 AWG, 18˝ (460 mm) long. CSA and
MODEL L6 WITH CYLINDRICAL FLOAT ATEX models: terminal block.
Upper Body: Brass or 303 SS.
Conduit Connection: 3/4˝ male NPT standard, 3/4˝ female NPT on
junction box models.
Process Connection: 1˝ male NPT on models without external float
Ø1 [25.40] x 2 [50.80] chamber, 1˝ female NPT on models with external float chamber.
LONG FLOAT
1 MALE NPT 3/4 MALE NPT
CONDUIT CONNECTION
Mounting Orientation: Horizontal with index arrow pointing down.
Weight: Approximately 1 lb (.5 kg) without external float chamber, 1.75 lb
(.8 kg) with external float chamber.
2-7/8
1-1/16
6-1/2
Ø1-1/16
[26.99]
Specific Gravity: See chart below.
[26.99]
[73.03] [165.10]
Agency Approvals: UL, CSA, CE and ATEX.

MODELS
Max. Pressure Min.
Model No. Body Installation Float Material psig (bar) Sp. Gr.
L6EPB-B-S-3-O Brass Side Wall Mounting Polypropylene Spherical 1000 (69) 0.9
L6EPB-B-S-3-A Brass Side Wall Mounting 304 SS Cylindrical 200 (13.8) 0.5
L6EPB-B-S-3-C Brass Side Wall Mounting 304 SS Spherical 350 (24.1) 0.7
L6EPB-B-S-3-B Brass Brass External Float Chamber (Tee) Polypropylene Spherical 250 (17.2) 0.9
L6EPB-B-S-3-H Brass Brass External Float Chamber (Tee) 304 SS Spherical 250 (17.2) 0.7
L6EPB-S-S-3-O 303 SS Side Wall Mounting Polypropylene Spherical 2000 (138) 0.9
L6EPB-S-S-3-A 303 SS Side Wall Mounting 304 SS Cylindrical 200 (13.8) 0.5
L6EPB-S-S-3-C 303 SS Side Wall Mounting 304 SS Spherical 350 (24.1) 0.7
L6EPB-S-S-3-S 303 SS 304 SS External Float Chamber (Tee) Polypropylene Spherical 2000 (138) 0.9
L6EPB-S-S-3-L 303 SS 304 SS External Float Chamber (Tee) 304 SS Spherical 350 (24.1) 0.7

Surprisingly compact, the Flotect® L6 is designed and built for years Options:
of trouble-free service in a wide variety of process liquid level applica- Gold Plated Contacts option for dry circuits,add suffix -MV
tions. Operation is simple and dependable with no mechanical linkage (see electrical rating in specifications)
as the level switch is magnetically actuated. The float lever pivoted High Temperature option rated 400°F (204°C), add suffix -MT
(see electrical rating in specifications, no listings or
within the body moves when the process liquid displaces the float. A approvals, only available on models with stainless
magnet on the opposite end of the float lever controls a second magnet steel floats)
on the switch actuating lever located in the switch housing. CSA and UL approved construction, includes weatherproof and
explosion-proof junction box,
FEATURES add suffix -CSA
• Leak proof lower body machined from bar stock ATEX approved construction includes, weatherproof and explosion-proof,
junction box
• Choice of models for direct side wall mounting or mounted in a tee
add suffix -AT
to act as an external float chamber DPDT contacts, change seventh character in model
• Weatherproof number to “D”. Example: L6EPB-B-D-3-O
• Explosion-proof (listings included in specifications) 303 Stainless Steel Upper Body, change fifth character in
• Electrical assembly can be easily replaced without removing the model number to “S”. Example: L6EPS-S-S-3-S
unit from the installation so that the process does not have to be
shut down Options Not Shown: 1-1/2˝ and 2˝ male NPT process connection, 2˝ female
• Sensitive to level changes of less than 1/2˝ (12 mm) NPT connection tee, and top mount.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 225
pg226 7/29/05 8:39 AM Page 1

Model
L8 Liquid Level Switch
Low Cost, Leak Proof Body C
Excellent Chemical Resistance

Model L8 Model L8-WP


1/2 FEMALE NPT
CONDUIT CONNECTION

1/2 NPTM 1-5/16 OCTAGON


(33.34)
ø1-21/32
(41.31) 1 NPTM
Level

ø1-1/8
(28.58)

2-17/32
(64.29)
3-1/16 4-5/16
(77.79) (109.54)
10.875
(276.23)

Model L8 Flotect® Liquid Level Switch features a leak SPECIFICATIONS


proof body and float constructed from tough, durable Service: Compatible liquids.
polyphenylene sulfide (equivalent to Ryton®) which has excel- Wetted Materials:
lent chemical resistance. Because the liquid level snap switch is Float and Body: Polyphenylene Sulfide (PPS).
magnetically actuated, there is no direct mechanical linkage to Pin and Spring: 316 SS or Inconel.
leak or fail, assuring longer life and decreased maintenance Magnet: Ceramic 8.
costs. This inexpensive unit is ideal for liquid level alarm, indi- Temperature Limit: 212°F (100°C).
cation or control. Installation is quick and easy — simply install Pressure Limit: 150 psig (10.34 bar).
in a horizontal position with the index arrow pointing down. Enclosure Rating: General purpose. WP option is weatherproof.
Switch Type: SPDT snap switch. MV option is a SPDT gold con-
The L8 Flotect®Liquid Level Control is UL recognized as an in- tact snap switch.
dustrial motor controller per UL standard 508, suitable for Electrical Rating: 5A @ 125/250 VAC, 5A resistive, 3A inductive @
mounting in a protected environment. This lightweight switch 30 VDC. MV option: 1A @ 125 VAC, 1A resistive, 0.5A inductive @
can be used in numerous chemical process, industrial systems 30 VDC.
and similar applications where process conditions are compati- Electrical Connections: 18 AWG, 18˝ (460 mm) long.
ble with polyphenylene sulfide, ceramic 8 and 316 SS. This liq- Conduit Connection: 1/2˝ male NPT.
uid level switch provides accurate setpoint control of liquids Process Connection: 1˝ male NPT.
Mounting Orientation: Horizontal with index arrow pointing down.
with specific gravities as low as 0.6. This compact and reliable Weight: 5 oz (0.142 kg).
control is designed to handle temperatures up to 212°F (100°C) Agency Approvals: CE, UL 508 for US and Canada.
and pressures to 150 psig (10 bar). Specific Gravity: 0.6 minimum.

APPLICATIONS
The Model L8 Flotect® Liquid Level Switch is ideal for prede-
termined liquid levels in tanks through pump control or sole-
noid valve control. It provides excellent liquid level alarm or L8 Level Switch
indication when combined with the Series AN14 Indicating An-
nunciator. OPTIONS:
Gold Plated Contacts, for dry circuits. Rated 1A @ 125 VAC; 1A
resistive, 0.5A inductive @ 30 VDC. To order add suffix
• Environmental control • Chemical/Petroleum processing -MV. Example: L8-MV
• Waste water • Plating and washing tanks Inconel® Option. Inconel® replaces standard 316 SS wetted parts.
• Scrubber systems • Sewage treatment Wetted parts are Inconel®, ceramic 8, and Polyphenylene Sulfide.
• Holding tanks • Car washes To order add suffix -INC.
Example: L8-INC
• Cooling towers • Remediation systems
Weatherproof Enclosure. Optional housing is phenylpolioxide
and provides weatherproof protection for electrical wiring. To order
add suffix -WP. (Not UL approved)
Example: L8-WP

226 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg227 7/29/05 8:40 AM Page 1

Series
L10 Mini-Size Level Switch
Easy In-wall or External Installation, Specific Gravities as Low as 0.5
®

External Float Chamber


Spherical Float
Cylindrical Float 5-7/16
1-3/4 3-1/4
2-3/8 [138.1]

Level
[44.5] 3/4 [82.6] 2-7/8 3-1/2
[19.1] [73.0] 1-1/16 [88.9] [60.3]
[27.0]
1 [25.4]
1[25.4]
2-1/4 [57.2] 2-1/4 [57.15] 3 1[25.4]
1-1/4 [73.0] [76.2] 2-1/4 [57.2]
1 [25.4] 1 MALE NPT 1 MALE NPT
DIA. FLOAT 1/8 NPT – 1/4 [6.4] 1 [25.4] DIA. X 1/8 NPT – 1/4 [6.4]
TRAVEL TO 1/8 NPT 1/4 [6.4]
SWITCH SHOWN TRAVEL TO 2 [50.8] LONG SWITCH 1 1 SWITCH
IN NORMALLY NORMALLY NORMALLY TRAVEL TO
FLOAT SHOWN [25.4] FEMALE SHOWN NORMALLY
OPEN POSITION CLOSED CLOSED
IN NORMALLY POSITION NPT IN NORMALLY CLOSED POSITION
POSITION OPEN POSITION OPEN POSITION

The Mini-Size Series L10 Flotect® Level Switches combine low cost SPECIFICATIONS
with top quality materials and construction for great value and years of re- Service: Compatible liquids.
liable liquid level control. Wide media compatibility is assured with a choice Wetted Materials:
of brass or stainless steel bodies and external tees; polypropylene or stain- Float: Solid Polypropylene or 304 SS.
less steel floats. Two basic configurations are offered; with 1" male NPT Body: Brass or 303 SS.
threads for direct side mounting through a half coupling or with factory in- Magnet: Ceramic.
stalled tee for external mounting.
External Float Chamber (Tee): None, Brass, or 304 SS.
All Series L10 controls feature a hermetically sealed, magnetically actuat- Other: Lever Arm, Pin, Spring, etc.: 301 SS.
ed SPST reed switch which is encapsulated in a polypropylene housing. Temperature Limit: 200°F (93°C).
Units are quickly and easily adjusted for your choice of normally open or Pressure Limit: See chart below.
normally closed operation thanks to a unique patented design. Just loosen Switch Type: SPST hermetically sealed reed switch. Field adjustable
two screws and instantly slide the switch assembly to the action required. for normally open or normally closed.
N.O. and N.C. markings are clearly visible. This feature also speeds switch Electrical Rating: 1.5A @ 24 VDC resistive, 0.001A @ 200 VDC
replacement if damage occurs. resistive, 0.5A @ 125 VAC.
Electrical Connections: 22 AWG, 18˝ (460 mm) long.
Three types of floats are offered to accommodate liquids with specific gravities Conduit Connection: 1/8˝ male NPT.
as low as 0.5; maximum pressures to 2000 psig (137.8 bar). Wire leads are 22 Process Connection: 1˝ male NPT standard on models without
AWG x 18" (460 mm) and exit the switch assembly through 1/8˝ male NPT external float chamber. Change 3 in model number to 4 for 1-1/4˝, to 5
threads. These controls are UL recognized and CSA listed. for 1-1/2˝, or 6 for 2˝. 1˝ female NPT on models with external float
chamber.
Mounting Orientation: Horizontal with index arrow pointing down.
Weight: Approximately 9 oz (0.255 kg) without external float chamber,
2.25 lb (1.02 kg) with external float chamber.
Specific Gravity: See chart below.
Agency Approvals: UL and CSA.
NORMALLY OPEN NORMALLY CLOSED
Switch Enclosure: Polypropylene.

MODELS
Model Body Installation/ Float Max. Press. Min.
Number Material Mounting Material psig (bar) S.G.
L10-B-3-O Brass Side Wall Mounting Polypropylene Spherical 1000 (69) 0.9
L10-B-3-A Brass Side Wall Mounting 304 SS Cylindrical 200 (13.8) 0.5
L10-B-3-C Brass Side Wall Mounting 304 SS Spherical 350 (24.1) 0.7
L10-B-3-B Brass Brass External Float Chamber (Tee) Polypropylene Spherical 250 (17.2) 0.9
L10-B-3-H Brass Brass External Float Chamber (Tee) 304 SS Spherical 250 (17.2) 0.7
L10-S-3-O 303 SS Side Wall Mounting Polypropylene Spherical 2000 (137.8) 0.9
L10-S-3-A 303 SS Side Wall Mounting 304 SS Cylindrical 200 (13.8) 0.5
L10-S-3-C 303 SS Side Wall Mounting 304 SS Spherical 350 (24.1) 0.7
L10-S-3-S 303 SS 304 SS External Float Chamber (Tee) Polypropylene Spherical 2000 (137.8) 0.9
L10-S-3-L 303 SS 304 SS External Float Chamber (Tee) 304 SS Spherical 350 (24.1) 0.7

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 227
pg228 7/29/05 8:41 AM Page 1

Series
CFS Cable Float Switch
No Hazardous Mercury, Adjustable Counterweight, General Purpose

Ø 1 5/8 Ø 5 5/32
[41.40] [131.06]

Ø 3 3/16
[81.03]

Control the level of liquids in filling or draining reservoirs and tanks SPECIFICATIONS
Level

with the Series CFS. The mercury-free switch is designed with an Service: Compatible liquids.
inverter microswitch housed in a polypropylene cover. The unit Wetted Materials: Polypropylene housing, PVC cable.
includes a counterweight to adjust the stop and start levels of pump Temperature Limits: 140°F (60°C).
up/pump down application. Pressure Limits: 60 psi (4 bar).
Enclosure Rating: NEMA 4 (IP68).
MODELS Switch Type: SPDT.
Model Electrical Rating: 10 A @ 250 VAC, resistive.
Cable Length
Number Mounting Orientation: Vertical.
CFS-2 6.5 ft (2 m) Weight: CFS-2: 1.416 lb (.62 kg).
CFS-10 CFS-10: 3.316 lb (1.48 kg).
32.8 ft (10 m)
Agency Approvals: CE.

Series
FSW Free-Floating Level Switch
Designed for Industrial Applications, Mercury-Free

6 13/32
[162.99]
Ø 4 3/64
[102.87]

Series FSW Free-Floating Level Switch is a dual level SPECIFICATIONS


switch designed for filling and draining of tanks, wells, and Service: Compatible liquids, slurries.
reservoirs. The shape and interior balance weight ensure impu- Wetted Materials: Polypropylene housing, EPDM gland, PVC
rities and dirt will not adhere to the surface, making it ideal for cable.
sewage and waste water applications. The mercury-free switch Temperature Limits: 140°F (60°C).
is designed with an inverter microswitch housed in a polypropy- Pressure Limits: 60 psi (4 bar).
lene cover. Enclosure Rating: NEMA 4 (IP68).
Switch Type: SPDT.
MODELS Electrical Rating: 10 A @ 250 VAC, resistive.
Model Mounting Orientation: Vertical.
Cable Length
Number Weight: FSW-6: 2.6 lb (1.2 kg); FSW-15: 3.85 lb (1.75 kg);
FSW-6 19.5 ft (6 m) FSW-30: 6.8 lb (3.1 kg).
FSW-15 49 ft (15 m) Agency Approvals: CE.
FSW-30 98 ft (30 m)

228 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg229 7/29/05 8:41 AM Page 1

Model
F7-MLK Multi-Level Switch Kit
One or Two Station Level Switch, Vertically Mount
.500 1/2" NPT
[12.7]
9.220
[234]
Ø1.250 4.000
[31.8] [102] 2 SWITCHES

2⬙ NPT PIPE .500


7.991 MOUNTING [12.7]
[201]
12.000
[305] 1 FITTING
10.905 ASSEMBLY .500
[277] 2 BUNA-N [12.7]
1.916 FLOATS
[48.7] .875
[22.2]
.500 .875 4 TUBE
[12.7] [22.2] 1.965 UNIONS
1 TUBE END [49.9]
2.500 FITTING
2 EXTENSION [63.5]
TUBES 1.128
.875 [28.7]
[22.2]

Customize a level systemto suit your application requirements. The SPECIFICATIONS

Level
Service: Compatible liquids.
F7-MLK Multi-Level Switch Kit contains all the components necessary
Wetted Materials (Float/Stem): Buna-N/Brass.
for the design and fabrication of a 1 or 2 station level switch for pipe plug Temperature Limits: 221°F (105°C).
mounting. User can customize stem length (maximum 36˝), actuation Pressure Limits: 150 psig (10 bar).
point, distance between floats, and lead wire lengths. The switch kit is Switch Type: SPST, normally open or normally closed.
Electrical Rating: 60 Watts: 0.4A @ 220 VAC, 0.5A @ 110 VAC,
ideal for general purpose, low specific gravity, and gas and oil applications. 0.2A @ 120 VDC, 0.5A @ 24 VDC.
Model F7-MLK includes two level stations (switch, tube, and Buna-N float), Electrical Connections: 22 AWG x 72˝ (183 cm) leads.
two brass extension tubes 12˝ length, four brass tube unions, one end fit- Process Connection: 2˝ male NPT pipe plug.
ting, and one mounting plug. Mounting Orientation: Up to 30° angle from vertical.
Stem Length: 36˝ (91 cm) maximum.
Tube/Fitting Size: 1/2˝ O.D.
Model F7-MLK Multi-Level Switch Kit Minimum Specific Gravity: 0.45.
Weight: 3.5 lb (1.6 kg).

