1

Konica-Minolta bizhub 500 Error Codes List page 1 (from 11 )

Code Description Causes


Drive Paper lift motor /1 (M7)
C- - The upper limit sensor /1 (PS6) does not turn ON within a Upper limit sensor /1
0201 specified period of time after the paper lift motor /1 (M7) turns (PS6) Printer control
ON.PRT: P board (PRCB)
Drive Paper lift motor /2 (M8)
C- - The upper limit sensor /2 (PS13) does not turn ON within a Upper limit sensor /2
0202 specified period of time after the paper lift motor /2 (M8) turns (PS13) Printer control
ON. board (PRCB)
Drive Paper lift motor /3
C- - The upper limit sensor /3 (PS114) does not turn ON within a (M124) Upper limit
0203 specified period of time after the paper lift motor /3 (M124) sensor /3 (PS114) PC
turns ON.r control board (PCCB)
Drive Paper lift motor /4
C- - The upper limit sensor /4 (PS123) does not turn ON within a (M125) Upper limit
0204 specified period of time after the paper lift motor /4 (M125) sensor /4 (PS123) PC
turns ON.r control board (PCCB)
Drive Paper lift motor (M151)
C- - The upper limit sensor (PS152) does not turn ON within a Upper limit sensor
0205 specified period of time after the paper lift motor (M151) turns (PS152) LU drive board
ON. (LTDB)
Paper lift motor (M5)
Drive
C- Shift motor (M4) Shift
- Paper lift motor (M5) abnormality. Shift motor (M4)
0206 gate motor (M3) PC
abnormality. Shift gate motor (M3) abnormality.
control board (PCCB)
Drive
- While in the paper feed, there occurs a condition twice in
succession in which the lift sensor (PS23) does not turn ON Pick-up solenoid /BP
C- within a specified period of time after the pick-up solenoid /BP (SD1) Lift sensor (PS23)
0207 (SD1) turns ON. While in the power switch (SW2) ON, there Feed motor (M9) Printer
occurs a condition twice in succession in which PS23 does control board (PRCB)
not turn OFF within a specified period of time after SD1 turns
ON.
Conveyance suction fan
C- Fan abnormality
(FM5) Printer control
0301 - Conveyance suction fan (FM5) abnormality.
board (PRCB)
C-
1001
Communication abnormality
- Communication abnormality between the engine control of Overall control board
the overall control board (OACB) and that of the printer (OACB) Printer control
control board (PRCB). While in the stand-by, an FS Ready board (PRCB)
signal cannot be detected for a specified period of time.
2

FS
C- FS control board
- FS communication abnormality. A serial communication is
1002 (FSCB) Printer control
unavailable between the FS control board (FSCB) and the
board (PRCB)
printer control board (PRCB).
FS-510
C- FS control board
- Flash ROM abnormality. A checksum error of the flash ROM
1003 (FSCB)
is detected.
FS-511 Shift motor (M8) drive abnormality.
- When starting the home position movement, the shift home
Shift motor (M8) Shift
C- sensor (PS10) does not turn ON a specified period of time
home sensor (PS10) FS
1101 after M8 turns ON.
control board (FSCB)
- When starting the shift position movement, PS10 does not
turn OFF a specified period of time after M8 turns ON.
FS-511:Tray lift motor (M7) drive abnormality.
- While in the main tray up drive, the main tray upper limit
sensor (PS19) does not turn ON within a specified period of Tray lift motor (M7) Main
C- time after M7 turns ON. tray upper limit sensor
1102 - While in the main tray down drive, the lock signal of M7 is (PS19) FS control board
detected. (FSCB)
- While in the M7 ON, the main tray upper limit switch (SW2)
or the main tray lower limit switch (SW3) turns ON.
FS-511: Alignment motor (M5) drive abnormality.
- While in the alignment home position search, the alignment Alignment motor (M5)
C- home sensor (PS9) does not turn ON within a specified Alignment home sensor
1103 period of time after M5 turns ON. (PS9) FS control board
- While in the alignment operation, PS9 does not turn OFF (FSCB)
within a specified period of time after M5 turns ON.
FS-511: Paper exit roller release motor (M13) drive
abnormality.
Paper exit roller release
- When starting the pressure position drive, the exit roller
C- motor (M13) Exit roller
home sensor (PS13) does not turn ON within a specified
1104 home sensor (PS13) FS
period of time after M13 turns ON.
control board (FSCB)
- When starting the separation position drive, PS13 does not
turn OFF within a specified period of time after M13 turns ON.