Model
F7-MLK2 Multi-Level Switch Kit
316 Stainless Steel, One or Two Station Level Switch, Vertically Mount
1.25 SQ
(1-1/4)
1.5 .500
(1-1/2) 2 NPT [12.7] 1/2" NPT
3/8 NPT FEMALE
1.75 TUBE CONNECTOR 1.500 4.125
(1-3/4) FLOAT TUBE AND [38.1] [108] 2 SWITCHES
SWITCH STATION
2⬙ NPT PIPE .500
Ø2.063 [12.7]
MOUNTING
2.125 (2-1/16) 10.000
(2-1/8) [254] 1.750
TUBE UNION
[44.5] Ø2.062
[52.4]
2.125 TUBE UNION 1 TUBE
CONNECTOR/
(2-1/8) 2.125 3 TUBE
FLOAT TUBE AND [54] UNIONS
1 TUBE END
2 SS 1.188
Ø2.063 SWITCH STATION FLOATS [30.1]
FITTING
(2-1/16) 2 EXTENSION
1.186 TUBES
(1-3/16)
TUBE END
FITTINGS

The F7-MLK2 Multi-Level Switch Kit contains all the com- SPECIFICATIONS
ponents necessary for the design and fabrication of a 1 or 2 sta- Service: Compatible liquids.
tion level switch for pipe plug mounting. The user can customize Wetted Materials (Float/Stem): 316 SS.
Temperature Limits: -40 to 275°F (-40 to 135°C).
stem length (maximum 36˝), actuation point, distance between
Pressure Limits: 750 psi (52 bar).
floats, and lead wire lengths. Model F7-MLK2 is constructed of Switch Type: SPST, selectable N.O. or N.C.
316 SS—ideal for chemicals, corrosive liquids, oils, or high pres- Electrical Rating: 20 VA: 0.8A @ 240 VAC, 0.17A @ 120 VAC, 0.3A @
sure applications. Model F7-MLK2 includes two level stations 30 VDC.
with floats (switch, tube, and float), two extension tubes 10˝ (254 Electrical Connections: 18 AWG x 60˝ (152 cm) wire leads.
mm) length, three tube unions, one tube connector, one end fit- Process Connections: 2˝ male NPT pipe plug.
Mounting Orientation: Up to 30° angle from vertical.
ting, and one mounting plug.
Minimum Specific Gravity: 0.75.
Tube Diameter: 1/2˝ O.D.
Stem Length: 36˝ (91 cm) maximum.
Weight: 3.3 lb (1.6 kg).
Model F7-MLK2 Multi-Level Switch Kit
CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 229
pg230 7/29/05 8:42 AM Page 1

Series
F7 Level Switches - Vertical
Low Cost, Reliable and Compact, Hermetically Sealed Contacts

D 1/8" NPT(M)
A
F7-SB F7-ST713 C

Series F7 compact level switches combine low cost and re- DIMENSIONS in Inches [mm]
liability with fast, simple installation. Hermetically sealed reed Model (A) Stem (B) Float (C) Float (D) Actuation
switches are actuated by magnets permanently bonded inside Number Length Diameter Height from Hex①
Level

F7-SB 2.75 [70] 1.38 [35] 1.13 [29] 1.2 [31]


the float and can be easily adapted to open or close a circuit on
F7-SS2 2.06 [52] 1.0 [25] 1.0 [25] 0.73 [19]
rising or falling levels. Vertical mount models are shipped with F7-MPP 1.63 [41] 0.63 [16] 0.63 [16] 0.47 [12]
normally open switch contacts which close as the float rises to- F7-PP 2.18 [55] 1.18 [30] 1.0 [25] 0.69 [18]
ward the mounting threads. Reverse switch action by removing F7-BT 2.18 [55] 1.18 [30] 1.0 [25] 0.69 [18]
the float, rotating it end-for-end and replacing it on the stem. Ver- F7-K 2.13 [54] 1.0 [25] 1.0 [25] 0.65 [17]
F7-C11 2.06 [52] 1.0 [25] 1.0 [25] 0.56 [14]
tical models mount internally, oriented within 30° of vertical, or
F7-C21 2.06 [24] 1.0 [25] 1.0 [25] 0.56 [14]]
select optional fittings for external mounting. Switch ratings are F7-BB 3.19 [81] 1.88 [48] 1.81 [46] 1.19 [30]
suitable for many solid state control systems and monitors or F7-PS 3.38 [86] 1.88 [48] 1.88 [48] 1.25 [32]
alarms. Simple relay interfaces can be used for higher current F7-PVC 3.44 [87] 1.5 [38] 1.81 [46] 0.75 [19]
applications. F7-T1 3.47 [88] 2.13 [54] 1.94 [49] 0.92 [22]
F7-ST713 3.38 [86] 2.06 [52] 2.06 [52] 1.09 [28]
MODELS F7-ST714 3.38 [86] 2.06 [52] 2.06 52] 1.09 [28]

Model Applications Material Temp. Press. Min. Electrical Wire Mtg Weight
Number Float/Stem Limits Limits S.G. Rating Leads NPT(M) oz (g)
Buna-N & Epoxy/ 220˚F 150 psig 25 VA: 1A @ 220VAC 22 AWG 18˝ 1/8˝ 2 (58)
F7-SB General purpose 0.60
316 SS 105˚C 10 bar [45 cm]
High temp/pressure, 316SS (CYC)/ 300˚F 450 psig 25 VA: 1A @ 200VAC 22 AWG, 18˝ 1/8˝ 1.2 (34))
F7-SS2 0.75
corrosives 316 SS 149˚C 31 bar [45 cm]
Broad chemical Polypropylene/ 180˚F 100 psig 10 VA: 0.1A @ 100VAC 22 AWG, 24˝ 1/8˝ 0.8 (23)
F7-MPP** 0.90
compatibility Polypropylene 82˚C 6.89 bar [61 cm]
Broad chemical Polypropylene/ 176˚F 100 psig 50 VA: 0.2A @ 240VAC 22 AWG, 24˝ 1/8˝ 0.8 (23)
F7-MPP-NO** 0.90
compatibility Polypropylene 80˚C 6.89 bar [61 cm]
Broad chemical Polypropylene & 220˚F 100 psig 30 VA: 0.14A @ 220VAC 22 AWG, 24˝ 1/8˝ 0.8 (23)
F7-PP 0.60
compatibility Epoxy/Polypropylene 105˚C 6.89 bar [61 cm]
Buna-N & Epoxy/ 220˚F 150 psig 30 VA: 0.14A @ 220VAC 22 AWG, 24˝ 1/8˝ 0.7 (20)
F7-BT Oils & Fuels 0.45
PBT* 105˚C 10 bar [61 cm]
Food/beverage, Kynar®/ 180˚F 100 psig 50 VA: 0.25A @ 150VAC 22 AWG, 24˝ 1/8˝ 1.5 (43)
F7-K 1.00
corrosives Kynar® 82˚C 6.89 bar [61 cm]
General Buna-N/ 180˚F 150 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/8˝ 1.5 (43)
F7-C11 0.45
purpose Brass 82˚C 10 bar [61 cm]
Oils & water, Buna-N/ 180˚F 150 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/8˝ 1.5 (43)
F7-C21 0.45
general purpose 316 SS 82˚C 10 bar [61 cm]
High viscosity Buna-N/ 180˚F 150 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/4˝ 5 (140)
F7-BB 0.55
liquids Brass 82˚C 10 bar [61 cm]
Water-based liquids, Polysulfone/ 225˚F 50 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/4˝ 4 (110)
F7-PS 0.55
complies with FDA Polysulfone† 107˚C 3 bar [61 cm]
Chemical & CPVC/ 180˚F 15 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/4˝ 5 (140)
F7-PVC 0.85
plating CPVC 82˚C 1 bar [61 cm]
Viscous, sticky or Teflon®/ 300˚F 30 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/4˝ 6 (170)
F7-T1 0.80
corrosive liquids Teflon® 149˚C 2 bar [61 cm]
Oils, water & 316 SS/ 300˚F 750 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/4˝ 6 (170)
F7-ST713‡ 0.80
chemicals 316 SS 149˚C 52 bar [61 cm]
① Distance between hex and liquid (S.G. = 1.0) level at actuation point will vary with spe- Optional Fittings — For external mounting of vertical models
cific gravity changes.
A-347, 1⁄8" x 11⁄4" NPT carbon steel adapter
*PBT - Polybutylene Terephthalate.
A-347-SS, 1⁄8" x 11⁄4" NPT 316 SS adapter
† Incudes 316 SS clip.
A-348, 1⁄8" x 11⁄2" NPT carbon steel adapter
‡ Spherical floats.
Note: F7-SB, F7-SS2 not CSA listed. A-348-SS, 1⁄8" x 11⁄2" NPT 316 SS adapter
**F7-MPP is normally closed
F7-MPP-NO is normally open

230 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg231 7/29/05 10:06 AM Page 1

Series
F7
Level Switches - Horizontal/Specialty
Low Cost, Hermetically Sealed Contacts

F7-HSS
F7-HPS-11

F7-HPS-21 F7-SS5BNC

F7-LL
F7-WBB
F7-EB JUNCTION BOX
F7-MHS
3.750 F7-EBX ONLY
3.8 4.25 [95.3]
[97] [108] 2.875
[73] 1/2 NPT FEMALE
0.63"
0.7 DIA. [16] .69 1.375 1.00
[18] [18] [34.9] [25.4]
1.00 1-3/4
[25.4]

Level
2-3/4 [44.5]
[70]
1/2" NPT
.1875 [4.76] 7
2.6 2.9" 1/2-13 [178] 4-1/4
[65] [73] THREAD
0.3 [108]
[8] F7-MHS
F7-HPS-11 F7-HPS-21

Ø2-5/8 2-1/8
1/2-13 BULKHEAD [67] [54]
F7-EB
13/16 MIN
FITTING (20.6) 1/8 NPT
CENTERLINE 22 AWG
LEAD WIRES
3/32 1-7/32 MAX
(2.54) (31.0)
3.250 3.500 2-3/32 1/2
[12.7] HEX 3-1/2
[82.55] [88.9] [53] [89]
1-5/32 MAX
APPROXIMATE
(29.2) 1-15/32
ACTUATION [37]15/16 1/4
LEVEL 4-5/8 MAX
(116.8) [24] [6.4]
1/2-14 NPT
1-5/16
[33]
Ø1.50 Ø 5/16
5.770 [38.1] [8]
F7-HSS Ø 1-7/8
[47]
[146.558] Ø1-7/16
[37]
F7-SS5BNC
F7-LL F7-WBB

Series F7 Horizontal Mount Level Switches are designed to Series F7 Specialty Level Switches are designed for unique ap-
mount through the walls of tanks and other vessels. Internally mount- plications. Model F7-SS5B/BNC can be used with viscous liquids or liq-
ed models F7-HPS-1, F7-MHS and F7-SS5 are secured to the wall of the uids with suspended metal particles. Use model F7-LL for low level
tank or vessel from the inside while model F7-HPS-2 is mounted from detection (>5/8˝). The non-intrusive bottle style F7-EB mounts com-
the outside (externally). Model F7-HSS can be installed internally or ex- pletely outside the tank at the actuation level. Suspend model F7-WBB
ternally. in stand pipes or sumps for leak detection or drop into wells for ground-
water monitoring.
MODELS - Horizontal Mount Switches
Model Applications Material Temp. Press. Min. Electrical Wire Mtg Weight
Number Float/Stem Limits Limits S.G. Rating Leads oz (g)
Water, oils, chemicals Polypropylene/ 225˚F 100 psig 20 VA: 0.08A @ 240VAC 22 AWG 24˝ 5/8˝-11 1.5 (43)
F7-HPS-11 0.55
NSF approved Polypropylene* 107˚C 6.89 bar [61 cm] thread (int)
Water, oils, chemicals Polypropylene/ 225˚F 100 psig 20 VA: 0.08A @ 240VAC 22 AWG, 24˝ 1/2˝ NPT 2 (58)
F7-HPS-21 0.55
NSF approved Polypropylene* 107˚C 6.89 bar [61 cm] (ext)
High temperatures, 316 SS/ 392˚F 100 psig 30 VA: 0.14A @ 220VAC 22 AWG, 24˝ 1/2˝-13 bulk- 2 (58)
F7-MHS 0.70
corrosives 316 SS 200˚C 6.89 bar [61 cm] head (int)
High temp/pressure, 316 SS 392˚F 300 psig 30 VA: 0.14A @ 220VAC 22 AWG, 24˝ 1/2˝ NPT 3 (94)
F7-HSS† 0.60
corrosives, Expl. 316 SS 200˚C 20.7 bar [61 cm] (int/ext)

MODELS - Specialty Switches


Model Style/ Material Temp. Press. Min. Electrical Wire Mtg Weight
Number Applications Float/Stem Limits Limits S.G. Rating Leads oz (g)
Bent stem/liquids 316 SS/ 300˚F 100 psig 20 VA: 0.08A @ 220VAC 22 AWG, 24˝ 1/8˝ NPT 2 (58)
F7-SS6 0.70
with metal particles 316 SS 149˚C 7 bar N.O. operation [61 cm] male
Bent stem/liquids 316 SS/ 300˚F 100 psig 20 VA: 0.08A @ 220VAC 22 AWG, 24˝ 3/8˝-24” 2 (58)
F7-SS6B 0.70
with metal particles 316 SS 149˚C 7 bar N.C. operation [61 cm] male
Non-intrusive bottle type/ Brass/316 SS 300˚F 500 psig 20 VA: 0.08A @ 240VAC 18 AWG, 24˝ 3/4˝ NPT 5 lb 5 oz
F7-EB‡ 0.75
outside tank mounting (Brass housing) 149˚C 34 bar [61 cm] female (2.4 kg)
Vertical/detect levels as Polysulfone/ 180˚F 50 psig 20 VA: 0.08A @ 240VAC 22 AWG, 72˝ 1/8˝ NPT 2 (58)
F7-LL —
low as 5/8” Buna-N 82˚C 3 bar [182 cm] male
25 ft. cable, slosh shield/ Brass/ 180˚F 150 psig 20 VA: 0.08A @ 240VAC 22 AWG, 25 ft. — 10.8 (310)
F7-WBB 0.45
sumps, stand pipes Buna-N 82˚C 10 bar [7.6 m]
* Contains 20% glass. ‡ Explosion proof model available with DPDT switch. Specify F7-EBX.
† F7-HSS is rated explosion-proof for Class I, Groups A, B, C, D; Class II,
Groups E, F, G; Class III.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 231
pg232 7/29/05 10:00 AM Page 1

Series
F7-MM Miniature Multi-Station Level Switch
Custom, Lightweight, Low Cost, 316 SS or Buna-N Floats
MOUNTING DIMENSIONS

L5 A 1-1/16 Hex 1-5/16 Hex


1/8 NPT
[.125] [26.97] [33.32]
L4
1/2 HEX 3/4 NPT 1 NPT
[12.7]
Type 1 Type 2 Type 3

L3 B 6 HOLES 0 5/16 [7.95]


0 3-5/8 EQUALLY SPACED
LO ON A 3.000 B.C.
[92.08]
1-1/2 HEX
L2 [76.20]
[38.10] 3/8-24
1-5/16-12 THREAD THREAD
1/8 NPT
L1
3/16
[4.78] Type 4 Type 5 Type 6
D
Level

FLOAT DIMENSIONS

FLOAT A B D 15/16 1-1/4 1


TYPE in. in. in. [23.80] [31.75] [25.40]
F1 7/8 1-3/4 3/4 0 29/32 0 1-1/2
F2 3/4 1-7/8 1-1/16 01.000 [22.86]
F3 3/4 1-13/16 15/16
[38.10]
F1 [25.40] F2 F3
F4 13/16 2-7/16 1-7/16
F5 9/16 2-7/16 1-3/4
F6 15/16 1-7/8 7/8, NO
1-3/16, NC 1-3/32 1-7/32 1-1/8
F7 13/16 2 1-1/8 1-19/32
Ø 29/32 [27.79] 1-1/32 [30.99] [28.58]
F8 3/4 1-7/8 1-1/16 Ø 29/32 [40.49] 1-9/64
Actuation Levels [22.86] [26.16]
Each switching point requires one float. [22.61] [29.79]
A = Minimum distance from actuation point to bottom of mounting. F4, F5 F6 F7 F8
B = Minimum distance between actuation levels.
D = Minimum distance from end of unit to lowest actuation point.
Miniature custom level switches with a sturdy. lightweight design SPECIFICATIONS
are ideal for tanks less than four feet (1.2 m) deep. Control up to five dif- Service: Compatible liquids.
ferent level points across a maximum length of 48˝ (121 cm). Stems and Wetted Materials: Stem, connection, and float.
mounting fixtures are available in 316 SS or brass. Temperature Limits: F1 and F2: Water, 180°F (82.2°C); Oil, -40 to
250°F (-40 to 121.1°C). All other floats: -40 to 300°F (-40 to 148.9°C).
Electrical Connection: 24˝ (61 cm) free leads #22 AWG, Teflon® jacketed.
Models are built to your specifications Mounting Orientation: Vertical ±30°.

Example F7-MM B 1 5 F1 1 F7-MMB1-5F51-03.00-07.00-11.00-15.00-20.00-25.00


Construction F7-MM Multi-station level, 1 to 5 switch points
Stem & Connection B Brass with Beryllium copper stops
Material S 316SS with SS ARMCO PH-15-7MO stops
1 1/8˝ NPT
Connection 2 3/4˝ NPT (Cannot be used with float F1, F3, F7 and F8)
Type 3 1˝ NPT (Cannot be used with float F3)
4 3-5/8˝ Flange [Maximum pressure is 50 psi (3.45 bar)]
5 1-5/16-12UNF-2A (Cannot be used with float F3)
6 3/8-24
Switch Points # Put 1 to 5 for the number of switch points desired
Material Min. s.g. Max. Pres. psi (bar)
F1 Buna-N .45 300 (20.68)
F2 Buna-N .60 250 (17.24)
F3 316SS .70 100 (6.89)
Float Type
F4 316SS .85 150 (10.34)
F5 316SS 1.1 400 (27.58)
F6 Teflon® .65 1000 (68.95)
F7 316SS .85 275 (18.96)
F8 316SS .90 600 (41.37)
1 SPST, .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240 VDC
Switch 2 SPST, .8A @ 120 VAC, .4A @ 240 VAC (not UL)
Type
NO switch is standard. For NC place an “*” after the corresponding set point distance in
the model number
L5 00.00 In inches referenced from bottom of connection
L4 00.00
Set Point L3 00.00 Repeat for each switch point with dashes in between.
Distance L2 00.00 No numbers needed beyond the number of switches specified. In inches for example
L1 00.00 12.25 would be 12.25˝ from the bottom of the process connection.
Overall Length L0 00.00 Maximum overall length of 48 inches (121 cm). Minimum length is L1 + D.
Options

232 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg233 8/11/05 11:29 AM Page 1

Series
F7-MQ Quick-Ship Multi-Station Level Switch
Fast Delivery, Customized, Up to Four Actuation Levels

FLOAT DIMENSIONS

L4 A
L3 1-13/16 2-3/32
1-3/4
[46.02] [53.16]
[44.45]
Ø 1-1/4 Ø 1-7/8 Ø 2-1/16
LO [31.75] BUNA-N [47.62] 316 SST [52.37]
B OPTION 2 OPTION 3
L2
F1 F2 F3

L1

Level
MOUNTING DIMENSIONS

1/2 NPT 1/2 NPT


1/2 NPT 1.000 SQ 1-1/4 SQ
A B D
[25.40] [31.75]
1-1/2˝ 3˝ 2˝ 1-1/4 NPT 2 NPT
(38.10 mm) (76.20 mm) (50.80 mm)
Actuation Levels MOUNTING OPTION 2 MOUNTING OPTION 3
Each switching point requires one float.
A = Minimum distance from actuation point to bottom of mounting. Type 1 Type 2 Type 3
B = Minimum distance between actuation levels.
D = Minimum distance from end of unit to lowest actuation point.

Customize level switches to meet application requirements SPECIFICATIONS


quickly and affordably. Switches can be configured with up to Service: Compatible liquids.
four different control points and stem lengths up to 72˝ (1.82 m). Temperature Limits: F1 and F2 with water: 0 to 180°F (-18 to
Stems and floats are available in 316 SS or brass. 82°C); Buna-N floats with oil: -40 to 230°F (-40 to 110°C); F3: -40
to 300°F (-40 to 149°C).
Electrical Connections: 24˝ (61 cm) free leads; #22 AWG
Teflon® and #18 AWG Polymeric.
Mounting Orientation: Vertical ±30°.
Models are built to your specifications

Example F7-MQ B 1 4 F3 3 J F7-MQB1-4F33-07.00-11.00-15.00-20.00-24.00-J


Construction F7-MQ Multi-station level, 1 to 4 switch points
Stem & Connection B Brass with Beryllium copper stops
Material S 316SS with SS ARMCO PH-15-7MO stops
1 1/2˝ NPT (Float F2, F3 only)
Connection 2 1-1/4˝ NPT (Float F1 only)
Type 3 2˝ NPT(Float F2, F3 only)

Switch Points # Put 1 to 4 for the number of switch points desired


F1 Buna-N, min. s.g. 0.75, 150 psi (10.3 bar) max. pres.
Float Type F2 Buna-N, min. s.g. 0.55, 150 psi (10.3 bar) max. pres.
F3 316SS, min. s.g. 0.75, 750 psi (51.7 bar) max. pres.
Switch 1 SPST, .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240 VDC
Type 3 SPDT, .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240 VDC
NO switch is standard. For NC place an “*” after the corresponding set point distance in
the model number.
In inches referenced from bottom of connection
L4 00.00
Set Point
L3 00.00 Repeat for each switch point with dashes in between.
Distance
L2 00.00 No numbers needed beyond the number of switches specified. In inches for example
L1 00.00 12.25 would be 12.25˝ from the bottom of the process connection.

Overall L0 00.00 Minimum length is L1+D. Maximum length with Connection Length is 72˝ (1.82 m)
Length
Options J Junction box for wire leads, NEMA 4 (Not available with Connection Type 1)

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 233
pg234 7/29/05 9:59 AM Page 1

Series
F7-MS Multi-Station Level Switch
Customize To Fit Application, Up to Six 316 SS or Buna-N Floats
FLOAT DIMENSIONS

L6 A
1-3/4 1-13/16 2-3/32
L5 [44.45] [46.02] [53.16]
Ø 1-1/4 Ø 1-7/8 Ø 2-1/16
[31.75] [47.62] [52.37]
L4 B F1 F2 F3
LO
MOUNTING DIMENSIONS
L3 6 HOLES Ø 3/4 [19.05]
EQUALLY SPACED
ON A 6.000 B.C.
L2 [152.4]
1/2 NPT

L1
Level

D
Type 1 1/2 NPT
1-1/4 SQ Ø7-1/2
[31.75] [190.5]
2 NPT
A B D
1/2 NPT Type 3 1/2 NPT
1-1/2˝ 3˝ 2˝ 1
1.000 SQ
(38.10 mm) (76.20 mm) (50.80 mm) [25.40]
[25.40]
Actuation Levels 1-1/4 NPT
Each switching point requires one float.
A = Minimum distance from actuation point to bottom of mounting.
B = Minimum distance between actuation levels. Type 2
Type 4, 5
D = Minimum distance from end of unit to lowest actuation point.

Customize level switches to meet application requirements SPECIFICATIONS


Switches can be configured with up to six different control Service: Compatible liquids.
points and stem lengths up to 140 inches (3.56 m). Stems and Wetted Materials: Stem, connection, and float.
floats are available in 316 SS or brass. Temperature Limits: Buna-N floats: 180°F (82.2°C) in water, -40
to 230°F (-40 to 110°C) in oil; SS floats: -40 to 300°F (-40 to
148.9°C).
Wire Leads: 24˝ (61 cm) free leads; #22 AWG Teflon® and #18
Models are built to your specifications AWG Polymeric.
Mounting Orientation: Vertical ±30°.

Example F7-MS B 1 5 F3 1 J F7-MSB1-5F31-04.00-07.00-11.00-15.00-20.00-24.00-J


Construction F7-MS Multi-station level, 1 to 6 switch points
Stem & Connection B Brass with Beryllium copper stops
Material S 316SS with SS ARMCO PH-15-7MO stops
1 1/2˝ NPT (Float F2, F3 only)
2 1-1/4˝ NPT (Float F1 only)
3 2˝ NPT
Connection
4 3˝ 150# Flange Carbon Steel (Conn. material S only, float F2, F3 only) [Max. pres. 150 psi
Type
(10.3 bar)]
5 3˝ 150# Flange 316SS (Conn. material S only, float F2, F3 only) [Max. pres.
150 psi (10.3 bar)]
Switch Points # Put 1 to 6 for the number of switch points desired
F1 Buna-N, min. s.g. 0.75, 150 psi (10.3 bar) max. pres.
Float Type F2 Buna-N, min. s.g. 0.55, 150 psi (10.3 bar) max. pres.
F3 316SS, min. s.g. 0.75, 750 psi (51.7 bar) max. pres.
1 SPST, .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240 VDC
2 SPST, .8A @ 120 VAC, .4A @ 240 VAC (Not UL)
Switch 3 SPDT, .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240 VDC
Type No switch is standard. For NC place an “*” after the corresponding set point distance
in the model number.
L6 00.00 In inches referenced from bottom of connection.
L5 00.00
Set Point L4 00.00 Repeat for each switch point with dashes in between.
Distance L3 00.00 No numbers needed beyond the number of switches specified. In inches for example
L2 00.00 12.25 would be 12.25˝ from the bottom of the process connection.
L1 00.00
Overall Minimum length is L1+D. Maximum length with Connection Type 1: 36˝ (91.4 cm),
00.00
Length Type 2: 60˝ (152.4 cm), and Types 3, 4, 5: 140˝ (355.6 cm).
J Junction box for wire leads, NEMA 4 (Not available with Connection Type 1)
Options

234 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg235 7/29/05 9:58 AM Page 1

Model
OLS Optical Level Switch
Low Cost, Compact, LED Indication

1-3/4
[44.50]
7/8
HEX

OLS-10 OLS-11 HIGH

LOW
RED, +
BLK, GND
WHT, CONTROL

82-700405-00

Level
1/8 1/4
[3.200] [6.400]

OLS-12

Low cost, rugged optical level switch provides rapid response SPECIFICATIONS
while employing no moving parts for stable process control. The Service: Noncoating compatible liquids.
bright red and green LED’s indicate the presence or absence of liq- Wetted Materials: See model chart.
uid for true, local indication. Three optional materials, 316 SS, polysul- Temperature Limit: Process: 200°F (93.3°C), Ambient: 175°F
fone and Teflon® provide application flexibility. Compact switch can be
(79.4°C).
quickly mounted horizontally or vertically for each installation.
Pressure Limit: 200 psig (13.8 bar).
Repeatability: ±0.02˝ (0.5 mm).
PRINCIPLES OF OPERATION Switch Type: NPN open collector.
The optical level switch employs an LED, which transmits infrared Power Requirements: 10 to 28 VDC.
light. This light is sent through a prism and reflected back to a photo- Output Signal: Vout (max) = 28 VDC, Isink (max) = 100 mA.
transistor utilizing two 90° light reflections. With the prism surround-
Current Consumption: 35 mA maximum.
ed by a gas, the light source is cast back to the photo transistor. When
Electrical Connections: 22 AWG, 18˝ (460 mm) long.
a translucent liquid is introduced to the prism at or above the point
where the light source makes contract with the prism, the light is Process Connection: 1/2˝ male NPT.
reflected into the liquid, not allowing the photo-transistor to energize. Mounting Orientation: Can be mounted in any position.
Weight: 2.5 oz (0.07 kg).
Specific Gravity: No minimum.

FEATURES
Suggested Specifications
•Compact Size
•LED Switch Indication Optical level switch shall be Teflon®, 316 SS and Polysulfone or
•No Moving Parts Polysulfone construction. Unit shall provide an NPN open collector out-
put signal. Switch shall be capable of mounting in horizontal or vertical
position. Switch shall incorporate LED switch status.
MODELS
Model No. Wetted Materials APPLICATIONS
Model OLS-10 316 SS/Polysulfone • Food and beverage systems • Liquid holding tanks
Model OLS-11 Polysulfone • Hydraulic reservoirs • Sumps
• Pharmaceutical systems • Air conditioning systems
Model OLS-12 Teflon®

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 235
pg236 7/29/05 9:58 AM Page 1

Series
123 Cast Iron Chamber – Water Level Control
Heavy Duty, Snap Action Type ®

1 NPT

1-1/8
[28.58] 3-9/16
[90.50]
Ø5-3/4
[146.05] 7-1/8
[180.98]
2-7/16
[61.91]

1/2 PIPE PLUG


5-1/2 TYP 2 PLACES 3-9/16
[139.70] [90.50]
7 5-3/8 4-3/4
[177.80] [136.53] [120.65]

Designed for boiler applications, the model 123 is primarily used SPECIFICATIONS Electrical Rating: Snap Switch:
for low water cut-off or feed-water control. Other applications include Service: Compatible liquids. Cast 15A @ 120/240/480 VAC, 0.5A @
iron is not for use with lethal or flam- 120 VDC resistive, 0.25A @ 240
condensate tanks and deaerators. A special positive snap action switch
Level

mable substances either liquid or VDC resistive. Mercury Switch: 4A


mechanism eliminates frequent operation due to surging water level. gaseous. @ 120 VAC/DC, 2A @ 240 VAC/DC.
A transparent cover provides convenient visible operation of the Wetted Materials: Body: Cast iron. Electrical Connections: Screw
switch. Features a flanged chamber for easy clean out and replace- Float and Trim: 304 SS. Packing terminal.
ment of float or switch mechanism without removing the unit from pip- Gland: Brass.Packing: Carbon. Conduit Connection: 7/8˝ (22.23
ing. Body Gasket: Carbon. mm) hole for 1/2˝ (12.7 mm) conduit.
Temperature Limit: 365°F (185°C). Process Connections: 1˝ female
Pressure Limit: 150 psig NPT.
(10.34 bar). Mounting Orientation: Vertical.
MODELS Enclosure Rating: General Weight: 20 lb (9.1 kg).
Purpose. Optional weatherproof. Agency Approvals: UL and CSA.
Model Number Switch Type Switch Type: SPDT snap switch or (Snap switch is not rated).
mercury switch. Optional DPDT or Deadband: Approximately 1-1/2˝
123-153 SPDT Mercury (38.1 mm).
two stage.
123-7000-153 SPDT Snap Specific Gravity: 0.88 minimum.
Options: Manual Reset.

Series
102 Flanged Chamber Type Level Control ®

Operating Pressures to 300 PSIG


SPECIFICATIONS
Service: Compatible liquids. Cast iron is not for use with
6-3/4 Ø5-3/4
[171.45] [146.05] lethal or flammable substances either liquid or gaseous.
Wetted Materials:
Body: Cast iron. Optional cast steel or 316 SS.
Float and Trim: 303 SS, 304 SS, 316 SS, and 430 SS.
1 NPT 3/4 NPT CONDUIT Option of all 316 SS.
CONNECTION. CAN Body Gasket: Carbon.
17-1/2 BE ROTATED 360˚. Temperature Limit: 425°F (218°C).
[444.5]
Pressure Limit: 300 psig (20.7 bar). Optional rating to
8-1/4 B 400 psig (27.6 bar).
[209.55] Enclosure Rating: NEMA 4X. Optional general pur-
SP.
GR. A B pose or explosion-proof.
A Repeatability: ±1/4˝ (6.4 mm).
1.0 51⁄16 3
⁄4
[129 mm] [19 mm] Switch Type: SPDT snap switch, hermetically sealed
0.6 513⁄16 1 snap switch, or mercury switch. Optional DPDT or two
1-5/8 3-1/4 4-7/8 6-1/8 [148 mm] [25.4 mm] stage.
[41.28] [82.55] [123.83] [155.58] Electrical Rating: Snap Switch: 12A @ 120 VAC, 5A @
240 VAC, 0.5A @ 125 VDC resistive, 0.25A @ 250 VDC
resistive. Hermetically Sealed Snap Switch: 5A @ 125
Flanged inspection plate allows periodic inspection and clean-out of Model 102 VAC, 5A @ 240 VAC, 5A @ 30 VDC resistive. Mercury
float chamber, making unit ideal for use in refineries, chemical plants, and other areas Switch: 4A @ 120 VAC/DC, 2A @ 240 VAC/DC. Higher
with potentially dirty liquids. Low cost cast iron chamber is standard. Carbon steel and contact ratings available for the mercury switch.
stainless steel chambers are available on special order. Stainless steel float is standard. Electrical Connections: Screw terminal.
Conduit Connection: 3/4˝ female NPT.
Process Connections: 1˝ female NPT.
Mounting Orientation: Vertical.
MODELS Set Point Adjustment: ±1˝ (25.4 mm).
Model Number Switch Type Weight: 35 lb (15.9 kg).
Agency Approvals: UL.
102-WT-4810-C-60 SPDT Mercury Specific Gravity: 0.6 minimum.
102-WT-7810-C-60 SPDT Snap
102-WT-7810HM-C-60 SPDT Hermetically Sealed Snap

236 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg237 7/29/05 9:57 AM Page 1

Series
500 Insertion Type Level Control
Adjustable Deadband, Weatherproof Enclosure ®

SPECIFICATIONS
3-7/8 INSERTION Service: Compatible liquids. Cast iron is not for use
[98.42] with lethal or flammable substances either liquid or
3/4 NPT gaseous.
CONDUIT Wetted Materials:
CONNECTION Body: Cast iron, cast steel, or 316 SS.
9-7/8
Float and Trim: 316 SS.
[250.82] Temperature Limit: 425°F (218°C).
5-1/2 Pressure Limit: 400 psig (27.6 bar).
[139.70] Enclosure Rating: NEMA 4X. Optional general
16°
purpose or explosion-proof.
Switch Type: SPDT snap switch or mercury switch.
1-7/8
[47.62] Optional DPDT or hermetically sealed snap switch.
32° Electrical Rating: Snap Switch: 12A @ 120 VAC, 5A
2-1/2 NPT @ 240 VAC, 0.5A @ 125 VDC resistive, 0.25A @ 250
3/8 5-1/2 VDC resistive. Mercury Switch: 4A @ 120 VAC/DC,
[9.52] 1/2 NPT [139.70]
DRAIN PLUG
2A @ 240 VAC/DC. Higher contact ratings available
for the Mercury switch.
Electrical Connections: Screw terminal.

Level
Adjustable deadband makes Model 500 ideal for control of level in large or Conduit Connection: 3/4˝ female NPT.
Process Connections: 2-1/2˝ male NPT. Optional 2-
small tanks. Mounts directly to threaded fitting on tank. (Flanged mounting avail- 1/2˝ flange.
able on special order.) Stainless steel float operates hermetically sealed mercury Mounting Orientation: Vertical.
switch or SPDT snap action switch. Available in a variety of materials to match Set Point Adjustment: At minimum deadband
setting the set point is adjustable approximately ±1/2˝
most petrochemical and industrial applications. (12.7 mm).
MODELS Weight: 35 lb (15.9 kg).
Agency Approvals: UL.
Model Number Switch Type Body Material Deadband: Adjustable between 0.5˝ (12.7 mm) to 3˝
500T-WT-7810-C.55-12-0 (76.2 mm).
Snap Action Cast Iron Specific Gravity: 0.8 minimum. Optional 0.55
500T-WT-7810-C1.55-12-0 Snap Action Cast Steel minimum.
500T-WT-7810-C216.55-12-0 Snap Action 316 SS Float and Rod Insertion Length: 6.5˝ (165.1 mm).
500T-WT-4810-C.55-12-0 Mercury Cast Iron Optional 12˝ (304.8 mm), 18˝ (457.2 mm), or 24˝ (609.6
500T-WT-4810-C1.55-12-0 mm) rod length. Longer float rods give larger
Mercury Cast Steel adjustable deadband.
500T-WT-4810-C216.55-12-0 Mercury 316 SS

Series
75 Torque Tube Type Level Control
Direct Action, Mercury Contacts ®
®

1 NPT PIPE
PLUG TYP 2 PLACES
1 NPT Ø7/8 [22.23]
TYP 2 PLACES CONDUIT
1-5/8 [41.28]
CONNECTION

FIXED 4-1/4
DEADBAND 12-1/4
[311.15] [107.95]
1 [25.40]
8-1/4
5-3/4 [209.55]
[146.05]
STANDARD
1-5/8 [41.28]
2-11/64
ADJUSTABLE 3-1/4 11-3/8 [55.17]
[288.93] 6
FROM 5-1/8 [130.18] [82.55] [152.40]
TO 7 [177.80] 6-3/4
[171.45]

Torque Tube design eliminates O-rings and packing in Model 75 level con- SPECIFICATIONS
trols. Float assembly removes easily from chamber for periodic inspection. Service: Compatible liquids. Cast iron is not for use with lethal or flammable
“Flow Through” connections reduce piping requirements and installation time. substances either liquid or gaseous.
Wetted Materials: Body: Cast iron, cast steel, or 304 SS. Float: 304 SS.
Torque Tube: Brass or 304 SS. Body Gasket: Carbon.
MODELS Temperature Limit: Cast iron body: 425°F (218°C), cast steel or 304 SS body:
500°F (260°C).
Model Chamber Torque Tube Pressure Limit: Cast iron body: 300 psig (20.7 bar), cast steel or 304 SS
Number body: 400 psig (27.6 bar).
Enclosure Rating: General purpose.
75KM-A-4815 Cast Iron Brass Switch Type: SPDT mercury switch. Optional SPST or two stage.
Cast Steel Brass Electrical Rating: 10A @ 120 VAC/DC, 5A @ 240 VAC/DC.
75KXM-A1-4815 Electrical Connections: Screw terminal.
75KXM-A2-4815 304 SS Brass Conduit Connection: 7/8˝ (22.23 mm) hole for 1/2˝ (12.7 mm) conduit.
75KM-C-4815 Cast Iron 304 SS Process Connections: 1˝ female NPT. Four for side/side or top/bottom
Cast Steel 304 SS mounting.
75KXM-C1-4815 Mounting Orientation: Vertical.
75KXM-C2-4815 304 SS 304 SS Weight: 35 lb (15.9 kg).
Agency Approvals: UL and CSA.
Deadband: Approximately 1˝ (25.4 mm).
Specific Gravity: 0.66 minimum.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 237
pg238 7/29/05 9:56 AM Page 1

Series
201 Side Mounted-Chamber Type Level Control ®
®

Operating Pressures to 500 PSIG, 34 bar, Hermetically Sealed Snap Switch Option
Model 201 liquid level control is designed for long life and reliable operation in chemical
plants, refineries and industrial facilities. Stainless steel switching mechanism uses gravity re-
turn action instead of springs to prolong life. Weatherproof enclosure is standard. Heavy duty,
welded steel float chamber is suitable for 500 psi at 750°F.