Code Description Causes


C- FS-511: Intermediate conveyance roller release Intermediate conveyance roller
1105 motor (M12) drive abnormality. release motor (M12) Roller release
- When starting the pressure position drive, the home sensor (PS12) FS control board
roller release home sensor (PS12) does not turn (FSCB)
ON within a specified period of time after M12
turns ON.
- When starting the separation position drive,
PS12 does not turn OFF within a specified
period of time after M12 turns ON.
3

FS-511: Stapler movement motor (M6) drive


abnormality.
- While in the home position search, the stapler
Stapler movement motor (M6) Stapler
C- home sensor (PS14) does not turn ON within a
home sensor (PS14) FS control board
1106 specified period of time after M6 turns ON.
(FSCB)
- While in the 1-staple position movement, PS14
does not turn OFF within a specified period of
time after M6 turns ON.
FS-511: Stapler motor /Rr (M16) drive
abnormality
- The stapler home sensor /Rr (PS22) does not
turn OFF within a specified period of time after
M16 turns ON. Stapler motor /Rr (M16) Stapler home
C-
- PS22 does not turn ON within a specified sensor /Rr (PS22) FS control board
1107
period of time after the OFF of PS22 is (FSCB)
detected.
- PS22 does not turn ON within a specified
period of time after M16 turns ON for reverse
rotation.
FS-511: Stapler motor /Fr (M17) drive
abnormality
- The stapler home sensor /Fr (PS25) does not
turn OFF within a specified period of time after
M17 turns ON. Stapler motor /Fr (M17) Stapler home
C-
- PS25 does not turn ON within a specified sensor /Fr (PS25) FS control board
1108
period of time after the OFF of PS25 is (FSCB)
detected.
- PS25 does not turn ON within a specified
period of time after M17 turns ON for reverse
rotation.
C- SD: Saddle stapler motor /Fr drive abnormality. Saddle stapler motor /Fr SD control
1109 - When the saddle stapler motor /Fr is ON, it board (SDCB)
does not get off from the home position within a
specified period of time.
- After its getting off from the home position is
detected, it does not get to the home position
within a specified period of time.
- After the saddle stapler motor /Fr turns ON for
reverse rotation, it does not get to the home
position within a specified period of time.
4

C-
1110 SD: Saddle stapler motor /Rr drive abnormality
- When the saddle stapler motor /Rr turns ON, it
does not get off from the home position within a
specified period of time.
- After its getting off from the home position is
Saddle stapler motor /Rr SD control
detected, it does not get to the home position
board (SDCB)
within a specified
period of time.
- After the saddle stapler motor /Rr turns ON for
reverse rotation, it does not get to the home
position within a pecified period of time.