4 [101.60]
6-3/4
[171.45]
SPECIFICATIONS Electrical Rating: Snap Switch: 12A @ 120 VAC,
CLEARANCE Service: Compatible liquids. 5A @ 240 VAC, 0.5A @ 125 VDC resistive, 0.25A
FOR COVER Ø5-3/4 Wetted Materials: Body: Carbon Steel. Optional @ 250 VDC resistive. Hermetically Sealed Snap
REMOVAL [146.05] 316 SS. Float and Trim: 303 SS, 304 SS, 316 SS, Switch: 5A @ 125 VAC, 5A @ 240 VAC, 5A @ 30
and 430 SS. Options of 316 SS and 430 SS or all VDC resistive. Mercury Switch: 4A @ 120
316 SS. VAC/DC, 2A @ 240 VAC/DC. Higher contact
3/4 Temperature Limit: Process: 750°F (399°C). ratings available for the Mercury switch.
FEMALE Heat fins should be used for process temperatures Electrical Connections: Screw terminal.
NPT above 500°F (260°C) with mercury switches, Conduit Connection: 3/4˝ female NPT.
ELEC. 3-1/4 Process Connections: 1˝ female NPT and 1˝
CONN. [82.55]
400°F (204°C) with snap switches, and 350°F
(176.7°C) with hermetically sealed snap switches. socket weld hub. Optional flange connections.
18-5/8 Pressure Limit: 600 psig (41 bar) at 100°F Mounting Orientation: Vertical.
[473.08]
B (37.7°C), 500 psig (34 bar) at 750°F (399°C). Set Point Adjustment: ±1˝ (25.4 mm).
Higher ratings available. Weight: 33 lb (14.97 kg).
10-15/16
[277.83] Enclosure Rating: NEMA 4X. Optional general Agency Approvals: UL and CSA.
purpose or explosion-proof. Specific Gravity: 0.6 minimum.
Level

A
Repeatability: ±1/4˝ (6.4 mm).
Switch Type: SPDT snap switch, hermetically
3-3/4 1 FEMALE NPT sealed snap switch or mercury switch. Optional
PROCESS
[95.25]
CONNECTION
DPDT or two stage.
TYP 2 PLACES
MODELS
SP.GR *A B Model
1.0 63/4" (171mm) 3
⁄4" (19 mm) Number Switch Type
0.6 71⁄2" (191 mm) 1" (25.4 mm) 201-WT-4810-C1-60 SPDT Mercury
*A is adjustable ±1" (25.4 mm) 201-WT-7810-C1-60 SPDT Snap
201-WT-7810HM-C1-60 SPDT Hermetically Sealed Snap

Series
391 Side Mounted-Chamber Type Level Control ®

Compact, Low Cost, Hermetically Sealed Snap Switch Option


Heavy duty and low cost is the perfect description for the 391 Series level control. Stainless
steel switching mechanism uses gravity return action instead of springs for long life. Weather-
proof enclosure is standard. Welded steel chamber is good for 650 psig (45 bar) at 600°F (315°C).

Applications
Oil refineries, chemical plants, power generating stations, pumping stations, heat transfer sys-
tems, sanitary/waste water facilities, drip legs, hydraulic systems, boilers.
SPECIFICATIONS Electrical Rating: Snap Switch: 12A @ 120
VAC, 5A @ 240 VAC, 0.5A @ 125 VDC resistive,
Service: Compatible liquids. 0.25A @ 250 VDC resistive. Hermetically Sealed
6-3/4 Wetted Materials: Body: Carbon Steel. Snap Switch: 5A @ 125 VAC, 5A @ 240 VAC, 5A
[171.45] Float and Trim: 303 SS, 304 SS, 316 SS, and @ 30 VDC resistive. Mercury Switch: 4A @ 120
4 [101.60] Ø5-3/4 430 SS. VAC/DC, 2A @ 240 VAC/DC. Higher contact rat-
CLEARANCE [146.05] Temperature Limit: Process: 600°F (315.6°C). ings available for the Mercury switch.
FOR COVER Heat fins should be used for process
REMOVAL Electrical Connections: Screw terminal.
temperatures above 500°F (260°C) with mercury Conduit Connection: 3/4˝ female NPT.
switches, 400°F (204°C) with snap switches, and Process Connections: 1˝ female NPT. Optional
3/4 FEMALE 350°F (176.7°C) with hermetically sealed snap
NPT ELEC. 1˝ socket weld hub or flange connections.
CONN. switches. Mounting Orientation: Vertical.
3-3/4
Pressure Limit: 800 psig (55 bar) at 100°F Weight: 10 lb (4.5 kg).
[95.25] (37.7°C), 650 psig (45 bar) at 600°F (315.6°C). Agency Approvals: UL.
B Higher ratings available. Specific Gravity: 0.8 minimum. Optional 0.7
14-11/16
[373.06] Enclosure Rating: NEMA 4X. Optional general minimum.
purpose or explosion-proof.
6-1/2 Switch Type: SPDT snap switch, hermetically
[165.10] A sealed snap switch or mercury switch. Optional
DPDT.
3-7/16 1 FEMALE NPT
[87.31] PROCESS MODELS
CONNECTION
TYP 2 PLACES Model
SP.GR A B Number Switch Type
1.0 43/8" (111mm) 1" (25.4 mm) 391-WT-4810-C1-80 SPDT Mercury
0.80 411⁄16" (191 mm) 13⁄16" (112.3 mm) 391-WT-7810-C1-80 SPDT Snap
391-WT-7810HM-C1-80 SPDT Hermetically Sealed Snap

238 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg239 7/29/05 9:44 AM Page 1

Series
B-190 Liquid Level Switches-Controls
Top Mounted Displacer Type, Adjustable Setpoints, ®
®

Magnetic Operation, Optional Hermetically Sealed Snap Switch


One of our most versatile level controls, the model B-l90 can be used on all types of tank or sump level con-
trol applications. Three porcelain displacers provide deadband adjustment. Unit can start a sump pump (for
6-3/4 example) when liquid reaches the high set point and turn the pump off when the level drops to the low set
[171.45] point. Unit works equally well in pressurized tanks. Two stage units also available.
3/4 NPT
Ø5-3/4
[146.05]
SPECIFICATIONS Electrical Connections: Screw terminal.
Service: Compatible liquids. Conduit Connection: 3/4˝ female NPT.
9-13/16 Process Connections: 4˝ 125 Cast Iron Flange.
[249.24] Wetted Materials: Cable, Spring and Stops: 316
SS. Optional Inconel spring. Displacers: Porcelain. Other material, size, and rating flanges are available.
Optional 304 SS, 316 SS, or karbate (graphite). Mounting Orientation: Vertical.
3 [76.20] Set Point Adjustment: Adjustable by moving
Temperature Limits: 32 to 200°F (0 to 93.3°C).
Higher ratings available. displacers see dimension chart for minimum and
Pressure Limit: 125 psig (8.6 bar). Higher ratings maximum values.
available. Weight: 25 lb (11.34 kg).
Enclosure Rating: NEMA 4X. Optional general Agency Approvals: UL and CSA.
A purpose or explosion-proof. Deadband: Adjustable by moving displacers see di-

Level
Switch Type: SPDT snap switch, hermetically mension chart for minimum and maximum values.
sealed snap switch, or mercury switch. Optional Specific Gravity: Standard is 1.0. Specify when or-
B OPERATES DPDT or two stage. dering by replacing 1.0 in model number with specif-
ON LEVEL Electrical Rating: Snap Switch: 12A @ 120 VAC, ic gravity setting desired. Settable range is 0.5 to
RISE 5A @ 240 VAC, 0.5A @ 125 VDC resistive, 0.25A @ 1.2.
250 VDC resistive. Hermetically Sealed Snap Cable Length: 10 ft (3 m) standard. Optional up to
C Switch: 5A @ 120 VAC, 5A @ 240 VAC, 5A @ 30 100 ft (30.5 m).
OPERATES VDC resistive. Mercury Switch: 4A @ 120 VAC/DC,
ON LEVEL 2A @ 240 VAC/DC. Higher contact ratings available
DROP for the Mercury switch.
TB
TO
BOTTOM MODELS
Dimensions for 1.0 s.g. @ 100°F (38°C)
Model
A C TB B Number Switch Type
Max. Min. Max. Min. Min. Max. B190-WT-4810-P-A-1.0-2 SPDT Mercury
1161⁄2 " 61⁄2 " 114" 63⁄4 " 21⁄2 " 1221⁄4 " B190-WT-7810-P-A-1.0-2 SPDT Snap
(2.66m) (165m) (2.9m) (172mm) (64mm) (3.1m)
B190-WT-7810HM-P-A-1.0-2 SPDT Hermetically Sealed Snap

Series
GS Gap Switch
Liquid Level Measurement, 1000:1 Wet/Dry Ratio, 316 SS Wetted Parts
13/16 3-3/4
[20.64] [95.25]

2-3/4 3/4 NPT


[69.45] 4
[101.6]
1
[25.40]
3/4 NPT
THREAD HUB
1-1/2 [38.10]

7/8
[22.23]

Series GS Gap Switch measures liquid levels at a single point and SPECIFICATIONS Electrical Rating: 10A @ 120
provides a 10A relay output for high or low level alarm, overflow pre- Service: Compatible liquids VAC resistive.
(1000:1 wet/dry ratio). Power Requirements: 115 VAC,
vention, and pump protection. The Series GS uses ultrasonic wave prop- 50/60 Hz (230 VAC optional).
Wetted Material: 316 SS.
agation between the transducer gap to sense the presence or absence Temperature Limits: Sensor: Conduit Connection: 3/4˝ female
of a liquid. Integral electronics make installation quick and easy. Units –40 to 200°F (–40 to 93°C), NPT.
can be mounted in either a vertical or horizontal position with no addi- Electronics: –20 to 170°F Process Connection: 3/4˝ male
(–4 to 77°C). NPT.
tional calibration required. Gap switch includes a 0.5 second delay and Mounting Orientation: Vertical or
Pressure Limits: 1000 psig (68.9
high level failsafe. bar). horizontal.
Enclosure Rating: Epoxy-coated Delay [On]: 0.5 seconds.
cast aluminum, NEMA 4 & 7. Immersion Depth: 1˝ (25.4 mm).
Repeatability: 2 mm (0.078˝) Weight: 1 lb (453 g).
MODELS typical. Agency Approval: CE.
Model Number Immersion Depth Supply Voltage Switch Type: DPDT.
GS10001 1˝ (25.4 mm) 115 VAC
APPLICATIONS
GS20001 1˝ (25.4 mm) 230 VAC Monitor and control levels of water, chemicals, lubricants, acids,
creams, lotions, beverages or paints in vessels, storage bins, tanks,
sumps, etc.
CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 239
pg240 7/29/05 9:44 AM Page 1

Model
CLS1 Capacitance Level Switch
For Solids, Liquids or Slurries, Fail-Safe Protection, <1 pF Sensitivity
1-11/16
[42.88] 6-3/16
[157.15]

7/8
[22.23] 21/32
1/2 FEMALE
[16.67]
NPT CONDUIT
CONNECTION 1 MALE NPS
PROCESS 1-13/16
CONNECTION [46.05] 8-5/8
[219.08]

3-13/16
[96.84]
1-7/64
[28.18]

Model CLS1 Capacitance Level Switch provides reliable point SPECIFICATIONS Conduit Connection: 1/2˝
level measurement of solids, liquids and slurries in metallic or non- Service: Solids, liquids, or slur- female NPT.
metallic tanks and vessels. Model CLS1 detects the presence or ab- ries. Process Connection: 1˝ male
Level

Wetted Material: CPVC. NPS.


sence of material in contact with the probe by sensing a change in the Mounting Orientation: Vertical
Temperature Limits: Probe:
capacitance. Electronics provide highly sensitive measurement detec- or horizontal.
-40 to 240°F (-40 to 116°C),
tion (requires less than a 1 picofarad shift from ambient). State of the Electronics: -40 to 185°F (-40 to Sensitivity: Adjustable to <1 pF.
art technology ignores material build-up on the vessel sidewall or along 85°C). Fail-Safe: Switch Selectable,
the probe assembly. One time calibration is simple with a single multi- Enclosure Rating: NEMA 4X high/Low.
turn potentiometer. Red LED on housing indicates sensor status. Unit (IP56), PVC, dust tight, water Time Delay: Adjustable 1 to 30
resistant. seconds.
features an adjustable 1-30 second time delay and a 5 amp, SPDT fail-
Switch Type: SPDT. Weight: 2.0 lb (0.91 kg).
safe relay output. Model CLS1 can be mounted vertically or horizon- Agency Approvals: CE.
Electrical Rating: 5A @ 250
tally. VAC.
Power Requirements: 120
VAC, 1.5VA.
Model CLS1 Capacitance Level Switch
APPLICATIONS
High or low level detection in bins, silos, tanks, hoppers, chutes and
other vessels where liquids, solids or slurries are stored.

Series
RFC RF Capacitance Level Switch
For Liquids or Powder Bulk Solids, One-Button Calibration, Integral Electronics
3/4" CONDUIT
4.13 17.6
[105] [447]

3/4" NPT(M)

Ø4.63 Ø.375
[118] [10]

.95 3.30 3.35


[24] [83] [85]

8.35 13.4
[212] [340]

Monitor liquids and powder bulk solids with Series RFC RF Ca- SPECIFICATIONS
Service: Liquids and powder bulk solids.
pacitance Point Level Switch. Microprocessor based Series RFC pro- Wetted Materials: 316 SS probe with NorylTM guard.
vides a 5 amp DPDT relay output for level detection. Heavy material Temperature Limits: Electronics: -40 to 160°F (-40 to 71°C).
build-up on the probe does not effect operation. Pressure Limits: 650 psig (44.8 bar).
Enclosure: NEMA 4X (IP56), dust tight, water resistant.
Switch Type: DPDT.
Unit is designed with integral electronics and includes one-touch cali- Electrical Rating: 5A @ 115/230 VAC non-inductive.
Power Requirements: 110/220VAC.
bration. Series RFC features LED indication (located inside the hous- Conduit Connector: 3/4˝ female NPT.
ing) of relay and probe status, adjustable time delay, high/low failsafe, Process Connector: 3/4˝ male NPT.
and NEMA 4X (IP56) enclosure. Mounting Orientation: Vertical.
Sensitivity: Factory set @ 5 pF, adjustable to < 2 pF.
Fail-Safe: Selectable high/low.
MODEL Time Delay: Adjustable 50 ms to 30 seconds.
Weight: 5.0 lb (2.3 kg).
Model Number Guard Material
APPLICATIONS
RFC0420 NorylTM High or low level detection in bins, silos, tanks, hoppers, chutes and other
vessels where liquids or powder bulk solids are stored.

240 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg241 7/29/05 9:43 AM Page 1

Series
RF Level Control
Radio Frequency Sensing for Liquids and Solids, Remote High/Low Control

Series RF Level Controls employ radio frequency technology to pre- SPECIFICATIONS Conduit Connection: Probe: 3/4˝
cisely monitor the level of almost any liquid or solid. Probes are unaffected Service: Compatible liquids. female NPT. Control Box: Pg16, 21
by product build-up, even with problem materials like latex paint, which Wetted Materials: and 29 punch-outs.
can quickly disable most mechanical controls. Each unit is quickly and eas- Connection: 316 SS. Process Connection: 3/4˝ male
ily calibrated in the field for the unique dielectric constant characteristics Probe: 316 SS or Teflon®. NPT.
of the specific product being controlled. No moving parts means years of Insulator: Teflon®. Mounting Orientation: 316 SS
Temperature Limits: Probe: -40 probe can only be vertically

Level
dependable service. A complete system requires a sensing probe and sep- mounted. Teflon® covered probe
arate control box. to 250°F (-40 to 121°C), Control
Box: -10 to 160°F (-23 to 71°C). can be vertically or horizontally
MODELS Pressure Limit: 100 psig (6.89 mounted.
Model No. bar). Optional 1000 psi (68.9 bar). Set Point Adjustment: Trips when
Description
Enclosure Rating: Probe: product touches the probe. Field
Single RF101 316 SS probe, 12" length x 1⁄4" dia. Weatherproof and explosion-proof, trim the probe to desired trip point.
Probe RF102 316 SS probe, 24" length x 1⁄4" dia. NEMA 4, 7, 9. Class I, Div. 1 & 2, Weight: 12˝ Probe: 3.4 lb (1.54 kg).
RF105 316 SS probe, 60" length, 1⁄4" dia. Groups C & D; Class II, Div. 1 & 2, Control Box: 1.8 lb (0.82 kg).
RF301 Teflon® coated probe, 12" length x 1⁄4" dia. Groups E, F, and G. Control Box: Time Delay: Selectable to: Off, 0
Weatherproof, NEMA 4X. to 30 seconds up to 15 seconds to
Switch Type: DPDT form C 2 hours.
Control Box RFC1 Single probe control contact. Options: Probes up to 25 ft (7.62
RFC2 Dual probe control Electrical Rating: 2A @ 115 VAC. m), 7/8˝ diameter probe for
Note - Order two single probes for dual probe configuration. Power Requirements: 110/120 materials with a dielectric constant
VAC, 50/60 Hz; 220 VAC; 24 VDC. below 20, 1000 psi (68.9 bar)
A-630, 4"x3⁄4" NPT, 125 lb. Cast iron flange for quick,convenient mounting of standard RF probes. Current Consumption: 5 VA. pressure rating.
Electrical Connections: Screw
terminal.

Model
DPL110 Dual Point Level Switch
Tank High/Low Control, Conductivity Technology, Up to 72” Probes ®

3.11
[79] Ø2.26
[57]
1.40 2.385
[35] [60.58]

27.1
2.25 1" MALE NPT [687]
[57] 24.00
[610]
1.75 2.81
[71] 3.73
[44] [95] 0.13
[3.2]

Maintain liquid level high and low limits with the Model SPECIFICATIONS
DPL Dual Point Level Switch. Units can be used for single or Electrodes: 1/8 ˝ dia, 24˝ (609.6 mm) length, standard.
dual point level control in semi-solid liquids, industrial slurries Wetted Materials: 316 SS, polypropylene.
or heavy-bodied liquids like wastewater. Standard 24 inch elec- Mounting, Sensor Head: 1˝ male NPT.
trodes can be cut by the end-user to a shorter length or length- Pressure Limits: 30 psig (2.06 bar).
Temperature Limits: 212°F (100°C).
ened by adding up to two 24 inch extensions (sold separately)
Probe Enclosure: NEMA 6 (IP67).
to reach the maximum recommended length of 72 inches. Model Maximum Probe Length: 72˝ (1.8 m) with optional extensions.
DPL contains no moving parts to get stuck or wear out. Con- Connecting Cable, Probe to Controller: 10 ft (3.0 m).
troller features adjustable sensitivity and DIN rail-mountable Sensing Voltage: 12 VAC.
socket mount. Power Supply: 120 VAC 50/60 Hz.
Output: SPDT, 5 A @ 240 VAC.
Model DPL110 Dual Point Level Switch Mounting, Controller: Standard octal socket or 35 mm DIN rail.
Weight, Probe Assembly: 1.5 lbs (0.68 kg).
ACCESSORIES Weight, Controller: 1.0 lb (0.45 kg).
Model DPL5 Electrode Extensions includes two 249 (610 mm)
electrode extensions and mounting hardware

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 241
pg242 7/29/05 9:42 AM Page 1

Series
LLC Conductivity Controller ®

Single Point or Differential Level Service, Compact Size, Up to 6 ft. (1.82 m) Probes
Control valves, pumps and alarms with the versatile
Series LLC Conductivity Level Controller. Select the
required number of probes for single or dual point level
detection. Choose probe lengths in 1-foot increments (up
to six feet) to adapt the LLC to your specific applications
requirements. The LLC features rugged 1/4-inch
(6.3 mm) diameter, stainless steel probes, LED monitor-
ing, surge protection, low voltage sensor and different
mounting options.
Level

To build your level switch:


Controller:
1. Determine your supply voltage. Select
between 120 and 240 VAC.
2. Determine the required sensitivity. Select
between 10 K Ω and 26 K Ω.
3. Determine the socket style. Select between
Controllers 8-pin octal and DIN mount.
Model Supply Voltage Sensitivity Socket Style Probes:
LLC-118 120 VAC 10K Ω 8-Pin Octal 4. Determine the required number of probes. Specify
LLC-128 120 VAC 26K Ω 8-PIN Octal
quantity of Threaded Mounting Couplings, model
LLC-115 120 VAC 10K Ω DIN Mount
LLC-125 120 VAC 26K Ω DIN Mount LLC-82. (A coupling is required for each probe.)
LLC-218 240 VAC 10K Ω 8-Pin Octal 5. Select probe lengths. Specify model numbers
LLC-228 240 VAC 26K Ω 8-Pin Octal for probes.
LLC-215 240 VAC 10K Ω DIN Mount
LLC-225 240 VAC 26K Ω DIN Mount

SPECIFICATIONS
Service: Electrically conductive fluids.
Wetted Materials: 316 SS, Teflon®.
Probes Temperature Limits: Controller: -40 to 150°F (-40 to
Model Length feet(m) 65°C); Probes: 406°F (207°C).
LLC-31 1 (.3) Pressure Limits: Probes: 400 psig (27 bar).
LLC-32 2 (.6) Switch Type: SPDT, N.O. or N.C.
LLC-33 3 (.9) Electrical Rating: 10A resistive, 1/3 hp, 120/240 VAC.
LLC-34 4 (1.2) Power Requirements: 120 VAC or 140 VAC.
LLC-35 5 (1.5) Process Connection: 3/8˝ male NPT.
LLC-36 6 (1.8) Electrodes: 1/4˝ (6.3 mm) diameter, 316 SS.
Maximum Probe Length: 72˝ (1.82 m).
Controller Sensitivity: 10 KΩ or 26KΩ.
Mounting: Controller: 8 pin octal or DIN mount; Probes:
3/8˝ male NPT.
Threaded Mounting Couplings Weight: Controller: 6 oz (170 g).
Model LLC-82

242 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg243 7/29/05 9:42 AM Page 1

Model
DBLM Mini-Bin Dry Bulk Level Monitor
Compact, 4-Vane Paddle

SPECIFICATIONS
The Mini-Bin provides reliable level sensing for dry bulk solids Service: Dry bulk solids.
where mounting space is limited. This compact, side mount control reports Wetted Materials: Polycarbonate paddle, SS shaft, Teflon® washer.
high, intermediate, and low level conditions, eliminating overflows, chok- Temperature Limits: -4 to 140°F (-20 to 60°C).
ing, clogs or empty vessels. Model DBLM Mini-Bin operates by using a 1 Enclosure Rating: Polycarbonate, NEMA 1.
Switch Type: SPDT snap switch.
rpm synchronous motor to rotate a four vane, plastic paddle. When mate-

Level
Electrical Rating: 3A @ 250 VAC.
rial surrounds paddle and impedes rotation, the motor is de-energized and Power Requirements: 110 VAC, 50/60 Hz, 220 VAC optional, consult factory.
triggers a SPDT snap switch. Mount the Mini-Bin with optional 11⁄4" to 3⁄4" Power Consumption: 1.5 Watts.
reducer to replace standard size units. Electrical Connections 18 AWG, 12˝ leads wrapped in conduit.
Process Connection: 3/4˝ male NPT, optional flange and 1-1/4˝ to 3/4˝ reducer.
MODELS Mounting Orientation: Side mount.
Weight: 0.77 Ib (350 g).
Model Number Power Supply Agency Approvals: CE.
DBLM3040 110 VAC
DBLM3140 Suggested Specifications
220 VAC Miniature dry bulk level control shall be vane operated to actuate a SPDT snap action
F1, 8"x 11⁄4" NPT flexible carbon steel mounting flange switch. Power consumption shall be 1.5 watts. The motor shall de-energize when rota-
A-335, 11⁄4" to 3⁄4" reducer tion is impeded. The housing shall be plastic, suitable for NEMA 1 service. Switch
shall be Proximity Model No. DBLM 3040.

NEW! Technical Reference Books


Instrumentation Plant Engineer’s Guide to the 2005
Pumps & Hydraulics Reference Book Handbook National Electric Code

Sixth Edition Third Edition Edited by By Paul


By Rex Miller Edited by R. Keith Rosenberg,
& Mark Walt Boyes, Mobley, 2001 2004
Richard Miller, 2002
2004

• Learn to install and service • Great reference for anyone • Produced in association with • Understand the terms and
pumps for nearly any applica- in the process, control and Plant Engineering Magazine rules for installation set forth
tion instrumentation fields and created by leading authors in the NEC
where measurements are and editor.
• Service and maintain individ- essential. • Learn about the significant
ual pumping devices that use • International perspective with changes in bonding and
smaller motors • ISBN: 0750671238, dual units and regulations. grounding requirements
Pages: 1062, Hardback
• ISBN: 0764571168, Pages: • ISBN: 0750673281, • ISBN: 0764578022,
556, Paperback Pages: 2400, Hardback Pages: 816, Paperback

Order Number: Order Number: Order Number: Order Number:


BK-0009 BK-0002 BK-0003 BK-0012

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 243
pg244 7/29/05 9:13 AM Page 1

Explosion-Proof Ultra Mag Level Switches


For Powder & Bulk Solids ®


®

SUSPENSION HUB – 1 NPT

Sealed
Junction Box

Driving Epoxy Seal DIAPHRAGM 7-1/2


Magnet
DIAMETER 5-7/8
Sealed
Driven Switch Cavity
Magnet

3-1/8

U.S. Patent #3,368,173, 3,349,203 Canadian Patent #801,168; 821,621 Suspension mounting
Level

Flange Adapter Ring CONDUIT ENTRANCE


1/2 NPT

(6) 5/16 DIA. HOLES


ON 8-3/8 B.C.

9-1/8
DIAPHRAGM
DIAMETER 5-7/8 7-1/4

3/8
3-1/8

U.S. Patent #3,368,173, 3,349,203 Canadian Patent #801,168; 821,621


Flange mounting
A unique, patented Magnetic Linkage isolates the electrical com- SPECIFICATIONS
partment from controlled product, reducing maintenance and improv- Service: Compatible powder or bulk solids.
ing sensitivity. The sealed switch compartment and sealed leads yield Wetted Materials:
the utmost in reliable operation. A wide selection of diaphragms and Mounting Flange: See model chart. Aluminum or 304 SS.
switches are available with choices of flange or suspension mounting to Diaphragm: See model chart. Urethane, Buna-N, Teflon®, Silicone
fit your specific application. The dry level Ultra-Mag™ is extremely sen- Rubber, Polyester, Viton®, White Buna-N (food grade), or EPDM.
sitive and very economical. The magnetic linkage makes this simple ex- Temperature Limits: Depends on diaphragm material, see model
plosion-proof diaphragm switch the most rugged and reliable level chart. Standard switch: -40 to 185°F (-40 to 85°C), High tempera-
control for a variety of products (see cut-away above). ture switch: -40 to 350°F (-40 to176°C).
Pressure Limit: 60 psig (4.14 bar).
Mounting Selection: A choice of either suspension or flange mount- Enclosure Rating: General purpose or weatherproof and
ing is available to match your application. Flange mounting is the best explosion-proof. See model chart.
choice for control of low or intermediate level in vessels containing Switch Type: See model chart.
granular product that does not “bridge”, “rathole”, or otherwise build Electrical Rating: See model chart.
up on vessel walls. Choose suspension mounting for high level in ves- Electrical Connections: 18 gage solid core, 600 volt TEW
sels and for better operation with “bridging” product. See next page 105°C, style 1015. Epoxy sealed at conduit entrance. 12˝ (304.8
for more information on suspension and flange mounting kits. Note mm) long.
that the mounting configuration is represented by the letter “S” for Conduit Connection: 1/2˝ female NPT.
suspension or “F” for flange which is the second digit in the part num- Process Connection: For flanged models standard is 8-3/8˝
ber on the next page. (212.725 mm) diameter bolt hole circle.
Mounting Orientation: Flange mount or suspend depending on
Diaphragm Selection: A wide variety of diaphragms are available to
model.
match product bulk density, flowability, abrasiveness and temperature
Set Point Adjustment: Internal screw.
requirements while providing maximum sensitivity. The best choice for
Weight: 7 lb (3.18 kg).
vessels subject to pressure or vacuum is “breathable” fabric (P Se- Options: Suspension kits and flange adapter rings.
ries), requiring no venting. Non-porous elastomer (G Series) type di- Agency Approvals: UL and CSA.
aphragms are the best choice for more abrasive product and broader
temperature range applications. Venting is always required with the G
series and if used in pressurized vessels, venting to the tank atmos-
phere is required to allow pressure equalization. A slide rule “Di-
aphragm Selector” is available from the factory to help you choose the
diaphragm best suited to your application.

244 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg245 7/29/05 9:40 AM Page 1

Proximity Ultra Mag Level Switch


Complete Model Chart Consult factory for pricing on UltraMag™ switches


PREFIX - Certification
Diaphragm Selection Guide E X = Explosion-proof (UL & CSA) Class I, Div I & II, Groups C & D; Class II, Div I & II, Groups E, F, & G.
X = Explosion-proof (CSA) Class II, Div I & II, Groups F & G.
Suggested Suggested Suggested
Product Diaphragm* Product Diaphragm* Product Diaphragm* 1ST DIGIT-Basic Magnetic Pressure Sensing Series
Abrasive............................3D Gravel ...............................3D Sand, Foundry Prepared .......5A G = Elastomeric Diaphragm-Venting required*. (Diaphragms 1A - 8A)
Aggregate .........................3D Iron Ore, Crushed .............3D Sand, Shake Out ..................3D P = Breathable Fabric Diaphragm-No venting required. (Diaphragms 16 & 17 only)
Alumina.............................3D Kaolin Clay........................3D Sawdust, Dry ........................6G
Ash, Dry............................3D Lime, Hydrated .................5A Sea Coal ...............................3D 2ND DIGIT-MOUNTING (Top = Suspension/Side=Flanged)
Baking Powder .................7B Lime, Stone ......................3D Sesame Seed ......................3D S = Suspended (G series require suspension vent fittings)* Subtract 10 lbs./cu. ft.-greater sensitivity.
Baking Soda .....................7B Oats..................................4B Shale, Crushed .....................3D F = Flanged, Aluminum standard
Barite ................................3D Peanuts in Shell ................7A Silica, Flour ..........................3D T = Flanged, 304 SS
Bark, Ground ...................6G Peanuts, Shelled...............3D Sludge, Sewage Dried ..........1A
Barley, Ground or Meal ......17 Perlite ...............................7A Sludge, Sewage, Ground ......1A
3RD DIGIT-HOUSING MATERIAL
Barley, Whole ....................4B Phosphate, Rock ..............3D Soda Ash..............................3D D = Aluminum
Beans, Edible,...................4B Polyethylene Powder.........7A Soybeans, Cracked ..............3D A = Aluminum, Anodized
Bentonite ..........................3D Polyethylene Resin ............17 Soybean, Flake .....................7A E = Aluminum, Epoxy Coated
Bond, Foundry ..................17 Polypropylene Fluff............7A Soybean, Flour, .....................7A 4TH & 5TH DIGITS-DIAPHRAGM MATERIAL (TEMPERATURE) (BULK DENSITY)
Carbon Black ....................7A Polypropylene Powder ......7A Soybean Meal .......................3D G 1 A = Viton®, black, .025˝ thick, (25 to 300°F), (>30 lbs/cu ft)
Cement, Klinker ................8A Polypropylene Resin..........17 Soybean, Whole....................3D 2 A = Neoprene, black, .025˝ thick, (-30 to 220°F), (>30 lbs/cu ft)
G
Cement, Portland..............4B Polystyrene Beads ............3D Sugar Beets, Whole ..............6H
G 3 D = Urethane, .031" thick (10 to 150°F) (>30 lbs./cu.ft)
Chips, Hogged Fuel ..........6G Pot Ash.............................3D Sugar Refined .......................7B
G 3 E = Urethane, orange, .062˝ thick, (10 to 150°F), (>90 lbs/cu ft)

Level
Coal..................................3D Powdered Metal ...............3D Sunflower Seed.....................7A
Compost...........................5A Powdered Ore ..................3D Taconite Pellets .....................3D P 3 F = Urethane, “3D” elastomer w/bumper for removable overlays, orange,
Core Sand, Foundry..........3D PVC Powder .....................7A Talcum Powder .....................3D P (10 to 150°F), (>90 lbs/cu ft)
Corn, Shelled ....................8A PVC Resin.........................17 Walnut Shells, Crushed .........3D G 4 B = Buna-N, black, .020" thick (-20 to 212°F) (20 to 90 lbs./cu.ft.)
Diatomaceous Earth..........7A Rice ..................................17 Wheat ...................................8A G 5 A = Teflon®/Glass on Sil Rubber, .024" thick (-40 to 350°F) (>35 lbs./cu. ft)
Drill Mud ...........................3D Rye...................................3D Wheat, Wet ...........................5A G 6 D = Silicone Rubber, gray, .062˝ thick, (-40 to 350°F), 15 to 30 lbs/cu ft)
Flour .................................7B Salt ...................................3D Wood, Chips.........................6G G 6 E = Silicone Rubber on Glass, red, .032˝ thick, (-40 to 350°F), (>90 lbs/cu ft)
Fly Ash..............................3D Sand, Dry .........................3D Wood, Dust ..........................6G G 6 G = “6C” w/Urethane overlay, (-40 to 350°F) (wood chips diaphragm with “A2”)
Glass Batch ......................3D Sand, Dry Silica ................3D G 6 H = “6C” w/bumper for removable overlays 901-120, -132, -134, gray, (-40 to 350°F),
*Diaphragm codes become 4th and 5th characters in model number. (>90 lbs/cu ft)
G 7 A = Silcone Rubber on Glass (White), .015" thick (-40 to 350°F) (5 to 40 lbs./cu. ft.)
G 7 B = Buna-N (Food Applications-white), .060" thick, (-20 to 212°F) (30 to 90 lbs./cu. ft.)
G 8 A = EPDM, black, .036" thick, (-40 to 275°F) (40 to 90 lbs./cu. ft.)
P 1 6 = Polyester Filter Fabric, white, 150 micron permeability (-30 to 275°F)
(30 to 90 lbs./cu. ft.)
P 1 7 = Polyester Nitex, white, 15 micron permeability (-30 to 275°F)
(30 to 90 lbs./cu. ft.)
GSD3DA 6TH DIGIT-SWITCH TYPE
GFD3DA A = Standard, SPDT, 15A @ 125, 250 VAC
PSD16A T = High Temp, SPDT, 5A @ 125, 250 VAC; 24 VDC(**)
V = High vibration, SPDT, 15A @ 125, 250 VAC
PFD16A G = Gold contacts, SPDT, 1A @ 125 VAC, 1⁄2 A @ 24 VDC
SUFFIX-SPECIAL CONTROLS
-A1 = D/P with Diaphragm cover plate
-A2 = Wood Chip Control (with “6G” diaphragm only)
-A3 = High sensitivity actuator (for very light product)
EX G S D 3 D A = EXAMPLE MODEL NUMBER* A

* GS - G series suspended controls require suspension vent fittings.