SD: Paper guide motor (M13) drive abnormality


- When M13 turns ON for protrusion, the paper
guide home sensor (PS23) does not turn OFF Paper guide motor (M13) Paper guide
C-
within a specified period of time. home sensor (PS23) SD control
1111
- When M13 turns ON for evacuation, PS23 board (SDCB)
does not turn ON within a specified period of
time.
SD: Staple guide motor (M14) drive abnormality.
- While in the home position return operation,
the staple guide home sensor (PS26) does not
Staple guide motor (M14) Staple
C- turn ON within a specified period of time after
guide home sensor (PS26) SD control
1112 M14 turns ON.
board (SDCB)
- When starting a retraction operation, PS26
does not turn OFF within a specified period of
time after M14 turns ON.
SD: Exit open/close motor (M9) drive
abnormality.
- When starting a pressure contact operation,
the saddle exit home sensor (PS18) does not Exit open/close motor (M9) Saddle
C-
turn ON within a specified period of time after exit home sensor (PS18) SD control
1113
M9 turns ON. board (SDCB)
- When starting a separation operation, PS18
does not turn OFF within a specified period of
time after M9 turns ON.
SD: Folding motor (M10) drive abnormality.
Folding motor (M10) Folding roller
C- - The folding roller home sensor (PS22) does
home sensor (PS22) SD control
1114 not turn ON within a specified period of time
board (SDCB)
after M10 turns ON.
C- SD: Conveyance motor (M8) drive abnormality. Conveyance motor (M8) SD control
1115 - Within a specified period of time after M8 turns board (SDCB)
ON, the ON of a motor lock signal is detected
for a prescribed period of time in succession.
- A specified period of time after M8 turns OFF,
the OFF of a motor lock signal is detected for a
5

prescribed period of time in succession.


FS-510: Exit roller release motor (M6) drive
abnormality.
- When the shutter is closed, the shutter home
Exit roller release motor (M6) Shutter
C- sensor (PS16) does not turn ON within a
home sensor (PS16) FS control board
1116 specified period of time after M6 turns ON.
(FSCB)
- When the shutter is open, PS16 does not turn
OFF within a specified period of time after M6
turns ON.
FS-510: Alignment motor /Fr (M5) drive
abnormality.
- While in the home position search, the
alignment home sensor /Fr (PS7) does not turn Alignment motor /Fr (M5) Alignment
C-
ON within a specified period of time after M5 home sensor /Fr (PS7) FS control
1117
turns ON. board (FSCB)
- While in the home position search, PS7 does
not turn OFF within a specified period of time
after M5 turns ON.
C- FS-510: Exit paddle solenoid (SD2) drive
1118 abnormality.
- While in the paddle evacuation, the exit paddle
Exit paddle solenoid (SD2) Exit
home sensor (PS11) does not turn ON within a
paddle home sensor (PS11) FS
specified period of time after SD2 turns ON.
control board (FSCB)
- While in the paper hold-down operation, PS11
does not turn OFF within a specified period of
time after SD turns ON.
FS-511: Punch motor (M11) drive abnormality.
C- - The punch encoder sensor (PS15) does not Punch motor (M11) FS control board
1119 turn OFF within a specified period of time after (FSCB)
M11 turns ON.
Causes
Code Description

FS-511: Hole punch selector motor (M14)6drive


abnormality (inch system only)
- When starting the punch 2- hole position switch
drive, the hole punch position switch (SW4) is not
C- FS control board (FSCB) Hole
turned ON in the specified period of time after the
1120 punch selector motor (M14)
M14 is turned ON.
- When starting the punch 3- hole position switch
drive, the SW4 is not turned OFF in the specified
period of time after the M14 is turned ON.
PU: Punch motor (M1) drive abnormality. Punch motor (M1) Punch position
C- - The punch position sensors /1 (PS2) and /2 (PS3) sensor /1 (PS2) Punch position
1121 do not turn OFF within a specified period of time sensor /2 (PS3) FS control board
after M1 turns ON. (FSCB)
Image process communication abnormality
- Communication abnormality between the engine
C- control of the overall control board (OACB) and that Overall control board (OACB)
2001 of the printer control board (PRCB) While in the Printer control board (PRCB)
stand-by, a process Ready signal cannot be
detected for a specified period of time.
Developing motor (M3) speed abnormality.
C- - While M3 is ON, an EM error signal has been Developing motor (M3) Printer
2201 detected 5 times in succession within a specified control board (PRCB)
period of time.
Drum motor (M1) speed abnormality.
C- - While M1 is ON, an EM error signal has been Drum motor (M1) Printer control
2202 detected 5 times in succession within a specified board (PRCB)
period of time.
Drum cooling fan (FM4) abnormality.
C- - While FM4 is ON, an EM error signal has been Drum cooling fan (FM4) Printer
2301 detected 5 times in succession within a specified control board (PRCB)
period of time.
Developing suction fan motor (FM6) abnormality.
Developing suction fan motor
C- - While FM6 is ON, an EM error signal has been
(FM6) Printer control board
2302 detected 5 times in succession within a specified
(PRCB)
period of time.
Developing cooling fan (FM7) abnormality.
C- - While FM7 is ON, an EM error signal has been Developing cooling fan (FM7)
2303 detected 5 times in succession within a specified Printer control board (PRCB)
period of time.
C-
High machine inside temperature abnormality.
2401 TCR sensor (TCRS) Printer
- When the temperature around the drum is above
control board (PRCB)
58 °C