Suspension Mounting is normally used for (**)Non-UL/CSA listed
high level monitoring in vessels. For product Note: The “EX” prefix must he added to the 6-digit model number for “explosion-proof standard”. General
purpose units do not require the “EX” or other prefix. See the “Complete Model Chart” on this page.
over 20 pounds/cu. ft., the level switch (di-
aphragm face) should be located about 1⁄3 of the
distance from the vessel wall to the point of
entry of the product. For product less than 20
Suspension Assembly Kits
“P” and “G” Series Suspension Assembly Kits
pounds/cu. ft., the unit should be located clos- Part# Description
er to the point of entry of the product, about 1⁄2
the distance from the vessel wall to the point 901-409 “P” Series Suspension Assembly includes 1⁄2"
pipe (56" Std length), 1" pipe (48" Std length),
of entry. Pressure required to depress the diaphragm and trip the 1" pipe coupling, 11⁄2" NPT strain relief on 1"
switch is in the range of 5–15 oz in the horizontal direction (perpen- pipe. Galvanized mild steel pipe, explosion
dicular to the diaphragm). Suspension mounting provides the easiest proof, standard.
vertical adjustment capability, greatest sensitivity and best mainte-
nance conditions. 901-412 “G” Series Suspension Assembly includes 1⁄2"
pipe (56" Std length), watertight strain relief
and 1" coupling, upper 1" pipe (28" Std length),
Suspension Assembly Kits: Pre-assembled kits are available from lower 1" pipe(20" Std length), strain relief with
the factory, or you can build your own kits using standard pipe fittings 11⁄2" NPT, 1" X 1" X 1" Tee,1" Street
shown in our Proximity Bill of Materials (Form No. 101). Pipes and fit- Ell and 1" pipe-4" long Stilling Pot. Galvanized
tings are normally galvanized steel, but aluminum and stainless steel steel pipe, explosion proof, standard.
pipes and fittings are available. Units pictured on the previous page Specials include aluminum or stainless steel assemblies. Flange
are secured to a steel cover plate that rests on a rectangular steel port and cover assemblies are sold separately. CONSULT FACTORY
for details.
flange welded into the top of the vessel. Aluminum and stainless cov-
erplates and flanges are also available. Standard 48" long x 1" pipe pro-
vides working depth (WD) up to 48". Longer pipe (to provide greater
WD) is available. GS Series switches have upper (L1 = 28" standard) Aluminum Flange Adapter Rings
and lower (L2 = 20" standard) 1" pipes, with a tee (for stilling pot) in be- Part# Tank OD Part# Tank OD
tween. A stilling pot is required to equalize pressure and keep dirt 126-009 15" 126-016 84"
from building up behind the diaphragm. PS series require a 1⁄2" conduit 126-010 30" 126-017 96"
in 1" suspension pipe for explosion-proof applications. The 1⁄2" conduit 126-011 36" 126-018 10'
126-012 42" 126-019 12'
(56" standard length) is a standard part of the GS series assembly. 126-013 48" 126-020 14'
126-014 60" 126-021 24'
126-015 72"
Note: OD = Outside Diameter

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 245
pg246 7/29/05 9:35 AM Page 1

Series
PLS Paddle Level Switch
Economical Rotary Paddle Level Control, Top or Side Mounting for Dry Bulk Materials

SIDE MOUNT

3/4" CONDUIT
CONNECTION PDL-1. Minimum bulk PDL-2. Minimum bulk
density of 5 lb/ft3 (80 density of 30 lb/ft3 (481
kg/m3). kg/m3).

4-11/32
[110.31]

4-1/2 4-31/32
[113.69] [126.19]
CLEARANCE FOR 6-3/8
COVER REMOVAL [162.05] 8-33/64
Level

[216.26] 10-5/16 PDL-3. Minimum bulk PDL-4. Minimum bulk


density of 30 lb/ft3 (481 density of 70 lb/ft3 (1122
[261.92] kg/m3). Fits through a 1- kg/m3). Fits through 1-
1/4˝ coupling eliminating 1/4˝ coupling eliminating
the need for a mounting the need for a mounting
flange. flange.

Incorporated in the design of the PLS is a magnetic drive that is SPECIFICATIONS


time proven by decades of use in our Mark Series valve position indi- Service: Dry powder or bulk materials compatible with wetted
cator product line. A 1 rpm synchronous motor rotates the paddle uti- materials.
lizing a magnetic drive. As product builds up the paddle is impeded
from moving and the resulting motor torque activates the output Sensitivity: Minimum material density of 5 lb/ft3 (80 kg/m3), maxi-
switches and stops the motor. A spring mechanism reactivates the mum of 200 lb/ft3 (3200 kg/m3).
motor and returns the switches to normal state when the product no Wetted Materials:
longer impedes the paddle rotation. Paddles: 316 SS. Exposed Shaft: 316 SS. Shaft Seal: PTFE.
Mounting Boss: Aluminum. Flexible Coupling: 316 SS.
Standard construction is weatherproof with explosion-proof optional, Mounting Flanges: Carbon Steel or 316 SS.
and the unit can be side or top mounted. The PLS is designed with the
industry standard 1-1/4˝ male NPT connection and mounting flanges. Shaft Extension and Shaft Guards: Galvanized Steel or 316 SS
Temperature Limits:
FEATURES Standard Construction: Process: -40 to 300ºF
• Magnetic drive that isolates and completely seals the control head from (-40 to 148.9ºC), Control Head: -40 to 200ºF
the process and environment preventing material or dust from entering
the control head. (-40 to 93.3ºC).
• Motor shuts-off when paddle stalls increasing motor life, preventing High Temperature Option: Process: -40 to 500ºF
motor burnout, and decreasing power usage. (-40 to 260ºC), Control Head: -40 to 185ºF (-40 to 85ºC).
• Slip clutch design enabled by the magnetic drive that prevents damage Pressure Limit: 30 psig (2.07 bar) maximum for .5 micron or
to motor and drive mechanism from sudden or excessive loading on the
paddle. larger material.
• Status indication light on weatherproof models. Power Requirement: Select by part number: 110-120 VAC, 230
• Screw cover on the enclosure for easy access with no worries about los- VAC, 24 VAC, 48 VAC, 12 VDC, or 24 VDC.
ing bolts or screws. Power Consumption: Weatherproof models: 5 watts, Explosion-
• Modular design to allow field installation of any paddle, flanges, shaft proof models: 3 watts.
extensions, or shaft guards.
Enclosure: Aluminum, powder coated.
MODELS Enclosure Rating: Weatherproof (W, WH construction): NEMA 4X,
CONTROL DESCRIPTION Explosion- proof (E, EH construction): NEMA 4X and rated for
ASSEMBLIES Class I, Div. 1 & 2, Groups C & D, Div. 1 & 2, Groups E, F, & G.
PLS-W-S-1-0-0-0-0 Weather construction, SPDT switch, 120 VAC Switch Type: SPDT or optional DPDT snap switch.
power supply. Order paddles and flanges Electrical Rating: 15A @ 120/230 VAC, 5A @ 24 VDC.
separately. Electric Connections: Screw terminals.
PLS-W-S-1-3-0-0-0 Weatherproof construction, SPDT switch, 120 Conduit Connection: 3/4˝ female NPT.
VAC power supply, includes PDL-3 paddle.
PLS-W-S-1-2-CSH-0-0
Process Connection: 1-1/4˝ male NPT. Optional flange.
Weatherproof construction, SPDT switch, 120
VAC power supply, includes PDL-1 paddle and
Weight: Control head only: 4 lb (1.81 kg).
FLG-CSH flange. Indication Light: Red LED that activates when switch is made or
when switch is not made with RL option (Not available on
PADDLES Explosion-proof models).
(See top of FLANGES DESCRIPTION Options: Time delay relay, high temperature construction, top
page) mount, shaft extensions, shaft shields, flexible couplings, other
PDL-1 FLG-CSH Carbon Steel with Half Coupling. power voltages, reversed light.
PDL-2 FLG-CSF Carbon Steel with Full Coupling. Agency Approvals: UL approved as an auxiliary device or as an
PDL-3 FLG-SSH 316 SS with Half Coupling.
auxiliary device for hazardous locations.
PDL-4 FLG-SSF 316 SS with Full Coupling.
Contact the factory for pricing of shaft extensions, protective shields, and other options. More detailed information available in our “Dust Collection &
Pneumatic Conveying” Catalog.

246 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg247 7/29/05 9:36 AM Page 1

Liquid Level Switches


For Sludge, Slurry, or Liquids
S-D™ Liquid Level Switch A unique patented Magnetic Linkage in the S-D™ Liquid Level Switch
isolates the electrical compartment, containing one or two switches, from
controlled product. This reduces maintenance and improves sensitivity.
The sealed switch compartment and sealed leads yield highly reliable op-
eration. A variety of switch types, options, mounting choices and thumb-
wheel adjustable ranges is available to fit your specific application. The
S-D™ is very sensitive and economical. The force required to depress the di-
aphragm and trip the switch(es) is in inches of water column. The simple
design has been proven rugged and reliable providing long life in the most se-
vere applications.
SPECIFICATIONS Electrical Connections: 18 gage
Service: Compatible liquids. solid core, 600 volt TEW 105°C,
Wetted Materials: style 1015. Epoxy sealed at
Mounting Flange: See model chart. conduit entrance. 36˝ (914.4 mm)
Aluminum, carbon steel, PVC, or long.
316 SS available. Conduit Connection: 1/2˝ female
Diaphragm: See model chart. NPT.
Viton®, Neoprene, Urethane, Buna Process Connection: See model

Level
chart. 2˝ flange, 3˝ flange, 4˝ flange,
MODELS N, Teflon®, Silicone rubber, or food
1/2˝ to 3˝ NPT, or suspended
grade available.
Model Description Temperature Limits: 180°F available.
(82.2°C) suspended in liquid, 220°F Mounting Orientation: Flange
S-D™ with 1 standard switch, 4˝ aluminum flange (6- mount, screw in, or suspend
A1FP20 12˝ range), neoprene diaphragm, anodized aluminum
(104.4°C) exterior tank mounted.
Pressure Limit: 75 psig (5.2 bar). depending on model.
housing Set Point Adjustment: Internal
Enclosure Rating: Weatherproof
S-D™ with 2 standard switches, 4˝ aluminum flange and submersible. screw. Adjustable anywhere within
A2FS20 (6-12˝ & 6-12˝ ranges), neoprene diaphragm, Repeatability: ±1 to 3% of full the pressure range.
anodized aluminum housing range. Contact factory for specific Weight: 6 lb (2.72 kg).
values. Ranges: 6 to 12˝ w.c. (1.49 to 2.99
S-D™ with 2 standard switches, 3˝ carbon steel
Switch Type: SPDT snap switch or kPa), 11 to 24˝ w.c. (2.74 to 5.97
A2IV20 flange adapter (6-12˝ & 22-48˝ ranges), neoprene
diaphragm, anodized aluminum housing SPDT gold contact snap switch. kPa), and 22 to 48˝ w.c. (5.47 to
One or two switches available. 11.9 kPa).
S-D™ with 2 gold switches, 4˝ aluminum flange (6-12˝ Electrical Rating: Snap Switch: Deadband: Approximately 20% of
A5FS20 & 6-12˝ ranges), neoprene diaphragm, anodized alu- 15A @ 125/250/480 VAC. Gold range. Contact factory for specific
minum housing Contact Snap Switch: 1A @ 24 values. Optional wide deadband of
VDC/125 VAC. approximately 50%.
Options: Suspension kits and dip
tube kits.

Sliquid™ Liquid Level Switch This top-of-the line Sliquid™ Level Switch has the unique, patented Mag-
netic Linkage that completely isolates the electrical compartment, con-
taining 1, 2 or 3 switches, from controlled product. Maintenance is thus
reduced and sensitivity improved. Sealed switch compartment and sealed
leads yield the utmost in reliable operation. A variety of switches, mount-
ing choices and the broadest range of adjustability is available with the Sliq-
uid™ Level Switch. The force required to depress the diaphragm and trip
the switch(es) is in inches of water column. The increased adjustment ca-
pability is provided by a different spring and screw design versus the S-D™
thumbwheel design.

SPECIFICATIONS Electrical Connections: 18 gage


Service: Compatible liquids. solid core, 600 volt TEW 105°C,
Wetted Materials: style 1015. Epoxy sealed at
Mounting Flange: See model chart. conduit entrance. 36˝ (914.4 mm)
Aluminum, carbon steel, PVC, or long.
316 SS available. Conduit Connection: 1˝ NPT
Diaphragm: See model chart. female.
Viton®, Neoprene, Urethane, Buna- Process Connection: See model
N, Teflon®, Silicone rubber, or food chart. 2˝ flange, 3˝ flange, 4˝ flange,
grade available. 2˝ NPT, or suspended available.
MODELS Temperature Limits: 180°F Mounting Orientation: Flange
(82.2°C) suspended in liquid, 220°F mount, screw in, or suspend
Model Description (104.4°C) exterior tank mounted. depending on model.
Sliquid™ with 1 standard switch, 4˝ aluminum flange Pressure Limit: 75 psig (5.2 bar) Set Point Adjustment: Internal
L1FK20 (6-42˝ range), neoprene diaphragm, anodized aluminum Enclosure Rating: Weatherproof screw. Adjustable anywhere within
housing and submersible. the pressure range.
Repeatability: ±1 to 3% of full Weight: 6 lb (2.72 kg).
Sliquid™ with 2 standard switches, 4˝ aluminum flange Ranges: 6 to 42˝ w.c. (1.49 to
(6-42˝ & 6-42˝ ranges), neoprene diaphragm, anodized
range. Contact factory for specific
L2FA20 10.45 kPa), 12 to 120˝ w.c. (2.99 to
aluminum housing values.
Switch Type: SPDT snap switch or 29.9 kPa), and 100 to 200˝ w.c.
Sliquid™ with 2 standard switches, 4˝ aluminum flange SPDT gold contact snap switch. (24.9 to 49.8 kPa).
L2FB20 (6-42˝ & 12-120˝ ranges), neoprene diaphragm, anodized One to three switches available. Deadband: Approximately 20% of
aluminum housing Electrical Rating: Snap Switch: range. Contact factory for specific
15A @ 125/250/480 VAC. Gold values.
Sliquid™ with 2 standard switches, 4˝ 316SS flange Options: Suspension kits and dip
Contact Snap Switch: 1A @ 24
L2VB11 (6-42˝ & 12-120” ranges), Viton® diaphragm, White tube kits.
epoxy on anodized aluminum housing
VDC/125 VAC.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 247
pg248 7/29/05 9:34 AM Page 1

Series
CLT Continuous Level Transmitter
Customize To Fit Application, 316 SS or Buna-N Floats
FLOAT DIMENSIONS 2-1/16˝
1-7/8˝
1 1/4 [47.6] [52.4]
DIA. TYP. DIA. TYP.
[31.8]
DIA.
TYP.
1-13/16˝
Junction Box [46.0]
2-3/4˝
[69.8]
(Current Output 1-5/16˝
[33.3]
5/16˝
[7.9]
TYP. TYP.
Only) TYP.
4-9/16˝ 5/16˝ 5/16˝ [8]
[115.9] F1 F2 [8] F3

MOUNTING DIMENSIONS 6 HOLES Ø 3/4 [19.05]


2˝ NPT EQUALLY SPACED
ON A 6.000 B.C.
C [152.4]
1/2 NPT
HIGHEST
LEVEL
Level

INCHES Type 1 1/2 NPT Ø7-1/2


OF B 1-1/4 SQ [190.5]
INDICATION [31.75]
2 NPT

1/2 NPT
1/2 NPT Type 3 1
LOWEST
1.000 SQ [25.40]
LEVEL
[25.40]
1-1/4 NPT

Type 2 Type 4, 5

Continuous Output Level Transmitters provide up to the minute SPECIFICATIONS


tank level monitoring. Customize level transmitters to meet application Service: Compatible liquids.
Resolution: 1/4˝.
requirements. Transmitters can be configured for 4 to 20 mA or pro- Temperature Limits: Buna-N floats: 180°F (82°C) in water,
portional voltage output, stainless steel or Buna-N floats, and lengths -40 to 230°F (-40 to 110°C) in oil; SS stem: -40 to 230°F
(-40 to 110°C).
up to 72˝ (183 cm).
Pressure Limits: Buna-N floats: 150 psig (10 bar); SS floats: 300 psig
(21 bar).
Power Requirements: Proportional voltage output models:
10 to 30 VDC; 4-20 mA output models: 10 to 40 VDC.
Loop Resistance: 1.4 k1 maximum.
Models are built to your specifications. Electrical Connections: Proportional voltage output: 24˝ (61 cm) free
leads #22 AWG, PTFE jacketed; 4-20 mA output: Junction box.
Enclosure Rating: 4-20 mA models, NEMA 4 junction box.
Mounting Orientation: Vertical ±20°.
Example CLT V S 5 F3 20.25 02.00 23.50 CLT-VS5F3-20.25-02.00-23.50
Construction CLT Continuous Level Transmitter
Output V Voltage, proportional signal of 0 to supply voltage
C 4-20 mA
Stem and B Brass with Beryllium copper stops
Connection Material S 316 SS with SS ARMCO PH-15-7MO stops
1 1/2˝ NPT (Output Type V only)
2 1-1/4˝ NPT (Float F1 only)
Connection 3 2˝ NPT
Type 4 3˝ 150# Flange, Carbon Steel (Connection material S only)
{Max. pres. 150 psi (10.3 bar)}
5 3˝ 150# Flange, 316 SS (Connection material S only)
{Max. pres. 150 psi (10.3 bar)}
Material Min s.g. Max. Pres. psi (bar) Float Factor in (mm)
Float F1 Buna N 0.55 150 (10.3) 2.0 (50.8)
Type F2 Buna N 0.55 150 (10.3) 2.5 (63.5)
F3 316 SS 0.75 300 (20.7) 3.5 (52.4)
Indication 00.00 Length that the unit sends an output for level. Maximum is 68˝ (173 cm).
Length
Top Float Distance from bottom of mounting connection to upper float
Stop”C” 00.00 stop. Minimum is 1/4˝ (6.4 mm)
Dimension
Overall To calculate overall length, add Indication Length, Top Float
Length “B” 00.00 Stop Dimension “C”, and Float Factor. Maximum length is 72˝ (1.82 m)

248 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg249 7/29/05 9:34 AM Page 1

Model
CRF Continuous Level Transmitter
Loop-Powered, 4-20 mA Output, RF Admittance Technology
1/2 FEMALE NPT
CONDUIT CONNECTION
TYP 2 PLACES

3/4 MALE NPT


PROCESS CONNECTION
4-1/2
[114.3]

11/16 11/16
[17.46] [17.46]
"L" 4-1/2 2 [50.80] 3-7/16
1-3/8 [114.3]
[34.93] CLEARANCE [87.33]
FOR COVER
REMOVAL

Continuously monitor the level of liquids and slurries, without SPECIFICATIONS Electrical Connections: Screw
worry of false signals as a result of material build-up. Loop powered Service: Compatible liquids. terminal.
Series CRF delivers a 4-20 mA isolated output signal proportional to Wetted Materials: Conduit Connection: 1/2˝ female
NPT.
the height of material in a tank or holding vessel. Continuous level Connection: 316 SS.

Level
Probe: Teflon®. Process Connection: 3/4˝ male
transmitter can be field calibrated to fit your specific application. In- NPT standard. Optional 2, 3, or 4˝
tegral electronics and two-wire design simplify installation. Probes Accuracy: ± 0.1% of full range
repeatability, ± 0.3% of full range 150# flange in 316 SS or PVC, 1-
should be mounted vertically and are easily trimmed to shorter 1/2˝ or 2” sanitary clamp
linearity.
lengths where required. When mounting in nonmetallic or horizontal Temperature Limits: Probe: -40 to connection.
tanks, a separate grounding rod must be used. Consult factory re- 250°F (-40 to 121°C), Electronics: - Enclosure Rating: Weatherproof.
garding mounting flange, grounding rod assemblies, optional pressure 40 to 180°F (-23 to 82°C). Mounting Orientation: Vertically
rating, longer lengths and sanitary connection. Pressure Limit: 100 psig (6.89 mounted.
bar). Weight: 6 ft probe model is 7.25 lb
APPLlCATIONS Power Requirements: 18 to 30 (2.39 kg).
Alcohols, wastewater, oils, polymers, acids, caustics, pulp, slurries, VDC. Probe Length: Rigid Rod: 12˝
Output Signal: 4 to 20 mA, 2 wire. (304.8 mm) to 144˝ (3.66 m).
wood chips, water-based products in tanks, bins, or other vessels. Flexible cable with weight: 24˝
Zero and Span Adjustments:
Zero: 0 to 500 pF, Span: 25 to 2200 (609.6 mm) to 240˝ (6.096m).
pF. Options: Flange mount assemblies
MODELS with reference rod, flexible cable
Loop Resistance: 600 Ohms at 24
Model Number Probe Length VDC. probe, optional connections listed
Current Consumption: 0.6 VA. under process connection.
CRF-TR0-34T-072 Teflon® coated 316 SS 6 ft (1.83 m)
CRF-TR0-34T-096 Teflon® coated 316 SS 8 ft (2.44 m)

Series
PLT Piezoresistive Level Transmitter
2-wire, Loop-Powered, ±0.25% Accuracy
3-7/16
4-1/2 11/16 [87.33]
[114.30] [17.46] 11/16
2 [50.80] [17.46]
CLEARANCE
1/2 FEMALE FOR COVER
NPT CONDUIT REMOVAL
CONNECTION 4-1/2
TYP 2 PLACES [114.30]
7-1/2
[190.50]

2-1/2
[63.50]

FLANGE
MOUNT

Series PLT Piezoresistive Level Transmitters provide reliable mea- SPECIFICATIONS Electrical Connections: Screw termi-
surement and control of process levels by sensing the hydrostatic pressure Service: Compatible liquids. nal.
in a tank. The loop-powered level transmitter delivers a 4 to 20 mA output sig- Wetted Materials: 316 SS and Teflon®. Conduit Connection: 1/2˝ female NPT.
nal proportional to hydrostatic pressure and specific gravity of the fluid for Accuracy: ± 0.25% of span. Process Connection: 2 or 3˝ 150#
indicating, recording or control purposes. Easily accessible zero and span Repeatability and hysteresis: ± 0.10% of flange, 3˝ 300# flange. 1/4˝, 1/2˝, or 3/4˝
full range. female NPT.
potentiometers make calibration in the field quick and simple. Units are Enclosure Rating: Weatherproof.
equipped with EMI and reverse polarity protection. Temperature Limits: 0 to 200°F
(-18 to 93°C). Mounting Orientation: Any position.
APPLICATIONS Compensated Temperature Range: Weight: NPT Connection: 7.95 lb (3.61
Monitor and control levels of water, chemicals, lubricants, or paints in vented 0 to 180°F (-18 to 82°C). kg), 2˝ flange connection: 11.85 lb (5.38
tanks. Ideal for fluids with suspended solids such as wastewater and slurries. Pressure Limit: 3 times the full range. kg).
Power Requirements: 18 to 30 VDC. Fill Solution: Silicone oil.
MODELS Output Signal: 4 to 20 mA, 2 wire. Vibration Limits: ±1 g, 10 to 200 Hz.
Zero and Span Adjustments: Zero Options: See process connection for
MODEL NUMBER RANGE MOUNTING other connection options. 10 psi (.69
adjustment for elevation compensation:
PLT1040 1 psig (0.07 bar) 2 ft (.61 m) 1" female NPT 25%. bar) up to 500 psi (34.47 bar) ranges.
PLT1050 1 psig (0.07 bar) 2 ft (.61 m) 2" Flange Loop Resistance: 1000 Ohms at 24
PLT2040 5 psig (0.34 bar) 10 ft (3.05 m) 1" female NPT VDC.
PLT2050 5 psig (0.34 bar) 10 ft (3.05 m) 2" Flange

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 249
pg250 8/8/05 3:16 PM Page 1

Series
UT Ultrasonic Level Transmitter
Noncontact Measurement, ±0.25% Accuracy, 4-wire
3.750 4.826
[95.25] 5.118 [122.58]
[129.99] 1.811
5.00 [46.00]
[127.00]
6.500
[165.10] 3/4⬙ FEMALE NPT 5.118
[129.99]
.688
3.750 [17.48]
[95.25]
6.080
10.00 3/4⬙ MALE NPT [154.43] 3/4" MALE NPT
[254] 4.000
UT125 UT1264
[101.6]
Ø.875 [22.23] (Ø0.875)
[22.23]

Series UT Ultrasonic Level Transmitters provide reliable, non- SPECIFICATIONS Beam Angle: Conicle 12°.
contact measurement for liquid level control in tanks and other vessels. Range: 10 ft (3 m). Power Requirements: 16 to 30
Level

Integral electronics generate an ultrasonic pulse which is transmitted Service: Liquids. VDC.
through the air space in the tank. The pulse is reflected back to the sen- Wetted Material: UT125: CPVC; Output Signal: 4 to 20 mA DC
sor at the liquid/air interface. From the received echo, the time of flight UT1264: Kynar®. (isolated), 4-wire.
can be calculated which is directly proportional to the distance of the liq- Accuracy: ±0.25% full scale. Zero and Span Adjustments:
Repeatability: 1/8” (3.2 mm) typi- Zero: 6˝ to 114˝ (15 to 290 cm),
uid surface to the sensor. A continuous 4 to 20 mA output signal is gen- Span: 1˝ to 120˝ (2.5 to 305 cm).
erated and updated every half second. Units feature a fully adjustable cal.
Temperature Limits: Sensor: Process Connection: 3/4˝ male
zero and span, height and distance mode adjustment, lost echo LED indi- NPT.
cation, and reverse polarity protection. –20 to 160°F (–29 to 71°C),
Electronics: –10 to 170°F (–23 to Enclosure Rating: UT125: NEMA
77°C) compensated over full range 7, cast aluminum; UT1264: NEMA
of sensor. 4X (IP67), ABS plastic.
Model UT125 Ultrasonic Level Transmitter, CPVC Pressure Limits: 100 psig (6.9 Mounting Orientation: Vertical.
Model UT1264 Ultrasonic Level Transmitter, Kynar® bar). Weight: UT125: 5 lb (2.3 kg);
Blind Zone: 6˝ (15 cm). UT1264: 2.0 lb (0.91 kg).

Series
SLT Submersible Level Transmitter
316 SS Construction, ±0.25% Accuracy, Easy to Install

7.000 [178]
6.090 [155]

Ø 1.250
[31.8]
.875 12408600
TYP.
[22.2]

Series SLT Submersible Level Transmitter is designed to provide SPECIFICATIONS Thermal Effects: Max ±1% URL
accurate and reliable liquid level measurement in tanks, wells, ponds, flood Service: Liquids. output change for ±25°C temp.
channels, or landfills. The fully submersible transmitter and cable are easy Wetted Materials: 316 SS, Viton® change within compensated range
O-ring, HDPE cable jacket. when calibrated @ 25°C.
to install—simply lower the unit to the appropriate depth for measurement.
Accuracy: ±0.25% FS, BFSL Power Requirements: 12 to 24
The transmitter measures hydrostatic pressure and transmits a 4 to 20
(includes linearity, hysteresis, and VDC.
mA output signal proportional to the liquid level. The Series SLT is con- Output Signal: 4 to 20 mA DC
structed of 316 SS and includes a removable, non-clogging snubnose end repeatability); ±0.50% FS for model
SLT6 only. limited to 30 mA DC.
to protect the sensing element. Units are reverse polarity and surge pro- Zero and Span Adjustments:
Temperature Limits: –25 to
tected. 140°F (–32 to 60°C). ±0.50% FS set @ 77°F (25°C).
Pressure Limits and Overrange Loop Resistance: 8001 max @
MODELS Effect: ±0.15% FS @ 300% of 28V.
maximum range. Electrical Connection: Attached
Model Cable
Range Compensated Temperature 4-wire, 20 AWG polyethylene
Number Length
Range: 23 to 130°F (-5 to 55°C). shielded cable.
SLT6 0 to 6 psi (0 to 13.8 ft H O) 2 50 ft (15 m) Weight: 1.0 lb (454 g).
SLT15 0 to 15 psi (0 to 34.6 ft H O) 2 75 ft (23 m) Agency Approvals: CE.

250 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg251 7/29/05 9:33 AM Page 1

Series
SBLT Submersible Level Transmitter
Perfect for Ground Water and Wells, Lightning Protected
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Body: 316 SS, Cable: Polyurethane. Bullet Nose: PVC.
Accuracy: ±0.20% of full scale.
Temperature Limits: -40 to 150°F (-40 to 65.6°C).
Compensated Temperature Range: 0 to 140°F (-17.8 to 60°C).
Pressure Limit: 1.5X full scale range.
Thermal Effect: Less than ±2.0% of full scale per 100°F.
.750 Power Requirement: 9 to 36 VDC.
[19.05] Output Signal: 4 to 20 mA DC, 2-wire.
5.800 Response Time: < 5 ms.
[147.32] Loop Resistance: 750 ohms at 24 VDC
Electrical Connections: Wire pigtail.
Mounting Orientation: Suspended in tank below level being measured.
Can be placed on the bottom of the tank on its side.
Standard Features: Calibration certificate.
Weight: 3.5 lb (1.59 kg).
SBLT Submersible Level Transmitter is manufactured for years of trouble Electrical Protection: Dual transient lightning and surge arrestors exceed-
free service. The transmitter consists of a bonded foil, strain gauge, sensing el- ing FM approved I/S and meet EMA/RFI standards Mil-Std 461/462 and

Level
ement, encased in 316 SS housing. Superior lightning and surge protection uti- ground to transducer case.
lizing dual arrestor technology, grounded to case, eliminating both power supply
surges and lightning ground strike transients. Bullet nose design protects di-
aphragm from damage. Comes equipped with a 220-pound tensile strength, MODELS
shielded, vented, Polyurethane cable. Ventilation tube in the cable automatical-
ly compensates for changes in atmospheric pressure above the tank. The vent is Model Number Pressure Range Cable Length
protected with a filter eliminating moisture collection in the transducer. SBLT-5-40 5 psi (.35 bar) 40 feet (12.2 m)
APPLICATIONS
SBLT-10-40 10 psi (.69 bar) 40 feet (12.2 m)
• Well monitoring; Ground water monitoring; Environmental remediation; Sur- SBLT-15-60 15 psi (1.03 bar) 60 feet (18.3 m)
face water monitoring; Down hole; Water Tanks SBLT-20-60 20 psi (1.39 bar) 60 feet (18.3 m)
Extended cable length available contact the factory.

Series
SPT Submersible Pressure Transmitter
Stainless Steel Housing, Fully Submersible, 4-20 mA or 0-5 VDC Output
INTERGRAL PRESSURE
PORT G 1/8

3-41/64
3/4 HEX (92) MAX ABSOLUTE 2-29/64
(19) 3-3/16 (62)
(81) MAX GAUGE
1-5/64
(27) 4-25/64
(112) MAX ABSOLUTE
3-61/64
(100) MAX GAUGE

The Series SPT Submersible Pressure Transducer features stabil- SPECIFICATIONS


ity and accuracy for the most demanding submersible and industrial ap- Service: Compatible liquids.
plications. Units include a plastic nose cone to protect the sensing element. Wetted Materials: 17-4 PH SS and ABS Plastic.
The rugged stainless steel construction and the 81 foot (24.6 m) cable add Accuracy: ±0.25% FS.
an element of durability and versatility to this transducer. Units include Stability: ±0.2 % of F.S. for 1-year (non-cumulative).
circuitry for protection against noise, voltage spikes, and static discharge. Temperature Limits: -5 to 180°F (-20 to 82°C).
The submersible transmitter is a excellent choice for ground water moni-
Pressure Limits: ±2% of FS.
toring, reservoirs, waste water, well monitoring, flood channels and land-
fills. Thermal Effect: 1.5% FS.
Power Requirements: 24 VAC.
Output: 4-20 mA DC or 0-5 VDC 2-wire.
MODELS Loop Resistance: 850 ohms @24 VDC.
Electrical Connection: Moulded immersible cable.
Model Range Output
Process Interface: Plastic nose cone.
SPT-101381 0-15 psi 0-5V Enclosure: 316 SS, 17-4 PH SS.
SPT-401381 0-15 psi 4-20 mA Weight: 1lb (100 g).

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 251
pg252 7/29/05 9:32 AM Page 1

Series
PBLT Submersible Level Transmitter
Perfect for Sludge and Slurries, Lightning Protected
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: 316 SS and 15-5 SS, Cable: Tefzel®.
BREATHER TUBE Accuracy: ±0.25% of full scale.
Temperature Limits: -20 to 190°F (-28.9 to 87.8°C).
STRAIN
RELIEF
Compensated Temperature Range: 0 to 180°F (-17.8 to 82.2°C).
3-7/16 Pressure Limit: 2X full scale range.
[87.31] Thermal Effect: Less than ±2.0% of full scale per 100°F.
1-1/2 Power Requirement: 9 to 36 VDC.
[38.10] 1/2 NPT SUBMERSIBLE Output Signal: 4 to 20 mA DC, 2-wire.
2-5/16 CABLE
[58.74] 8-1/2
Response Time: < 5 ms.
[215.90] Loop Resistance: 750 ohms at 24 VDC.
Electrical Connections: Wire pigtail.
Enclosure Rating: Intrinsically safe with proper barrier.
Mounting Orientation: Suspended in tank below level being measured.
PBLT Submersible Level Transmitter is manufactured for years of trouble Can be placed on the bottom of the tank on its side.
free service in the harshest applications. The PBLT measures the height of liq- Weight: 8.8 lb (4.0 kg).
uid above it’s position in the tank referenced to atmospheric pressure. The Standard Features: Calibration certificate.
transmitter consists of a bonded foil, strain gauge, sensing element, encased in Electrical Protection: Dual transient lightning and surge arrestors exceed-
a 316 SS housing. Perfect for wastewater and slurry applications with features ing FM approved I/S and meet EMI/RFI standards Mil-STD 461/462 and
to protect the unit from these demanding applications. Superior lightning and
Level

ground to transducer case.


surge protection utilizing dual arrestor technology, grounded to case, eliminat-
ing both power supply surges and lightning ground strike transients. Large di- MODELS
ameter 316 SS diaphragm seal is non-clogging and damage resistant to floating
solids. Model Number Pressure Range Cable Length
PBLT-5-40 5 psi (.35 bar) 40 feet (12.2 m)
Comes equipped with a 220-pound tensile strength, shielded, vented, Tefzel PBLT-10-40 10 psi (.69 bar) 40 feet (12.2 m)
cable. Ventilation tube in the cable automatically compensates for changes in at-
mospheric pressure above the tank. The vent is protected with a filter elimi- PBLT-15-60 15 psi (1.03 bar) 60 feet (18.3 m)
nating moisture collection in the transducer. PBLT-20-60 20 psi (1.39 bar) 60 feet (18.3 m)

APPLICATIONS Extended cable length available contact the factory.


• Wastewater: sludge pits, clarifiers, digesters; Alum tanks; Chemical storage
tanks; Oil tanks; Lime slurry; Sumps; Reservoirs

Series
A-900
&
1/4 DIN Control Enclosures
A-901 Weatherproof, Durable, Pre-Cut Mounting Hole ®

4-1/4
[107.95]
3-39/64 10-32 UNF-28
[91.68] TYP 8 PLCS
1-1/2 1-3/4
[38.10] [44.45]
3-39/64 4-1/4 5-1/64
7-11/16 4-11/64
[91.68] [107.95] [127.40]
[195.26] [105.97]
A-901 UNIT
(4-1/2 [114.30] STANDOFFS)
5-1/64 4 PLCS
7-11/16
[127.40]
[195.26]
A-900 A-901 TOP VIEW BOTTOM VIEW SIDE VIEW
Models A-900 and A-901 are the perfect instrument housings for indoor or SPECIFICATIONS
outdoor applications. Protects controls from dirt, dust, oil and water. Unit is Service: Indoor or outdoor.
rated weatherproof type NEMA 4X and has a fully gasketed cover. Standard Rating: NEMA 1, 2, 3, 3R, 4, 4X, 12 and 13.
features include a lockable latch to prevent tampering and flush mounting hard- Materials: Body: UV stabilized fiberglass reinforced polyester;
ware. Includes feet and screws for flush mounting to a wall. Snap Latch: 304 SS; Hinge: Stainless Steel; Mounting Feet and Screws: 304 SS;
Window: UV stabilized polycarbonate; Cover Gasket: Neoprene.
The Model A-900 comes standard with a 1/4 DIN cut out in the front cover.
Agency Approvals: UL 508.
Controller will mount with front face exposed for easy access to the program-
ming buttons. Love and Mercoid controllers feature weatherproof NEMA 4X Control Temperature Limits:
rated front panels and gaskets enabling the control to be weatherproof pro- When using the enclosures with controls that have 10A relay outputs the extra heat
tected when installed in the A-900 even though the front face is exposed. generation decreases the maximum ambient temperature value that the control can be
Wiring an installed control is easy due to the hinged cover and spacious clear- used at inside the enclosure. Other outputs on our controls are not a concern.
ance for the control to swing out with front cover. The lockable latch prevents
unauthorized removal of the control from the enclosure. MODELS
The Model A-901 comes standard with a clear plastic front window and mount- Model Description
ing hardware to install the control inside the box. Controller mounts just Number
behind the window assuring easy viewing.
A-900 Weatherproof enclosure, Type 4X. Control
For Models: 25XX3, 26XX3, 26X3X, 26X33, MPC direct panel mounts in the front of the
Ambient Maximum Current enclosure.
Temperature A-900 A-901
77°F (25°C) 10 Amps A-901 Weatherproof enclosure, Type 4X. Clear
10 Amps
104°F (40°C) 10 Amps 9 Amps plastic window with rear panel for mounting
131°F (55°C) 7.5 Amps 6 Amps the control inside the enclosure.