Erase lamp (EL) connector slip-off abnormality.


- When EL turns ON before starting an initial
C- Erase lamp (EL) Printer control
charging, EL abnormality has been detected 15
2402 board (PRCB)
times in succession at prescribed intervals after a
specified period of time.
Toner bottle phase detection abnormality.
- While in the power switch (SW2) ON, the toner Toner bottle motor (M10) Toner
C-
bottle position sensor (PS28) does not turn ON bottle position sensor (PS28)
2403
within a specified period of time after the toner Printer control board (PRCB)
bottle motor (M10) turns ON.
Charging abnormality. Charging corona High voltage unit
C-
- An error signal is detected 5 times in succession (HV) Printer control board (PRCB)
7

Code Description Causes


OS error
C-
- There occurs an OS error with the engine control Printer control board (PRCB)
5401
section in the printer control board (PRCB).
C- System control communication abnormality Overall control board (OACB)
5402 - Time out for tuning off the power switch (SW2) Printer control board (PRCB)
C- Image process communication abnormality CCD board (CCDB) Overall
6001 - CCD board (CCDB) connection abnormality. control board (OACB)
Communication abnormality between the engine control
of the overall control board (OACB) and that of the
C- Overall control board (OACB)
printer control board (PRCB). While in the stand-by, a
6002 Printer control board (PRCB)
scanner Ready signal cannot be detected for a specified
period of time.
Communication abnormality between the engine control
C- of the overall control board (OACB) and that of the Overall control board (OACB)
6003 printer control board (PRCB). Time out for the notice Printer control board (PRCB)
time of the platen original size.
While in the exposure unit initial search, the scanner
Scanner motor (M2) Scanner
C- home sensor (PS30) does not turn on within a specified
home sensor (PS30) Printer
6101 period of time. And also, while in the return scan, PS30
control board (PRCB)
does not turn on within a specified period of time.
Exposure lamp (L1) abnormality.
Exposure lamp (L1) L1
C- - A specified period of time after L1 turns on, an L1
inverter (L1 INVVB) Printer
6201 abnormality signal is detected in succession for a
control board (PRCB)
specified period of time.
CCD board (CCDB)
Exposure lamp (L1) L1
C- AOC abnormality.
inverter (L1 INVVB) Scanner
6701 - AOC counter overflow
motor (M2) Overall control
board (OACB)
CCD board (CCDB)
Exposure lamp (L1) L1
C- AGC abnormality.
inverter (L1 INVVB) Scanner
6702 - AGC counter overflow
motor (M2) Overall control
board (OACB)
DF control board (DFCB) communication abnormality.
C- DF control board (DFCB)
- Communication abnormality between the printer control
8001 Printer control board (PRCB)
board (PRCB) and DFCB.
C- Cooling fan (FM3) DF control
Cooling fan (FM3) abnormality.
8301 board (DFCB)

Das könnte Ihnen auch gefallen