252 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg253 7/29/05 9:32 AM Page 1

Series
MPC Pump Controller
One or Two Pump Control with Built-In Alternation, Over Temperature
Protection and Seal Failure Monitoring
4.500 3.774
(114.3) (95.9)
0.530
(13.5)

NEW
Features! 3.774
3.596 (95.9)
(91.3 mm)

Panel cut-out: 3.620 x 3.620 in, +0.032/-0.000 Panel Thickness Meets IP66 (UL Type 4X)
(92 x 92 mm, +0.8/-0.0). 0.250 (6.53 mm) Max.

Level
Allow for 0.5 in (13 mm) clearance
at the rear of the instrument.

The Mercoid MPC Pump Controller provides versatile level SPECIFICATIONS


control in a standard 1/4 DIN package. Designed for use with Inputs: 4 (or 0) to 20 mA DC or 2 (or 0) to 10 VDC selectable.
almost any style level transmitter the unit displays the present Input Impedance: Current = 10 ohms, Voltage = 100 K ohms.
level and main set point value. Incorporated in the MPC is pro- Output Ratings:
Control Relays: SPDT, rated 10A @ 240 VAC res.,
grammable level differential for on/off control of one or two 1/4 hp @ 120 VAC, 1/3 hp @ 240 VAC.
pumps, valves, or other devices through two SPDT relays. Also fea- Alarm Relays: SPST, 3A @ 240 VAC res., 1/10 hp
tured are two additional programmable alarm contacts with front @ 120 VAC.
alarm light indication. Control Type: On/off, reverse (pump out) or direct (pump in) act-
The MPC is flexible and incorporates a user-friendly programming ing.
menu. The front face meets NEMA 4X for outdoor panel mounting. Power Requirements: 100 to 240 VAC nominal, +10%-15%,
50 to 400 Hz, single phase; 132 to 240 VDC nominal, +10%-
So many features are combined into the MPC that it eliminates 15%.
many components in a pump control system. Power Consumption: 7.5 VA maximum.
Accuracy: ±0.25% of span, ±1 least significant digit.
NEW FEATURES Display: Two 4 digit, 7 segment 0.56˝ high LED’s.
• Alarms can be programmed for output indication of pump seal Display Resolution: 1 count.
failure or over temperature. Memory Backup: Nonvolatile memory (no batteries required).
• Selectable time delay, for pump two, on power up to prevent Serial Communications: Optional RS-232 or RS-485 with
both pumps from starting at the same time. If power is lost, Modbus® protocol.
Ambient Operating Temperature/RH: 14 to 131°F (-10 to
upon regaining power a time delay of up to 60 seconds can be 55°C)/0 to 90% up to 104°F (40°C) non-condensing, 10 to 50%
selected to prevent too large of a current draw. at 131°F (55°C) non-condensing.
Weight: 16 oz. (454 g).
FEATURES Front Panel Rating: Meets UL Type 4X (IP66).
• Selectable pump alternation when used with two pumps to Loop Power Supply (isolated): 24 VDC @ 50 mA, regulated.
minimize pump wear. With alternation “on” a seal failure or Seal Failure (Moisture Sensor):
over temperature condition will force the non-failed pump to Power: 2.5 VDC.
lead status and stop alternation. Search Current: 3 micro amps.
Resolution: 10K to 500K ohms in 10K ohm steps.
• When used with a submersible pump including a moisture Agency Approvals: UL 508, CE.
sensor the MPC has alarm light indication of seal failure.
• When used with a pump including a thermostat the MPC
ACCESSORIES:
has alarm light indication of pump over temperature and
Weatherproof Enclosures, NEMA 4X.
removes the pump from service. The Pump can be brought
See page 252 for details.
back into service automatically or by manual reset when the
pump has cooled down.
For compatible level transmitters see A-901
• Integral 24 VDC power supply for level transmitter.
Mercoid Series SBLT and PBLT.
• Displays pump run time from a front panel button.
• Test System function that simulates the process input to
insure the pumps are operating or to test programming. Series MPC Pump Controller
• User selectable security lock-out of programming and/or set
points. OPTIONS
• Process input retransmission as a current (4 to 20 mA) RS-232 Modbus®-RTU Serial Communications.
or voltage (2 to 10 VDC) analog signal*. Add suffix – 232
RS-485 Modbus®-RTU Serial Communications.
Add suffix – 485
* Standard model MPC is set for current retransmission.
For voltage retransmission add suffix “-RV”. Modbus® is a registered trademark of Schnieder Automation.

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 253
pg254 7/29/05 9:30 AM Page 1

Series
PCP Relay/Controller/Power Supply
10A SPDT Relay, 24 VDC Power Supply, Latching Circuit for Level Control

5-49/64
[146.45]
5-1/4
[133.35]

4-23/32 3-1/2
[19.85] [89.00]

3/16 DIA. TYP


4-39/64 [4.75]
[119.23]
1-13/32 TYP [35.72]
Level

1-3/16
[30.16] 2-11/32
[59.53]
5/8 DIA. X THRU
2 PLCS [15.88]

APPLICATIONS SPECIFICATIONS
• Use with two point level switches for an adjustable Inputs: One or two normally open switches.
differential controlling a pump. Output Type: SPDT switch.
• Use as an external higher current relay for reed or Output Rating: See model chart.
NPN switches. Control Type: On/off with manual reset capability.
• Use as a power supply for NPN switches or transmitters. Power Requirements: 24 VDC, 24 VAC, 120 VAC, or 240 VAC.
Power Consumption: DC power: 15 mA maximum, AC power: 55
FEATURES mA maximum.
• Field selectable power requirements of 24 VDC, 24 VAC, Ambient Operating Temperature: 0 to 140°F (-18 to 60°C).
120 VAC, or 240 VAC. Weight: 1.06 lb (0.48 kg).
• Compact size with flange for surface mounting. Enclosure Rating: General purpose.
• Manual reset capability. Loop Power Supply: 5 or 24 VDC regulated. 200 mA maximum.
Mounting Orientation: Horizontal or vertical.
The Series PCP level controller is designed to be a power
supply, an external relay, and a latching relay for differential
level control with two level switches. As a power supply the PCP
can step down line voltage to 5 or 24 VDC to power NPN switch-
es such as the OLS and PC level switches or to power a trans- Pump Out Control with F7 Level Switches
mitter. The PCP can function as an external relay to increase and PCP Controller
switching capability by providing up to a 10A SPDT contact for
direct control of moderate loads. As a latching relay the PCP can
be used with any two normally open level switches and provide
level control for pumps. The latching circuit can also be used to
hold the relay in an actuated state until manually reset.
PCP F7

MODELS
Model Electrical Rating of Contact
Number 120 VAC 30 VDC Max. Switching Capacity
PCP-1 0.5A 1A 62.5 VA, 33 W
Pump
PCP-5 5A 5A 600 VA, 150 W F7
PCP-10 10A 5A 1250 VA, 150 W

Drain

254 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg255 7/29/05 9:30 AM Page 1

Series
MVR Mini View-Rite Level Indicator
Customized, Visual Level Indication, Compact Size

TOP & BOTTOM SIDE & SIDE

L1
L1 & C to
C to C

Level
TYPICAL MEASUREMENTS
C to C = L1 + 7.72˝ (196.09 mm) C to C = L1

Miniature custom level indicators are ideal for high-visibility level SPECIFICATIONS
indication in tight spaces. All stainless steel housing provides rugged Service: Clean, low-viscosity liquids.
durability with a diameter of only 1-1/4 inches (32 mm). Select the Pressure Limits: ) 300°F, 400 psi (27.6 bar); * 300°F, 373 psi (25.7
mounting type that will best fit your application and an indication
length of up to 96 inches (244 cm). View-Rite level indicators incorpo- bar).
rate a pressure tight housing with internal float that magnetically acti- Tube Diameter: 1-1/4˝ (32 mm).
vates external level indication flags, switches, or transmitter. SWITCH MODULES
Clamp onto the level indicator. SPST, rated .17A @ 120 VAC, .08A @
240 VAC, .13A @ 120 VDC, .06A @ 240 VDC.
MVR-S1, Maximum temperature is 300°F (148.9°C).
Polysulfone with 1/4˝ female NPT conduit connection.
MVR-S2, Maximum temperature is 750°F (399°C). 316 SS
Models are built to your specifications with 1/2˝ male NPT conduit connection.
MVR-S3, Maximum temperature is 750°F (399°C). Explosion-
proof terminal box with 1/2˝ female NPT conduit connection.

Example MVR S SS 1 TP D 0.8 150 090 80 P 1 I MVR-SSS1-TPD-0.8-150-090-80P1-I


Construction MVR Mini View-Rite Level Indicator
WETTED Materials S 304 L SS Housing, 316 L SS Float, Viton® O-ring
TB Top/Bottom Connections
Configuration
SS Side/Side Connections
Process 1 1/2˝ NPT (Female on TB, and Male on SS Configuration)
Connection 3 1/2˝ 150# RF Flange
TP Top
Float
BM Bottom
Access
TB Top and Bottom (Only with SS Configuration)
N None
Drain Drain, 1/2˝ female NPT (Only with SS Configuration)
D
and
V Vent, 1/2˝ female NPT (Only with SS Configuration)
Vent
B Drain and Vent (Only with SS Configuration)
Spec. Gravity 0.0 Specific Gravity of fluid, minimum 0.8
Operating Operating Pressure, in psi. Maximum is 400 psi (27.6 bar)
000
Pressure
Operating Operating Temperature of the fluid, in °F. Maximum is 400°F (20°C)
000
Temperature
Indicating 00 Length of level indicator, in whole inches. Maximum of 96˝ (2.44m)
Length, L1
Indicating P Plastic, white and orange [300°F (149°C) maximum]
Flags A Aluminum, silver and black
Visual N None
Indicating 1 Feet and Inches
Scale 2 Inches Only
Output I 4 to 20 mA transmitter of level [300°F (149°C) maximum]
Options V 0 to 5 VDC transmitter of level

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 255
pg256 7/29/05 9:30 AM Page 1

Series
VR View-Rite Level Indicator
Customized to Fit Any Application, Durable, 316 SS Housing and Float

L1
C to C L1 & C to C

TOP & BOTTOM SIDE & SIDE


Level

TYPICAL MEASUREMENTS
C to C = L1 + 10.25˝ (260.35 mm) C to C = L1

Customize level indicators to meet application require- SPECIFICATIONS


ments. Visi-rite level indicators are low maintenance, environ- Service: Clean, low-viscosity liquids.
mentally friendly, durable, and require no external power. Pressure Limits: 275 psi (18.9 bar), 225 psi (15.5 bar) @ 100°F (37.8°C),
Specify any indication length up to 96 inches (244 cm). View- 215 psi (14.8 bar) @ 300°F (148.9°C),
Rite level indicators incorporate a pressure tight housing with 195 psi (13.4 bar) @ 400°F (204.4°C).
internal float that magnetically activates external level indica- Tube Diameter: 2-1/2˝ (64 mm).
tion flags, switches, or transmitter.
OPTIONAL SWITCH MODULES
Clamp onto the level indicator. SPST, rated .17A @ 120 VAC, .08A @ 240
Models are built to your specifications VAC, .13A @ 120 VDC, .06A @ 240 VDC.
VR-S1, Maximum temperature is 300°F (148.9°C).
Polysulfone with 1/4˝ female NPT conduit connection
VR-S2, Maximum temperature is 750°F (399°C). 316 SS
with 1/2˝ male NPT conduit connection.
VR-S3, Maximum temperature is 750°F (399°C).
Explosion-proof terminal box with 1/2˝ female NPT
conduit connection.

Example VR S SS 1 TP D 0.8 150 090 80 P 1 I VR-SSS1-TPD-0.8-150-090-80P1-I


Construction VR View-Rite Level Indicator
WETTED Materials S 316 L SS, Viton® O-ring
Configuration TB Top/Bottom Connections
SS Side/Side Connections
1 1/2˝ NPT (Female on TB, and Male on SS Configuration)
Process 2 1˝ NPT (Female on TB, and Male on SS Configuration)
Connection 4 1˝ 150# RF Flange
5 2˝ 150# RF Flange
TP Top
Float Access BM Bottom
TB Top and Bottom (Only with SS Configuration)
N None
Drain D Drain, 1/2˝ female NPT (Only with SS Configuration)
and Vent V Vent, 1/2˝ female NPT (Only with SS Configuration)
B Drain and Vent (Only with SS Configuration)
Spec. Gravity 0.0 Specific Gravity of fluid, minimum 0.8
Operating Pressure 000 Operating Pressure, in psi. Maximum is 275 psi (18.9 bar)
Operating Temp. 000 Operating Temperature of the fluid, in °F. Maximum is 400°F (20°C)
Indicating Length, L1 00 Length of level indicator, in whole inches. Maximum of 96˝ (2.44 m)
P Plastic, white and orange [300°F (149°C) maximum]
Indicating Flags
A Aluminum, silver and black
Visual N None
Indicating 1 Feet and Inches
Scale 2 Inches Only
I 4 to 20 mA transmitter of level [300°F (149°) maximum]
Output Options
V 0 to 5 VDC transmitter of level

256 VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au


pg257 level 7/29/05 9:28 AM Page 1

Series
TLI Tank Level Indicator
Double Wall Construction for Ultra-Pure or Corrosive Liquids
9 TLI-0
[228.60]
15 TLI-1
[381.00]
27 TLI-2
1-1/2 [685.80]
[38.10] 39 TLI-3
[990.60]
51 TLI-4
[1295.40]

The Series TLI Tank Level Indicator provides a visual indica- SPECIFICATIONS
tion of the height of liquid contained in a tank. The 1/2-foot unit can Service: Compatible gases and liquids.
Wetted Materials: Tube: Borosilicate glass. End Connections: PVC,
also be used as a sight flow tube when mounting in a pipeline. The Polypropylene, or Teflon® (PTFE). O-ring: Viton®.

Level
TLI series utilizes a double wall construction to indicate the level Temperature Limit: PVC end connections: 140°F (60°C), Polypropylene
of corrosive or ultra-pure liquids and is available with PVC, end connections: 185°F (85°C), Teflon® end connections: 210°F (100°C).
Pressure Limit: 100 psig (6.9 bar) at 180°F (82°C).
Polypropylene, or Teflon® fittings and 1/2˝ or 3/4˝ NPT threads. Connections: 1/2˝ female NPT standard. Change 1 in model number to 2
Viton® seals are standard. All units are hydrostatically tested to for 3/4˝.
400 psi (27.6 bar). Enclosure: Exterior acrylic shield tube to protect glass tube.

MODELS
OPTIONS
Model Number Glass Tube Length -AT Aluminum Tag
TLI-0-1 6 in. (152.4 mm) -P Polypropylene Fittings
TLI-2-1 24 in. (609.6 mm) -T Teflon® Fittings
TLI-3-1 36 in. (91.4 cm) Note: For 3/4˝ NPT fittings, change the last digit of the model number to 2.
TLI-4-1 48 in. (121.9 cm)

Series
PS Proximity Sensors
Capacitive or Inductive 3-Wire DC, Threaded Body
Dim. PSC20103 PSC20203 PSI2002203 PSI2005303
A M18 M30 M12 M18
PSC Series B 1.065 (27) 1.614 (41) 0.688 (17) 0.938 (17)
C 0.157 (4) 0.197 (5) 0.125 (3) 0.125 (3)
D 3.156 (80) 3.156 (80) 2.36 (60) 2.87 (73)
E 2.36 (60) 2.36 (60) 1.58 (40) 1.97 (50)

PSI Series

The Series PS Proximity Sensors are noninvasive sensors ideal SPECIFICATIONS


for level detection, position indicating and counting applications. Ca- Wetted Materials: Glass reinforced plastic (PSC), Stainless Steel
pacitive type sensors detect electrically conducting and nonconducting (Model PSI2002203), Nickel-plated Brass (Model PSI2005303).
materials, liquids, solids, or powders and include a sensitivity adjust- Temperature Limits: -22 to 212°F (-30 to 100°C) capacitive, -13 to 158°F
ment to differentiate between various materials. Inductive sensors de- (-25 to 70°C) inductive.
tect ferrous or nonferrous metals only. A bright LED indicates the Enclosure Rating: PSC, IP65; PSI, IP68.
state of the output switch. Sensors feature short circuit, reverse po- Repeatability: ±0.05% (Model PSC20103), ±0.1% (Model PSC20203 ±0.01%
larity, and transient protection. Small size and threaded body make in- (PSI Models).
stallation easy. Inductive sensors are embeddable (can be mounted
Power Requirements: 8 to 30 VDC.
flush). Capacitive sensors are environmentally protected to IP65 and
Switch Type: Normally open NPN transistor, sinking.
Inductive sensors are protected to IP68. Units include two fixing,
screwdriver, and operating manual. Electrical Rating: 250 mA (PSC), 200 mA (PSI).
Minimum Load Current: 8 mA (PSC), <25 mA (PSI).
MODELS Leakage (Off-State) Current: <3 mA (PSC), <0.08 mA (PSI).
Model Body Switching Detecting Voltage Drop: <3.5V @ 250 mA (PSC).<2.5V @ 200 mA (PSI).
Number Type Size Frequency Dist. in (mm) Ripple: 10%.
PSC20103 Cap. M18 400 Hz .04-3 (1-10) Electrical Connection: 9.8 ft (3 m) cable.
PSC20203 Cap. M30 250 Hz .08-79 (2-20)
PSC30203* Cap. M30 Deadband: 20% of range (PSC), 15% of range (PSI).
250 Hz .08-79 (2-20)
PSI2002203 Ind. M12 800 Hz .08 (2) Initializing Time Delay: <10 msec.
PSI2005303 Ind. M18 500 Hz .19 (5) Agency Approvals: CE.
*NPN Transister

CALL TO ORDER: U.S. Phone 219 879-8000 • U.K. Phone (+44) (0)1494-461707 • Asia Pacific Phone 61 2 4272-2055 257